Loading...
HomeMy WebLinkAbout06-005 Pool, Patio and More SDR AGENDA STATEMENT PLANNING COMMISSION MEETING DATE: FEBRUARY 28, 2006 SUBJECT: Public Hearing - PA 06-005 Site Development Review for POQI, Patio and More, Located at 6175 Dublin Boulevard ~ Report Prepared by, Linda Ajello, Associate Planner ~ l.fi ATTACHMENTS: 1. Resolution approving a Site Development Review for PA 06-005 Pool, Patio and More 2. Applicant's Written Statement 3. Project Plans 4. Photo Survey 5. Vicinity Map RECOMMENDATION: 1. Receive Staff presentation 2. Open the public hearing 3. Take testimony from the Applicant and the public 4. Close public hearing and deliberate 5. Adopt Resolution (Attachment I) approving a Site Development Review for P A 06-005 Pool, Patio and More. PROJECT DESCRIPTION: The project site is located at 6175 Dublin Boulevard. The property is approximately .76 acres in size with a 10,584 square foot concrete tilt-up building and an attached trash enclosure. The existing building was approved on July 9, 1997 by the Community Development Director and was previously owned and occupied by RPL Graphics. The Applicant, Pool, Patio and More, is requesting Site Development Review (SDR) approval to modify the front fayade of the existing concrete tilt-up building (see Attachment 4). Pool, Patio and More is a general retail showroom that will sell outdoor furniture, barbeque equipment and accessories. Small items will be sold directly from this location and large items will be delivered directly to the customer from the Campbell store where their warehouse is located. ANALYSIS: The parcel at 6175 Dublin Boulevard (Assessor Parcel Number 941-0550-056-04) has a PD (Planned Development) zoning designation. Retail uses are allowed by right within the Planned Development (P A# 96-050). A Site Development Review is required for exterior modifications to an existing structure, including fayade renovations. The General Plan land use designation for the parcel is Retail/Office and COPIES TO: Applicant Property Owner File Page I of6 ITEM NO.: B. 2 G:\PA#\2006\06-005 Pool, Patio and More\Agenda Statement3.doc Automotive, which permits all retail/office uses and adds auto dealerships, auto body shops, and similar uses. Background: On March 18, 1997, the City Council adopted an Ordinance which rezoned a 7.5 acre parcel on the east side of Dougherty Road and on the north side of Dublin Boulevard (otherwise known as the BJ Dublin Commercial development) from the C-2, General Commercial Zoning District to a PD, Planned Development, Zoning District. On the same night, the City Council also adopted an Ordinance approving a Stage 2 Development Plan. The Stage 2 Development Plan includes the permitted and conditional uses and development standards. The Development Plan included conceptual architectural plans and required the design of the buildings to be compatible with the design of buildings in the development area. On July 9, 1997, the Community Development Director approved a Site Development Review to construct a 10,584 square foot concrete tilt-up building with an enclosed trash enclosure. The existing building was constructed and structurally engineered to meet the design of the building approved under the Site Development Review. The building was constructed and RPL Graphics began operation in the building in the spring of 1998 (the building is approximately 7 years old). RPL Graphics recently moved out of the building and the building was sold to Pool, Patio and More. On January 26, 2006, Pool, Patio and More applied for a Site Development Review to construct a fayade remodel of the existing building. Staff has worked with the Applicant and the Architect to design the improvements in such a manner that the improvements are compatible with the design of the existing building and the buildings in the vicinity. Site Development Review: A colored elevation is included with the project plans. Please note that the entrance element (tower) appears slightly taller than what the elevations show. The elevations show the actual proposed height (27 feet above grade). The colored elevations have been included to show what the proposed colors and materials will look like on the building. Existing Building The existing building was constructed as a concrete tilt-up building. The building was constructed for a printing service and was designed to meet the needs of a typical industrial business. The building has a simple rectilinear form (box) with few projections. Ornamental reveals (lines) are provided throughout the exterior of the building. Pilasters (or decorative columns), which are 16 feet and 15 feet in height are located on the front (south) elevation. The roof form is flat with a parapet wall which allows the existing mechanical equipment to be screened from view. At the top of the roof, a foam rounded embellishment has been added which is painted a different color from the body color of the building. The existing building is 20 feet high with an attached \3-foot, 6-inch high trash enclosure on the west side of the building. Although the elevations give the appearance that the trash enclosure is flush with the face of the building, the enclosure is actually set back approximately 66 feet from the face of the building (see the Site Plan for more information). The existing building has five small windows (approximately 13 feet tall x 5 feet wide) and one large window (approximately \3' tall x 16' wide). The existing windows extend down to the ground with black 20f6 metal covers over the top and lower window panels. The existing windows have dark glazing (glass) with grey frames. Landscaping was installed in conjunction with the Site Development Review for the building. Some of the existing landscaping has since died or is in poor shape. For this project, Staff has added Condition of Approval No. 20 which requires the Applicant to replace the missing, dead or damaged landscaping on the property prior to Final Building Inspection. The existing building was also approved with a "green wall" on the west and east elevations. The intent of the green wall was for vines to grow on wire lattice to screen the blank walls on the sides of the building. The existing vines have not grown up the side of the wall and therefore do not provide the visual break they were intended to provide. Staff has added Condition of Approval No. 21 which requires the Applicant to replant these vines and also requires that the vines show substantial growth within one year or they will be required to be replanted. Proposed Improvements The Applicant has proposed to make some minor improvements to the exterior skin of the building (see Attachment 3). No modifications are proposed to the overall form (shape) of the building. Due to the relatively young age of the building (7 years), the proposed improvements are only intended to give a minor facelift to the building. All improvements are proposed to the front of the building. Any exterior modifications will be limited due to the existing lot layout and location of the building and due to the fact that concrete tilt-up buildings are typically not constructed to allow future modifications to the building. Major modifications typically require significant structural changes to the building. Part of the