Loading...
HomeMy WebLinkAboutPC Reso 23-11 PLPA-2022-00038 Hexcel RedevelopmentReso. No. 23-11, Item 6.1, Adopted 12/12/2023 Page 1 of 3 RESOLUTION NO. 23 11 A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF DUBLIN RECOMMENDING THAT THE CITY COUNCIL CERTIFY THE FINAL ENVIRONMENTAL IMPACT REPORT AND APPROVE AN AMENDMENT TO THE ZONING MAP, A PLANNED DEVELOPMENT ZONING DISTRICT WITH A STAGE 1 AND 2 DEVELOPMENT PLAN, SITE DEVELOPMENT REVIEW PERMIT AND HERITAGE TREE REMOVAL PERMIT FOR THE HEXCEL REDEVELOPMENT PROJECT PLPA 2022-00038 (APNS 941-1560-009-01 AND 941-1560-003-04) WHEREAS, the property owner, Overton Moore Properties, proposes to redevelop an 8.81-acre site located at 11711 Dublin Boulevard. The project would demolish the existing 62,175-square-foot Hexcel research and development building and construct a new 125,304-square-foot light industrial building to appeal to advanced manufacturing and life science uses with 217 parking stalls and related site improvements. Requested approvals include a Planned Development Rezone Stage 1 and Stage 2 Development Plan, Site Development Review Permit and Heritage Tree Removal Permit. These Hexcel Redevelopment ; and WHEREAS, the Project site includes two parcels totaling approximately 8.81 acres located north of the I-580, south of Dublin Boulevard and residential and commercial uses, east of existing office buildings, and west of the U.S. Bank Branch, Dublin Heritage Park and Museums and Dublin Pioneer Cemetery; and WHEREAS, the Project site has a General Plan and Dublin Village Historic Area Specific Plan land use designation of Business Park/Industrial; and WHEREAS, one half of the Project site is subject Planned Development (Alameda County Ordinance No. 80-60) and the other half is zoned M-1 (Light Industrial); and WHEREAS, the proposed Project is consistent with the Business Park/Industrial land use designation but requires a Planned Development Rezone to accommodate the Project; and WHEREAS, the California Environmental Quality Act (CEQA), together with the CEQA Guidelines and City of Dublin CEQA Guidelines and Procedures require that certain projects be reviewed for environmental impacts and that environmental documents be prepared; and Reso. No. 23-11, Item 6.1, Adopted 12/12/2023 Page 2 of 3 WHEREAS, pursuant to the requirements of CEQA, the CEQA Guidelines and City of Dublin CEQA Guidelines and Procedures, the City prepared a Draft Environmental Impact Report (EIR) dated August 2023, and a Final EIR dated November 2023, for the proposed Project, which reflects potential environmental impacts of the Project; and WHEREAS, the Draft EIR identified potentially significant impacts to air quality, biological resources, cultural and tribal resources, energy, geology and soils, and hazards and hazardous materials, most of which can be substantially reduced through mitigation measures; and WHEREAS, the Draft EIR was circulated for 45 days for public comment from August 21, 2023, to October 5, 2023. Comments received on the Draft EIR were responded to in the Final EIR dated November 2023. The Draft EIR, comments and associated responses, and changes and clarifications to the Draft EIR constitute the Final EIR; and WHEREAS, a Staff Report, dated December 12, 2023, and incorporated herein by reference, described and analyzed the Project, including the Planned Development Rezone Stage 1 and Stage 2 Development Plan, Site Development Review Permit, Heritage Tree Removal Permit and Final EIR; and WHEREAS, the Planning Commission held a properly noticed public hearing on the Project, on December 12, 2023, at which time all interested parties had the opportunity to be heard. NOW, THEREFORE, BE IT RESOLVED that the foregoing recitals are true and correct and made a part of this Resolution. BE IT FURTHER RESOLVED that the City of Dublin Planning Commission recommends that the City Council certify the Final EIR and adopt required CEQA Findings for the Hexcel Redevelopment Project. BE IT FURTHER RESOLVED that the Planning Commission recommends that the City Council adopt an Ordinance attached as Exhibit A approving a Planned Development Zoning District with a Stage 1 and Stage 2 Development Plan based on findings, as set forth in Exhibit A. BE IT FURTHER RESOLVED that the Planning Commission recommends that the City Council approve a Resolution attached as Exhibit B approving the Site Development Review Permit and Heritage Tree Removal Permit, based on findings and conditions of approval, as set forth in Exhibit B. PASSED, APPROVED, AND ADOPTED this 12 th day of December 2023 by the following vote: Reso. No. 23-11, Item 6.1, Adopted 12/12/2023 Page 3 of 3 AYES: NOES: ABSENT: ABSTAIN: ATTEST: ______________________________ Planning Commission Chair ____________________________ Assistant Community Development Director Aini,Thalblum,Tyler Grier, Wright Ord. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 1 of 8 ORDINANCE NO. XX – 24 AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF DUBLIN AMENDING THE ZONING MAP AND APPROVING A PLANNED DEVELOPMENT ZONING DISTRICT WITH A STAGE 1 AND STAGE 2 DEVELOPMENT PLAN FOR THE HEXCEL REDEVELOPMENT PROJECT PLPA 2022-00038 (APNS 941-1560-009-01 AND 941-1560-003-04) The Dublin City Council does ordain as follows: SECTION 1. RECITALS A. The property owner, Overton Moore Properties, proposes to redevelop an 8.81-acre site located at 11711 Dublin Boulevard. The project would demolish the existing 62,175-square- foot Hexcel research and development building and construct a new 125,304-square-foot light industrial building to appeal to advanced manufacturing and life science uses with 217 parking stalls and related site improvements. Requested approvals include a Planned Development Rezone Stage 1 and Stage 2 Development Plan, Site Development Review Permit and Heritage Tree Removal Permit. These planning and implementing actions are collectively known as the “Hexcel Redevelopment Project” or the “Project.” B. The Project site includes two parcels totaling approximately 8.81 acres located north of the I- 580, south of Dublin Boulevard and residential and commercial uses, east of existing office buildings, and west of the U.S. Bank Branch, Dublin Heritage Park and Museums and Dublin Pioneer Cemetery. C. The Project site has a General Plan and Dublin Village Historic Area Specific Plan land use designation of Business Park/Industrial. D. The Project site is subject to zoning, where one half of the site is zoned Planned Development (Alameda County Ordinance No. 80-60) and the other half is zoned M-1 (Light Industrial). E. The proposed Project is consistent with the Business Park/Industrial land use designation but requires a Planned Development Rezone to accommodate the Project. F. The California Environmental Quality Act (CEQA), together with the CEQA Guidelines and City of Dublin CEQA Guidelines and Procedures require that certain projects be reviewed for environmental impacts and that environmental documents be prepared. G. Pursuant to the requirements of CEQA, the CEQA Guidelines and City of Dublin CEQA Guidelines and Procedures, the City prepared a Draft Environmental Impact Report (EIR) dated August 2023, and a Final EIR dated November 2023, for the proposed Project, which reflects the City’s independent judgment and analysis of the potential environmental impacts of the Project. Ord. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 2 of 8 H. The Draft EIR identified potentially significant impacts to air quality, biological resources, cultural and tribal resources, energy, geology and soils, and hazards and hazardous materials, most of which can be substantially reduced through mitigation measures. I. The Draft EIR was circulated for 45 days for public comment from August 21, 2023, to October 5, 2023. Comments received on the Draft EIR were responded to in the Final EIR dated November 2023. The Draft EIR, comments and associated responses, and changes and clarifications to the Draft EIR constitute the Final EIR. J. Following a properly noticed public hearing on December 12, 2023, the Planning Commission adopted Resolution No. 22-xx, recommending that the City Council certify the Final EIR and adopt required CEQA Findings, and approve a Planned Development Zoning District with a Stage 1 and Stage 2 Development Plan, Site Development Review Permit and Heritage Tree Removal Permit, which Resolution is incorporated herein by reference and available for review at City Hall during normal business hours. K. A Staff Report dated _______, and incorporated herein by reference, described and analyzed the proposed Project, including the Planned Development Rezone Stage 1 and Stage 2 Development Plan, Site Development Review Permit, Heritage Tree Removal Permit and Final EIR, for the City Council. L. On ______, the City Council held a properly noticed public hearing on the Project, including the Planned Development Rezone Stage 1 and Stage 2 Development Plan, Site Development Review Permit and Heritage Tree Removal Permit at which time all interested parties had the opportunity to be heard. M. The City Council considered the Final EIR prepared for the Project, and all above referenced reports, recommendations, and testimony prior to taking action on the Project. N. On __________, the City Council adopted Resolution xx-22 certifying the Final EIR and adopting CEQA Findings, a Statement of Overriding Considerations and a Mitigation Monitoring and Reporting Program for the Project. O. The City Council did hear and use independent judgment and considered all said reports, recommendations, and testimony herein above set forth. SECTION 2: FINDINGS A. Pursuant to Section 8.32.070 of the Dublin Municipal Code (DMC), the City Council finds as follows. 1. The Hexcel Redevelopment Project (“the Project”) PD-Planned Development Zoning meets the purpose and intent of DMC Chapter 8.32, in that it provides a comprehensive development plan that will be consistent with the General Plan and Dublin Village Historic Area Specific Plan, and protects the integrity and character of the area by creating a desirable use of land that is sensitive to surrounding land uses by virtue of the layout and design of the site plan. The Project is planned comprehensively and will follow development standards tailored to the specific needs of the site. These standards will address issues such as building setbacks, architecture, landscaping and grading. The proposed building will blend with the natural features unique to the site through design and planning. The Ord. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 3 of 8 Applicant proposes an outdoor seating area and sufficient landscaping within new bi- retention areas and the new parking lot, along the site perimeter and the frontage of the building façade, which are consistent with the provisions and regulations for development set forth therein. 2. Development of the Project under the PD-Planned Development Zoning will be harmonious and compatible with existing and future development in the surrounding area, in that the proposed Project would redevelop an existing developed site with a light industrial building catering to advanced manufacturing and life science uses, which is consistent with the General Plan and Dublin Village Historic Area Specific Plan. B. Pursuant to DMC Sections 8.120.050 A and B, the City Council finds as follows. 1. The PD-Planned Development Zoning for the Project will be harmonious and compatible with existing and potential development in the surrounding area, in that the proposed Project would redevelop an existing developed site with a light industrial building catering to advanced manufacturing and life science uses and has taken into account adjacent land uses. 2. The Project site is physically suitable for the type and intensity of the zoning district being proposed, in that the site is flat with existing access provided from Dublin Boulevard and is served by existing public utilities. The Project site conditions were documented in the EIR prepared for the Project, and the environmental impacts that have been identified will be mitigated to the greatest degree possible. There are no major physical or topographic constraints and, thus, the site is physically suitable for the type and intensity of uses proposed through the PD-Planned Development Zoning. 3. The PD-Planned Development Zoning will not adversely affect the health or safety of persons residing or working in the vicinity, or be detrimental to the public health, safety and welfare, in that the Project will comply with all applicable development regulations and standards and will implement all adopted mitigation measures. In order to ensure adequate emergency vehicle access to all portions of the site, access is provided to the site from Dublin Boulevard. 4. The PD-Planned Development Zoning is consistent with and in conformance with the Dublin General Plan and the Dublin Village Historic Area Specific Plan, in that the proposed light industrial building is consistent with the existing Business Park/Industrial land use designation for the site, which allows non-retail businesses such as research, limited manufacturing and distribution activities, and administrative offices. The Project complies with this designation as it will provide for an attractive facility that appeals to advanced manufacturing and life science uses that will not generate nuisances related to emissions, noise, odors, or glare. C. Pursuant to CEQA, the City Council certified a Final EIR via Resolution No. xx-22 on __________, prior to approving the Project. SECTION 3: ZONING MAP AMENDMENT Pursuant to Chapter 8.32, Title 8 of the City of Dublin Municipal Code, the City of Dublin Zoning Map is amended to rezone the property described below to a Planned Development Zoning Ord. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 4 of 8 District and supersedes the previously adopted Planned Development Zoning (Alameda County Ordinance No. 80-60) and M-1 Zoning (Light Industrial): 8.81 acres located north of the I-580, south of Dublin Boulevard, east of existing office buildings, and west of the U.S. Bank Branch, Dublin Heritage Park and Museums and Dublin Pioneer Cemetery, which includes the following Assessor’s Parcel Numbers: 941- 1560-009-01 AND 941-1560-003-04 (“the Property”). A map of the rezoning area is shown below: Section 4. APPROVAL OF STAGE 1 AND 2 DEVELOPMENT PLAN The regulations for the use, development, improvement, and maintenance of the Property are set forth in the following Stage 1 and Stage 2 Development Plan for the entire 8.81-acre Project area, which is hereby approved. Any amendments to the Stage 1/Stage 2 Development Plan shall be in accordance with Section 8.32.080 of the Dublin Municipal Code or its successors. Stage 1 and Stage 2 Development Plan This is a Stage 1 and Stage 2 Development Plan pursuant to Chapter 8.32 of the Dublin Municipal Code. This Development Plan meets all the requirements for both a Stage 1 and Stage 2 Development Plan and is adopted as part of the PD-Planned Development rezoning for the Hexcel Redevelopment Project (PLPA-2022-00005). The Planned Development zoning district and this Stage 1 and Stage 2 Development Plan provides flexibility to encourage innovative development while ensuring that the goals, policies, and action programs of the General Plan and provisions of DMC Chapter 8.32 are satisfied. 1. Statement of Uses Parcel 1 Permitted Uses (as defined by the Zoning Ordinance): Industrial – Light (Warehouse and Distribution uses involving heavy truck traffic are not permitted) Office – Professional/Administrative Similar and related uses as determined by the Director of Community Development Ord. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 5 of 8 Conditional Uses: None Accessory Uses: Uses which are necessarily and customarily associated with, and are appropriate, incidental, and subordinate to the principal uses as determined by the Director of Community Development Parcel 2 No development or uses are permitted on Parcel 2. 2. Stage 1 and Stage 2 Site Plan The Stage 1 and Stage 2 Site Plan is shown below. Ord. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 6 of 8 3. Development Regulations The following Development Standards apply to Parcel 1 only. No development is permitted on Parcel 2. Floor Area Ratio 0.33 Maximum Building Height: 40 feet Maximum lot coverage 31% Parking Spaces Office: Up to 7,500 square feet - 1 per 250 square feet 7,501 to 40,000 square feet - 1 per 300 square feet 40,001+ square feet - 1 per 350 square feet Industrial – Light: 1 per 400 square feet of general purpose area, plus 1 per 1,000 square feet of warehouse or distribution area Parking Stall Dimensions Standards Per Dublin Municipal Code Chapter 8.76 (Off- Street Parking and Loading Regulations) Minimum Setbacks 10’ front (along Dublin Boulevard) 10’ side (along west and east property lines) 20’ rear (along south property line) Signage Per Dublin Municipal Code Chapter 8.84 (Sign Regulations) 4. Phasing Plan. The Project will be built in one phase, first beginning with demolition, and followed by site preparation/grading, trench and foundation, exterior building construction, interior building construction and paving/landscaping. 5. General Plan and Specific Plan Consistency. The Project is consistent with the General Plan and Dublin Village Historic Area Specific Plan land use designation of Business Park/Industrial, which allows non-retail businesses such as research, limited manufacturing and distribution activities, and administrative offices. In addition, the proposed Project design will provide for an attractive building that appeals to advanced manufacturing and life science uses that will not generate heavy truck traffic and nuisances related to emissions, noise, odors, or glare and is consistent with the floor area ratio of 0.30 to 0.40 allowed in the Business Park/Industrial land use designation. 6. Inclusionary Zoning Regulations. The proposed Project is an industrial use type and is not subject to the Inclusionary Zoning Regulations (DMC Chapter 8.68) for the provision of affordable housing because the regulations apply only to residential development projects of 20 units or more. 7. Architectural Standards. The Project’s architectural style utilizes a contemporary design approach that is industrial in nature and is unique to light industrial, advanced manufacturing and life science uses. Ord. