HomeMy WebLinkAboutCD-601 Rigid Conduit Stub Detector Lead In
2" AC
12"MIN.
DUXSEAL DAM, REMOVE EXISTING
BEFORE PA~NG PAVEMENT
EPOXY lOR PREFINAL
-f:..:. SEALAN~ _ _ -L LIFT.
~ TAPER SAWCUT TJ
5-1/2" DEEP OR
BOTTOM OF PA~NG
CONDUIT
(SEE TABLE)
DUXSEAL (OR EQUAL)
A T BUSHING
SAND BACKFILL. SEE NOTE 5.
4" SLACK MIN.
SECTION AT CONCRETE CURB AND GUTTER
MEDIAN CURB
PULL BOX
DUXSEAL DAM REMOVE EXISTING
"0: ' PAVEMENT
18" BEFORE PAVING [OR PREFINAL
(2 _ AC ~ EPOXY SEALANT _ _ _ UFT
CTAPER -;AWCUT TO t
5-1 /2" DEEP OR
BOTTOM OF PA~NG
EXISTING
PAVING
CONDUIT
(SEE TABLE)
DUXSEAL
(OR EQUAL)
AT BUSHING
SAND BACKFILL. SEE NOTE 5.
4" SLACK MIN.
SECTION AT MEDIAN CURB
12" MIN.
SAWCUTS
PLAN
2" MIN.
CONDUIT TABLE
MIN SIZE # OF
CONDUIT WIRES
1" 1-6
1-1/2" 7-16
2" 17-24
:z
~
o
.
N
~
NOTES:
1. NON-METALLIC BUSHING SHALL BE USED AT ROADWAY END OF CONDUIT.
2. TAPE WIRE 3 INCHES EACH SIDE OF ROADWAY BUSHING.
3. ROUND ALL SHARP EDGES WHERE WIRE HAS TO PASS.
4. DO NOT USE ELECTRICAL 'L' AT FINISH POINT.
5. REMOVE ALL DEBRIS AND LOOSE MATERIAL PRIOR TO PLACING SAND BACKFILL.
RIGID CONDUIT STUB DETECTOR LEAD IN
SCALE: NOT TO SCALE
DATE: SEPTEMBER 13, 2006
DRAWN BY: LDH
V:\CAD\NEW STANDARDS
APPROVED:
~h';h~
PUBL WORKS DIRECTOR CD-60 1