proposal includes the removal offour ofthe six pilasters. The pilasters will be removed and the wall will be patched and painted. The existing locations of these pilasters are shown on the elevation in dashed lines. One major improvement to the front of the building will be a new tower element to announce the entrance to the store. The entrance will be 27 feet in height above grade and 25 feet 8 inches in width. The entrance feature will have a flat trim and flat cornice which will extend approximately 4 feet 6 inches away from the main wall of the feature. The cornice will extend on all sides of this architectural feature. A new sign will be constructed above the front entrance to the building. The new entrance feature will have a smooth stucco appearance so that the exterior skin ofthe element is consistent with the existing building materials which will remain. The overall form of the new architectural feature is consistent with the form of the existing building. Additionally, the projection away from the main wall of the building breaks up the shape and massing of the building and promotes a more exciting appearance for the building. The overall form and design of the building, as proposed, is consistent with buildings in the vicinity. At the new entrance to the building, the existing storefront door will be removed and replaced with a new French door with a window around the door to match the new windows. The door will be recessed from the main wall of this new element. The existing windows will be removed and replaced with new windows. The six existing windows will be replaced with three larger windows (\3 feet tall x 16 feet wide) and one smaller window (\3 feet tall x 5 feet wide). The windows will have bronze frames and grids (muntins). The new windows are similar in shape and size to the existing windows. The design of the new windows, which extend to the ground, is similar to the existing windows on the building and with windows in the vicinity. The overall shape, form, size and color of the windows are compatible with the buildings in the vicinity. A portion of the window will be blocked from view with a new fabric awning which will be black in color (see the colored elevation provided with the project plans). The awnings will also give the building a more attractive appearance by providing an element which projects away from the wall and thereby reduces the appearance of the boxy shape of the building. 30f6 In response to Staffs concerns regarding the existing rounded foam trim, the Applicant has proposed to remove this piece. Staff also expressed a concern regarding the difference in cornice treatment with respect to the existing building (which is flat) and the proposed tower element (flat in appearance with trim which projects away from the wall) to the Architect. In response to Staffs concerns regarding this issue, the Architect has included a rectangular trim which will not project away from the wall. While this trim relates better to the design of the tower element and the existing building than the rounded piece, Staff still has some concerns regarding the difference in the overall design between the two cornices. The different roof top designs (cornice) give the new element the appearance that the element has been "tacked on" rather than integrated into the design of the existing building which will remain. The varying design with respect to the cornice detail is also inconsistent with similar improvements in the vicinity and improvements along Dublin Boulevard which all share one cornice design. In order to promote a more attractive appearance for the building and to integrate the new architectural feature into the design of the existing building, Staff feels that the existing building cornice should be replaced with a cornice that matches the cornice on top of the architectural element. The new cornice will also provide an attractive addition to the existing building by eliminating the relatively flat appearance of the roof of the existing building. Staff has added Condition of Approval No. 17 which requires the Applicant to submit plans which show that the existing building will have a cornice to match the cornice shown on the tower element. The Applicant has also proposed to modify the existing colors of the building. The existing building features two main colors with a red color on the bottom portion of the building and a beige color which is the main body color for the building. The Applicant has proposed to repaint the building with earth tone colors (refer to colored elevations). The main body color of the building will be tan and the bottom portion of the building will have a darker tan color. The cornice at the top of the building will also have a dark tan color. Typical building colors in the vicinity vary. There are grey tones, earth tones, beige tones, etc. While the proposed color is darker than the existing building, the building color does fit in with the established color palette in the vicinity and the adjacent buildings. Parking Analysis: There are currently a total of 38 parking stalls on site. Based on the City of Dublin Off-Street Parking and Loading Requirements, 1 parking space per 400 square feet is required for retail sales of furniture/large applianceslflooring. The existing parking spaces exceed the City's parking requirement by 12 spaces. Parking Re uirement 26 spaces re uired 38 space provided Noticing Requirements: A Public Hearing notice for this project was sent to all property owners and residents/tenants within 300 feet of the subject property as required by state law. Review by City Departments: The Public Works Department, Building Division, Alameda County Fire Department, Police Services and Dublin San Ramon Services District have all reviewed the proposed project. Conditions of approval from these agencies are included in the proposed Resolution (Attachment I). 40f6 ENVIRONMENTAL REVIEW: The project has been reviewed under the California Environmental Quality Act, (CEQA), State CEQA Guidelines and the Dublin Environmental Guidelines, and the project has been found to be Categorically Exempt per CEQA Section 15301 (Minor alteration of existing facilities). CONCLUSION: This application has been reviewed by the applicable City departments and agencies, and their comments have been incorporated into the Conditions of Approval for the project. The proposed project, as conditioned, is consistent with the Dublin General Plan and the Planned Development Zoning District in which the project site is located and represents an appropriate project for the site. RECOMMENDATION: Staff recommends that the Planning Commission: 1) receive Staff presentation, 2) open the public hearing, 3) take testimony from the Applicant and the public, 4) close public hearing and deliberate, 5) adopt Resolution (Attachment 1) approving a Site Development Review for PA 06-005 Pool, Patio and More. 50f6 GENERAL INFORMATION: PROPERTY OWNER: Steven and Ginger Cohen, Season's Leisure, Inc. d.b.a. Pool Patio & More 3295 El Camino Real, Atherton, CA 94027 APPLICANT: Steven D. Cohen, Season's Leisure, Inc. d.b.a. Pool Patio & More 3295 EI Camino Real, Atherton, CA 94027 LOCATION: 6175 Dublin Boulevard, Dublin, CA 94568 (APN 941-0550-056-04) ZONING: Planned Development (PD) GENERAL PLAN LAND USE DESIGNATION: Retail/Office and Automotive SURROUNDING USES: Location Zoning General Plan Land Use Current Use of Property Site PD- Planned Retail/Office and Vacant (formerly RPL Development Automotive Graphics) North PD- Planned Business Park/Industrial Self Storage Facility Development and Outdoor Storage South M -1 - Light Industrial Business Park/Industrial Industrial Complex and Outdoor Storage East PD- Planned Retail/Office and Dental Office Development Automotive West PD- Planned Retail/Office and AutomobileN ehicle Development Automotive Repairs and Service ENVIRONMENTAL REVIEW: This project is Categorically Exempt from the environmental review requirements of the California Environmental Quality Act (CEQA) pursuant to CEQA Guidelines Section 15301, Class 1 (Minor Alteration to Existing Facilities). 