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 7 of 8 The architectural design of the Project shall reflect the following standards: • Incorporate features such as different wall planes, and horizontal and vertical reveals to break down the building form into more human scale volumes. • Use varying colors, panel reliefs to mimic wood siding, heights, low slope/flat roof construction, light fixtures, and landscaping to enhance the building detail at the pedestrian level. • Colors shall be neutral in nature, while bright/harsh primary colors shall be avoided. • Lighter building color applications including off-white for portions of the façade and window trim shall be used to provide interest. • Provide outdoor space for tenants, which allows for gathering and socializing, with landscaping, outdoor seating, enhanced paving treatment, and other features to provide an appropriate urban scale for the development. 8. Preliminary Landscaping Plan. The conceptual landscape design of the Project shall reflect the following standards: • Provide plentiful green space and natural habitat that utilizes a native and climate- adaptive planting palette to Dublin and is considered moderate or low water use. • Provide a generous landscape buffer along the perimeter of the project site to soften the main street frontage, rear and sides of the building, and reduce the mass of the building onto adjacent properties. • As shown on the Preliminary Landscape Plan, preserve existing trees where possible along the site perimeter to further enhance the landscape buffer and better integrate the new development into the surrounding community. • Utilize plants that provide a year-round vegetated landscape with seasonality, color, and interest for an attractive visual environment. 9. Aerial Photo. 10. Applicable Requirements of Dublin Zoning Ordinance. Except as specifically provided in this Stage 1 and Stage 2 Development Plan, the use, development, improvement, and maintenance of the property shall be subject to the regulations of the closest comparable Ord. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 8 of 8 zoning district as determined by the Community Development Director and the Dublin Zoning Ordinance. No development shall occur on this property until a Site Development Review Permit has been approved. SECTION 5. SEVERABILITY The provisions of this Ordinance are severable and if any provision, clause, sentence, word or part thereof is held illegal, invalid, unconstitutional, or inapplicable to any person or circumstances, such illegality, invalidity, unconstitutionality, or inapplicability shall not affect or impair any of the remaining provisions, clauses, sentences, sections, words or parts thereof of the ordinance or their applicability to other persons or circumstances. SECTION 6. EFFECTIVE DATE This Ordinance shall take effect thirty (30) days following its adoption. SECTION 7. POSTING OF ORDINANCE The City Clerk of the City of Dublin shall cause this Ordinance to be posted in at least three (3) public spaces in the City of Dublin in accordance with Section 36933 of the Government Code of the State of California. PASSED, APPROVED AND ADOPTED this __th day of _______ 2024, by the following vote: AYES: NOES: ABSENT: ABSTAIN: ______________________________ Mayor ATTEST: _________________________________ City Clerk 5555124.2 Reso. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 1 of 34 RESOLUTION NO. XX – 24 A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF DUBLIN APPROVING A SITE DEVELOPMENT REVIEW PERMIT AND HERITAGE TREE REMOVAL PERMIT FOR THE HEXCEL REDEVELOPMENT PROJECT PLPA 2022-00038 (APNS 941-1560-009-01 AND 941-1560-003-04) WHEREAS, the property owner, Overton Moore Properties, proposes to redevelop an 8.81-acre site located at 11711 Dublin Boulevard. The project would demolish the existing 62,175- square-foot Hexcel research and development building and construct a new 125,304-square-foot light industrial building to appeal to advanced manufacturing and life science uses with 217 parking stalls and related site improvements. Requested approvals include a Planned Development Rezone Stage 1 and Stage 2 Development Plan, Site Development Review Permit and Heritage Tree Removal Permit. These planning and implementing actions are collectively known as the “Hexcel Redevelopment Project” or the “Project” and WHEREAS, the Project site includes two parcels totaling approximately 8.81 acres located north of the I-580, south of Dublin Boulevard and residential and commercial uses, east of existing office buildings, and west of the U.S. Bank Branch, Dublin Heritage Park and Museums and Dublin Pioneer Cemetery; and WHEREAS, the Project site has a General Plan and Dublin Village Historic Area Specific Plan land use designation of Business Park/Industrial; and WHEREAS, the Project site is subject to zoning, where one half of the site is zoned Planned Development (Alameda County Ordinance No. 80-60) and the other half is zoned M-1 (Light Industrial); and WHEREAS, the proposed Project is consistent with the Business Park/Industrial land use designation but requires a Planned Development Rezone to accommodate the Project; and WHEREAS, the California Environmental Quality Act (CEQA), together with the CEQA Guidelines and City of Dublin CEQA Guidelines and Procedures require that certain projects be reviewed for environmental impacts and that environmental documents be prepared; and WHEREAS, pursuant to the requirements of CEQA, the CEQA Guidelines and City of Dublin CEQA Guidelines and Procedures, the City prepared a Draft Environmental Impact Report (EIR) dated August 2023, and a Final EIR dated November 2023, for the proposed Project, which reflects the City’s independent judgment and analysis of the potential environmental impacts of the Project; and WHEREAS, the Draft EIR identified potentially significant impacts to air quality, biological resources, cultural and tribal resources, energy, geology and soils, and hazards and hazardous materials, most of which can be substantially reduced through mitigation measures; and WHEREAS, the Draft EIR was circulated for 45 days for public comment from August 21, 2023, to October 5, 2023. Comments received on the Draft EIR were responded to in the Final Reso. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 2 of 34 EIR dated November 2023. The Draft EIR, comments and associated responses, and changes and clarifications to the Draft EIR constitute the Final EIR; and WHEREAS, following a properly noticed public hearing on December 12, 2023, the Planning Commission adopted Resolution No. 22-xx, recommending that the City Council certify the Final EIR and adopt required CEQA Findings, and approve a Planned Development Zoning District with a Stage 1 and Stage 2 Development Plan, Site Development Review Permit and Heritage Tree Removal Permit, which Resolution is incorporated herein by reference and available for review at City Hall during normal business hours; and WHEREAS, a Staff Report dated _______, and incorporated herein by reference, described and analyzed the proposed Project, including the Planned Development Rezone Stage 1 and Stage 2 Development Plan, Site Development Review Permit, Heritage Tree Removal Permit and Final EIR, for the City Council; and WHEREAS, on ______, the City Council held a properly noticed public hearing on the Project, including the Planned Development Rezone Stage 1 and Stage 2 Development Plan, Site Development Review Permit and Heritage Tree Removal Permit at which time all interested parties had the opportunity to be heard; and WHEREAS, the City Council considered the Final EIR prepared for the Project, and all above referenced reports, recommendations, and testimony prior to taking action on the Project; and WHEREAS, on __________, the City Council adopted Resolution xx-22 certifying the Final EIR and adopting CEQA Findings, a Statement of Overriding Considerations and a Mitigation Monitoring and Reporting Program for the Project; and WHEREAS, the City Council did hear and use independent judgment and considered all said reports, recommendations, and testimony herein above set forth. NOW, THEREFORE, BE IT RESOLVED that the City Council of the City of Dublin does hereby make the following findings and determinations regarding the Site Development Review Permit for the Hexcel Redevelopment Project: A. The proposal is consistent with the purposes of this Chapter, with the General Plan and with any applicable Specific Plans and design guidelines because: 1) the proposed project is consistent with the General Plan land use designation of Business Park/Industrial as it will provide space for light industrial uses that would cater to advanced manufacturing and life science tenants that will not generate nuisances related to emissions, noise, odors, or glare; 2) the proposed Project gives thoughtful consideration to the surrounding area through setbacks, height, architectural elements and landscape design; and 3) the proposed Project will conform to the allowable uses and development standards as stated in the Stage 1 and Stage 2 Development Plan. B. The proposal is consistent with the provisions of Title 8, Zoning Ordinance because: 1) the Planned Development Zoning provides a comprehensive development plan that creates a desirable use of land that is sensitive to surrounding land uses by virtue of the layout and design of the site plan; and 2) development of the Project under the Planned Development Zoning will be harmonious and compatible with existing and future development in the surrounding area, in that the site will provide new light industrial facility. Reso. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 3 of 34 C. The design of the Project is appropriate to the City, the vicinity, surrounding properties, and the lot(s) in which the Project is proposed because: 1) the Project site is adjacent to Office uses and is appropriately setback and screened from adjacent properties; 2) the proposed development will consist of a light industrial facility that would appeal to advanced manufacturing and life science uses that would provide for additional employment opportunities and innovation in the Dublin community and surrounding areas; and 3) the design of the Project has taken into account sensitive adjacencies and will provide for a light industrial facility for advanced manufacturing and life science companies. D. The subject site is physically suitable for the type and intensity of the approved development because: 1) the Project site is flat with access provided from Dublin Boulevard and is served by existing public utilities; 2) development intensity is consistent with the floor area ratio and employee density for the Business Park/Industrial land use designation; and 3) the Project site conditions were documented in the EIR that has been prepared, and the environmental impacts that have been identified will be mitigated to the greatest degree possible. E. Impacts to existing slopes and topographic features are addressed because: 1) the Project site is flat; 2) the roadway and utility infrastructure to serve the site already exist; and 3) future approval of grading and improvement plans will enable the site to be modified to suit the Project, which will be developed for the site in accordance with City policies and regulations. F. Architectural considerations including the character, scale and quality of the design, site layout, the architectural relationship with the site and other buildings, screening of unsightly uses, lighting, building materials and colors and similar elements result in a project that is harmonious with its surroundings and compatible with other development in the vicinity because: 1) use of varying building planes and colors and the contrast between horizontal and vertical reveals would break up the scale of the concrete tilt-up panels and overall building mass; 2) the panel reliefs mimic the wood siding used on historic buildings in the specific plan area; 3) lighter building color applications including off-white for portions of the façade and window trim are used to provide interest; 4) articulation in plan and elevation and projecting window trim further break up the scale of the building and distinguish each office entrance; 5) the loading docks will be screened from public view on Dublin Boulevard by the building and from the I-580 by new and existing landscaping treatment on the south side of the project site; and 6) the existing sidewalk that runs along the site frontage leading into the property will be further extended into the project site with direct access to the outdoor seating area at the main building entrance, thereby providing a strong relationship between the street and building and enhance the project’s connectivity to the surrounding area. G. Landscape considerations, including the location, type, size, color, texture and coverage of plant materials, and similar elements have been incorporated into the project to ensure visual relief, adequate screening and an attractive environment for the public because: 1) landscape plan features a low water usage plant palette, including a variety of drought tolerant trees, shrubs and ground cover to provide visual interest in texture and color while conserving natural resources. Native plants are utilized to encourage biodiversity in Reso. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 4 of 34 conjunction with the existing riparian vegetation and Dublin Creek on Parcel 2; 2) sufficient plant screening is provided in the setback between the site and adjacent community area north of Dublin Boulevard to minimize any undesirable visual impacts; 3) the loading docks will be screened by new and existing landscaping treatment on the south side of the project site; 4) large shade trees are provided within the parking lot to minimize radiation, provide a cooler environment, and reduce urban heat island effect; 5) a variety of drought tolerant trees, plants, and shrubs are included to provide visual interest in texture and color palette; and 6) the landscape design was conducted in a manner that preserves the existing heritage trees on-site by incorporating them into the site design. H. The site has been adequately designed to ensure proper circulation for bicyclists, pedestrians and automobiles because: 1) the project site is accessed from two existing driveways on Dublin Boulevard with the main driveway located at the intersection of Dublin Boulevard and Hansen Drive and the secondary driveway located at the northeastern corner of the project site (east of Hansen Drive adjacent to the U.S. Bank Branch entrance); 2) the existing sidewalk that runs along the site frontage leading into the property will be further extended into the project site and provide direct access to the main building entrance and outdoor seating area; 3) safe and convenient pedestrian paths are proposed between the building entrances, public sidewalks, and on-site parking lot; 4) all infrastructure including, pathways, sidewalks, and lighting have been reviewed for conformance with City policies, regulations, and best practices and have been designed with multi-modal travel in mind; and 5) the Project has been reviewed by the Public Works Department and Fire Department and adequate access and circulation has been provided on-site. BE IT FURTHER RESOLVED that the City Council of the City of Dublin does hereby approve Heritage Tree Removal Permit for the Hexcel Redevelopment Project. BE IT FURTHER RESOLVED that the Dublin City Council does hereby approve the Site Development Review Permit for the Hexcel Redevelopment Project subject to the conditions included below, and other plans, and text relating to this Site Development Review Permit. CONDITIONS OF APPROVAL: Unless stated otherwise, all Conditions of Approval shall be complied with prior to the issuance of building permits and shall be subject to Planning Division review and approval. The following codes represent those departments/agencies responsible for monitoring compliance of the conditions of approval: [PL] Planning; [B] Building; [PO] Police; [PW] Public Works; [ADM] Administration/City Attorney; [FIN] Finance; [PCS] Parks and Community Services; [F] Dublin Fire Prevention; [DSR] Dublin San Ramon Services District; [LDD] Livermore Dublin Disposal; [CO] Alameda County Department of Environmental Health; [Zone 7] Alameda County Flood Control and Water Conservation District, Zone 7; [LAVTA] Livermore Amador Valley Transit Authority; and [CHS] California Department of Health Services. Reso. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 5 of 34 CONDITION TEXT RESPONA GENCY WHEN REQUIRED Prior to: PLANNING – GENERAL 1. Approval. This approval is for the Hexcel Redevelopment Project generally depicted and indicated on the Project Plans prepared by HPA Architecture, dated October 7, 2022, attached as Exhibit A and other plans, text, and diagrams relating to this project, and as specified as the following Conditions of Approval for this project. PL On-going 2. Effective Date. This Site Development Review Permit approval becomes effective once the Planned Development Rezoning has been approved by City Council and is effective. PL On-going 3. Permit Expiration. Construction or use shall commence within one (1) year of Permit approval or the Site Development Review Permit shall lapse and become null and void. If there is a dispute as to whether the Site Development Review Permit has expired, the City may hold a noticed public hearing to determine the matter. Such a determination may be processed concurrently with revocation proceedings in appropriate circumstances. If the Site Development Review Permit expires, a new application must be made and processed according to the requirements of the Zoning Ordinance. PL One Year After Effective Date 4. Time Extension. The Director of Community Development may, upon the Applicant’s written request for an extension of approval prior to expiration, and upon the determination that any Conditions of Approval remain adequate to assure that applicable findings of approval will continue to be met, grant a time extension of approval for a period not to exceed twelve (12) months. The Director of Community Development may grant a maximum of two (2) extensions of approval, and additional extensions may be granted by the original decision maker. PL Prior to Expiration Date 5. Compliance. The Applicant/Property Owner shall operate this use in compliance with the Conditions of Approval of this Site Development Review Permit, the approved plans and the regulations established in the Zoning Ordinance. Any violation of the terms or conditions specified may be subject to enforcement action. PL On-going 6. Modifications. Modifications or changes to this Site Development Review Permit approval may be considered by the Community Development Director if the modifications or changes proposed comply with Dublin Municipal Code (DMC) Section 8.104.100. PL On-going Reso. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 6 of 34 7. Revocation of Permit. The Site Development Review Permit approval shall be revocable for cause in accordance with DMC Section 8.96.020.I. Any violation of the terms or conditions of this permit shall be subject to citation. PL On-going 8. Requirements and Standard Conditions. The Applicant/Developer shall comply with applicable City of Dublin Fire Prevention Bureau, Dublin Public Works Department, Dublin Building Department, Dublin Police Services, Alameda County Flood Control District Zone 7, Livermore Amador Valley Transit Authority, Alameda County Public and Environmental Health, Dublin San Ramon Services District and the California Department of Health Services requirements and standard conditions. Prior to issuance of building permits or the installation of any improvements related to this project, the Applicant/Developer shall supply written statements from each such agency or department to the Planning Department, indicating that all applicable conditions required have been or will be met. Various Building Permit Issuance 9. Required Permits. The Applicant/Developer shall obtain all permits required by other agencies including, but not limited to Alameda County Flood Control and Water Conservation District Zone 7, California Department of Fish and Wildlife, Army Corps of Engineers, Regional Water Quality Control Board, Caltrans and provide copies of the permits to the Public Works Department. PW Building Permit Issuance and Grading Permit Issuance 10. Fees. The Applicant/Developer shall pay all applicable fees in effect at the time of building permit issuance, including, but not limited to, Planning fees, Building fees, Traffic Impact Fees, TVTC fees, Dublin San Ramon Services District fees, Public Facilities fees, Dublin Unified School District School Impact fees, Fire Facilities Impact fees, Alameda County Flood and Water Conservation District (Zone 7) Drainage and Water Connection fees; or any other fee that may be adopted and applicable. Various Building Permit Issuance 11. Indemnification. Applicant shall defend, indemnify, and hold harmless the City of Dublin and its agents, officers, and employees from any claim, action, or proceeding against the City of Dublin or its agents, officers, or employees to attack, set aside, void, or annul an approval of the City of Dublin or its advisory agency, appeal board, Planning Commission, City Council, Community Development Director, Zoning Administrator, or any other department, committee, or agency of the City ; provided, however, that the Applicant's duty to so defend, indemnify, and hold harmless shall be subject to the City's promptly notifying ADM On-going Reso. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 7 of 34 the Applicant of any said claim, action, or proceeding and the City's full cooperation in the defense of such actions or proceedings. 12. Clarification of Conditions. In the event that there needs to be clarification to the Conditions of Approval, the Director of Community Development and the City Engineer have the authority to clarify the intent of these Conditions of Approval to the Applicant/Developer without going to a public hearing. The Director of Community Development and the City Engineer also have the authority to make minor modifications to these conditions without going to a public hearing in order for the Applicant/Developer to fulfill needed improvements or mitigations resulting from impacts to this project. PL, PW On-going 13. Clean-up. The Applicant/Developer shall be responsible for clean-up and disposal of project related trash to maintain a safe, clean and litter-free site. PL On-going 14. Construction Trailer. The Applicant/Developer shall obtain a Temporary Use Permit prior to the establishment of any construction trailer, storage shed, or container units on the Project site. PL Establishment of the Temporary Use 15. Equipment Screening. All electrical equipment, fire risers, and/or mechanical equipment shall be screened from public view by landscaping and/or architectural features and that electrical transformers are either underground or architecturally screened. Any roof-mounted equipment shall be completely screened from adjacent street view by materials architecturally compatible with the building and to the satisfaction of the Community Development Director. The Building Permit plans shall show the location of all equipment and screening for review and approval by the Community Development Director. PL Building Permit Issuance PLANNING – PROJECT SPECIFIC CONDITIONS 16. Public Art. The project is required to comply with DMC Sections 8.58.05A and 8.58.05D of Chapter 8.58 (Public Art Program). The project will make a monetary contribution in-lieu of acquiring and installing a public art project on the property, as provided by the DMC Section 8.58.050D. The in-lieu contribution shall be as provided in the DMC Chapter 8.58. PL Building Permit Issuance 17. Mitigation Monitoring Program. The Applicant/Developer shall comply with the applicable mitigation measures of the 2023 Hexcel Redevelopment Environmental Impact Report certified by Resolution No. XX-23, including any applicable action programs and implementation measures contained in Resolution No. XX-23. The EIR is on file with the Community Development Department. PL Ongoing Reso. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 8 of 34 18. Final Landscape and Irrigation Plan. Plans shall comply with DMC Chapter 8.72 and be generally consistent with the project plans attached to this Resolution as Exhibit A prepared and stamped by a State licensed landscape architect or registered engineer shall be submitted for review and approval by the Community Development Director. PL Building Permit Issuance 19. Water Efficient Landscaping Regulations. The Applicant/Developer shall meet all requirements of the City of Dublin's Water-Efficient Landscaping Regulations contained in DMC Chapter 8.88 and submit written documentation to the Public Works Department (in the form of a Landscape Documentation Package and other required documents) that the development conforms to the City’s Water Efficient Landscaping Ordinance. PL Building Permit Issuance 20. Landscape Edges. Concrete curbs or bands shall be used at the edges of all planters and paving surfaces, unless otherwise defined differently. The design width and depth of the concrete edge shall be to the satisfaction of the Community Development Director and City Engineer. PL Building Permit Issuance 21. Backflow Prevention Devices. The Landscape Plan shall show the location of all backflow prevention devises. The location and screening of the backflow prevention devices shall be reviewed and approved by City staff. PL Building Permit Issuance 22. Maintenance of Landscape. All landscape areas on the site shall be enhanced and properly maintained at all times. Any proposed or modified landscaping to the site, including the removal or replacement of trees, shall require prior review and written approval from the Community Development Director. PL On-going 23. Distance Between Light Poles and Tree Trunks. A minimum distance of 15 feet shall be provided between light poles and tree trunks. PL Building Permit Issuance 24. Protection of Existing Landscaping on Adjacent Property. To the maximum extent feasible, existing landscaping on the adjacent property to the east, including but not limited to trees, shrubbery, and vines on the existing fence, shall be protected during grading/construction activities. Protection measures shall include fencing trees at the drip line perimeter and, where construction is proposed within existing driplines, excavating by hand. In addition, roots over one (1) inch in diameter that must be cut shall be observed and approved by the City Arborist. PL On-going 25. Protection of Heritage Trees. Prior to obtaining a demolition permit, a tree protection plan shall be prepared for the heritage trees to remain on Parcel 1. PL Demolition Permit Issuance BUILDING AND SAFETY Reso. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 9 of 34 26. Building Codes and Ordinances. All project construction shall conform to all building codes and ordinances in effect at the time of building permit. B Through Completion 27. Construction Drawings. Construction plans shall be fully dimensioned (including building elevations) accurately drawn (depicting all existing and proposed conditions on site), and prepared and signed by a California licensed Architect or Engineer. All structural calculations shall be prepared and signed by a California licensed Architect or Engineer. The site plan, landscape plan and details shall be consistent with each other. B Issuance of Building Permits 28. Building Permits. To apply for building permits, Applicant/Developer shall submit electronic drawings for plan check. An annotated copy of the Conditions of Approval shall be included with the submittal. The notations shall clearly indicate how all Conditions of Approval will or have been complied with. Construction plans will not be accepted without the annotated resolutions attached to each set of plans. Applicant/Developer will be responsible for obtaining the approvals of all participation non-City agencies prior to the issuance of building permits. B Issuance of Building Permits 29. As-Built Drawings. All revisions made to the building plans during the project shall be incorporated into an “As Built” electronic file and submitted prior to the issuance of the final occupancy. B Occupancy 30. Addressing a) Provide a site plan with the City of Dublin’s address grid overlaid on the plans (1 to 30 scale). Highlight all exterior door openings on plans (front, rear, garage, etc.). The site plan shall include a single large format page showing the entire project and individual sheets for each neighborhood. Application and required plans shall be submitted electronically. b) Address signage shall be provided as per the Dublin Commercial Security Code. c) Address will be required on all doors leading to the exterior of the building. Addresses shall be illuminated and be able to be seen from the street, four (4) inches in height minimum. B a) Prior to Release of Addresses b) Prior to Permitting c) Prior to Occupancy 31. Engineer Observation. The Engineer of record shall be retained to provide observation services for all components of the lateral and vertical design of the building, including nailing, hold-downs, straps, shear, roof diaphragm and structural frame of building. A B Prior to Scheduling the Final Reso. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 10 of 34 written report shall be submitted to the City Inspector prior to scheduling the final frame inspection. Frame Inspection 32. 60-Foot No Build Covenant. Pursuant to Dublin Municipal Code Section 7.32.130, the owner shall file with the Building Official a Covenant and Agreement Regarding Maintenance of Yards for an Oversized Building binding such owner, his heirs, and assignees, to set aside a 60-foot required yard as unobstructed space having no improvements. After execution by the owner and Building Official, such covenant shall be recorded in the Alameda County Recorder’s Office, and shall continue in effect so long as an oversized building remains or unless otherwise released by authority of the Chief Building Official. B Prior to Permitting 33. Foundation. Geotechnical Engineer for the soils report shall review and approve the foundation design. A letter shall be submitted to the Building Division on the approval. B Prior to Permit Issuance 34. Air Conditioning Units. Air conditioning units and ventilation ducts shall be screened from public view with materials compatible to the main building. Units shall be permanently installed on concrete pads or other non- movable materials approved by the Chief Building Official and Director of Community Development. B Occupancy of Building 35. Plumbing Fixture Count. The plumbing fixture count (e.g., water closets, lavatories, urinals, drinking fountains) shall meet the minimum requirements for the use as regulated by the CA Plumbing Code. B Prior to Permitting 36. Solar Zone – CA Energy Code. Show the location of the Solar Zone on the site plan. Detail the orientation of the Solar Zone. This condition of approval will be waived if the project meets the exceptions provided in the CA Energy Code. B Through Completion 37. Accessible Parking. The required number of parking stalls, the design and location of the accessible parking stalls shall be as required by the CA Building Code, Chapter 11-B. B Through Completion 38. Green Parking. The design and number of clean air/ EV ready stalls shall be as required by the CA Green Building Standards Code. B Through Completion 39. Retaining Walls. All retaining walls over 30 inches in height and adjacent to a walkway shall be provided with guardrails. Retaining walls with a surcharge and retaining walls over 36 inches in height shall obtain permits and inspections from the Building & Safety Division. B Through Completion 40. Accessory Structures. Building permits are required for all trash enclosures and associated amenities / structures and are required to meet the accessibility and building codes. B Through Completion Reso. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 11 of 34 41. FEMA – Floodplain. The property is currently shown to be in a floodplain. If the building is located within the floodplain, the applicant shall submit either a letter of map amendment, letter of map change or letter of map revision prior to permitting. If the location of the building has not been removed from the floodplain by a letter, then elevation certificates will be required at the correct stages. B Prior to Permitting 42. Temporary Fencing. Temporary construction fencing shall be installed along perimeter of all work under construction B Through Completion 43. Copies of Approved Plans. Applicant shall provide City with one reduced (1/2 size) copy of the City of Dublin stamped approved plan. B 30 Days After Permit and Each Revision Issuance FIRE PREVENTION 44. Fire Apparatus Access Road Fire department access requirements are to be met. All fire apparatus access road shall be with an approved all-weathered surface and capable of supporting imposed load of 75,000 lbs. F Approval of Improvement Plans 45. Fire Hydrants All existing and proposed fire hydrants shall comply with the requirements in CFC Section 507.5, Appendix B, and Appendix C. F Approval of Improvement Plans 46. No fire service lines shall pass beneath buildings. F Approval of Improvement Plans 47. New Fire Sprinkler System & Monitoring Requirements In accordance with The Dublin Fire Code, fire sprinklers shall be installed in the building. The system shall be in accordance with the NFPA 13, the CA Fire Code and CA Building Code. Plans and specifications showing detailed mechanical design, cut sheets, listing sheets and hydraulic calculations shall be submitted to the Fire Department for approval and permit prior to installation. This may be a deferred submittal. a) Sprinkler Plans. (Deferred Submittal Item). Submit detailed mechanical drawings of all sprinkler modifications, including cut sheets, listing sheets and calculations to the Fire Department for approval and permit prior to installation. b) All sprinkler system components shall remain in compliance with the applicable N.F.P.A. 13 Standard, the CA Fire Code and the CA Building Code. c) Underground Plans. (Deferred Submittal Item). Submit detailed shop drawings for the fire water supply system, including cut sheets, listing sheets F Building Permit Issuance Reso. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 12 of 34 and calculations to the Fire Department for approval and permit prior to installation. All underground and fire water supply system components shall be in compliance with the applicable N.F.P.A. 13, 24, 20, 22 Standards, the CA Fire Code and the CA Building Code. The system shall be hydrostatically tested and inspected prior to being covered. Prior to the system being connected to any fire protection system, a system flush shall be witnessed by the Fire Department. d) Central Station Monitoring. Automatic fire extinguishing systems installed within buildings shall have all control valves and flow devices electrically supervised and maintained by an approved central alarm station. Zoning and annunciation of central station alarm signals shall be submitted to the Fire Department for approval. e) Fire Protection Equipment shall be identified with approved signs constructed of durable materials, permanently installed and readily visible. 48. Fire Alarm System Required A Fire Alarm-Detection System shall be installed throughout the building so as to provide full property protection, including combustible concealed spaces, as required by NFPA 72. The system shall be installed in accordance with NFPA 72, CA Fire, Building, Electrical, and Mechanical Codes. If the system is intended to serve as an evacuation system, compliance with the horn/strobe requirements for the entire building must also be met. All automatic fire extinguishing systems shall be interconnected to the fire alarm system so as to activate an alarm if activated and to monitor control valves. Delayed egress locks shall meet requirements of C.F.C. Fire Alarm Plans. (Deferred Submittal Item). Submit detailed drawings of the fire alarm system, including floor plan showing all rooms, device locations, ceiling height and construction, cut sheets, listing sheets and battery and voltage drop calculations to the Fire Department for review and permit prior to the installation. Where employee work areas have audible alarm coverage, circuits shall be initially designed with a minimum 20% spare capacity for adding appliances to accommodate hearing impaired employee’s. b) Central Station Monitored Account. Automatic fire alarm systems shall be monitored by an approved central alarm station. Zoning and F Occupancy Reso. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 13 of 34 annunciation of central station alarm signals shall be approved by the Fire Department. c) Qualified Personnel. The system shall be installed, inspected, tested, and maintained in accordance with the provisions of NFPA 72. Only qualified and experienced persons shall perform this work. Examples of qualified individuals are those who have been factory trained and certified or are NICET Fire Alarm Certified. d) Inspection & Testing Documentation. Performance testing of all initiating & notification devices in the presence of the Fire Inspector shall occur prior to final of the system. Upon this inspection, proof that the specific account is UL Certificated must be provided to the Fire Inspector. 