Loading...
HomeMy WebLinkAboutCD-601 Rigid Conduit Stub Detector Lead In 2" AC 12"MIN. DUXSEAL DAM, REMOVE EXISTING BEFORE PA~NG PAVEMENT EPOXY lOR PREFINAL -f:..:. SEALAN~ _ _ -L LIFT. ~ TAPER SAWCUT TJ 5-1/2" DEEP OR BOTTOM OF PA~NG CONDUIT (SEE TABLE) DUXSEAL (OR EQUAL) A T BUSHING SAND BACKFILL. SEE NOTE 5. 4" SLACK MIN. SECTION AT CONCRETE CURB AND GUTTER MEDIAN CURB PULL BOX DUXSEAL DAM REMOVE EXISTING "0: ' PAVEMENT 18" BEFORE PAVING [OR PREFINAL (2 _ AC ~ EPOXY SEALANT _ _ _ UFT CTAPER -;AWCUT TO t 5-1 /2" DEEP OR BOTTOM OF PA~NG EXISTING PAVING CONDUIT (SEE TABLE) DUXSEAL (OR EQUAL) AT BUSHING SAND BACKFILL. SEE NOTE 5. 4" SLACK MIN. SECTION AT MEDIAN CURB 12" MIN. SAWCUTS PLAN 2" MIN. CONDUIT TABLE MIN SIZE # OF CONDUIT WIRES 1" 1-6 1-1/2" 7-16 2" 17-24 :z ~ o . N ~ NOTES: 1. NON-METALLIC BUSHING SHALL BE USED AT ROADWAY END OF CONDUIT. 2. TAPE WIRE 3 INCHES EACH SIDE OF ROADWAY BUSHING. 3. ROUND ALL SHARP EDGES WHERE WIRE HAS TO PASS. 4. DO NOT USE ELECTRICAL 'L' AT FINISH POINT. 5. REMOVE ALL DEBRIS AND LOOSE MATERIAL PRIOR TO PLACING SAND BACKFILL. RIGID CONDUIT STUB DETECTOR LEAD IN SCALE: NOT TO SCALE DATE: SEPTEMBER 13, 2006 DRAWN BY: LDH V:\CAD\NEW STANDARDS APPROVED: ~h';h~ PUBL WORKS DIRECTOR CD-60 1