60f6 RESOLUTION NO. 06- A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF DUBLIN APPROVING A SITE DEVELOPMENT REVIEW FOR A FAc;ADE REMODEL AND RELATED IMPROVEMENTS FOR POOL, PATIO AND MORE LOCATED AT 6175 DUBLIN BOULEVARD (APN 941-00550-056-04) P A 06-005 WHEREAS, Mr. Steven Cohen of Pool Patio and More ("Applicant"), has requested approval of a Site Development Review to construct exterior modifications to an existing building located at 6175 Dublin Boulevard; and WHEREAS, the Applicant has requested approval of fayade improvements including a new entrance, windows, doors, awnings, paint and trim; and WHEREAS, the California Environmental Quality Act (CEQA), together with the State guidelines and City of Dublin ("City") environmental regulations require that certain projects be reviewed for environmental impact and that environmental documents be prepared; and WHEREAS, the project has been found to be Categorically Exempt from the California Environmental Quality Act (CEQA), according to Section 15301, Class 1; and WHEREAS, the City of Dublin Planning Commission ("Planning Commission") held a Public Hearing on said application on February 28, 2006; and WHEREAS, the Planning Commission held a Public Hearing on said application on February 28, 2006; and WHEREAS, the Staff Report was submitted recommending that the application be conditionally approved; and WHEREAS, the Planning Commission did hear and consider all said reports, recommendations and testimony herein above set forth and used its independent judgment to evaluate the project. NOW, THEREFORE, BE IT RESOLVED that the City of Dublin Planning Commission does hereby find that: A. The proposed Project, as conditioned is consistent with the purpose and intent of Chapter 8.104, Site Development Review, of the Zoning Ordinance because: I) the facade improvements. as conditioned. will be attractive and will be compatible with similar improvements in the vicinitv as required bv Section 8.104.020.A of the Dublin Zoning Ordinance; 2) as conditioned the top of existing building (cornice) will be required to be modified to match the design of the cornice on the new architectural (tower) element so that the building shares one consistent design with respect to the top of the building and will therefore be compatible with the intent of the PD Zoning District in which it is located as required bv Section 8.104.020.C of the Dublin Zoning Ordinance; ATTACHMENT 1 3) there will be no changes to the existing site including the lavout. parking or landscaping; 4) as conditioned. the applicant will be required to replace dead or dying landscaping to improve the propertv; and 5) as conditioned. the design of the building will be compatible with the existing buildings in the vicinitv and the buildings on Dublin Boulevard. B. The proposed Project, as conditioned, will be compatible with the surrounding area and complies with the policies of the General Plan, with the development regulations or performance standards established for the Zoning District in which it is located and with all other requirements of the Zoning Ordinance because 1) the proposed facade improvement. as conditioned. meets the intent of the Dublin General Plan which discourages proiects which do not relate well to the surrounding buildings and as conditioned. the proposed remodel is compatible with the existing buildings in the area; 2) the proposed remodel is consistent with the requirements of the PD (Planned Development) Zoning District in which the building is located (PA-96-050); 3) the new architectural element on the building will be 27 feet in height from grade and will meet the requirements of the PD Zoning District which requires the building to have a maximum height of 45 feet above grade; 4) as conditioned. the proposed facade improvements will meet the intention of this PD Zoning District which requires buildings in the Zoning District to be compatible itself and with each other with respect to form. design and colors; and 5) the proposed improvements are intended to promote a more retail friendlv environment for the building and retail businesses are a permitted use under the PD Zoning District. C. The proposed Project, as conditioned, will not adversely affect the health or safety of persons residing or working in the vicinity, or be detrimental to the public health, safety and welfare because: 1) the design of the improvements. as conditioned. are compatible with the design of the existing building and buildings in the vicini tv; and 2) the proposed business and remodel will comply with all City of Dublin regulations. D. The approved site development, including site layout, structures, vehicular access, circulation and parking, setbacks, height, walls, public safety and similar elements, has been designed to provide a desirable environment for the development because: 1) the Applicant proposes to modify the exterior skin of the building and the interior of the building. and no changes are proposed to the site. layout or location of the building; and 2) as conditioned. the building will meet current requirements of the Municipal Code with respect to safetv. E. The subject site is physically suitable for the type, density, and intensity of the proposed Project and related structures because: 1) the intent of the proposed remodel is to allow the building to be redesigned in such a manner in order to promote a retail business and. as previously noted. retail businesses are permitted in this Zoning District; 2) the proposed improvements are minor in scale and are compatible with similar improvements and existing buildings in the vicinity. F. Impacts to views are addressed because: there will be no maior changes to the height of the building. with the exception of the new entrance. and the layout of the building will remain the same and therefore there will be no impacts to the existing views. G. There are no impacts to slopes or topographic features because: the site is relativelv flat and no changes are proposed to the layout of the building or the site other than the face of the building. 