49. Fire Access During Construction. a) Fire Access. Access roads, turnaround, pullouts, and fire operation areas are fire lanes and shall be maintained clear and free of obstructions, including the parking of vehicles. b) Entrances. Entrances to job sites shall not be blocked, including after hours, other than by approved gates/barriers that provide for emergency access. c) Site Utilities. Site utilities that would require the access road to be dug up or made impassible shall be installed prior to construction commencing. d) Entrance flare, angle of departure, width, turning radii, grades, turnaround, vertical clearances, road surface, bridges/crossings, gates/key- switch, within a 150-foot distance to Fire Lane shall be maintained. e) Personnel Access. Route width, slope, surface and obstructions must be considered for the approved route to furthermost portion of the exterior wall. f) All-Weather Access. Fire access is required to be all-weather access. Show on the plans the location of the all-weather access and a description of the construction. Access roads must be designed to support the imposed loads of fire apparatus. F During Construction 50. Fire Extinguishers. Extinguishers shall be visible and unobstructed. Signage shall be provided to indicate fire extinguisher locations. The number and location of extinguishers shall be shown on the plans. Additional fire extinguishers maybe required by the fire inspector. F Occupancy Reso. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 14 of 34 Fire extinguisher shall meet a minimum classification of 2A 10BC. Extinguishers weighing 40 pounds or less shall be mounted no higher than five (5) feet above the floor measured to the top of the extinguisher. Extinguishers shall be inspected monthly and serviced by a licensed concern annually. 51. FD Building Key Box. Building Access. A Fire Department Key Box shall be installed at the main entrance to the Building. Note these locations on the plans. The key box should be installed approximately 5 1/2 feet above grade. The box shall be sized to hold the master key to the facility as well as keys for rooms not accessible by the master key. Specialty keys, such as the fire alarm control box key and elevator control keys shall also be installed in the box. The key box door and necessary keys are to be provided to the fire inspector upon the final inspection. The inspector will then lock the keys into the box. F Occupancy 52. Means of Egress. Exit signs shall be visible and illuminated with emergency lighting when building is occupied. F Occupancy 53. Maximum Occupant Load. Posting of room capacity is required for any occupant load of 50 or more persons. Submittal of a seating plan on 8.5” x 11” paper is required prior to final occupancy. F Occupancy 54. Interior Finish. Wall and ceiling interior finish material shall meet the requirements of Chapter 8 of the California Fire Code. Interior finishes will be field verified upon final inspection. If the product is not field marked and the marking visible for inspection, maintain the products cut-sheets and packaging that show proof of the products flammability and flame-spread ratings. Decorative materials shall be fire retardant. F Occupancy 55. General Inspection. Upon inspection of the work for which this submittal was provided, a general inspection of the business and site will be conducted. F Occupancy 56. Addressing. Addressing shall be illuminated or in an illuminated area. The address characters shall be contrasting to their background. If address is placed on glass, the numbers shall be on the exterior of the glass and a contrasting background placed behind the numbers. Building Address. The building shall be provided with all addresses or the assigned address range so as to be clearly visible from either direction of travel on the street the address references. The address characters shall not be less than 5 inches in height by 1-inch F Occupancy of any building Reso. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 15 of 34 stroke. Larger sizes may be necessary depending on the setbacks and visibility. Multi-Tenants. Where a building has multiple tenants, address shall also be provided near the main entrance door of each tenant space. The address shall be high enough on the building to be clearly visible from the driveway, street or parking area it faces even when vehicles are parked in front of the tenant space. The address shall not be less than 5-inches in height with a ½-inch stroke. Rear Doors. The address shall also be provided on any rear doors to the tenant space with minimum 5- inch-high characters. Entrance Posting. Where the addressing on the building will not be clearly visible from either direction of travel along the access road the address references. Address posting shall also be provided at the entrance to the property. The address size shall be 5-inches high and should be on a reflective background. 57. FIRE SAFETY DURING CONSTRUCTION AND DEMOLITION A. Clearance to combustibles from temporary heating devices shall be maintained. Devices shall be fixed in place and protected from damage, dislodgement or overturning in accordance with the manufacturer’s instructions. B. Smoking shall be prohibited except in approved areas. Signs shall be posted “NO SMOKING” in a conspicuous location in each structure or location in which smoking is prohibited. C. Combustible debris, rubbish and waste material shall be removed from buildings at the end of each shift of work. D. Flammable and combustible liquid storage areas shall be maintained clear of combustible vegetation and waste materials. F Ongoing during construction and demolition PUBLIC WORKS – GENERAL CONDITIONS 58. Conditions of Approval. Applicant/Developer shall comply with the City of Dublin Public Works Standard Conditions of Approval contained below (“Standard Condition”) unless specifically modified by Project Specific Conditions of Approval below. PW On-going 59. Compliance. Applicant/Developer shall comply with the City of Dublin Zoning Ordinances, City of Dublin Title 7 Public Works Ordinance, which includes the Grading Ordinance, the City of Dublin Public Works Standards and Policies, the most current requirements of the State PW On-going Reso. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 16 of 34 Code Title 24 and the Americans with Disabilities Act with regard to accessibility, and all building and fire codes and ordinances in effect at the time of building permit. All public improvements constructed by Applicant/Developer and to be dedicated to the City are hereby identified as “public works” under Labor Code Section 1771. Accordingly, Applicant/Developer, in constructing such improvements, shall comply with the Prevailing Wage Law (Labor Code § 1720 et seq.). 60. Clarifications and Changes to the Conditions. In the event that there needs to be clarification to these Conditions of Approval, the City Engineer has the authority to clarify the intent of these Conditions of Approval to the Applicant/Developer without going to a public hearing. The City Engineer also has the authority to make minor modifications to these conditions without going to a public hearing in order for the Applicant/Developer to fulfill needed improvements or mitigations resulting from impacts of this project. PW On-going 61. Hold Harmless/Indemnification. The Applicant/Developer shall defend, indemnify, and hold harmless the City of Dublin and its agents, officers, and employees from any claim, action, or proceeding against the City of Dublin or its advisory agency, appeal board, Planning Commission, City Council, Community Development Director, Zoning Administrator, or any other department, committee, or agency of the City to the extent such actions are brought within the time period required by Government Code Section 66499.37 or other applicable law: provided, however, that the Applicant/Developer’s duty to so defend, indemnify, and hold harmless shall be submitted to the City promptly notifying or proceeding and the City’s full cooperation in the defense of such actions or proceedings. PW On-going 62. Fees. The Applicant/Developer shall pay all applicable fees in effect at the time of building permit issuance, including, but not limited to: Planning fees; Building fees; Dublin San Ramon Services District fees; Alameda County Flood Control and Water Conservation District fees. Various Depts Grading Permit or Building Permit Issuance 63. Zone 7 Impervious Surface Fees. The Applicant/Developer shall complete a “Zone 7 Impervious Surface Fee Application” and submit an accompanying exhibit for review by the Public Works Department. Fees generated by this application will be due at issuance of Building Permit. PW Grading Permit or Building Permit Issuance PUBLIC WORKS – AGREEMENTS 64. Stormwater Management Maintenance Agreement. Developer or Property Owner shall enter into an Agreement with the City of Dublin that guarantees the PW Grading Permit or Building Reso. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 17 of 34 property owner’s perpetual maintenance obligation for all stormwater management measures installed as part of the project, including those on-site and within the public Rights of Way. In addition to stormwater management measures, drainage v-ditches, mitigation areas, and existing wetlands shall be included for reference, as applicable. Said Agreement is required pursuant to Provision C.3 of the Municipal Regional Stormwater NPDES Permit, Order No. R2-2022-0018. Said permit requires the City to provide verification and assurance that all treatment devices will be properly operated and maintained. The Agreement shall be recorded against the property and shall run with the land. Permit Issuance 65. Improvement Agreement. Applicant/Developer shall enter into an Improvement Agreement with the City for all public improvements including any required offsite storm drainage or roadway improvements that are needed to serve the development, as determined by the City Engineer. PW Grading Permit or Building Permit or Encroachment Permit Issuance PUBLIC WORKS – PERMITS AND BONDS 66. Encroachment Permit. Applicant/Developer shall obtain an Encroachment Permit from the Public Works Department for all construction activity within the public right-of-way. At the discretion of the City Engineer an encroachment permit for work specifically included in an Improvement Agreement may not be required. PW Permit Issuance 67. Grading Permit. Applicant/Developer shall obtain a Grading Permit from the Public Works Department for all grading. PW Permit Issuance 68. Security. Applicant/Developer shall provide faithful performance security to guarantee the improvements, as well as payment security, as determined by the City Engineer (Note: The performance security shall remain in effect until one year after final inspection). PW Permit Issuance 69. Permits from Other Agencies. Applicant/Developer shall obtain all permits and/or approvals required by other agencies including, but not limited to: Regional Water Quality Control Board Dublin San Ramon Services District (DSRSD) PW Permit Issuance PUBLIC WORKS – SUBMITTALS 70. Improvement Plan Submittal Requirements. All submittals of plans shall comply with the requirements of the “City of Dublin Public Works Department Improvement Plan Submittal Requirements”, the “City of Dublin Improvement Plan Review Check List,” and current Public Works and industry standards. A complete submittal of improvement plans shall include PW Grading Permit Issuance Reso. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 18 of 34 all civil improvements, joint trench, street lighting and on- site safety lighting, landscape plans, and all associated documents as required. Applicant/Developer shall not piecemeal the submittal by submitting various components separately. 71. Improvement Plan Requirements from Other Agencies. Applicant/Developer will be responsible for submittals and reviews to obtain the approvals of all participating non-City agencies, including but not limited to: the Alameda County Fire Department and the Dublin San Ramon Services District. PW Grading Permit Issuance 72. Composite Exhibit. Construction plan set shall include a Composite Exhibit showing all site improvements, utilities, landscaping improvements and trees, etc. to be constructed to ensure that there are no conflicts among the proposed and existing improvements. PW Grading Permit Issuance 73. Geotechnical Report. Applicant/Developer shall submit a Design Level Geotechnical Report, which includes street pavement sections, grading and additional information and/or clarifications as determined by the City Engineer. PW Grading Permit Issuance 74. Ownership and Maintenance of Improvements. Applicant/Developer shall submit an Ownership and Maintenance Exhibit for review and approval by Planning Division and Public Works Department. Terms of maintenance are subject to review and approval by the City Engineer. PL, PW Grading Permit Issuance 75. Building Pads, Slopes and Walls. Applicant/Developer shall provide the Public Works Department with a letter from a registered civil engineer or surveyor stating that the building pads have been graded to within 0.1 feet of the grades shown on the approved Grading Plans, and that the top & toe of banks and retaining walls are at the locations shown on the approved Grading Plans. PW Acceptance of Improvements 76. Approved Plan Files. Applicant/Developer shall provide the Public Works Department a PDF format file of approved site plans, including grading, improvement, landscaping & irrigation, joint trench and lighting. PW Grading Permit Issuance 77. Master Files. Applicant/Developer shall provide the Public Works Department a digital vectorized file of the “master” files for the project, in a format acceptable to the City Engineer. Digital raster copies are not acceptable. The digital vectorized files shall be in AutoCAD 14 or higher drawing format. All objects and entities in layers shall be colored by layer and named in English. All submitted drawings shall use the Global Coordinate System of USA, California, NAD 83 California State Plane, Zone III, and U.S. foot. PW Acceptance of Improvements Reso. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 19 of 34 78. Environmental Services Files. Applicant/Developer shall provide to the Public Works Department GIS shape files, provided in a format acceptable to the City, all MRP Provision C.3 stormwater features, trash capture devices, mitigation measures, wetlands, v-ditches and public waste containers. PW/ESD Acceptance of Improvements 79. SB 1383 Compliance Reporting. To comply with SB 1383, applicant shall provide to the Public Works Department records indicating where SB 1383 compliant mulch or compost was applied in the project, the source and type of product, quantity of each product, and invoices demonstrating procurement. PW/ESD Acceptance of Improvements / building occupancy PUBLIC WORKS – EASEMENTS AND ACCESS RIGHTS 80. Dedications. Applicant shall dedicate all rights-of-way and easement dedications required by these conditions or determined necessary by the City Engineer. PW Improvement Plan Approval 81. Public Service Easements. A Public Service Easement (PSE) shall be dedicated along the project’s frontage to allow for the proper placement of public utility vaults, boxes, appurtenances or similar items behind the back-of-sidewalk. Private improvements such as fences, gates or trellises shall not be located within the PSE. PW Improvement Plan Approval 82. Emergency Vehicle Access Easements. The Applicant/Developer shall dedicate Emergency Vehicle Access Easements (EVAE) over the clear pavement width of all drive aisles as required by the Alameda County Fire Department and City Engineer. PW Improvement Plan Approval 83. Abandonment of Easements. Applicant/Developer shall obtain abandonment from all applicable public agencies of existing easements and rights-of-way within the project site that will no longer be used. Prior to completion of abandonment, the improvement plans may be approved if the Applicant/Developer can demonstrate to the satisfaction of the City Engineer that the abandonment process has been initiated. PW Improvement Plan Approval 84. Acquisition of Easements. Applicant/Developer shall be responsible for obtaining all onsite and offsite easements, and/or obtain rights-of-entry from the adjacent property owners for any improvements not located on their property. The Applicant/Developer shall prepare all required documentation for dedication of all easements on-site and off-site. The easements and/or rights-of-entry shall be in writing and copies furnished to the Public Works Department. PW Improvement Plan Approval 85. Approval by Others. The Applicant/Developer will be responsible for submittals and reviews to obtain the approvals of all applicable non-City agencies. PW Improvement Plan Approval PUBLIC WORKS – GRADING Reso. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 20 of 34 86. Grading Plan. The Grading Plan shall be in conformance with the recommendation of the Geotechnical Report, the approved Site Development Review, and the City design standards & ordinances. In case of conflict between the soil engineer’s recommendation and the City ordinances, the City Engineer shall determine which shall apply. PW Grading Permit Issuance 87. Geotechnical Engineer Review and Approval. The Project Geotechnical Engineer shall be retained to review all final grading plans and specifications. The Project Geotechnical Engineer shall approve all grading plans prior to City approval. PW Grading Permit Issuance/ Sitework Permit 88. Grading Off-Haul. The disposal site and haul truck route for any off-haul dirt materials shall be subject to review and approval by the City Engineer prior to the issuance of a Grading Permit. If the Applicant/Developer does not own the parcel on which the proposed disposal site is located, the Applicant/Developer shall provide the City with a Letter of Consent signed by the current owner, approving the placement of off-haul material on their parcel. A Grading Plan may be required for the placement of the off-haul material. A Transportation Permit or Encroachment Permit may be required for the haul route, as determined by the City Engineer, which shall include a pre- and post-hauling survey of the pavement condition. Applicant/Developer shall be responsible for repairing damaged pavement due to hauling operations, as determined by the City Engineer. PW Grading Permit Issuance/ Sitework Permit 89. Erosion Control Plan. A detailed Erosion and Sediment Control Plan shall be included with the Grading Plan submittal. The plan shall include detailed design, location, and maintenance criteria of all erosion and sedimentation control measures. The plan shall also address site housekeeping best management practices. PW Grading Permit Issuance 90. Demolition Plan. The Applicant/Developer’s Civil Engineer shall prepare a demolition plan for the project, which shall be submitted concurrent with the improvement plan package. The demolition plan shall address the following: • Pavement demolition, including streetlights and landscaped median islands. • Landscaping and irrigation • Fencing to be removed and fencing to remain PW Grading Permit Issuance Reso. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 21 of 34 Any items to be saved in place and or protected, such as trees, water meters, sewer cleanouts, drainage inlets or backflow prevention devices. PUBLIC WORKS - STORM DRAINAGE & OTHER UTILITIES 91. On-site Storm Drain System. Storm drainage for the 10-year storm event shall be collected on-site and conveyed through storm drains to the public storm drain system. Show the size and location of existing and proposed storm drains and catch basins on the site plan. Show the size and location of public storm drain lines and the points of connection for the on-site storm drain system. PW Grading Permit Issuance 92. Overland Release. Grading and drainage shall be designed so that surplus drainage (above and beyond that of the 10-year storm event) not collected in site catch basins, is directed overland so as not to cause flooding of existing or proposed buildings. PW Grading Permit Issuance 93. Storm Drain Easements. Private storm drain easements and maintenance roads shall be provided for all private storm drains or ditches that are located on private property. The Applicant/Developer shall be responsible for the acquisition of all storm drain easements from offsite property owners which are required for the connection and maintenance of all offsite storm drainage improvements. PW Grading Permit Issuance 94. Storm Drain Inlet Markers. All public and private storm drain inlets must be marked with storm drain markers that read: “No dumping, drains to creek,” and a note shall be shown on the improvement plans. The markers may be purchased from the Public Work Department. PW Acceptance of Improvements 95. Fire Hydrants. Fire hydrant locations shall be approved by the Alameda County Fire Department. A raised reflector blue traffic marker shall be installed in the street opposite each hydrant, and shown on the signing & striping plan. PW Acceptance of Improvements 96. Dry Utilities. Applicant/Developer shall construct gas, electric, telephone, cable TV, and communication improvements within the fronting streets and as necessary to serve the project and the future adjacent parcels as approved by the City Engineer and the various Public Utility agencies. PW Certificate of Occupancy or Acceptance of Improvements 97. Dry Utility Locations. All electric, telephone, cable TV, and communications utilities, shall be placed underground in accordance with the City policies and ordinances. All utilities shall be located and provided within public utility easements or public services easements and sized to meet utility company standards. PW Certificate of Occupancy or Acceptance of Improvements 98. Utility Vaults and Boxes. All utility vaults, boxes, and structures, unless specifically approved otherwise by the City Engineer, shall be underground and placed in PW Certificate of Occupancy or Reso. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 22 of 34 landscaped areas and screened from public view. Landscape drawings shall be submitted to the City showing the location of all utility vaults, boxes, and structures and adjacent landscape features and plantings. The Joint Trench Plans shall be submitted along with the grading and/or improvement plans. Acceptance of Improvements PUBLIC WORKS- STREET IMPROVEMENTS 99. Public Improvements. The public improvements shall be constructed generally as shown on the Site Development Review. However, the approval of the Site Development Review is not an approval of the specific design of the drainage, traffic circulation, parking, stormwater treatment, sidewalks and street improvements. PW Grading Permit or Encroachment Permit Issuance 100. Public Improvement Conformance. All public improvements shall conform to the City of Dublin Standard Plans, current practices, and design requirements and as approved by the City Engineer. PW Grading Permit or Encroachment Permit Issuance 101. Pavement Structural Sections. Asphalt concrete pavement sections within the public right-of-way shall be designed using the Caltrans method for flexible pavement design (including the asphalt factor of safety), an assumed R-Value of 5. Final pavement sections shall be based on the actual R-Value obtained from pavement subgrade. PW Grading Permit or Encroachment Permit Issuance 102. Decorative Pavement. Any decorative pavers/paving installed within City right-of-way shall be done to the satisfaction of the City Engineer. Where decorative paving is installed at signalized intersections, pre- formed traffic signal loops shall be put under the decorative pavement. Decorative pavements shall not interfere with the placement of traffic control devices, including pavement markings. All turn lane stripes, stop bars and crosswalks shall be delineated with concrete bands or colored pavers to the satisfaction of the City Engineer. Maintenance costs of decorative paving installed within the public right-of-way along the project frontage shall be the responsibility of the Applicant/Developer or future property owner. PW Grading Permit or Encroachment Permit Issuance 103. Curb, Gutter & Sidewalk. Applicant/Developer shall remove and replace damaged, hazardous, or nonstandard curb, gutter and sidewalk along the project frontage. Contact the Public Works Department to mark the existing curb, gutter and sidewalk that will need to be removed and replaced. PW Grading Permit or Encroachment Permit Issuance 104. Curb Ramps. City standard curb ramps are required at all intersections. All curb ramps shall include truncated domes and meet the most current City and ADA design PW Grading Permit or Encroachment Reso. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 23 of 34 standards. Curb ramp locations shall be shown on the plans. Permit Issuance 105. Visibility Triangle. All improvements within the sight visibility triangle at all intersections, including but not limited to walls and landscaping, shall be a maximum height of 30” from the roadway surface elevation at the nearest lane. PW Grading Permit or Encroachment Permit Issuance 106. Traffic Signing and Striping. Applicant/Developer shall install all traffic signage, striping, and pavement markings as required by the City Engineer. Signing plans shall show street name and stop signs and any other regulatory signage appropriate for the project. Striping plans shall show stop bars, lane lines and channelization as necessary. Striping plans shall distinguish between existing striping to be removed and new striping to be installed. All striping shall be thermoplastic. PW Grading Permit or Encroachment Permit Issuance 107. Street Lighting. Street light standards and luminaries shall be designed and installed or relocated as determined by the City Engineer. PW Grading Permit or Encroachment Permit Issuance PUBLIC WORKS - CONSTRUCTION 108. Erosion Control Implementation. The Erosion and Sediment Control Plan shall be implemented between October 1st and April 30th unless otherwise allowed in writing by the City Engineer. The Applicant/Developer will be responsible for maintaining erosion and sediment control measures for one year following the City’s acceptance of the improvements. PW Start of Construction and On-going 109. Archaeological Finds. If archaeological materials are encountered during construction, construction within 100 ft of these materials shall be halted until a professional Archaeologist certified by the Society of California Archaeology (SCA) or the Society of Professional Archaeology (SOPA) has had an opportunity to evaluate the significance of the find and suggest appropriate mitigation measures. PW Start of Construction and On-going 110. Construction Activities. Construction activities, including the idling, maintenance, and warming up of equipment, shall be limited to Monday through Friday, and non-City holidays, between the hours of 7:30 a.m. and 6:00 p.m. except as otherwise approved by the City Engineer. Extended hours or Saturday work will be considered by the City Engineer on a case-by-case basis. Note that the construction hours of operation within the public right-of-way are more restrictive. PW Start of Construction and On-going 111. Temporary Fencing. Temporary construction fencing shall be installed along the construction work perimeter to separate the construction area from the public. All PW Start of Construction and On-going Reso. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 24 of 34 construction activities shall be confined within the fenced area. Construction materials and/or equipment shall not be operated/stored outside of the fenced area or within the public right-of-way unless approved in advance by the City Engineer. 112. Construction Noise Management Plan. Applicant/Developer shall prepare a construction noise management plan that identifies measures to minimize construction noise on surrounding developed properties. The plan shall include hours of construction operation, use of mufflers on construction equipment, speed limit for construction traffic, haul routes and identify a noise monitor. Specific noise management measures shall be provided prior to project construction. PW Start of Construction Implementatio n, and On- going as needed 113. Traffic Control Plan. Closing of any existing pedestrian pathway and/or sidewalk during construction shall be implemented through a City-approved Traffic Control Plan and shall be done with the goal of minimizing the impact on pedestrian circulation. PW Start of Construction and On-going as needed 114. Construction Traffic Interface Plan. Applicant/Developer shall prepare a plan for construction traffic interface with public traffic on any existing public street. Construction traffic and parking may be subject to specific requirements by the City Engineer. Lane Closures on Dublin Boulevard are only permitted between 9:00 a.m. – 3:30 p.m. PW Start of Construction; Implementatio n, and On- going as needed 115. Pest Control. Applicant/Developer shall be responsible for controlling any rodent, mosquito, or other pest problem due to construction activities. PW On-going 116. Dust Control Measures. Applicant/Developer shall be responsible for watering or other dust-palliative measures to control dust as conditions warrant or as directed by the City Engineer. PW Start of Construction; Implementatio n On-going as needed 117. Dust Control/Street Sweeping. The Applicant/Developer shall provide adequate dust control measures at all times during the grading and hauling operations. All trucks hauling export and import materials shall be provided with tarp cover at all times. Spillage of haul materials and mud-tracking on the haul routes shall be prevented at all times. The Applicant/Developer shall be responsible for sweeping of streets within, surrounding and adjacent to the project, as well as along the haul route, if it is determined that the tracking or accumulation of material on the streets is due to its construction activities. PW During Grading and Site Work 118. Construction Traffic and Parking. All construction- related parking shall be off-street in an area provided by the Applicant/Developer. Construction traffic and PW Start of Construction and On-going Reso. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 25 of 34 parking shall be provided in a manner approved by the City Engineer. PUBLIC WORKS – EROSION CONTROL & STORMWATER QUALITY 119. Stormwater Treatment. Consistent with Provision C.3 of the Municipal Regional Stormwater NPDES Permit (MRP) Order No. R2-2022-0018, the Applicant/Developer shall submit documentation including construction drawings demonstrating all stormwater treatment measures and hydromodification requirements as applicable are met. PW/ESD Grading Permit Issuance 120. Stormwater Source Control. All applicable structural and operational stormwater source controls shall be implemented. PW/ESD Grading/Sitew ork Permit Issuance 121. Maintenance Access. Applicant shall design and construct maintenance access to all stormwater management measures and mitigation swales, as appropriate. Maintenance access for equipment and personnel to overflow risers, cleanouts and other structures is required. The final number, location, width, and surfacing of maintenance access points from public or private streets is subject to the approval of the City Engineer. PW/ESD Grading Permit Issuance 122. Green Stormwater Infrastructure. The Applicant/Developer shall incorporate Green Infrastructure facilities within the public rights-of-way of newly constructed or widened streets, subject to the review of the Public Works Department. Green Stormwater Infrastructure facilities include, but are not limited to: infiltration basins, bioretention facilities, pervious pavements, etc. PW/ESD Grading Permit or Encroachment Permit Issuance 123. NOI and SWPPP. Prior to any clearing or grading, Applicant/Developer shall provide the City evidence that a Notice of Intent (NOI) has been sent to the California State Water Resources Control Board per the requirements of the NPDES. A copy of the Storm Water Pollution Prevention Plan (SWPPP) shall be provided to the Public Works Department and be kept at the construction site. PW Start of Any Construction Activities 124. SWPPP. The Storm Water Pollution Prevention Plan (SWPPP) shall identify the Best Management Practices (BMPs) appropriate to the project construction activities. The SWPPP shall include the erosion and sediment control measures in accordance with the regulations outlined in the most current version of the Association of Bay Area Governments (ABAG) Erosion and Sediment Control Handbook or State Construction Best Management Practices Handbook. The Applicant/Developer is responsible for ensuring that all contractors implement all storm water pollution prevention measures in the SWPPP. PW SWPPP to be Prepared Prior to Grading Permit Issuance; Implementatio n Prior to Start of Construction and On-going as needed Reso. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 26 of 34 125. Stormwater Management Plan. A final Stormwater Management Plan shall be submitted for review and approval by the City Engineer. Approval is subject to the Applicant/Developer providing the necessary plans, details, and calculations that demonstrate the plan complies with the standards issued by the San Francisco Bay Regional Water Quality Control Board and Alameda Countywide Clean Water Program. Landscape Based Stormwater Management Measures shall be irrigated, be on a separate irrigation controller from traditional landscape, and meet WELO requirements. PW/ESD Building Permit Issuance and Grading Permit Issuance 126. SB 1383 Compliance. To comply with SB 1383 procurement requirements, all mulch and compost used in stormwater management measures and general landscape areas shall meet SB 1383 procurement requirements. Specifically, compost must be produced at a permitted composting facility; digestate, biosolids, manure and mulch do not qualify as compost. Eligible mulch must be derived from organic materials and be produced at a permitted transfer station, landfill, or composting facility. Examples of allowed compost include arbor mulch and composted mulch. PW/ESD Building Permit Issuance and Grading Permit Issuance. 127. Trash Capture. The project must include appropriate full trash capture devices for both private and public improvements. Specific details on the trash capture devices selected are required on the construction plan set demonstrating how MRP Provision C.10 (trash capture) requirements are met. A list of approved full trash capture devices may be found at the California Stormwater Quality Association website at the following link: https://www.casqa.org/resources/trash/certified- full-capture-system-trash-treatment-control-devices. Please note that lead time for trash capture device delivery can be substantial. The applicant/contractor shall plan accordingly. PW Building Permit Issuance and Grading Permit Issuance 128. Phased Construction and Stormwater Management Measures. Required stormwater treatment, hydromodification management, and trash capture devices shall be installed concurrent with construction of the first phase of improvements. Temporary facilities are not permitted. PW/ESD Building Permit Issuance and Grading Permit Issuance PUBLIC WORKS – ONSITE IMPROVEMENTS 129. Drive Aisle Width. The parking lot aisles shall be a minimum of 24 feet wide to allow for adequate onsite vehicle circulation for cars, trucks, and emergency vehicles. PW Grading Permit Issuance 130. Vehicle Parking. All on-site vehicle parking spaces shall conform to the following: PW Grading Permit Issuance Reso. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 27 of 34 a. All parking spaces shall be double striped using 4” white lines set 2 feet apart in accordance with City Standards and DMC 8.76.070.A.17. b. 12”-wide concrete step-out curbs shall be constructed at each parking space where one or both sides abut a landscaped area or planter. c. Where wheel stops are shown, individual 6’ long wheel stops shall be provided within each parking space in accordance with City Standards. d. A minimum 2’ radius shall be provided at curb returns and curb intersections where applicable. e. Parking stalls next to walls, fences and obstructions to vehicle door opening shall be an additional 4’ in width per DMC 8.76.070.A.16. Landscaped strips adjacent to parking stalls shall be unobstructed in order to allow for a minimum 2-foot vehicular overhang at front of vehicles. 131. Traffic Management Plan. The applicant shall make necessary modification to the parking area or develop and implement an on-site traffic management plan to address any potential concerns that may be identified by site circulation review of the site for delivery vans and trucks. If an on-site traffic management plan is developed, it should be pre- approved by Public Works department. PW Building Permit Issuance and Grading Permit Issuance 132. Onsite Signing and Striping Plan. A Traffic Signing and Striping Plan showing all proposed signing and striping within on-site parking lots and drive aisles, shall be submitted for review and approval by the City Engineer. PW Grading Permit or Encroachment Permit Issuance 133. Photometrics. The Applicant/Developer shall provide a complete photometrics plan for both onsite and frontage roadways. Include the complete data on photometrics, including the High, Average and Minimum values for illuminance and uniformity ratio. PW Grading Permit or Encroachment Permit Issuance 134. Project signs. All proposed project monument signs shall be placed on private property. Signs should be located outside of any easement areas unless specifically approved by the City Engineer. Any signage allowed to be located in an easement is subject to removal and replacement at the expense of the Developer/property owner if required by the easement holder. PW Grading Permit Issuance 135. Solid Waste Requirements. The Project must comply with all requirements in Dublin Municipal Code Chapter 7.98, including the following requirements: Install trash, recycling and organics collection containers at the entrance and exit of the property. PW/ESD Building Permit or Site Work Permit Issuance Reso. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 28 of 34 136. Cigarette Butt Collection. Install and appropriately site cigarette butt collection containers for employee and public use. PW/ESD Building Permit or Site Work Permit Issuance 137. Garbage Truck Access. The applicant shall provide plans and details on anticipated garbage truck access and routes, in addition to example set-out diagrams for waste carts/bins placement on garbage day demonstrating adequate space available for carts/bins. Carts and bins shall not block street or driveway access. PW/ESD Building Permit or Site Work Permit Issuance PUBLIC WORKS - SPECIAL CONDITIONS 138. Corrective Grading Plan. The Geotechnical Report identifies areas of undocumented fill which shall be removed and replaced with engineered fill. The Applicant shall provide corrective grading plans for removal and replacement of soil. The Public Works Department may issue a separate grading permit for this work. PW Grading Permit Issuance 139. Access Easement. The Applicant shall dedicate an access easement from the public right-of-way at Dublin Boulevard to the existing City maintained storm drain line located near the south side of the property, to allow the City maintenance access through the project site to the storm drain line. PW Improvement Plan Approval 140. Public Sidewalk Easement. The Applicant shall dedicate a public sidewalk easement behind the public right-of-way at Dublin Boulevard where the proposed public sidewalk extends outside the right-of-way and onto private property. PW Improvement Plan Approval 141. Easement Vacation. An existing easement is located within the parcel that will be in conflict with the location of the proposed building. The project shall provide documentation to the City as needed for the existing easement to be vacated. Vacation of the easement will be required through the City Council process. PW Building Permit Issuance 142. Parking Lot Slopes. Slopes shall not exceed 5% in parking lot areas. PW Improvement Plan Approval 143. Adjacent Properties. The Applicant is responsible to obtain written authorization from adjacent property owners for any access needed through adjacent properties, and any grading and improvements on adjacent properties. A copy of written authorizations shall be submitted to the Public Works Department prior to start of any work. PW Grading Permit or Building Permit Issuance 144. Traffic Study. The Applicant shall comply with the findings and recommendations of the traffic study, including but not limited to maintaining the landscaping to provide the minimum sight distance for vehicles exiting the project site and providing signage instructing PW Improvement Plan Approval Reso. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 29 of 34 drivers of trucks and other large vehicles that access into the project site is prohibited from the eastern driveway. 145. Public Sidewalk. The project shall provide a 10-foot- wide sidewalk separated from the curb by a 5-foot landscape/amenities strip per Dublin Village Historic Area Specific Plan along the project frontage at Dublin Boulevard, between the two driveways serving the site. PW Improvement Plan Approval 146. Bicycle Lane at Dublin Boulevard. The Applicant shall provide a 6-foot-wide bicycle lane with a 2-foot-wide buffer at Dublin Boulevard along the project frontage. PW Improvement Plan Approval 147. Bicycle Parking. The Applicant shall provide 12 short- term bicycle parking spaces and 12 long-term bicycle parking spaces onsite. PW Building Permit Issuance and Grading Permit Issuance 148. Landscape Features within Public Right-of-Way. The Property Owner shall enter into an “Agreement for Long Term Encroachment for Landscape Features” with the City to require the Property Owner to maintain the sidewalk, landscape, irrigation and any decorative features within public right-of-way along the project frontage, including but not limited to any decorative pavements, stormwater treatments and trash capture devices. The Agreement shall identify the ownership of the special features and maintenance responsibilities. The Property Owner will be responsible for maintaining the surface of all decorative pavements including restoration required as the result of utility repairs. PW Grading Permit or Encroachment Permit Issuance 149. Stormwater Management Report. Provide a Stormwater Management Report including narrative of existing and proposed conditions, explaining how stormwater treatment, hydromodification and trash capture requirements are being met. The report shall also include exhibits, plans and sizing calculations. PW/ESD Building Permit Issuance and Grading Permit Issuance 150. Bubble-Up Structures. Bubble-ups are discouraged. If bubble-ups are needed, they shall be placed outside of the bioretention area (e.g. adjacent to the stormwater treatment facility, not in the treatment soil). PW/ESD Approval of Improvement Plans 151. Irrigation at Stormwater Treatment Areas. Stormwater treatment areas are required to be irrigated, be on a separate irrigation controller from the traditional landscape, and meet WELO requirements. PW/ESD Approval of Improvement and Landscape Plans 152. ReScape California Landscape Design. All publicly owned landscape (e.g. parks, right of way, etc.) shall be designed and rated to meet ReScape standards. The applicant is encouraged to design all other landscape areas according to ReScape Landscape standards. PW/ESD Building Permit Issuance and Grading Permit Issuance Reso. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 30 of 34 153. Street Restoration. A pavement treatment, such as slurry seal or grind and overlay, will be required within the public streets fronting the site as determined by the Public Works Department. The type and limits of the pavement treatment shall be determined by the City Engineer based upon the number and proximity of trench cuts, extent of frontage and median improvements, extent of pavement striping and restriping, excessive wear and tear/damage due to construction traffic, etc. PW Certificate of Occupancy or Acceptance of Improvements 154. Overhead Utilities. Existing overhead utilities shall be placed underground as generally shown on the approved Site Development Plans. All new utilities shall be placed underground. PW Grading Permit or Encroachment Permit Issuance 155. Hydromodification Management Standards. This project is subject to hydromodification management measures. The Applicant/Developer shall review the Bay Area Hydrology Model (BAHM) Review Worksheet for all projects that must meet Hydromodification Management Standards. The worksheet is available on the City’s website at the following webpage: http://dublin.ca.gov/1656/ PW Grading Permit or Encroachment Permit Issuance 156. Waste Enclosure. The waste enclosure shall meet all of the requirements set forth within the Dublin Municipal Code Section 7.98, including but not limited to providing sewer and water hook-ups. The improvement plans and/or building permit plans shall show additional information demonstrating these requirements are met. A standard plan for the waste enclosure can be downloaded at https://dublin.ca.gov/341/Standard- Plans in the “Stormwater Measures” section. A pedestrian accessible path of travel shall be provided for employees from the building to the waste enclosure in conformance with current accessibility requirements. PW/ESD Building Permit Issuance and Grading Permit Issuance 157. PCBs Demolition Ordinance. The applicant shall provide all screening and testing forms required to comply with the Chapter 7.29 of the Dublin Municipal Code, Management of Polychlorinated Biphenyls during the Building Demolition Process. Forms and additional resources may be found at https://dublin.ca.gov/2113/PCBs-Building-Demolition- Ordinance. PW/ESD Prior to issuance of Demolition Permit 158. Mitigation Measures. The applicant shall provide to the Planning Division and the Public Works Department a copy of the mitigation measures maintenance manual and schedule for reference, including maintenance procedures and protocols to follow after mitigation reporting is complete. PW/ESD Acceptance of Improvements Reso. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 31 of 34 159. Fair Share Contribution. The Applicant shall pay a fair share contribution in the amount of $210,000 towards the construction of a 12-foot wide Class I trail and a 5- foot wide buffer from the roadway on the north side of Dublin Boulevard between Silvergate Drive and Hansen Drive along the project frontage. PW Building Permit Issuance 160. Traffic Signal Modification. The Applicant shall coordinate with the City for traffic signal modifications including signal pole upgrades at the northeast and southwest corners, ADA compliant pedestrian push buttons, pedestrian countdown signal heads, appropriate vehicle signal heads to provide north-south split phasing, 2 Iteris vehicle detection cameras for Dublin Boulevard approaches, and project entry driveway conductor loops at the intersection of Dublin Boulevard and Hansen Drive, as generally shown on the approved SDR plans, to the satisfaction of the City Traffic Engineer. PW Improvement Plan Approval DUBLIN SAN RAMON SERVICES DISTRICT 161. Regulations that apply to development projects. The regulations that apply to development projects are codified in: the Dublin San Ramon Services District Code; the DSRSD “Standard Procedures, Specifications and Drawings for Design and Installation of Water and Wastewater Facilities” as amended from time to time; all applicable DSRSD Master Plans and all DSRSD policies. Prior to issuance of any building permit, complete improvement plans shall be submitted to DSRSD that conform to the pertinent documents. DSRSD Building Permit Issuance 162. Fees. Planning and review fees, inspection fees, and fees associated with a wastewater discharge permit shall be paid to DSRSD in accordance with the rates and schedules and at time of payment as established in the DSRSD Code. Planning and review fees are due after the 1st submittal of plans. Construction Permit and Inspection Fees are due prior to the issuance of a Construction Permit. Capacity Reserve Fees are due before the water meter can be set or the connection to the sewer system. DSRSD Permit Submittal and Construction Permit Issuance 163. District Review and Acceptance. Prior to issuance of any building permit by the City; or any Building Permit or Construction Permit by the Dublin San Ramon Services District, all improvement plans for DSRSD facilities shall be signed by the District Engineer. Each drawing of improvement plans for DSRSD facilities shall contain a signature block for the District Engineer indicating approval of the sanitary sewer and/or water facilities shown. Prior to approval by the District Engineer, the applicant shall pay all required DSRSD fees, and provide an engineer’s estimate of construction costs for the DSRSD Building Permit Issuance or Construction Permit Issuance Reso. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 32 of 34 sewer and water systems, a faithful performance bond, and a comprehensive general liability insurance policy in the amounts and forms that are acceptable to DSRSD. The applicant shall allow at least 15 working days for final improvement drawing review by DSRSD before signature by the District Engineer. 164. Easements. All easement dedications for DSRSD facilities shall be by separate instrument irrevocably offered to DSRSD or by offer of dedication on the Final Map. Prior to approval by the City for Recordation, the Final Map shall be submitted to and approved by DSRSD for easement locations, widths, and restrictions. DSRSD Building Permit Issuance or Construction Permit Issuance 165. Installation in Main Thoroughfares. Where the narrow width of a proposed alley or cul-de-sac is so restrictive that the standard separation requirements for water mains and sewer mains cannot be maintained, the water and sewer mains shall be installed within main thoroughfares, outside of alleyways or cul-de-sacs. Water and sewer mains may not be installed within courtyards. Water meters shall be installed around the outer perimeter of buildings. Installation of water lines from the meter to each unit shall be documented and submitted to the District. DSRSD Building Permit Issuance or Construction Permit Issuance 166. Provide Sufficient Capacity. All mains shall be sized to provide sufficient capacity to accommodate future flow demands in addition to each development project's demand. Layout and sizing of mains shall be in conformance with DSRSD utility master planning. DSRSD Approval of Improvement Plans 167. Submission of Proposed Easements. Prior to approval by the City of a grading permit or a site development permit, the locations and widths of all proposed easement dedications for water and sewer lines shall be submitted to and approved by DSRSD. DSRSD Grading Permit Issuance 168. Locate facilities in public streets. Water and sewer mains shall be located in public streets rather than in off- street locations to the fullest extent possible. If unavoidable, then sewer or water easements must be established over the alignment of each sewer or water main in an off-street or private street location to provide access for future maintenance and/or replacement. DSRSD Approval of Improvement Plans 169. Looped or Interconnect Pipelines. Domestic and fire protection waterline systems for Tracts or Commercial Developments shall be designed to be looped or interconnected to avoid dead end sections in accordance with requirements of the DSRSD Standard Specifications and sound engineering practice. DSRSD Approval of Improvement Plans 170. Sewers to operate by gravity flow. Sewers shall be designed to operate by gravity flow to DSRSD’s existing sanitary sewer system. Pumping of sewage is discouraged and may only be allowed under extreme DSRSD Approval of Improvement Plans Reso. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 33 of 34 circumstances following a case by case review with DSRSD staff. Any pumping station will require specific review and approval by DSRSD of preliminary design reports, design criteria, and final plans and specifications. The DSRSD reserves the right to require payment of present worth 30 year operations and maintenance costs as well as other conditions within a separate agreement with the applicant for any project that requires a pumping station. 171. Water and/or Sewer Capacity Demands. This project will be analyzed by DSRSD to determine if it represents additional water and/or sewer capacity demands on the District. Applicant will be required to pay all incremental capacity reserve fees for water and sewer services as required by the project demands. All capacity reserve fees must be paid prior to installation of a water meter for water. If a water meter is not required, the capacity reserve fee shall be paid prior to issuance of a building permit. The District may not approve the building permit until capacity reserve fees are paid. DSRSD Building Permit Issuance or Construction Permit Issuance 172. Obtain Permit to Construct. No sewer line or waterline construction shall be permitted unless the proper utility construction permit has been issued by DSRSD. A construction permit will only be issued after all of the items in Condition No. 2 have been satisfied. DSRSD Building Permit Issuance or Construction Permit Issuance 173. Backflow Prevention Devices/Double Detector Check Valves. Above ground backflow prevention devices/double detector check valves shall be installed on fire protection systems connected to the DSRSD water main. The applicant shall collaborate with the Fire Department and with DSRSD to size and configure its fire system. DSRSD Approval of Improvement Plans 174. Recycled Water Improvements. Improvement plans shall include recycled water improvements as required by DSRSD. Services for landscape irrigation shall connect to recycled water mains. Applicant must obtain a copy of the DSRSD Recycled Water Use Guidelines and conform to the requirements therein. Availability of Recycled Water to be determined by District. DSRSD Approval of Improvement Plans 175. General Condition. Fire hydrants shall not be located behind a backflow prevention device and shall be connected directly to a DSRSD water main. DSRSD Approval of Improvement Plans 176. Trash Enclosures. If trash enclosures are required to drain to the sanitary sewer system, grease interceptors shall be connected downstream of the drain and installed near the trash enclosure area. The trash enclosure shall be roofed and graded to minimize rainwater or stormwater from entering the drain within the trash enclosure. DSRSD Building Permit Issuance or Construction Permit Issuance Reso. No. XX-24, Item X.X, Adopted XX/XX/2024 Page 34 of 34 PASSED, APPROVED AND ADOPTED this __th day of _______ 2024, by the following vote: AYES: NOES: ABSENT: ABSTAIN: ______________________________ Mayor ATTEST: _________________________________ City Clerk 5555153.2 ON L Y VAN PARKINGNO PARKINGNO PARKINGNO VAN VAN ON L Y E V C H A R G I N G VAN ON L Y E V C H A R G I N G PARKINGNOONLY EV CHARGING E V C H A R G I N G ONLY EV CHARGING ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV CHARGING AMBULATORY ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G Project: Consultants: Project Number: Revision: Date: Drawn by: Title: Sheet: C I V I L STRUCTURAL MECHANICAL PLUMBING ELECTRICAL LANDSCAPE SOILS ENGINEER FIRE PROTECTION - K&W - - - Green Design - - 11711 DUBLIN BLVD. DUBLIN, CA Developer tel: 949 862 2113 email: hpa@hparchs.com 94610 oakland, ca 600 grand ave, suite 302 hpa, inc. 21657 JV 10/07/2022 19700 Vermont Ave. Suite 101 Torance, CA 90502 DUBLIN BOULEVARD OWNER, LP OVERALL SITE PLAN DAB-A1.1 SITE PLAN GENERAL NOTES SITE PLAN KEYNOTES SITE PLAN GENERAL NOTES TABULATION CODE ANALYSIS : AERIAL MAP SITE ON L Y VAN PARKINGNO PARKINGNO PARKINGNO VAN VAN ON L Y E V C H A R G I N G VAN ON L Y E V C H A R G I N G PARKINGNOONLY EV CHARGING E V C H A R G I N G ONLY EV CHARGING ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV CHARGING AMBULATORY ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G Project: Consultants: Project