HomeMy WebLinkAboutReso 088-00 Home Depot SDR RESOLUTION NO. 88 - 00
A RESOLUTION OF THE CITY COUNCIL
OF THE CITY OF DUBLIN
APPROVING THE SITE DEVELOPMENT REVIEW FOR
THE HOME DEPOT EXPO DESIGN CENTER DEVELOPMENT PA 99-029
WHEREAS, Kirk Bezanson, on behalf of Home Depot U.S.A., Inc. has requested approval of
a Site Development Review to allow a 93,130 square foot Home Depot EXPO Design Center on a
cleared lot in the Dublin Place Shopping Center located between the Montgomery Ward and Target
stores; and
WHEREAS, a Complete application f0r the above noted entitlement request is available and on
file in the Department of Community Development; and
WHEREAS, Applicant/Developer has submitted project plans for a Site Development Review for
the Home Depot EXPO Design Center dated received November 15, 1999, and a colors and materials
board dated received November 15, 1999, and
WHEREAS, the City prepared an Initial Study to evaluate site-specific impacts of the project.
Based on the Initial Study, the City prepared a Mitigated Negative Declaration and Mitigation Monitoring
Program for the project with the finding that although the project could have a significant effect on the
environment, there will not be a significant impact in this case because revisions in the project have been
made or agreed to by the project proponent and because a Mitigated Negative Declaration will be adopted
that mitigates any impacts of the project to a level of insignificance through the adoption of mitigation
measures and a Mitigation Monitoring Program; and
WHEREAS, the Planning Commission has reviewed the initial study recommended that the
City Council adopt the Mitigated Negative Declaration for site-specific impacts from this Project; and
WHEREAS, the Planning Commission did hold a public hearing on said application on May
23, 2000 and recommended that the City Council approve the Site Development Review for this
project; and
WHEREAS, proper notice of said public hearing was given in all respects as required by law;
and
WHEREAS, the Planning Commission transferred original hearing jurisdiction for this project to
the City Council pursuant to Section 8.96.020.C.3 of the Zoning Ordinance.
WHEREAS, the Planning Commission recommended City Council approval of the Mitigated
Negative Declaration, Mitigation Monitoring Program, and Site Development Review for this project on
May 23, 2000; and
WHEREAS, the City Council did hold a public hearing on said application on June 6, 2000 for
this project; and
WHEREAS, proper notice of said public hearing was given in all respects as required by law;
and
WHEREAS, a Staff'Report was submitted recommending that the City Council approve
Negative Declaration, Mitigation Monitoring Program and the Site Development Review, subject to
conditions; and~
WHEREAS, the City Council did hear and use their independent judgment and considered all
said reports, recommendations, and testimony hereinabove set forth.
NOW, THEREFORE, BE IT FURTHER RESOLVED THAT TFIE City Council of the City
of Dublin does hereby make the following findings and determinations regarding said proposed Site
Development Review:
Ao
Approval of this applicatiOn is consistent with the purpose and intent of this Chapter because a
Bathroom and Kitchen equipment display and sales facility is a retail use permitted within the C-1
(Retail Commercial) Zoning District.
The project is consistent with Development Zone 7 of the Downtown Specific Plan, which allows
retail, uses, and is within and consistent with the Retail/Office designation of the General Plan and
the C-1 (Retail Commercial) Zoning District which allow retail uses.
The approval will not adversely affect the health or safety of persons residing or working in the
vicinity, or be detrimental to the public heakh, safety and general welfare because a Mitigated
Negative Declaration and associated Mitigation Monitoring Program have been prepared by the
City which reduce any project-related impacts which may impact the public health, safety and
general welfare to a level of less than significant.
The approved site development, including site layout, structures, vehicular access, circulation and
parking, setbacks, height, walls, public safety and similar elements, has been designed to provide a
desirable environment for the development.
The subject site is physically suitable for the type and intensity of the approved development
because it is graded flat, has vehicular access and access to all public services.
Impacts to views are addressed because the project does not interrupt any views from I~580 and 1-
680.
G. Impacts to existing slopes and topographic features are addressed site is graded flat and.
Architectural considerations, including the character, scale and quality of the design, the
architectural relationship with the site and other buildings, building materials and colors, screening
of exterior appurtenances, exterior lighting, and similar elements have been incorporated into the
project and as conditions of approval in order to insure compatibility of this development with the
development's design concept or theme and the character of adjacent buildings, neighborhoods,
and uses.
Landscape considerations, including the location, type, size, color, texture and coverage of plant
materials, provisions and similar elements have been considered to ensure visual relief and an
attractive environment for the public.