2 H. The character, scale and quality and design of the project is compatible with the proposed development, existing and approved projects in the area and with anticipated future development in the area because: I) the proposed improvements are intended to meet the needs of a retail businesses and the design of the building and improvements are compatible with businesses in the neighborhood; 2) as conditioned. the proposed improvements will be consistent with the form and shape of the existing building and therefore will be compatible with the buildings in the vicinity; 3) the proposed smooth stucco material on the new architectural element (entrance). is compatible with the existing building which is concrete with a smooth finish and with buildings in the vicinity which have a combination of CMU blocks. smooth stucco and concrete; 4) the new windows will be compatible with the design and shape of the existing windows and will have bronze frames and glass which are compatible with the existing building and the windows on the adiacent buildings; 5) the window openings and shape are compatible with the existing building which has a rectilinear shape and buildings in the vicinity which typicallv have a large amount of glass or have windows which extend to the ground. do not have trim around the windows and have muntins (grids); 6) the proposed improvements will include awnings over the new windows which are compatible with the design of the existing building and will promote an attractive appearance for the building by breaking UP the massing of the wall; 7) the overall building form will not change and will be compatible with the existing building and buildings in the neighborhood which have a relatively flat appearance with little articulation; 8) the new architectural element (tower) will be compatible with the existing shape of the building and will announce the entrance to the store and will promote visual interest of the building by providing an element which proiects awav from the main wall of the building and breaks UP the form and massing of the building; 9) the new element is compatible with buildings in the vicinity because it maintains the rectilinear form of the building and is compatible with the building forms in the vicinity; and 10) the proposal includes a new tower element with cornice which is different from the existing building. as conditioned. the existing building will be required to have a cornice treatment to match the new architectural element for architectural consistency between the two elements and to meet the design requirements of the Planned Development Zoning District. I. The landscaping will provide an attractive feature, will be compatible with the surrounding area and will conform to the Stage 1 Planning Development Zoning because: I) as conditioned. the Applicant will be required to replace all existing dead landscaping and any landscaping damaged as a result of the proposed improvements; and 2) as conditioned. the Applicant will be required to replant the existing vines on the side of the building which were required in coni unction with the original SDR for the building to screen the side ofthe wall and promote visual interest of the blank wall. J. The approval of the Site Development Review is consistent with the Dublin General Plan and any applicable Specific Plans because: 1) as conditioned. the proposed building improvements will promote an attractive remodel for the existing building; 2) the proposed improvements will result in a new design for an existing concrete tilt-up building and will be compatible with similar improvements in the neighborhood; and 3) the proposed improvements will allow the existing building to accommodate a retail use and will promote a new use in the area and the retail store will be compatible with businesses in the area. BE IT FURTHER RESOLVED that the City of Dublin Planning Commission does hereby conditionally approve P A 06-005, a Site Development Review application to construct a fayade remodel 3 and related improvements, as generally depicted by the Site Plan, Floor Plan and Elevations dated received February 13,2006, stamped approved and on file with the City of Dublin Planning Department, subject to the conditions below. CONDITIONS OF APPROVAL Unless stated otherwise, all Conditions of Approval shall be complied with prior to the issuance of building permits or establishment of use, and shall be subject to Planning Department review and approval. The following codes represent those departments/agencies responsible for monitoring compliance of the conditions of approval: [PL] Planning, [B] Building, [PO] Police, [PW] Public Works, [ADM] Administration/City Attorney, [FIN] Finance, [PCS] Parks and Community Services, [F] Alameda County Fire Department, [DSR] Dublin San Ramon Services District, [LDD], Livermore Dublin Disposal, [CO] Alameda County Department of Environmental Health, [Zone 7], Alameda County Flood Control and Water Conservation District, Zone 7, [LA VTA], Livermore Amador Valley Transit Authority, [CHS], California Department of Health Services. CONDITION TEXT RESPON. WHEN REQ'D SOURCE AGENCY PRIOR TO GENERAL 1. Approval. This Site Development Review approval is for PL Ongoing Planning the Pool, Patio and More Remodel, PA 06-005. The project shall generally conform with the project plans submitted by Robert Remiker Architects received February 13, 2006, on file in the Community Development Department, and other plans, text, and diagrams relating to this Site Development Review and Conditional Use Permit, unless modified by the Conditions of Approval contained herein. 2. Permit Expiration. Construction or use shall commence PL One year from DMC within one (1) year of Permit approval or the Permit shall permit approval 8.96.020.D lapse and become null and void. Commencement of construction or use means the actual construction or use pursuant to the Permit approval or demonstrating substantial progress toward commencing such construction or use. If there is a dispute as to whether the Permit has expired, the City may hold a noticed public hearing to determine the matter. Such a determination may be processed concurrently with revocation proceedings in appropriate circumstances. If a Permit expires, a new application must be made and processed according to the requirements of this Ordinance. 3. Time Extension. The original approving decision-maker PL One year from DMC may, upon the Applicant's written request for an extension permit approval 8.96.020.E of approval prior to expiration, and upon the determination that any Conditions of Approval remain adequate to assure that applicable findings of approval will continue to be met, grant a time extension of approval for a period not to exceed six (6) months. All time extension requests shall be noticed and a public hearing or public meeting shall be held as required bv the particular Permit. 4 CONDITION TEXT RESPON. WHEN REQ'D SOURCE AGENCY PRIOR TO 4. Permit Validity. This Site Development Review and PL Ongoing DMC Conditional Use Permit approval shall be valid for the 8.96.020.F remaining life of the approved structure so long as the operators of the subject property comply with the project's conditions of approval. 5. Revocation of permit. The Site Development Review PL Ongoing DMC and/or Conditional Use permit approval shall be revocable 8.96.020.1 for cause in accordance with Section 8.96.020.1 of the Dublin Zoning Ordinance. Any violation of the terms or conditions of this permit shall be subiect to citation. 