Number: Revision: Date: Drawn by: Title: Sheet: C I V I L STRUCTURAL MECHANICAL PLUMBING ELECTRICAL LANDSCAPE SOILS ENGINEER FIRE PROTECTION - K&W - - - Green Design - - 11711 DUBLIN BLVD. DUBLIN, CA Developer tel: 949 862 2113 email: hpa@hparchs.com 94610 oakland, ca 600 grand ave, suite 302 hpa, inc. 21657 JV 10/07/2022 19700 Vermont Ave. Suite 101 Torance, CA 90502 DUBLIN BOULEVARD OWNER, LP FIRE ACCESS ROUTE DAB-A1.1F SITE PLAN GENERAL NOTES PARKINGNO VAN PARKINGNO VANVAN PARKINGNOONLY EV CHARGING ONLY EV CHARGING ONLY EV CHARGING AMBULATORY Project: Consultants: Project Number: Revision: Date: Drawn by: Title: Sheet: C I V I L STRUCTURAL MECHANICAL PLUMBING ELECTRICAL LANDSCAPE SOILS ENGINEER FIRE PROTECTION - K&W - - - Green Design - - 11711 DUBLIN BLVD. DUBLIN, CA Developer tel: 949 862 2113 email: hpa@hparchs.com 94610 oakland, ca 600 grand ave, suite 302 hpa, inc. 21657 JV 10/07/2022 19700 Vermont Ave. Suite 101 Torance, CA 90502 DUBLIN BOULEVARD OWNER, LP ENLARGED SITE PLAN DAB-A1.2 SITE PLAN GENERAL NOTES SITE PLAN KEYNOTES SITE PLAN GENERAL NOTES Project: Consultants: Project Number: Revision: Date: Drawn by: Title: Sheet: C I V I L STRUCTURAL MECHANICAL PLUMBING ELECTRICAL LANDSCAPE SOILS ENGINEER FIRE PROTECTION - K&W - - - Green Design - - 11711 DUBLIN BLVD. DUBLIN, CA Developer tel: 949 862 2113 email: hpa@hparchs.com 94610 oakland, ca 600 grand ave, suite 302 hpa, inc. 21657 JV 10/07/2022 19700 Vermont Ave. Suite 101 Torance, CA 90502 DUBLIN BOULEVARD OWNER, LP OVERALL FLOOR PLAN DAB-A2.1 KEYNOTES - FLOOR PLAN GENERAL NOTES - FLOOR PLAN Project: Consultants: Project Number: Revision: Date: Drawn by: Title: Sheet: C I V I L STRUCTURAL MECHANICAL PLUMBING ELECTRICAL LANDSCAPE SOILS ENGINEER FIRE PROTECTION - K&W - - - Green Design - - 11711 DUBLIN BLVD. DUBLIN, CA Developer tel: 949 862 2113 email: hpa@hparchs.com 94610 oakland, ca 600 grand ave, suite 302 hpa, inc. 21657 JV 10/07/2022 19700 Vermont Ave. Suite 101 Torance, CA 90502 DUBLIN BOULEVARD OWNER, LP ROOF PLAN DAB-A2.10 Project: Consultants: Project Number: Revision: Date: Drawn by: Title: Sheet: C I V I L STRUCTURAL MECHANICAL PLUMBING ELECTRICAL LANDSCAPE SOILS ENGINEER FIRE PROTECTION - K&W - - - Green Design - - 11711 DUBLIN BLVD. DUBLIN, CA Developer tel: 949 862 2113 email: hpa@hparchs.com 94610 oakland, ca 600 grand ave, suite 302 hpa, inc. 21657 JV 10/07/2022 19700 Vermont Ave. Suite 101 Torance, CA 90502 DUBLIN BOULEVARD OWNER, LP ELEVATION DAB-A3.1 GENERAL NOTES - ELEVATIONS ELEVATION COLOR LEGEND/SCHED. GLAZING LEGEND KEYNOTES - ELEVATIONS Project: Consultants: Project Number: Revision: Date: Drawn by: Title: Sheet: C I V I L STRUCTURAL MECHANICAL PLUMBING ELECTRICAL LANDSCAPE SOILS ENGINEER FIRE PROTECTION - K&W - - - Green Design - - 11711 DUBLIN BLVD. DUBLIN, CA Developer tel: 949 862 2113 email: hpa@hparchs.com 94610 oakland, ca 600 grand ave, suite 302 hpa, inc. 21657 JV 10/07/2022 19700 Vermont Ave. Suite 101 Torance, CA 90502 DUBLIN BOULEVARD OWNER, LP DETAILS DAB-A4.1 DUBLIN BOULEVARD HIGH W A Y 5 8 0 DUBLIN BOULEVARD HIGH W A Y 5 8 0 UNIT A UNIT B UNIT C UNIT D ON L Y VAN PARKINGNO PARKINGNO PARKINGNO VAN VAN ON L Y E V C H A R G I N G VAN ON L Y E V C H A R G I N G PARKINGNOONLY EV CHARGING E V C H A R G I N G ONLY EV CHARGING ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV CHARGING AMBULATORY ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G DUBLIN BOULEVARD OWNER, LPFOR11711 DUBLIN BLVDOFPRELIMINARY SITE IMPROVEMENT PLANS GENERAL NOTES DUBLIN,CALIFORNIA VICINITY MAP R Call before you dig. below.Know what's SITE MAP SHEET DESCRIPTION NO.CIVIL 1 C1.0 COVER SHEET 2 C2.0 TOPOGRAPHIC SURVEY 3 C3.0 DEMOLITION PLAN 4 C4.0 PRELIMINARY SITE PLAN 5 C5.0 PRELIMINARY GRADING & DRAINAGE PLAN 6 C5.1 TYPICAL SECTIONS 7 C6.0 PRELIMINARY UTILITY PLAN 8 C7.0 PRELIMINARY SWQCP 9 C8.0 FIRE ACCESS PLAN 10 C9.0 GARBAGE TRUCK TURNING 11 C10.0 TRUCK TURNING 12 C10.1 TRUCK TURNING 13 C11.0 EXISTING EASEMENTS TO REMAIN 14 C11.1 EXISTING EASEMENTS TO BE VACATED 15 C11.2 PROPOSED EASEMENTS 16 C12.0 CLEAN BAY BLUE PRINT ARCHITECTURAL LANDSCAPE SHEET INDEX CIVIL ENGINEER KIER & WRIGHT CIVIL ENGINEERS & SURVEYORS, INC. ATTN: ZICO SARYEDDEAN, P.E. 2850 COLLIER CANYON ROAD LIVERMORE, CA 94551 925-245-8788 DEVELOPER DUBLIN BOULEVARD OWNER, LP 19700 S. VERMONT AVENUE #101 TORRANCE, CA 90502 310-323-9100 LANDSCAPE ARCHITECT GREEN DESIGN LANDSCAPE ARCHITECTS, INC. ATTN: BARBARA M. HATCH, RLA ASLA 1464 POPINJAY DRIVE RENO, NV 89509 775-829-1364 ARCHITECT HPA, INC. ATTN: TERESA GOODWIN, AIA 600 GRAND AVENUE, SUITE 302 OAKLAND, CA 94610 925-413-6896 C1.0 CO V E R S H E E T 28 5 0 C o l l i e r C a n y o n R o a d Li v e r m o r e , C A 9 4 5 5 1 P h o n e : ( 9 2 5 ) 2 4 5 - 8 7 8 8 ww w . k i e r w r i g h t . c o m NO . APRIL, 2023 OF 16 SHEETS SHEET DATE SCALE DESIGNER JOB NO. A22024 NO . RE V I S I O N BY RE V I S I O N BY DU B L I N B O U L E V A R D O W N E R , L P 11 7 1 1 D U B L I N B L V D FO R OF DU B L I N , CA L I F O R N I A DRAWN BY VB AS NOTED CR 1 NO R T H N SITE DUBLIN BOULEVARD HIGH W A Y 5 8 0 DUBLIN BOULEVARD HIGH W A Y 5 8 0 S I L V E R G A T E D R I V E S I L V E R G A T E D R I V E DO N L O N W A Y DO N L O N W A Y C2.0 TO P O G R A P H I C S U R V E Y NOTES LEGEND NO R T H HA N S E N D R I V E ABBREVIATIONS 28 5 0 C o l l i e r C a n y o n R o a d Li v e r m o r e , C A 9 4 5 5 1 P h o n e : ( 9 2 5 ) 2 4 5 - 8 7 8 8 ww w . k i e r w r i g h t . c o m NO . APRIL, 2023 OF 16 SHEETS SHEET DATE SCALE DESIGNER JOB NO. A22024 NO . RE V I S I O N BY RE V I S I O N BY DU B L I N B O U L E V A R D O W N E R , L P 11 7 1 1 D U B L I N B L V D FO R OF DU B L I N , CA L I F O R N I A DRAWN BY VB AS NOTED CR 2 DUBLIN BOULEVARD HIGH W A Y 5 8 0 DUBLIN BOULEVARD HIGH W A Y 5 8 0 LEGEND C3.0 DE M O L I T I O N P L A N 28 5 0 C o l l i e r C a n y o n R o a d Li v e r m o r e , C A 9 4 5 5 1 P h o n e : ( 9 2 5 ) 2 4 5 - 8 7 8 8 ww w . k i e r w r i g h t . c o m NO . APRIL, 2023 OF 16 SHEETS SHEET DATE SCALE DESIGNER JOB NO. A22024 NO . RE V I S I O N BY RE V I S I O N BY DU B L I N B O U L E V A R D O W N E R , L P 11 7 1 1 D U B L I N B L V D FO R OF DU B L I N , CA L I F O R N I A DRAWN BY VB AS NOTED CR 3 NO R T H DUBLIN BOULEVARD HIGH W A Y 5 8 0 DUBLIN BOULEVARD HIGH W A Y 5 8 0 UNIT A UNIT B UNIT C UNIT D ON L Y VAN PARKINGNO PARKINGNO PARKINGNO VAN VAN ON L Y E V C H A R G I N G VAN ON L Y E V C H A R G I N G PARKINGNOONLY EV CHARGING E V C H A R G I N G ONLY EV CHARGING ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV CHARGING AMBULATORY ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G C4.0 PR E L I M I N A R Y S I T E P L A N 28 5 0 C o l l i e r C a n y o n R o a d Li v e r m o r e , C A 9 4 5 5 1 P h o n e : ( 9 2 5 ) 2 4 5 - 8 7 8 8 ww w . k i e r w r i g h t . c o m NO . APRIL, 2023 OF 16 SHEETS SHEET DATE SCALE DESIGNER JOB NO. A22024 NO . RE V I S I O N BY RE V I S I O N BY DU B L I N B O U L E V A R D O W N E R , L P 11 7 1 1 D U B L I N B L V D FO R OF DU B L I N , CA L I F O R N I A DRAWN BY VB AS NOTED CR 4 NO R T H DUBLIN BOULEVARD HIGH W A Y 5 8 0 DUBLIN BOULEVARD HIGH W A Y 5 8 0 UNIT A UNIT B UNIT C UNIT D ON L Y VAN PARKINGNO PARKINGNO PARKINGNO VAN VAN ON L Y E V C H A R G I N G VAN ON L Y E V C H A R G I N G PARKINGNOONLY EV CHARGING E V C H A R G I N G ONLY EV CHARGING ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV CHARGING AMBULATORY ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G C5.0 PR E L I M I N A R Y G R A D I N G & D R A I N A G E P L A N NO R T H 28 5 0 C o l l i e r C a n y o n R o a d Li v e r m o r e , C A 9 4 5 5 1 P h o n e : ( 9 2 5 ) 2 4 5 - 8 7 8 8 ww w . k i e r w r i g h t . c o m NO . APRIL, 2023 OF 16 SHEETS SHEET DATE SCALE DESIGNER JOB NO. A22024 NO . RE V I S I O N BY RE V I S I O N BY DU B L I N B O U L E V A R D O W N E R , L P 11 7 1 1 D U B L I N B L V D FO R OF DU B L I N , CA L I F O R N I A DRAWN BY VB AS NOTED CR 5 LEGEND NOTE SECTION 1 SECTION 2 DOUBLIN BOULEVARD SECTION 3 SECTION 4 SECTION 5 SECTION 7 DUBLIN BOULEVARD SECTION 6 DUBLIN BOULEVARD C5.1 TY P I C A L S E C T I O N S 28 5 0 C o l l i e r C a n y o n R o a d Li v e r m o r e , C A 9 4 5 5 1 P h o n e : ( 9 2 5 ) 2 4 5 - 8 7 8 8 ww w . k i e r w r i g h t . c o m NO . APRIL, 2023 OF 16 SHEETS SHEET DATE SCALE DESIGNER JOB NO. A22024 NO . RE V I S I O N BY RE V I S I O N BY DU B L I N B O U L E V A R D O W N E R , L P 11 7 1 1 D U B L I N B L V D FO R OF DU B L I N , CA L I F O R N I A DRAWN BY VB AS NOTED CR 6 DUBLIN BOULEVARD HIGH W A Y 5 8 0 DUBLIN BOULEVARD HIGH W A Y 5 8 0 UNIT A UNIT B UNIT C UNIT D ON L Y VAN PARKINGNO PARKINGNO PARKINGNO VAN VAN ON L Y E V C H A R G I N G VAN ON L Y E V C H A R G I N G PARKINGNOONLY EV CHARGING E V C H A R G I N G ONLY EV CHARGING ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV CHARGING AMBULATORY ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G LEGEND C6.0 PR E L I M I N A R Y U T I L I T Y P L A N NO R T H 28 5 0 C o l l i e r C a n y o n R o a d Li v e r m o r e , C A 9 4 5 5 1 P h o n e : ( 9 2 5 ) 2 4 5 - 8 7 8 8 ww w . k i e r w r i g h t . c o m NO . APRIL, 2023 OF 16 SHEETS SHEET DATE SCALE DESIGNER JOB NO. A22024 NO . RE V I S I O N BY RE V I S I O N BY DU B L I N B O U L E V A R D O W N E R , L P 11 7 1 1 D U B L I N B L V D FO R OF DU B L I N , CA L I F O R N I A DRAWN BY VB AS NOTED CR 7 DUBLIN BOULEVARD HIGH W A Y 5 8 0 DUBLIN BOULEVARD HIGH W A Y 5 8 0 ON L Y VAN PARKINGNO PARKINGNO PARKINGNO VAN VAN ON L Y E V C H A R G I N G VAN ON L Y E V C H A R G I N G PARKINGNOONLY EV CHARGING E V C H A R G I N G ONLY EV CHARGING ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV CHARGING AMBULATORY ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G LEGEND C7.0 PR E L I M I N A R Y S W Q C P NO R T H 28 5 0 C o l l i e r C a n y o n R o a d Li v e r m o r e , C A 9 4 5 5 1 P h o n e : ( 9 2 5 ) 2 4 5 - 8 7 8 8 ww w . k i e r w r i g h t . c o m NO . APRIL, 2023 OF 16 SHEETS SHEET DATE SCALE DESIGNER JOB NO. A22024 NO . RE V I S I O N BY RE V I S I O N BY DU B L I N B O U L E V A R D O W N E R , L P 11 7 1 1 D U B L I N B L V D FO R OF DU B L I N , CA L I F O R N I A DRAWN BY VB AS NOTED CR 8 DMA 1 DMA 2 DMA 3 DMA 4 DMA 5 NOTE: BIO-RETENTION DETAILS 1 NOTES DUBLIN BOULEVARD HIGH W A Y 5 8 0 DUBLIN BOULEVARD HIGH W A Y 5 8 0 UNIT A UNIT B UNIT C UNIT D ON L Y VAN PARKINGNO PARKINGNO PARKINGNO VAN VAN ON L Y E V C H A R G I N G VAN ON L Y E V C H A R G I N G PARKINGNOONLY EV CHARGING E V C H A R G I N G ONLY EV CHARGING ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV CHARGING AMBULATORY ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G C8.0 FI R E A C C E S S P L A N 28 5 0 C o l l i e r C a n y o n R o a d Li v e r m o r e , C A 9 4 5 5 1 P h o n e : ( 9 2 5 ) 2 4 5 - 8 7 8 8 ww w . k i e r w r i g h t . c o m NO . APRIL, 2023 OF 16 SHEETS SHEET DATE SCALE DESIGNER JOB NO. A22024 NO . RE V I S I O N BY RE V I S I O N BY DU B L I N B O U L E V A R D O W N E R , L P 11 7 1 1 D U B L I N B L V D FO R OF DU B L I N , CA L I F O R N I A DRAWN BY VB AS NOTED CR 9 NO R T H DUBLIN BOULEVARD HIGH W A Y 5 8 0 DUBLIN BOULEVARD HIGH W A Y 5 8 0 UNIT A UNIT B UNIT C UNIT D ON L Y VAN PARKINGNO PARKINGNO PARKINGNO VAN VAN ON L Y E V C H A R G I N G VAN ON L Y E V C H A R G I N G PARKINGNOONLY EV CHARGING E V C H A R G I N G ONLY EV CHARGING ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV CHARGING AMBULATORY ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G C9.0 GA R B A G E T R U C K T U R N I N G 28 5 0 C o l l i e r C a n y o n R o a d Li v e r m o r e , C A 9 4 5 5 1 P h o n e : ( 9 2 5 ) 2 4 5 - 8 7 8 8 ww w . k i e r w r i g h t . c o m NO . APRIL, 2023 OF 16 SHEETS SHEET DATE SCALE DESIGNER JOB NO. A22024 NO . RE V I S I O N BY RE V I S I O N BY DU B L I N B O U L E V A R D O W N E R , L P 11 7 1 1 D U B L I N B L V D FO R OF DU B L I N , CA L I F O R N I A DRAWN BY VB AS NOTED CR 10 NO R T H DUBLIN BOULEVARD HIGH W A Y 5 8 0 DUBLIN BOULEVARD HIGH W A Y 5 8 0 UNIT A UNIT B UNIT C UNIT D ON L Y VAN PARKINGNO PARKINGNO PARKINGNO VAN VAN ON L Y E V C H A R G I N G VAN ON L Y E V C H A R G I N G PARKINGNOONLY EV CHARGING E V C H A R G I N G ONLY EV CHARGING ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV CHARGING AMBULATORY ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G C10.0 TR U C K T U R N I N G 28 5 0 C o l l i e r C a n y o n R o a d Li v e r m o r e , C A 9 4 5 5 1 P h o n e : ( 9 2 5 ) 2 4 5 - 8 7 8 8 ww w . k i e r w r i g h t . c o m NO . APRIL, 2023 OF 16 SHEETS SHEET DATE SCALE DESIGNER JOB NO. A22024 NO . RE V I S I O N BY RE V I S I O N BY DU B L I N B O U L E V A R D O W N E R , L P 11 7 1 1 D U B L I N B L V D FO R OF DU B L I N , CA L I F O R N I A DRAWN BY VB AS NOTED CR 11 NO R T H DUBLIN BOULEVARD HIGH W A Y 5 8 0 DUBLIN BOULEVARD HIGH W A Y 5 8 0 UNIT A UNIT B UNIT C UNIT D ON L Y VAN PARKINGNO PARKINGNO PARKINGNO VAN VAN ON L Y E V C H A R G I N G VAN ON L Y E V C H A R G I N G PARKINGNOONLY EV CHARGING E V C H A R G I N G ONLY EV CHARGING ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV CHARGING AMBULATORY ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G C10.1 TR U C K T U R N I N G 28 5 0 C o l l i e r C a n y o n R o a d Li v e r m o r e , C A 9 4 5 5 1 P h o n e : ( 9 2 5 ) 2 4 5 - 8 7 8 8 ww w . k i e r w r i g h t . c o m NO . APRIL, 2023 OF 16 SHEETS SHEET DATE SCALE DESIGNER JOB NO. A22024 NO . RE V I S I O N BY RE V I S I O N BY DU B L I N B O U L E V A R D O W N E R , L P 11 7 1 1 D U B L I N B L V D FO R OF DU B L I N , CA L I F O R N I A DRAWN BY VB AS NOTED CR 12 NO R T H DUBLIN BOULEVARD HIGH W A Y 5 8 0 DUBLIN BOULEVARD HIGH W A Y 5 8 0 UNIT A UNIT B UNIT C UNIT D ON L Y VAN PARKINGNO PARKINGNO PARKINGNO VAN VAN ON L Y E V C H A R G I N G VAN ON L Y E V C H A R G I N G PARKINGNOONLY EV CHARGING E V C H A R G I N G ONLY EV CHARGING ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV CHARGING AMBULATORY ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G C11.0 EX I S T I N G E A S E M E N T S T O R E M A I N 28 5 0 C o l l i e r C a n y o n R o a d Li v e r m o r e , C A 9 4 5 5 1 P h o n e : ( 9 2 5 ) 2 4 5 - 8 7 8 8 ww w . k i e r w r i g h t . c o m NO . APRIL, 2023 OF 16 SHEETS SHEET DATE SCALE DESIGNER JOB NO. A22024 NO . RE V I S I O N BY RE V I S I O N BY DU B L I N B O U L E V A R D O W N E R , L P 11 7 1 1 D U B L I N B L V D FO R OF DU B L I N , CA L I F O R N I A DRAWN BY VB AS NOTED CR 13 NO R T H CITY OF DUBLIN HEXCEL CORP.TO REMAIN DUBLIN HILL INC.HEXCEL CORP.TO REMAIN GTE SPRINT/PG&E HEXCEL CORP.TO REMAIN PG&E HEXCEL CORP.TO REMAIN DUBLIN HILL INC.HEXCEL CORP.TO REMAIN DUBLIN HILL INC.HEXCEL CORP.TO REMAIN CITY OF DUBLIN HEXCEL CORP.TO REMAIN STATE OF CA MR. & MRS. KOLB TO REMAIN STATE OF CA/PG&E HEXCEL CORP.TO REMAIN STATE OF CA/PG&E HEXCEL CORP.TO REMAIN STATE OF CA HEXCEL CORP.TO REMAIN DUBLIN BOULEVARD HIGH W A Y 5 8 0 DUBLIN BOULEVARD HIGH W A Y 5 8 0 UNIT A UNIT B UNIT C UNIT D ON L Y VAN PARKINGNO PARKINGNO PARKINGNO VAN VAN ON L Y E V C H A R G I N G VAN ON L Y E V C H A R G I N G PARKINGNOONLY EV CHARGING E V C H A R G I N G ONLY EV CHARGING ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV CHARGING AMBULATORY ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G C11.1 EX I S T I N G E A S E M E N T S T O B E V A C A T E D 28 5 0 C o l l i e r C a n y o n R o a d Li v e r m o r e , C A 9 4 5 5 1 P h o n e : ( 9 2 5 ) 2 4 5 - 8 7 8 8 ww w . k i e r w r i g h t . c o m NO . APRIL, 2023 OF 16 SHEETS SHEET DATE SCALE DESIGNER JOB NO. A22024 NO . RE V I S I O N BY RE V I S I O N BY DU B L I N B O U L E V A R D O W N E R , L P 11 7 1 1 D U B L I N B L V D FO R OF DU B L I N , CA L I F O R N I A DRAWN BY VB AS NOTED CR 14 DUBLIN HILL INC.HEXCELCORP.TO BE VACATED STATE OF CA/COUNTY HEXCEL CORP.TO BE VACATED NO R T H DUBLIN BOULEVARD HIGH W A Y 5 8 0 DUBLIN BOULEVARD HIGH W A Y 5 8 0 UNIT A UNIT B UNIT C UNIT D ON L Y VAN PARKINGNO PARKINGNO PARKINGNO VAN VAN ON L Y E V C H A R G I N G VAN ON L Y E V C H A R G I N G PARKINGNOONLY EV CHARGING E V C H A R G I N G ONLY EV CHARGING ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV CHARGING AMBULATORY ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G C11.2 PR O P O S E D E A S E M E N T S 28 5 0 C o l l i e r C a n y o n R o a d Li v e r m o r e , C A 9 4 5 5 1 P h o n e : ( 9 2 5 ) 2 4 5 - 8 7 8 8 ww w . k i e r w r i g h t . c o m NO . APRIL, 2023 OF 16 SHEETS SHEET DATE SCALE DESIGNER JOB NO. A22024 NO . RE V I S I O N BY RE V I S I O N BY DU B L I N B O U L E V A R D O W N E R , L P 11 7 1 1 D U B L I N B L V D FO R OF DU B L I N , CA L I F O R N I A DRAWN BY VB AS NOTED CR 15 NUMBER COLOR CHART EASEMENT USE IN FAVOR OF GRANTED BY DISPOSITION 1 PUBLIC SERVICE EASEMENT CITY OF DUBLIN DUBLIN BOULEVARD OWNER,LP PROPOSED 2 DUBLIN SAN RAMON SEWER DISTRICT EASEMENT DUBLIN SAN RAMON SEWER DISTRICT DUBLIN BOULEVARD OWNER, LP PROPOSED 3 EMERGENCY VEHICLE ACCESS EASEMENT CITY OF DUBLIN DUBLIN BOULEVARD OWNER, LP PROPOSED 4 PUBLIC SIDEWALK EASEMENT CITY OF DUBLIN DUBLIN BOULEVARD OWNER, LP PROPOSED 5 STORM DRAIN ACCESS EASEMENT CITY OF DUBLIN DUBLIN BOULEVARD OWNER, LP PROPOSED 6 SEWER EASEMENT (EITHER PRIVATE OR DSRSD) ENTERPRISE LLC OR DUBLIN SAN RAMON SEWER DISTRICT DUBLIN BOULEVARD OWNER,LP PROPOSED 7 AT&T EASEMENT AT&T DUBLIN BOULEVARD OWNER, LP PROPOSED 8 PUBLIC UTILITY EASEMENT CITY OF DUBLIN DUBLIN BOULEVARD OWNER, LP PROPOSED NO R T H PUBLIC SERVICE EASEMENT DETAIL C12.0 CL E A N B A Y B L U E P R I N T 28 5 0 C o l l i e r C a n y o n R o a d Li v e r m o r e , C A 9 4 5 5 1 P h o n e : ( 9 2 5 ) 2 4 5 - 8 7 8 8 ww w . k i e r w r i g h t . c o m NO . APRIL, 2023 OF 16 SHEETS SHEET DATE SCALE DESIGNER JOB NO. A22024 NO . RE V I S I O N BY RE V I S I O N BY DU B L I N B O U L E V A R D O W N E R , L P 11 7 1 1 D U B L I N B L V D FO R OF DU B L I N , CA L I F O R N I A DRAWN BY VB AS NOTED CR 16 UNIT A UNIT B ON L Y VAN PARKINGNO PARKINGNO ON L Y E V C H A R G I N G VAN ON L Y E V C H A R G I N G ONLY EV CHARGING E V C H A R G I N G ONLY EV CHARGING ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV CHARGING AMBULATORY ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G PRELIMINARY LANDSCAPE PLAN SCALE: 1" = 30' LANDSCAPE CALCULATIONS: L1.1 LANDSCAPE PLAN HYDROZONE GRASSES DROUGHT TOLERANT SHRUBS PERENNIALS SYM. NO. BOTANICAL NAME COMMON NAME SIZE WATER REGIME MATURE HABITH X W EVERGREEN SCREENING SHRUBS PLANT LIST WATER EFFICIENT LANDSCAPE REQUIREMENTS BIO-RETENTION PLANTING MULCHES MA T C H L I N E S E E S H E E T L 1 . 2 Project: Consultants: Project Number: Revision: Date: Drawn by: Title: Sheet: C I V I L STRUCTURAL MECHANICAL PLUMBING ELECTRICAL LANDSCAPE SOILS ENGINEER FIRE PROTECTION RJA - - - - Green Design - - Developer tel: 949 862 2113 email: hpa@hparchs.com 94610 oakland, ca 600 grand ave, suite 302 hpa, inc. BH 1464 Popinjay Drive Reno, NV. email: bhatch00@charter.net p: 775 829 1364 11711 DUBLIN BLVD. DUBLIN, CA 21657 08/18/2022 19700 Vermont Ave. Suite 101 Torance, CA 90502 DUBLIN BOULEVARD OWNER, LP 1-26-23 COMMENTS 4-12-23 COMMENTS 11-3-23 COMMENTS PRELIMINARY CA. NATIVE DUBLIN BLVD. “ ” WATER EFFICIENT LANDSCAPE REQUIREMENTS NOTE: UNIT C UNIT D PARKINGNO VAN VAN PARKINGNO L1.2 LANDSCAPE PLAN PRELIMINARY LANDSCAPE PLAN SCALE: 1" = 30' MA T C H L I N E S E E S H E E T L 1 . 