HomeMy WebLinkAboutCD-400 Convert Existing Drop Inlet to Manhole
.1
N
........... N
I ...........
I
v
GROU~ r J
,.
INSTALL MANHOLE
FRAME AND COVER
FINISH PAVEMENT
FRAME AND COVER
REMOVED FOR CLARITY
7 1/2'J
#4 BAR
STRAIGHTEN AND
TRIM EXISTING
#4 BAR
2'-9"
en en
I I
'to N
SECTION A-A
PLAN
FINISH
PAVEMENT
-------------D
I
I -------,
L: . , ~ - REMOVE EXISTING BOX
_e #4 BAR : ...: DEPTH TO SUIT
FIELD CONDITIONS
6"
I. 4' -0" .1
SECTION B-B
NOTES:
1. ALL CONCRETE SHALL BE CLASS "A"
2. STEEL SPACING SHALL BE 1-1/2" MIN.
3. CLEARANCE SHALL BE 2" MIN.
CONVERT EXISTING DROP INLET TO MANHOLE
SCALE: NOT TO SCALE
DATE: SEPTEMBER 13, 2006
DRAWN BY: LDH
V:\CAD\NEW STANDARDS
APPROVED: . ~
~~~~
PUBLIC WORKS DIRECTOR CD-400