6. Requirements aud Standard Conditious. The Applicant! Various Building Permit Standard Developer shall comply with applicable City of Dublin Fire Issuance Prevention Bureau, Dublin Public Works Department, Dublin Building Department, Dublin Police Services, Alameda County Flood Control District Zone 7, Livermore Amador Valley Transit Authority, Alameda County Public and Environmental Health, Dublin San Ramon Services District and the California Department of Health Services requirements and standard conditions. Prior to issuance of building permits or the installation of any improvements related to this project, the Developer shall supply written statements from each such agency or department to the Planning Department, indicating that all applicable conditions required have been or will be met. 7. Required Permits. Developer shall obtain all permits PW Building Permit Standard required by other agencies including, but not limited to Issuance Alameda County Flood Control and Water Conservation District Zone 7, California Department of Fish and Game, Army Corps of Engineers, Regional Water Quality Control Board, Caltrans and provide copies of the permits to the Public Works Department. 8. Fees. ApplicantlDeveloper shall pay all applicable fees in Various Building Permit Various effect at the time of building permit issuance, including, but Issuance not limited to, Planning fees, Building fees, Traffic Impact Fees, TVTC fees, Dublin San Ramon Services District fees, Public Facilities fees, Dublin Unified School District School Impact fees, Fire Facilities Impact fees, Alameda County Flood and Water Conservation District (Zone 7) Drainage and Water Connection fees; or any other fee that may be adopted and applicable. 9. Indemnification. The Developer shall defend, indemnifY, ADM Ongoing Administratio and hold harmless the City of Dublin and its agents, n/ City officers, and employees from any claim, action, or Attorney proceeding against the City of Dublin or its agents, officers, or employees to attack, set aside, void, or annul an approval of the City of Dublin or its advisory agency, appeal board, Planning Commission, City Council, Community Development Director, Zoning Administrator, or any other department, committee, or agency of the City related to this project to the extent such actions are brou!!ht within the 5 CONDITION TEXT RESPON. WHEN REQ'D SOURCE AGENCY PRIOR TO time period required by Government Code Section 66499.37 or other applicable law; provided, however, that the Developer's duty to so defend, indemnify, and hold harmless shall be subject to the City's promptly notifying the Developer of any said claim, action, or proceeding and the City's full cooperation in the defense of such actions or oroceedings. 10. Clean-up. The ApplicantlDeveloper shall be responsible PL Ongoing Planning for clean-up and disposal of project related trash to maintain a safe, clean, and litter-free site. 11. Modifications. Modifications or changes to this Site PL Ongoing DMC Development Review approval may be considered by the 8.104.100 Community Development Director if the modifications or changes proposed comply with Section 8.104.100 of the Zoning Ordinance. 12. Controlliug Activities. The ApplicantlDeveloper shall PL Ongoing Planning control all activities on the project site so as not to create a nuisance to the existing or surrounding businesses and residences. 13. Soft Foam Building Materials. Soft Foam (i.e. efis type PL Building Permit Planning material) may be installed no closer then 6 feet from the Issuance earth or oaved areas. 14. Accessory/Temporary Structures. The use of any PL Ongoing DMC accessory or temporary structures, such as storage sheds or 8.108 trailer/ container units used for storage or for any other purposes, shall be subject to review and approval by the Community Develooment Director. PROJECT SPECIFIC 15. Equipment Screening. All electrical and/or mechanical PL Building Permit Planning equipment shall be screened from public view. Any roof- Issuance mounted equipment shall be completely screened from view by materials architecturally compatible with the building Through and to the satisfaction of the Community Development Completion! Director. The Building Permit plans shall show the location Ongoing of all equipment and screening for review and approval by the Community Develooment Director. 16. Colors. The exterior paint colors of the buildings are PL Occupancy Planning subject to City review and approval. The Applicant shall paint a portion of the building the proposed colors for reVIew and approval by the Community Development Director prior to oainting the buildings. 17. Trim. The Building Permit plans shall show that the PI. Building Permit Planning existing flat roof will have a (trim treatment) cornice to Issuance match the proposed cornice on top of the new tower element. Prior to submitting plans for the Building permit, the Applicant shall submit one set of plans to the Planning Division showing the modification for review and approval by the Community Develooment Director. 18. New Architectural Element. The new architectural PI. Building Permit Planning 6 CONDITION TEXT RESPON. WHEN REQ'D SOURCE AGENCY PRIOR TO element (tower) shall be limited to 27' in height above Issuance lITade. 19. Window Signs. Window signs shall be limited in size to no PL Ongoing DMC more than 25% of the window opening as required by the 8.84 Dublin Zoning Ordinance. 20. Outdoor Display of Merchandise. Merchandise shall not PL Ongoing DMC be displayed outside of the building. Merchandise may only 8.108 be temporarily stored outside with a valid Temporary Use Permit has been obtained from the Planning Division. 21. Trash and Waste Accumulation. The applicant or any PL Ongoing Planning future owner shall provide and conduct regular maintenance of the site in order to eliminate and control the accumulation of trash, excess/waste materials and debris. LANDSCAPING 22. Laudscaping. The Applicant or Developer shall replace any PL Final Building PA-97-014 missing, dead or damaged landscaping per the approved Inspection Landscape Plan for PA-97-0l4, unless the Applicant applies for a Site Development Review Waiver to modify the approved Landscape Plan on the site prior to Final Building Insnection. 23. Vines. The Applicant shall replant the existing vines on the PL Final Building PA-97-0l4 side of the building prior to Final Building Inspection. Inspection Within one year the vines shall show substantial growth and shall begin to cover the wire to provide screening of the existing building as approved under PA-97-0l4, to the satisfaction of the Community Develonment Director. 24. Standard Plant Material, Irrigation and Maintenance PL Building Permit DMC Agreement. The Applicant/Developer shall complete and Issuance 8.72.050.B submit to the Dublin Planning Department the Standard Plant Material, Irrigation and Maintenance Agreement if anv landscaning will be renlaced on-site. BUILDING - GENERAL 25. Building Codes and Ordinances. All project construction B Through Building shall conform to all building codes and ordinances in effect Completion at the time of building nermit. 