NOTES
1. DRIVEWA Y WIDTH SHALL BE 20' MAX. FOR RESIDENTIAL AND 35' MAX. FOR COMMERCIAL.
2. WEAKENED PLANE JOINTS REQUIRED ON CENTERLINE FOR DRIVEWAYS 10' TO 20' WIDE. DRIVEWAYS
22' TO 35' WIDE SHALL HAVE TWO WEAKENED PLANE JOINTS EVENLY SPACED AT 1/3 AND 2/3
POINTS.
3. ALL CONSTRUCTION AND MATERIALS IN CONFORMANCE WITH CITY OF DUBLIN STANDARD
SPECIFICA TIONS.
4. THICKNESS OF APRONS SHALL BE 6" ON RESIDENTIAL DRIVEWAYS AND 6" ON COMMERCIAL
DRIVEWAYS. ON COMMERCIAL DRIVEWAYS. SIDEWALK SHALL BE REMOVED AND REPLACED WITH 6"
OF CONCRETE.
GU TTER
REMOVE ENTIRE CURB AND GUTTER
POUR AS ONE UNIT *
1" fCURB AND GUTTER CD-300
1, ,,'--10% MAX. __u
I I~ __ __ ...- __ ~
-.....
-. APRON
#4 @ 18" OC
80TH WAYS
SECTION A-A WITH VERTICAL CURB
_2%
12% MAX.
---
..-
~
or
DRIVEWA Y
LEGEND
*
IF CURB AND GUTTER ARE POURED
SEPARATE OF APRON THEN DOWELS ARE
REQUIRED AT BACK OF CURB. 3" IN
CURB AND 9" IN CENTER OF APRON.
SEE DETAIL BELOW.
1"1:(;- ~~~~ _~~~ _~U_~T~~_ ~~=-_3~00
I 36" WIDTH OF DRIVEWAY
· TOP OF CURB 'I' A BACK OF WALK
WEAKENED PLANE JOINT
DRIVEWAY DETAIL WITH PlANTER STRIP
SCALE: NOT TO SCALE
DATE: SEPTEMBER 13. 2006
DRAWN BY: LDH
V:\CAD\NEW STANDARDS
CD-I08