Loading...
HomeMy WebLinkAboutCD-701 Stabilized Construction Entrance 50' MIN. ~ PUBLIC 8" MIN. ~T-OF-WAY ~ ~~ Jr_ (EXISTING GROUND I. 50' MIN. PROVIDE APPROPRIATE TRANSITION BETWEEN STABILIZED CONSTRUCTION ENTRANCE AND PUBLIC RIGHT-OF-WAY 16' MIN. PROFILE PUBLIC RIGHT- OF-WAY 08~~ PLAN NOTES: 1. THE MATERIAL FOR CONSTRUCTION OF THE PAD SHALL BE 3 TO 4 INCH STONE. 2. THE THICKNESS OF THE PAD SHALL NOT BE LESS THAN 8 INCHES. 3. THE WIDTH OF THE PAD SHALL NOT BE LESS THAN THE FULL WIDTH OF ALL POINTS OF INGRESS OR EGRESS. 4. THE LENGTH OF THE PAD SHALL BE AS REQUIRED, BUT NOT LESS THAN 50 FEET. 5. THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION THAT WILL PREVENT TRACKING OR FLOWING OF SEDIMENT ONTO PUBLIC RIGHTS-OF-WAY. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH ADDITIONAL STONE AS CONDITIONS DEMAND, AND REPAIR AND/OR CLEANOUT OF ANY MEASURES USED TO TRAP SEDIMENT. ALL SEDIMENT SPILLED, DROPPED, WASHED OR TRACKED ONTO PUBLIC RIGHTS-OF-WAY SHALL BE REMOVED IMMEDIA TEL Y. 6. WHEN NECESSARY, WHEELS SHALL BE CLEANED TO REMOVE SEDIMENT PRIOR TO ENTRANCE ONTO PUBLIC RIGHTS-OF-WAY. WHEN WASHING IS REQUIRED, IT SHALL BE DONE ON AN AREA STABILIZED WITH CRUSHED STONE THAT DRAINS INTO AN APPROVED SEDIMENT TRAP OR SEDIMENT BASIN. ALL SEDIMENT SHALL BE PREVENTED FROM ENTERING ANY STORM DRAIN, DITCH OR WATERCOURSE THROUGH USE OF SAND BAGS, GRAVEL, BOARDS OR OTHER APPROVED METHODS. STABILIZED CONSTRUCTION ENTRANCE SCALE: NOT TO SCALE DATE: SEPTEMBER 13, 2006 DRAWN BY: LDH V:\CAD\NEW STANDARDS APPROVED: . ~"-ff~ . PUBLI WORKS DIRECTOR CD- 7 01