26. Bnilding Permits. To apply for building permits, B Issuance of Building Applicant/Developer shall submit five (5) sets of Building construction plans to the Building Division for plan check. Permits Each set of plans shall have attached an annotated copv of these Conditions of Approval. The notations shall clearly indicate how all Conditions of Approval will or have been complied with. Construction plans will not be accepted without the annotated Conditions of Approval attached to each set of plans. Applicant/Developer will be responsible for obtaining the approvals of all participating non-City agencies nrior to the issuance of building nermits. 27. Construction Drawings. Construction plans shall be fully B Issuance of dimensioned (including building elevations) accurately Building drawn (denicting all existing and nronosed conditions on Permits 7 CONDITION TEXT RESPON. WHEN REQ'D SOURCE AGENCY PRIOR TO site), and prepared and signed by a California licensed Architect or Engineer. All structural calculations shall be prepared and signed by a California licensed Architect or Engineer. The site plan, landscape plan and details shall be consistent with each other. 28. Addressing. Address will be required on all doors leading B Occupancy Building to the exterior of the building. Addresses shall be illuminated and be able to be seen from the street, 5 inches in height minimum. 29. Temporary Fencing. Temporary Construction fencing B Through Building shall be installed along the perimeter of all work under Completion of construction. Exterior Work 30. Cool Roofs. All new roofing or reroofing installed shall use B Through Building materials and installation standards approved under Title 24 Completion energy requirements. 31. Electronic File. The Applicant/Developer shall submit all B Issuance of Building building drawings and specifications for this project in an Building electronic format to the satisfaction of the Building Official Permits prior to the issuance of building permits. Additionally, all revisions made to the building plans during the project shall Final be incorporated into an "As Built" electronic file and Occupancy submitted prior to the issuance of final occupancy FIRE - GENERAL 32. Exit Signs. Exit signs shall be provided as required by the F Occupancy Fire CBC Chapter 10. 33. Fire Extinguishers. Provide 2AIOBC fire extinguishers, F Occupancy CFC 1002 in locations approved by the Fire Department, in the space. An approved SIgn III accordance with the Uniform Fire Code shall be conspicuously posted above the extinguisher. 34. Knox Box. Provide a Knox box at the main entrance to the F Issuance of CFC 902.4 space. The Knox box shall contain a key that provides access Building to the tenant space. Order forms for the Knox box are Permits available at the fire prevention office at the address above. The key can be placed in the box during the Fire Department inspection. 35. Address. Approved address numbers shall be placed on the F Issuance of CFC 901.4.4 space in such a position as to be plainly visible and legible Building from the street or road fronting the property. Said numbers Permits shall be placed on a contrasting background. 36. Codes. The project shall comply with Uniform Building and F Issuance of Fire Fire Codes as adopted by the City of Dublin. Building Permits FIRE - PROJECT SPECIFIC 37. Occupancy. The Building Permit plans shall state that the F Issuance of Fire building occupancy is "M". Building Permits 38. Fire Sprinklers. The sprinkler system shall be modified F Issuance of Fire as necessary to protect the storage in accordance with Building 8 CONDITION TEXT RESPON. WHEN REQ'D SOURCE AGENCY PRIOR TO NFP A 13. Any high piled storage shall comply with Permits CFC article 81. 39. Fire Sprinklers (TI). The sprinkler system shall be F Issuance of NFP A 13 modified as necessary to provide protection for the Building tenant improvement. Submit detailed shop drawings to Permits the Fire Department for approval and permit prior to installation. A separate permit fee is required. 40. Door Hardware. Door hardware on the exit doors shall F Issuance of CBC comply with CBC 1003.3.1.8. Building 1003.3.1.8 Permits POLICE - PROJECT SPECIFIC 41. Residential and Non-Residential Security Ordinance. PO Ongoing Police The ApplicantlDeveloper shall comply with all applicable City of Dublin Residential and Non-Residential Security Ordinance requirements. 42. Graffiti. The Applicant and Tenant shall keep the site clear PO Ongoing Police of graffiti vandalism on a continuous basis at all times. 43. Parking Signage. All entrances to the parking areas shall PO Occupancy Police be posted with appropriate signs as described in Sec. 22658(a) of the California Vehicle Code, to assist in removmg vehicles at the property owner' s/manager' s request. 44. Doors. Employee exit doors and doors to the rear of the PO Occupancy Police tenant space shall be equipped with 180-degree viewers if there is not a burglary resistant window pane in the door from which to scan the exterior. 45. Theft Prevention and Security Program. The Applicant PO Ongoing Police or Manager shall work with the Dublin Police on an ongoing basis to establish an effective theft prevention and securi tv program. 46. Emergency Response Card. The tenant shall complete a PO Occupancy Police "Business Site Emergency Response Card" and deliver it to the Dublin Police prior to occupancy. 47. Construction Phase Security. During the construction PO Through Police phase the Applicant and Developer shall conform to the Occupancy following security requirements: 1. The site shall have a security fence around the perimeter of all work under construction. 11. The site shall have lighting and the fence shall be locked when workers are not present. 111. A temporary address SIgn shall be posted of sufficient size and color contrast to be seen from the street during hours of darkness. IV. The Applicant shall file a Dublin Police "Business Site Emergency Response Card" prior to any phase of construction, which will provide 24-hour telephone contact numbers of persons responsible for the construction site. 9 CONDITION TEXT RESPON. WHEN REQ'D SOURCE AGENCY PRIOR TO v. Good security practices shall be followed with respect to storage of building materials and storage of tools at the construction site. PUBLIC WORKS - GENERAL 48. Erosion Control dnring Construction. PW Issuance of Public Works Applicant/Developer shall include an Erosion and Sediment Grading! Control Plan with the Grading and Improvement plans for Sitework Permit review and approval by the City Engineer and/or Public Works Director. Said plan shall be designed, implemented, and continually maintained pursuant to the City's NPDES permit between October I" and April 15th or beyond these dates if dictated by rainy weather, or as otherwise directed by the City Engineer and/or Public Works Director. All grading, construction, and development activities within the City of Dublin must comply with the provisions of the Clean Water Act. Proper erosion control measures must be installed at development sites within the City during construction, and all activities shall adhere to Best Management Practices. 