1 Project: Consultants: Project Number: Revision: Date: Drawn by: Title: Sheet: C I V I L STRUCTURAL MECHANICAL PLUMBING ELECTRICAL LANDSCAPE SOILS ENGINEER FIRE PROTECTION RJA - - - - Green Design - - Developer tel: 949 862 2113 email: hpa@hparchs.com 94610 oakland, ca 600 grand ave, suite 302 hpa, inc. BH 1464 Popinjay Drive Reno, NV. email: bhatch00@charter.net p: 775 829 1364 11711 DUBLIN BLVD. DUBLIN, CA 21657 08/18/2022 19700 Vermont Ave. Suite 101 Torance, CA 90502 DUBLIN BOULEVARD OWNER, LP 1-26-23 COMMENTS 4-12-23 COMMENTS 11-3-23 COMMENTS PRELIMINARY DUBLIN BLVD. L1.3 LANDSCAPE PLAN Project: Consultants: Project Number: Revision: Date: Drawn by: Title: Sheet: C I V I L STRUCTURAL MECHANICAL PLUMBING ELECTRICAL LANDSCAPE SOILS ENGINEER FIRE PROTECTION RJA - - - - Green Design - - Developer tel: 949 862 2113 email: hpa@hparchs.com 94610 oakland, ca 600 grand ave, suite 302 hpa, inc. BH 1464 Popinjay Drive Reno, NV. email: bhatch00@charter.net p: 775 829 1364 11711 DUBLIN BLVD. DUBLIN, CA 21657 08/18/2022 19700 Vermont Ave. Suite 101 Torance, CA 90502 DUBLIN BOULEVARD OWNER, LP 1-26-23 COMMENTS 4-12-23 COMMENTS 11-3-23 COMMENTS PRELIMINARY TREE DATA CONTINUED ON SHEET L1.4 EXISTING TREES ONSITE EXISTING TREES IN FENCED CREEK AREA (NOT TO BE DISTURBED) UNIT A UNIT B UNIT C UNIT D ON L Y VAN PARKINGNO PARKINGNO PARKINGNO VAN VAN ON L Y E V C H A R G I N G VAN ON L Y E V C H A R G I N G PARKINGNOONLY EV CHARGING E V C H A R G I N G ONLY EV CHARGING ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV CHARGING AMBULATORY ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G L1.4 LANDSCAPE PLAN Project: Consultants: Project Number: Revision: Date: Drawn by: Title: Sheet: C I V I L STRUCTURAL MECHANICAL PLUMBING ELECTRICAL LANDSCAPE SOILS ENGINEER FIRE PROTECTION RJA - - - - Green Design - - Developer tel: 949 862 2113 email: hpa@hparchs.com 94610 oakland, ca 600 grand ave, suite 302 hpa, inc. BH 1464 Popinjay Drive Reno, NV. email: bhatch00@charter.net p: 775 829 1364 11711 DUBLIN BLVD. DUBLIN, CA 21657 08/18/2022 19700 Vermont Ave. Suite 101 Torance, CA 90502 DUBLIN BOULEVARD OWNER, LP 1-26-23 COMMENTS 4-12-23 COMMENTS 11-3-23 COMMENTS PRELIMINARY PRELIMINARY TREE PRESERVATION PLAN SCALE: 1" = 40' PARCEL 2 UNIT A UNIT B ON L Y VAN PARKINGNO PARKINGNO ON L Y E V C H A R G I N G VAN ON L Y E V C H A R G I N G ONLY EV CHARGING E V C H A R G I N G ONLY EV CHARGING ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV CHARGING AMBULATORY ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G PRELIMINARY IRRIGATION PLAN SCALE: 1" = 30'L2.1 WATER EFFICIENT LANDSCAPE REQUIREMENTS IRRIGATION LEGEND: LATERAL PIPE SIZING: CONNECTION DETAIL AUTOMATIC CONTROL VALVEMA T C H L I N E S E E S H E E T L 2 . 2 IRRIGTATION PLAN PRELIMINARY Project: Consultants: Project Number: Revision: Date: Drawn by: Title: Sheet: C I V I L STRUCTURAL MECHANICAL PLUMBING ELECTRICAL LANDSCAPE SOILS ENGINEER FIRE PROTECTION RJA - - - - Green Design - - Developer tel: 949 862 2113 email: hpa@hparchs.com 94610 oakland, ca 600 grand ave, suite 302 hpa, inc. BH 1464 Popinjay Drive Reno, NV. email: bhatch00@charter.net p: 775 829 1364 11711 DUBLIN BLVD. DUBLIN, CA 21657 08/18/2022 19700 Vermont Ave. Suite 101 Torance, CA 90502 DUBLIN BOULEVARD OWNER, LP 1-26-23 COMMENTS 4-12-23 COMMENTS DUBLIN BLVD. “ ” NOTE: UNIT C UNIT D PARKINGNO VAN VAN PARKINGNO L2.2 IRRIGTATION PLAN PRELIMINARY IRRIGATION PLAN SCALE: 1" = 30' MA T C H L I N E S E E S H E E T L 2 . 2 PRELIMINARY Project: Consultants: Project Number: Revision: Date: Drawn by: Title: Sheet: C I V I L STRUCTURAL MECHANICAL PLUMBING ELECTRICAL LANDSCAPE SOILS ENGINEER FIRE PROTECTION RJA - - - - Green Design - - Developer tel: 949 862 2113 email: hpa@hparchs.com 94610 oakland, ca 600 grand ave, suite 302 hpa, inc. BH 1464 Popinjay Drive Reno, NV. email: bhatch00@charter.net p: 775 829 1364 11711 DUBLIN BLVD. DUBLIN, CA 21657 08/18/2022 19700 Vermont Ave. Suite 101 Torance, CA 90502 DUBLIN BOULEVARD OWNER, LP 1-26-23 COMMENTS 4-12-23 COMMENTS DUBLIN BLVD. L2.3 IRRIGTATION PLAN PRELIMINARY IRRIGATION PLAN SCALE: 1" = 30' PRELIMINARY Project: Consultants: Project Number: Revision: Date: Drawn by: Title: Sheet: C I V I L STRUCTURAL MECHANICAL PLUMBING ELECTRICAL LANDSCAPE SOILS ENGINEER FIRE PROTECTION RJA - - - - Green Design - - Developer tel: 949 862 2113 email: hpa@hparchs.com 94610 oakland, ca 600 grand ave, suite 302 hpa, inc. BH 1464 Popinjay Drive Reno, NV. email: bhatch00@charter.net p: 775 829 1364 11711 DUBLIN BLVD. DUBLIN, CA 21657 08/18/2022 19700 Vermont Ave. Suite 101 Torance, CA 90502 DUBLIN BOULEVARD OWNER, LP 1-26-23 COMMENTS 4-12-23 COMMENTS ON L Y VAN PARKINGNO PARKINGNO PARKINGNO VAN VAN ON L Y E V C H A R G I N G VAN ON L Y E V C H A R G I N G PARKINGNOONLY EV CHARGING E V C H A R G I N G ONLY EV CHARGING ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV C H A R G I N G ONLY EV CHARGING AMBULATORY ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G ON L Y E V C H A R G I N G 1.1 1.2 1.3 1.4 1.5 1.6 2.0 2.4 2.1 1.9 2.5 2.0 1.6 1.5 1.0 1.5 1.6 1.7 1.7 1.9 2.0 2.3 2.7 2.8 2.9 2.8 2.4 2.0 1.8 1.6 1.4 1.3 1.6 1.9 2.0 2.0 1.9 1.9 2.0 2.1 2.2 2.5 2.5 2.5 2.5 2.3 2.1 2.0 1.9 1.8 1.8 1.7 1.8 2.4 2.5 2.5 2.4 2.3 2.2 2.2 2.2 2.3 2.3 2.4 2.4 2.3 2.3 2.3 2.2 2.3 2.4 2.5 2.4 2.1 2.7 3.0 3.1 3.0 2.8 2.6 2.4 2.5 2.5 2.4 2.4 2.3 2.3 2.4 2.4 2.6 2.7 2.8 3.1 3.3 3.3 2.9 2.5 3.5 3.8 3.7 3.6 3.3 3.0 2.7 2.8 2.9 2.8 2.5 2.3 2.4 2.6 2.8 3.0 3.2 3.4 3.8 4.2 4.2 3.7 2.9 3.0 4.1 4.2 4.2 4.1 3.7 3.4 3.1 3.3 3.5 3.4 3.0 2.8 2.8 3.1 3.4 3.4 3.5 4.1 4.5 4.9 5.0 4.3 3.4 2.4 2.0 3.7 4.1 4.5 4.6 4.5 4.2 3.9 3.6 3.8 4.5 4.8 4.1 3.6 3.6 4.3 4.8 4.2 3.7 4.2 5.0 5.2 5.3 4.6 3.6 2.7 1.9 3.0 3.7 4.1 4.5 4.8 5.2 4.9 5.4 5.4 4.6 3.7 2.9 2.3 1.7 1.8 2.9 3.5 3.8 4.3 4.7 4.6 3.2 3.9 4.5 3.9 3.3 2.7 2.2 1.7 2.1 2.6 3.1 3.3 3.7 3.7 4.3 4.6 5.1 4.1 3.6 3.3 2.8 2.2 1.3 2.1 2.5 2.7 3.0 3.3 3.7 4.9 6.9 5.5 4.5 3.9 3.4 2.7 2.0 1.6 2.1 2.4 2.6 2.8 3.1 3.6 5.2 6.5 5.2 4.9 4.4 3.9 3.2 2.5 1.9 1.1 2.0 2.3 2.4 2.5 2.8 3.0 3.5 5.0 5.4 4.4 4.3 4.0 3.4 2.8 2.2 1.7 1.7 2.3 2.4 2.4 2.6 2.9 3.2 3.8 5.4 6.1 3.7 3.6 3.3 2.9 2.6 2.2 1.7 1.1 2.4 2.5 2.4 2.4 2.6 3.0 3.5 4.3 5.7 7.4 3.4 3.2 3.0 2.9 2.8 2.4 1.7 2.1 2.8 2.6 2.4 2.4 2.6 3.1 3.7 4.3 5.3 5.7 3.3 3.2 3.3 3.3 3.0 2.5 2.2 2.7 2.5 2.2 2.3 2.5 3.1 3.7 4.2 4.8 4.4 3.1 3.1 3.4 3.4 3.2 3.1 2.7 2.2 2.7 2.4 2.2 2.0 2.1 2.4 2.9 3.5 4.0 4.3 3.7 2.8 3.1 3.1 3.1 3.1 3.3 2.6 2.2 2.4 2.2 2.0 1.8 1.9 2.2 2.6 3.1 3.5 3.5 3.2 2.6 2.7 2.7 2.9 3.0 3.1 1.7 1.9 2.0 1.9 1.8 1.7 1.7 2.0 2.3 2.7 3.0 3.2 3.1 3.1 2.3 2.3 2.4 2.6 2.9 2.8 1.6 1.7 1.7 1.6 1.6 1.6 1.9 2.2 2.6 2.9 3.1 3.2 3.3 1.9 2.0 2.1 2.2 2.7 2.5 1.5 1.6 1.5 1.5 1.5 1.6 1.9 2.3 2.8 3.1 3.4 1.6 1.5 1.9 1.9 1.9 2.3 2.0 1.4 1.5 1.5 1.4 1.5 1.6 2.0 2.6 3.2 3.8 4.1 1.8 2.1 1.7 1.7 1.7 2.0 1.8 1.4 1.6 1.5 1.4 1.4 1.7 2.1 2.8 3.6 4.3 4.9 2.0 2.2 1.7 1.6 1.6 1.9 1.6 1.7 1.7 1.5 1.4 1.5 1.7 2.2 2.9 3.7 4.5 5.6 2.8 2.4 1.8 1.6 1.4 1.9 1.5 1.8 1.8 1.6 1.4 1.5 1.7 2.1 2.8 3.6 4.4 5.8 3.3 2.9 2.0 1.7 1.5 2.0 1.5 2.1 2.1 1.8 1.5 1.5 1.6 2.0 2.6 3.2 3.9 4.9 4.2 3.4 2.3 2.0 1.6 2.1 1.5 2.5 2.4 2.0 1.6 1.5 1.6 1.9 2.3 2.8 3.3 4.1 5.2 4.2 2.7 2.3 1.8 2.3 1.6 2.0 2.5 2.0 1.7 1.5 1.6 1.8 2.2 2.6 3.0 3.6 5.0 4.4 2.8 2.4 1.9 2.4 1.6 2.3 2.4 2.0 1.7 1.5 1.6 1.9 2.3 2.8 3.2 3.4 4.3 3.5 2.6 2.3 1.9 2.3 1.6 2.3 2.3 1.9 1.6 1.5 1.6 2.0 2.6 3.2 3.7 3.6 3.5 3.0 2.3 2.1 1.9 2.3 1.6 1.9 1.9 1.7 1.5 1.5 1.7 2.1 2.8 3.6 4.1 4.1 2.8 2.6 2.1 2.0 1.9 2.4 1.7 1.5 1.6 1.5 1.4 1.4 1.7 2.2 2.8 3.7 4.3 4.7 2.2 2.3 2.0 2.0 2.2 2.5 2.0 1.3 1.5 1.4 1.3 1.4 1.6 2.1 2.7 3.5 4.2 4.9 2.0 2.3 2.0 2.1 2.2 2.6 2.1 1.2 1.3 1.3 1.3 1.3 1.5 1.9 2.5 3.2 3.9 5.0 1.7 2.1 2.0 2.2 2.4 3.0 2.4 1.1 1.3 1.3 1.2 1.3 1.4 1.8 2.2 2.8 3.5 5.2 2.8 1.5 1.8 2.1 2.5 3.2 2.8 1.1 1.2 1.2 1.2 1.3 1.4 1.7 2.1 2.6 3.4 4.9 4.0 1.3 1.6 2.0 2.6 3.2 2.0 1.1 1.2 1.2 1.2 1.2 1.4 1.8 2.2 2.8 3.6 5.0 1.0 1.2 1.5 1.9 2.4 3.1 2.7 1.0 1.2 1.1 1.1 1.1 1.2 1.4 1.9 2.5 3.2 4.1 5.4 5.7 1.3 1.6 1.9 2.4 2.9 2.5 1.0 1.2 1.3 1.1 1.1 1.1 1.2 1.5 2.0 2.7 3.5 4.4 5.9 1.9 1.5 1.7 2.0 2.1 2.6 2.1 1.0 1.5 1.4 1.2 1.1 1.1 1.2 1.5 2.0 2.8 3.6 4.4 5.6 1.9 2.1 2.0 2.0 2.0 2.4 2.0 1.4 1.9 1.6 1.3 1.1 1.1 1.2 1.5 2.0 2.7 3.5 4.2 4.8 2.1 2.4 2.0 2.1 2.0 2.3 1.8 1.9 2.3 2.0 1.5 1.2 1.1 1.1 1.4 1.9 2.5 3.1 3.7 4.0 2.4 2.4 2.1 2.0 2.0 2.2 1.7 1.3 2.5 2.0 1.5 1.2 1.1 1.1 1.3 1.7 2.2 2.7 3.1 3.4 2.8 2.6 2.2 2.0 2.1 2.3 1.8 1.4 2.5 2.0 1.5 1.2 1.1 1.1 1.3 1.7 2.1 2.6 2.9 3.1 3.4 3.2 2.4 2.3 2.1 2.4 1.9 2.0 2.4 2.0 1.5 1.2 1.1 1.1 1.4 1.8 2.2 2.7 3.1 3.3 3.9 3.8 2.8 2.6 2.2 2.6 2.0 1.5 2.0 1.7 1.4 1.2 1.1 1.2 1.4 1.9 2.5 3.2 3.7 3.8 5.5 4.4 3.2 2.7 2.3 2.8 2.2 1.3 1.7 1.5 1.3 1.2 1.1 1.2 1.5 2.1 2.8 3.5 4.2 4.6 6.8 5.1 3.3 2.8 2.4 2.9 2.3 1.4 1.6 1.5 1.3 1.2 1.2 1.3 1.6 2.1 2.9 3.7 4.4 5.2 5.4 4.4 3.1 2.8 2.5 3.0 2.5 1.3 1.5 1.5 1.3 1.2 1.2 1.3 1.6 2.1 2.8 3.6 4.4 5.6 4.3 3.8 2.8 2.6 2.5 3.2 2.9 1.3 1.5 1.5 1.4 1.3 1.3 1.4 1.6 2.1 2.7 3.3 4.1 5.3 3.6 3.3 2.5 2.5 2.6 3.3 3.3 1.5 1.6 1.6 1.5 1.4 1.4 1.5 1.6 2.0 2.4 2.9 3.4 4.5 3.0 2.9 2.4 2.5 2.7 3.4 3.6 4.1 3.7 2.9 2.2 1.7 1.3 1.1 1.7 1.7 1.7 1.6 1.5 1.5 1.7 2.0 2.4 2.8 3.2 4.0 2.5 2.8 2.5 2.6 2.7 3.4 3.7 4.2 3.8 2.9 2.3 1.8 1.4 1.1 1.5 1.6 1.7 1.7 1.8 1.9 1.9 1.8 1.8 1.6 1.6 1.6 1.8 2.1 2.5 3.0 3.3 3.7 2.4 2.7 2.5 2.5 2.6 3.3 3.4 3.5 3.2 2.8 2.3 1.8 1.5 1.2 1.7 1.9 2.0 2.1 2.1 2.1 2.1 2.0 1.8 1.7 1.6 1.7 1.9 2.3 2.8 3.4 3.8 3.8 2.1 2.1 2.3 2.4 2.5 3.0 2.9 2.9 2.7 2.5 2.2 1.8 1.5 1.3 1.5 1.8 2.1 2.3 2.5 2.6 2.6 2.5 2.4 2.2 2.0 1.8 1.7 1.8 2.0 2.4 3.0 3.8 4.3 4.3 1.6 1.8 2.0 2.2 2.3 2.6 2.6 2.6 2.5 2.3 2.0 1.8 1.6 1.3 1.1 1.3 1.7 2.1 2.5 2.9 3.2 3.3 3.3 3.1 2.8 2.5 2.1 1.9 1.7 1.8 2.0 2.5 3.1 3.9 4.5 4.9 1.3 1.5 1.8 1.9 2.1 2.4 2.4 2.4 2.3 2.2 2.0 1.8 1.6 1.4 1.1 1.4 1.8 2.3 2.9 3.6 4.1 4.3 4.2 3.9 3.4 2.8 2.3 1.9 1.8 1.8 2.0 2.4 3.0 3.7 4.4 5.1 1.7 1.3 1.5 1.7 1.9 2.2 2.3 2.4 2.3 2.2 2.0 1.8 1.6 1.4 1.1 1.5 1.9 2.5 3.2 4.2 5.0 5.1 5.2 4.8 3.8 3.0 2.4 2.0 1.8 1.7 1.9 2.2 2.8 3.3 4.0 5.2 5.6 1.1 1.4 1.6 1.9 2.2 2.4 2.5 2.5 2.4 2.2 1.9 1.6 1.3 1.1 1.5 1.9 2.5 3.3 4.3 5.4 5.3 5.3 5.1 3.9 3.0 2.4 1.9 1.7 1.7 1.8 2.1 2.4 2.9 3.5 5.0 0.8 1.0 1.2 1.5 1.8 2.2 2.6 2.9 3.0 2.8 2.4 2.0 1.6 1.3 1.1 1.4 1.9 2.4 3.1 3.8 4.5 4.6 4.6 4.3 3.6 2.9 2.3 1.9 1.7 1.6 1.7 1.9 2.2 2.6 3.1 4.2 0.7 1.0 1.2 1.5 1.8 2.2 2.7 3.3 3.6 3.2 2.6 2.0 1.6 1.3 1.1 1.4 1.7 2.2 2.7 3.1 3.5 3.7 3.6 3.4 3.0 2.5 2.1 1.8 1.6 1.6 1.7 1.9 2.2 2.7 3.1 3.9 1.0 1.1 1.2 1.4 1.7 2.1 2.7 3.3 4.0 3.2 2.5 2.0 1.5 1.2 1.0 1.3 1.6 1.9 2.2 2.5 2.8 2.9 2.9 2.7 2.5 2.2 1.9 1.7 1.5 1.5 1.6 1.9 2.3 2.9 3.4 3.6 3.5 3.2 1.7 2.6 4.3 5.8 4.8 3.4 2.4 1.7 1.3 1.3 1.7 2.4 4.0 5.3 3.9 3.3 2.8 2.5 2.1 1.7 1.4 1.2 1.2 1.2 1.3 1.5 1.7 2.1 2.5 2.9 3.1 2.8 2.3 1.8 1.4 1.1 1.2 1.4 1.6 1.9 2.1 2.2 2.3 2.3 2.2 2.0 1.8 1.7 1.5 1.4 1.4 1.6 1.8 2.2 2.7 3.1 3.2 3.1 2.8 2.2 2.3 3.0 3.4 3.2 2.9 2.3 1.8 1.5 1.6 1.9 2.3 2.8 3.2 3.0 2.9 2.5 2.2 2.0 1.6 1.5 1.3 1.3 1.3 1.3 1.4 1.6 1.8 2.1 2.2 2.3 2.1 1.9 1.6 1.3 1.0 1.2 1.4 1.6 1.7 1.8 1.9 1.8 1.8 1.7 1.6 1.5 1.4 1.3 1.3 1.4 1.7 2.0 2.4 2.7 2.7 2.6 2.3 2.0 1.5 1.8 2.0 2.0 1.9 1.8 1.6 1.5 1.5 1.5 1.6 1.8 1.9 2.0 2.0 1.9 1.8 1.7 1.5 1.4 1.3 1.2 1.2 1.3 3.3 3.9 4.7 6.7 7.6 5.0 4.0 3.5 3.2 3.3 3.7 4.1 4.7 6.6 7.4 5.3 4.9 6.1 7.7 5.6 4.2 3.5 3.2 3.2 3.2 3.6 4.2 5.1 7.5 6.7 4.5 3.9 3.4 3.5 3.8 4.3 5.0 7.3 6.6 4.4 3.8 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.2 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.3 0.3 0.2 0.2 0.2 0.2 0.1 0.2 0.2 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.4 0.5 0.6 0.6 0.5 0.5 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.1 0.0 0.1 0.1 0.1 0.1 0.2 0.3 0.7 0.6 0.4 0.3 0.2 0.2 0.0 0.0 0.1 0.1 0.1 0.2 0.3 1.0 0.7 0.5 0.4 0.3 0.2 0.0 0.1 0.1 0.1 0.2 0.3 1.1 0.8 0.6 0.4 0.3 0.2 0.0 0.0 0.1 0.1 0.2 0.3 0.4 1.2 0.8 0.5 0.3 0.2 0.1 0.0 0.1 0.1 0.1 0.2 0.3 1.1 0.7 0.5 0.3 0.2 0.0 0.1 0.1 0.1 0.2 0.5 0.9 0.6 0.4 0.2 0.2 0.0 0.0 0.1 0.1 0.2 0.3 0.6 0.7 0.5 0.3 0.2 0.1 0.0 0.0 0.1 0.1 0.2 0.4 0.7 0.4 0.3 0.2 0.1 0.0 0.0 0.1 0.1 0.2 0.4 0.9 0.6 0.4 0.3 0.2 0.1 0.0 0.0 0.0 0.1 0.1 0.2 0.8 0.6 0.4 0.2 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.2 0.7 0.5 0.3 0.2 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.7 0.4 0.3 0.2 0.1 0.1 0.0 0.0 0.1 0.1 0.2 0.6 0.4 0.2 0.2 0.1 0.1 0.0 0.0 0.1 0.1 0.3 0.5 0.3 0.2 0.1 0.1 0.0 0.0 0.0 0.1 0.1 0.6 0.4 0.3 0.2 0.1 0.1 0.0 0.0 0.1 0.1 0.3 0.6 0.4 0.2 0.1 0.1 0.1 0.0 0.0 0.1 0.2 0.5 0.3 0.2 0.1 0.1 0.0 0.0 0.0 0.1 0.3 0.4 0.2 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.3 0.5 0.3 0.2 0.1 0.1 0.0 0.0 0.0 0.1 0.1 0.5 0.3 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.1 0.2 1.7 0.4 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.5 2.2 1.1 0.3 0.1 0.1 0.0 0.0 0.0 0.0 0.1 0.2 0.7 1.9 1.5 0.7 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.3 0.6 1.6 1.4 0.9 0.4 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.4 0.6 1.4 1.2 0.9 0.6 0.3 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.4 0.5 1.3 1.0 0.8 0.6 0.4 0.2 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.3 0.5 1.2 0.9 0.8 0.6 0.4 0.2 0.1 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.4 1.2 0.9 0.7 0.5 0.4 0.2 0.1 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.3 1.1 0.8 0.6 0.4 0.3 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.4 1.1 0.7 0.5 0.3 0.2 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.3 1.0 0.6 0.4 0.3 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.5 0.3 0.2 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.5 0.3 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.4 0.3 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.4 0.2 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.4 0.2 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 0.4 0.2 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.4 0.5 0.2 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.5 0.5 0.2 0.2 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.4 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.4 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.5 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.1 0.1 0.2 0.5 0.4 0.3 0.3 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.7 0.5 0.4 0.4 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.3 0.8 0.6 0.5 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.3 0.9 0.7 0.6 0.6 0.5 0.4 0.4 0.3 0.3 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.3 1.1 0.9 0.8 0.7 0.6 0.5 0.5 0.4 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.3 1.3 1.1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.3 0.2 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.4 1.5 1.3 1.1 1.0 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.2 0.1 0.2 0.2 0.3 0.3 0.4 0.4 0.4 0.4 0.5 0.5 1.8 1.6 1.3 1.1 1.0 0.8 0.7 0.5 0.4 0.3 0.2 0.2 0.1 0.3 0.3 0.4 0.4 0.5 0.5 0.6 0.6 0.6 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.3 0.4 0.5 0.5 0.6 0.7 0.7 0.8 0.8 0.8 0.9 0.4 0.5 0.6 0.7 0.8 0.8 0.9 1.0 1.0 1.1 1.1 0.4 0.6 0.7 0.8 0.9 1.1 1.4 0.5 0.6 0.8 1.0 1.1 1.3 0.5 0.7 0.9 1.1 0.6 0.8 1.0 0.5 0.6 0.5 0.6 0.5 0.6 0.5 0.6 0.5 0.6 0.5 0.6 0.4 0.6 0.3 0.4 0.6 0.3 0.4 0.5 0.3 0.4 0.5 0.2 0.3 0.4 0.5 0.7 0.8 0.9 1.0 1.1 1.2 1.2 1.3 1.3 1.3 1.2 1.1 1.1 1.0 1.0 1.0 1.1 1.2 1.4 1.5 1.5 1.5 1.4 1.3 1.1 1.0 1.0 1.1 1.1 1.2 1.2 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.2 1.2 1.2 1.2 1.1 1.0 1.0 1.0 1.0 1.0 1.1 1.1 1.1 1.2 1.2 1.2 1.2 1.1 1.0 0.9 0.8 0.7 0.6 0.2 0.3 0.4 0.4 0.5 0.6 0.7 0.8 0.9 0.9 1.0 1.0 1.0 1.0 0.9 0.9 0.9 0.8 0.8 0.8 0.8 0.9 1.0 1.0 1.0 1.0 0.9 0.9 0.8 0.7 0.7 0.8 0.8 0.8 0.9 0.9 0.9 0.9 0.8 0.9 0.9 0.9 0.9 0.9 0.9 0.8 0.8 0.8 0.8 0.8 0.8 0.9 0.9 0.9 1.0 1.0 1.0 1.0 1.0 0.9 0.9 0.8 0.7 0.6 0.6 0.5 0.4 0.2 0.2 0.3 0.4 0.4 0.5 0.6 0.6 0.7 0.7 0.7 0.8 0.8 0.7 0.7 0.7 0.7 0.6 0.6 0.6 0.6 0.6 0.7 0.7 0.6 0.6 0.6 0.6 0.5 0.5 0.5 0.5 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.8 0.8 0.8 0.8 0.8 0.7 0.7 0.6 0.6 0.5 0.5 0.4 0.3 0.3 0.1 0.2 0.2 0.3 0.3 0.4 0.4 0.5 0.5 0.5 0.6 0.6 0.6 0.6 0.6 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.8 0.6 0.5 0.4 0.3 0.2 0.7 0.5 0.4 0.3 0.2 0.7 0.6 0.4 0.3 0.2 0.8 0.6 0.5 0.3 0.2 0.8 0.6 0.5 0.3 0.2 0.8 0.6 0.5 0.3 0.2 0.8 0.6 0.5 0.3 0.2 0.8 0.6 0.5 0.3 0.2 0.8 0.6 0.4 0.3 0.2 0.7 0.6 0.4 0.3 0.2 0.7 0.5 0.4 0.3 0.2 0.6 0.5 0.4 0.3 0.2 0.6 0.5 0.4 0.3 0.2 SA1 @ 27.5' W1 @ 30'W1 @ 30' W1 @ 30' W1 @ 30' W1 @ 30' W1 @ 30' W1 @ 30'W1 @ 30'W1 @ 30'W1 @ 30'W3 @ 9'W3 @ 9' W3 @ 9' W3 @ 9' W3 @ 9' W3 @ 9'W3 @ 9'W3 @ 9'W3 @ 9'W3 @ 9' W3 @ 9' SA2 @ 27.5' SA2 @ 27.5' SA2 @ 27.5' SA2 @ 27.5' W1 @ 30'W1 @ 30'W1 @ 30'W1 @ 30'W1 @ 30' SA1 @ 27.5' W3 @ 9'W3 @ 9' W3 @ 9' SA2 @ 27.5' W4 @ 9'W4 @ 9'W4 @ 9'W4 @ 9' SA2 @ 27.5' SA2 @ 27.5'SA1 @ 27.5' SA1 @ 27.5' E-1.0 SITE PHOTOMETRIC PLAN fax: 949 863 0851 tel: 949 863 1770 email: hpa@hparchs.com 92612 hpa, inc. Owner: Project: Consultants: Project Number: Revision: Date: Drawn by: Title: Sheet: Civil: Structural: Mechanical: Plumbing: Electrical: Landscape: Soils Engineer: Fire Protection: DUBLIN CA 20499 RPM 04/10/23 18831 bardeen avenue - ste. #100 irvine, ca TEL : 714-998-3400 2518 N. SANTIAGO BLVD. ORANGE, CA 92867 OMP DUBLIN CA U T I O N : I F T H I S S H E E T I S N O T A 3 0 " X 4 2 " I T I S A R E D U C E D P R I N T LDDC DFA RPM ENGINEERS RPM ENGINEERS RPM ENGINEERS - - SST & E 11711 DUBLIN BLVD SITE PHOTOMETRIC PLAN A Statistics Description Symbol Avg Max Min Max/Min Avg/Min Calc Zone #1 2.5 fc 7.4 fc 0.7 fc 10.6:1 3.6:1 Calc Zone #2 4.8 fc 7.7 fc 3.2 fc 2.4:1 1.5:1 Calc Zone #4 0.3 fc 2.2 fc 0.0 fc N/A N/A Calc Zone #5 0.5 fc 0.8 fc 0.2 fc 4.0:1 2.5:1 Schedule Symbol Label QTY Catalog Number Description Lamp Number Lamps Lumens per Lamp LLF Wattage W4 4 LC6SLEM 6LCSL 14 L EM 6 INCH LBR DOWNLIGHT 1400LM 4000K 1 1641 0.9 18 W3 14 RZR-WM1-PLED-III-W- 20LED-350mA-40K EM1 WALL MT AT 9 FT AFG MM511 BUG RATING B1 U0 G1 CAST BLACK PAINTED FINNED METAL HOUSING. 20 WHITE LIGHT EMITTING DIODES (LEDS), BASE UP. 20 151 0.9 21.4 SA2 7 VLL-PLED-III-W-80LED- 525mA-NW-HS -MM511 POLE MT AT 27.5 FT AFG 25 FT POLE 30 IN BASE BUG RATING B1 U0 G3 CAST BLACK PAINTED FINNED METAL HOUSING. 80 WHITE LIGHT EMITTING DIODES (LEDS), BASE UP. 80 167 0.9 129.4 W2 2 VLL-PLED-III-W-80LED-- MM511 525mA-NW WALL MT AT 30 FT AFG BUG B3 U0 G3 CAST BLACK PAINTED FINNED METAL HOUSING. 80 WHITE LIGHT EMITTING DIODES (LEDS), BASE UP. 80 218 0.9 129.4 W1 15 VLL-PLED-IV-80LED- 700mA-NW-MM511 BUG B3 U0 G3 WALL MT AT 30 FT AFG CAST BLACK PAINTED FINNED METAL HOUSING. 80 WHITE LIGHT EMITTING DIODES (LEDS), BASE UP. 80 295 0.9 173.6 SA1 4 VLL-PLED-VSQ-W-80LED- -525mA-40K POLE MT AT 27.5 FT AFG 25 FT POLE 30 IN BASE BUG RATING B5 U0 G3 CAST BLACK PAINTED FINNED METAL HOUSING. 80 WHITE LIGHT EMITTING DIODES (LEDS), BASE UP. 80 232 0.9 258.8