49. Water Quality/Best Management Practices. Pursuant to PW Issuance of Public Works the Alameda Countywide National Pollution Discharges Grading! Elimination Permit (NPDES) No. CAS0029831 with the Sitework Permit California Regional Water Quality Control Board (RWQCB), the applicant shall design and operate the site in a manner consistent with the Start at the Source publication, and according to Best Management Practices to minimize storm water pollution. All trash dumpsters and compactors which are not sealed shall have roofs to prevent contaminants from washing into the storm drain system. All storm drain inlets serving vehicle parking areas shall be fitted with Filter Devices to remove Hydrocarbons and other contaminants, and all storm drain inlets shall be stenciled "No Dumping ~ Drains to Bay" using an approved stencil available from the Alameda Countywide Clean Water Program 50. Parking Lot Lights. The Applicant/Developer shall PW Occupancy Public Works provide photometric calculation for the existing parking lot and around the building that demonstrates a minimum foot- candle lighting level of not less than 1.0 at the ground surface for the adjacent parking area; if this cannot be verified provide additional lighting where necessarv. 51. Disabled Parking. All disabled parking stalls shall meet PW Issuance of Public Works State Title 24 requirements, including providing curb ramps Building at each loading zone. Curb ramps cannot encroach within Permits and the loading/unloading areas. Disabled stalls shall be Occupancy conveniently located and grouped near the prImary entrances to each building. Van accessible stalls shall also be provided and shall meet State Title 24 requirements. 10 CONDITION TEXT RESPON. WHEN REQ'D SOURCE AGENCY PRIOR TO 52. Vehic1e Parking. Applicant shall repair any distressed areas PW Occupancy Public Works of pavement within the existing parking field, then seal and re-stripe the entire parking field. All parking spaces shall be double striped using 4" white lines set approximately 2 feet apart according to Figure 76-3 and 98.76.070 (A) 17 of the Dublin Municipal Code. All compact-sized parking spaces shall have the word "COMPACT" stenciled on the pavement within each space. 12" -wide concrete step-out curbs shall be constructed at each parking space where one or both sides abuts a landscaped area or planter. Wheel stops as necessary shall be orovided at the oarkin!! stalls. 53. Temporary Fencing. Temporary Construction fencing PW During Public Works shall be installed along perimeter of all work under Construction construction to separate the construction operation from the public. All construction activities shall be confined to within the fenced area. Construction materials and/or equipment shall not be operated or stored outside of the fenced area or within the public right-of-way unless approved in advance by the City EngineerlPublic Works Director. 54. Construction Honrs. Construction and grading operations PW During Public Works shall be limited to weekdays (Monday through Friday) and Construction non-City holidays between the hours of 7:30 a.ill. and 5:30 p.m. The Applicant/Developer may request permission to work on Saturdays and/or holidays between the hours of 8:30 am and 5:00 pm by submitting a request form to the City Engineer no later than 5:00 pm the prior Wednesday. Overtime inspection rates will apply for all Saturday and/or holidav work. 55. DamagelRepairs. The Applicant/Developer shall be PW Prior to Public Works responsible for the repair of any damaged pavement, curb & Acceptance of gutter, sidewalk, or other public street facility resulting from Improvements construction activities associated with the development of by City Council the proiect. 56. Fees. The Developer shall pay all applicable fees in effect PW Issuance of Public Works at the time of building permit issuance including, but not Building limited to, Planning fees, Building fees, Dublin San Ramon Permits Services District fees, Public Facilities fees, Dublin Unified School District School Impact fees, Public Works Traffic Impact fees, Alameda County Fire Services fees; Noise Mitigation fees, Inclusionary Housing In-Lieu fees; Alameda County Flood and Water Conservation District (Zone 7) Drainage and Water Connection fees; and any other fees as noted in the Develooment Agreement. PUBLIC WORKS - STANDARD CONDITIONS 57. In the event that there needs to be clarification to these PW Improvement Public Works Conditions of Approval, the Community Development Plans Director and the City Engineer have the authority to clarify the intent of these Conditions of Approval to the Developer without going to a public hearing. The Community II CONDITION TEXT RESPON. WHEN REQ'D SOURCE AGENCY PRIOR TO Development Director and the City Engineer also have the authority to make minor modifications to these conditions without going to a public hearing in order for the Developer to fulfill needed improvements or mitigations resulting from impacts of this proiect. 58. Construction activities, including the maintenance and PW Through Public Works warming of equipment, shall be limited to Monday through Completion Friday, and non-City holidays, between the hours of 7:30 a.m. and 5:30 p.m. except as otherwise approved by the City Engineer. DUBLIN SAN RAMON SERVICES DISTRICT (DSRSD) - STANDARD CONDITIONS 59. Prior to Issuance of any building permit, complete DSR Issuance of Dublin San improvement plans shall be submitted to DSRSD that Building Ramon conform to the requirements of the Dublin San Ramon Permits Services Services District Code, the DSRSD "Standard Procedures, District Specifications and Drawings for Design and Installation of Water and Wastewater Facilities", all applicable DSRSD Master Plans and all DSRSD policies. 60. Prior to issuance by the City of any Building Permit or DSR Issuance of Dublin San Construction Permit by the Dublin San Ramon Services Building Ramon District, whichever comes first, all utility connection fees Permits Services including DSRSD and Zone 7, plan checking fees, District inspection fees, connection fees, and fees associated with a wastewater discharge permit shall be paid to DSRSD in accordance with the rates and schedules established in the DSRSD Code. 61. The applicant shall hold DSRSD, its Board of Directors, DSR Issuance of Dublin San commissions, employees, and agents of DSRSD harmless Building Ramon and indemnify and defend the same from any litigation, Permits Services claims, or fines resulting from the construction and District completion of the proiect. 12 PASSED, APPROVED AND ADOPTED this 28th day of February, 2006, by the following vote: AYES: NOES: ABSENT: ABSTAIN: Planning Commission Chairperson ATTEST: Planning Manager G:\PA#\2006\06-005 Pool, Patio and More\PC Reso Approve SDR.DOC 13 .. .. Robert Remiker ARCHITECT REceiVED JAN 2 6 2006 DUBLIN PLANNING Pool, Patio, and More 6175 Dublin Blvd. L PooL Patio, and More proposes to use the existing facility at 6175 Dublin Blvd. as a retail showroom, featuring outdoor furniture, barbeques, and accessories. In the "off.season", decorative holiday items are also featured. 2. The facility will employ 7 people. 3. The hours of operation are 10:00 a.m. to 6:00 p.m. weekdays, 10:00 a.m. to 6:00 p.m. Saturdays, and 11:00 a.m. to 5:00 Sundays. 4. Because the retail operation sells smaller items from this location, with larger items shipped from a central warehouse offsite, the business does not produce high traffic volumes for deliveries, does not produce high volumes of waste, does not engage in manufacturing processes, does not utilize chemicals in its operation, and does not emit any hazardous by-products as a result of its operation. 5. The project makes use of the parking, circulation, and access systems already in place. Deliveries and customer traffic patterns will remain as originally designed in the Planned Development approved in 1996. 6. The site accommodates the proposed retail store and exceeds the required parking required for this use. 7. The improvements are primarily interior. The most substantial exterior modification is made at the building entry, creating an enlarged ~ade surrounding the doors. This entry ''tower'' will not affect views from adjacent properties and is in scale with similar building features in the surrounding properties. The motel to the west remains substantially taller than the proposed entry feature. 8. The site is primarily flat, with drainage channeled to catch basins, and area drains. No modification to the topography or site is proposed. No modifications to drainage systems are required. 9. The modifications to the building include the enlargement of storefront windows, the addition of awnings at the storefront windows, and the addition of a ''tower'' to enhance the character of the tilt-up structure, provide an opportunity for signage, and to enhance the "identity" for the new tenants. While the existing tilt-up building is largely unchanged, the entry tower follows a pattern quite common to retail tenants in Dublin (Safeway, Expo, etc.). Its coloration will be sophisticated and suDdued and will not present any conflict with the identity of adjacent properties. 10. The landscape, with ground cover, evergreen and deciduous trees has matured to a level where it already provides visual relief, masks the electrical transformer, softens the edges of the parking areas, and provides continuity with the adjacent properties in the Planned Development. No changes are required or proposed at this time. I L The proposed project is not located on a hazardous waste and substance site pursuant to Government Code Section 65962.5 2233 Fifth Street Berkeley, California 94710 (510) 644-8099 Fax(SIO) 644-3337 robrem@sbeglobal.o.t ATTACHMENT 2 . SIT E DES..GN ... REVIE Tenant Improvement: 'Pool Patio & More 6175 Dublin Blvd., Dublin, CA 94568 PESCRIPflON OF WORK TeNNrt. ~ilIan I!OlIetlne ~I properl!f~tl1t:-upMlfleanol wood p_1z&:t roof. Tht lDd:miOr MlI'k ilIoIudee the conetructlOn or a IIIlW dIItr)I- and _ aluminum ~ wlIIdowI I\fth !Wnted WDC<l dIItr)I o:Ioor& and flI11r1c -. Tht roll met.Ii roll up door will be ~ All ~ _o:Ioor& and wIndoMI wtI1 be paIIItN to matoh _1ftOretro~ mateo1llL Tht bu11dIne MIl be painted In the four ooIor ll<lhIIM ehowi1ln the eIevlrtlone. IIlteI10r wori: MIl ilIoI...... new partItIDII walla. N1W1IMwroom Uehtlne. nlftl1lehod fIoor1ne and oai>lnetr)' !!.elated ~ atruotural.eleotr1oal and rooIIne MlI'k will occur. 1UILlIIN/lI'I'IPBo v-N:~ OCCUI'AHCY.5 INPEX AD A1 A2 ElcIatIne Site & Roof f'lan. I'ropclNd 5Ite and RDol' f'lan. ExIatlne EIoMrtIon, ~ Map. 'nde., !'roject Deecr1ptlon. !'rojeCt Data !'ropclNd FIoorf'1an !'ropclNd EIiMrtlone PROJECT DATA .ffi VIobIl$)' Map \3!7 NQ.(f' &lII8llIIG 8IlI AJaA 1'MI'OellIl8lTll ADA _G f'\.OOR /o'IZ.Ao ACTUAL 5LDG CO\'1lItI!l)_1INCI.08lJtU!I8TOItASl! -'100 04. IJIICHANGIII) lO,llIl4..f. Iff! a". It.Oe1 04. U_ lift I'MI'OellIll'l.OOlt ADA LOr _ CO\'IRME UNCHANGIIIl NUMIIl!R OF l'i\IOONG 6'l'ALLSIlEQUlUl) (1I<lOO5.F.) 2& NUMIIl!R OF I'AltIaNG 6'l'AIJ.& I'ItOI'IPIP a& I'IItCIIN'I' OF I.AIIll8CAI'ING (NO!' INCLUDING B1D1!WALJ; 1UU) IUS NUMlBIt OF IMI'LOY!1!S 1M LAIlBES1'llHlI'I' ., I'ItII'IOU8 U8! l'IlIIl11NG FAClU1Y I'IWI'OIIlIl uee: ItETAlLllTORE ~"LAItGl! AI'I'UANCI!S) ffi South Eaet VIew - ExIetIng BuIldIng \:3!INTS EB 1:1 L-- I I ~11l ~I~ '"I I I I r-- i l - NOmt @ EldetIng Site and Roof Plan At NQ.(f' -- ............ h z L-- , , ~11l ~I~ '"I I , I r-- .1 ~ tl · MOllo NO~AI&~'fO 11I)- ~ SOUT ........00 .L:D Eldetlng Elevation. ~ 1I&"-f'.(f' ffi propoHd Site and Roof Plan ~ 1"a'JD.u' RECEIVEO FES 1 3 ZOOS DUBLIN PL~''fI'~ 'I\) _ BY I ~~ I ~t.1 I ~!~ = '{illl ~Ii -I !~iSf' 1~5 I ~ c o. i~ -t. UJ_ 1:SlL. cC,) _Ill ~~ ;n~ .lD ie' I\:L\.. 't~ ~1 115-: ~fi" U)~ 1:Sl~ Cc i1i ;n> \'f) I- :z u.J - 1-26-00 :a5 - M> NOTED :I:: (..) !lllom I;56Il'C ~ Jab Cle20 - !;;: Al cp , I , llIllIo!lII ~ 1 1IUIl"8I'ID(J(f'1Il)CNC11Y I ..-........ &atz:lMDCI\N\.Il3HT5'T'l'1'. , .fJfI-(I'MlMP'. f i , ~ i , , , I , <f , I , ---iEJ @ Propoeed Plan A2 W".f.(f' uc...... , ! (N),MJmQN I~"~ i , I , , I , ! r---- I I I i I I I I i 1.___-2 , Pilll;q r-lM~~'" :----11 l<imr~ m= ---___1______-1I_____________L___ I iLl (!)ClllMI ,.... i\- t I (l)COUMl ~____-+I fEr> i I WAIN~ 1 i r-----'! ,I I I I I I ' ,I I I I ' ,I I I I I I ' , ------ I I ' """" ' I ~~-<P ! i I i r-- --, I I I G1m I I TYI'..CNlOP'Ilt llil I I I I ]---;';--1 , 0..1.. r"'5 o 0 (II ~ 0 c I (I) ~------ , II I I'=:rr I I Ii I I II I I I' I ------1 I I , I =-.....=.. , fWOIIOIDUIf \...., , I i , I r---- I I I I I I I 1..____ r---- I I I I I I I 1.____ I ~W?=.'" ~ ~ - -~ .J' rolTlClN~ W?='" ' E9 Ul'IItIINCl! NOIml RECEIVED FES 1 3 2006 DUBLIN PLANNI"lG ~! ~ ~t I ; lit t l~ UldJ C \IS E: "'lS lD III Q D- e L\.. _ 1-26-06 _ M> NOTED !lllom I;56Il'C lab 0!520 - A2 SOUTH -.. ='(11'11I)"""""" --------- NOUH (I!)_HlD_""""""," -- - ------ (N)8<\'UlIHT1lI!'l'ClNl> __(OtLlllH1lllJ r.q-. ~~~~~ NlWmcr~CQlNDlJt:IIt ltIta!l"LJaHALP'm.N) AU. (N)"""""'_ '::it/: 00......... CNNM....... T"IP. ...- rAlllU . .........., -- ........... -- !!Q!!lNO_G.~~ IIDlCM i'W.MIOUNCI FCW.C mAIL HJ. .... ,^'tOf 1!VB'I'DWalICw.'fINCf,.II:EGIMII)~ ~~- ~ r<fn \- _OP!NIIO&\ CD M \ j / I X~V~~ X c . XX ... ,....... ~'\..Xxx ?- X > - ~~ ~ XX J JV,"" v.... v... "- WEST 00..........,. '\ "'-iIl_lA1'I1CE -- L(D o IWlE COI.OR" ENTRYT~ eeNJAMIN MOClIlE #HV69 "MiITEIWI. e<<lJIM' CD lIODYCCl..OI:: IIeNJAMIN _1fHCo8& '~GOI.D" CD IWlECOl.OI:.IleNJN04INMOOUIHC.'16'D^~TNr o (C) e~1I:El'!.JNT: eeNJNo4lN ~ ~MIX'DEEI'SRONZE" <]) M'NING FNlI:IC: SUN~~UA 'FIRES15T" BVa.1aeo&-OOOO RECEIVED FES 1 3 Z006 ~ Propoeed EllMItlone lI&".r.(f' DUBLIN PLANI~!"',\) __ BY I ~t) J ~f i s cld/5! ~ J.ii t I~ ~I j ~f J~5 ~ ~IQ III C o a ~ lD m ~ lD Ul o ~ 2 L\.. _ 2-15-00 _ M NOTED !lllom I;56Il'C Jab 0!52D - A3 SOUfH r-'" I - - - -- -- --...- - -. - _.',~ --- r- - -. ------ [--\ ~, F> ~ - --, ~,.,'" 'Ll'..",":JCT: ,w rOOL rmo I NOIE _:~~-..:l~~~~~- -~ o WESf l.iJI II II .- l' ~ I 11:II t:J ~- ~"~-:'._.'".'''.:..~:~' '.~::5~ ',' . ~'_ _, '_'C:(';'~~~:'\~~ "c",...: _'co, ".' "" .... L1l1J III [I [I a a a t:J r A!H WoiJ ~ I 11"1 In I I r llr-. r.-------...--- - [ I L NOI1TH r I :;; Photo Survey ..~.. iJ'.~ .f..... '<,.',,_., .-.,,_ ~~i';;';'..~. ~;fli*";"!'''';?:l''''''':"{. Existing Building. Existing building and adjacent building (6129 Dublin Blvd.) ATTACHMENT lf View of the side of the existing building and adjacent building. View of the Cook's Collision building (6091 Dublin Blvd.). View of the Car West Auto Body Building (9077 Dublin Blvd.). View ofthe Kassabian Motors building (across the street - 6080 Dublin Blvd.). Vicinity Map - 6175 Dublin Boulevard N SCALE 1 : 4,261 600 i~ '"" -......,.., -- --T-------T 200 0 200 400 FEET u: ATTACHMENT 5 http://mapguide/mwf/Dublin.mwf Tuesday, February 21,20063:12 PM