2
BE IT FURTHER RESOLVED THAT THE City Council of the City of Dublin does hereby
approve the Site Development Review for PA 99~029, Home Depot EXPO Design Center, subject to the
following Conditions of Approval and subject to the approval of the Mitigated Negative Declaration and
Mitigation Monitoring Program:
CONDITIONS OF APPROVAL:
Unless stated otherwise, all Conditions of Approval shall be complied with prior to the issuance of
building permits or establishment of use, and shall be subject to Department of Community
Development review and approval. The following codes represent those departments/agencies
responsible for monitoring compliance of the conditions of approval: [ADM] Administration/Cky
Attorney, [B] Building division of the Community Development Department, [DSR] Dublin San
Ramon Services District, [F] Alameda County Fire Department/City of Dublin Fire Prevention, [FIN}
Finance Department, [PL] Planning division of the Community Development Department, [PO] Police,
[PW] Public Works Department.
~ CONDITION TEXT RESPON. WHEN HOW IS
.. AGENCY REQ'D CONDITION
Prior to: SATISFIED?
GENERAL CONDITIONS
1 Approval. This Site Development Review approval PL On-going Standard
for Home Depot EXPO Design Center, PA 99-029
establishes the detailed design concepts and
regulations for the project. Development pursuant to
this Site Development Review generally shall conform
the project plans submitted by Greenberg Farrow
Architects dated received November 15, 1999 and to
the colors and materials board received on November
15, 1999, on file in the Planning Department, and
other plans, text, and diagrams relating to this Site ..
Development Review, unless modified by the
Conditions of Approval contained herein. The project
facade will be redesigned to provide more
architectural detail, subject to review and approval of
the Community Development Director.
2 Public Art. Applicant/Developer shall install public PL See condition COA
art no later than two years after issuance of the
Certificate of Occupancy. The design and location of '
the art will be subject to review by the Arts and
Cultural Heritage Commission and approval by the
City Council. If the art is not installed prior to
occupancy, the Applicant/Developer will enter into an
agreement with the City to secure this requirement
will be performed within two years of the Certificate
of Occupancy.
3 Term. Approval of the Site Development Review PL Approval of Standard
shall be valid for one year from approval by the Improvement
Planning Commission. If construction has not Plans
commenced by that time, this approval shall be null
~ CONDITION TEXT RESPON. WHEN HOW IS
AGENCY REQ'D CONDITION
Prior to: SATISFIED?
and void. The approval period for Site Development
Review may be extended six (6) additional months by
the Director of Community Development upon
determination that the Conditions of Approval remain
adequate to assure that the above stated findings of
approval will continue to be met.
(Applicant/Developer must submit a written request
for the extension prior to the expiration date of the
Site Development ReView.)
4 Revocation. The SDR will be revocable for cause in PL On-going Municipal Code
accordance with Section 8.96.020.I of the Dublin
Zoning Ordinance. Any violation of the terms or .
conditions of this approval shall be subject to citation.
5 Ordinances/General Plan/Policies. The Developer PW, PL Issuance of Standard
shall comply with, meet, and/or perform all Building
requirements of the Subdivision Map Act, City of Permits
Dublin Subdivision Ordinance, City of Dublin Zoning
Ordinance, the City of Dublin General Plan, the
Eastern Dublin Specific Plan, City of Dublin Standard
Conditions of Approval, Public Works Policies and
City grading ordinance unless certain Public Works
requirements are modified by the Director 'of Public
Works.
6 Hold Harmless, The Applicant/DeveloPer shall hold PL, PW Ongoing Standard
the City harmless for all costs and expenses, including ' ~'
attorney's fees, incurred by the City or held to be the
liability of the City in connection with the City's
defense of its actions in any proceeding brought in any '
State or Federal court challenging the City's actions
with respect to the Applicant/Developer's project.
7 ADA Requirements/Handicap Ramps. All PW Completion of Standard
handicap ramps shall comply with all current State Improvements
ADA requirements and City of Dublin Standards.
8. Water Efficient Landscape Regulations. DSR, PW Approval of Standard
Applicant/Developer shall comply with all Improvement
implementation of the "Water Efficient Landscape Plans
Regulations of the Zoning Ordinance.
9. Standard Public Works Conditions of Approval. PW Approval of Standard
Applicant/Developer shall comply with all applicable Improvement
City of Dublin Standard Public Works Conditions of Plans through
Approval (Attachment A to this Resolution). In the . . completion
event of a conflict between the Standard Public WOrks
Conditions of Approval and these Conditions, these
conditions shall prevail:
4
~ CONDITION TEXT RESPON. WHEN HOW IS
AGENCY REQ'D CONDITION
Prior to: SATISFIED?
10. Fees. Applicant/Developer shall pay all applicable. Various Various times, Standard
fees in effect at time of building permit issuance. Said but no later
fees shall, include, but may not limited to, Planning than Issuance
fees, Building fees, Dublin San Ramon Services of Building
District fees, Public Facilities fees, Dublin Unified Permits
School District School Impact fees, Alameda County
Fire Services fees; Traffic Mitigation fees, Noise
Mitigation fees, Inclusionary Housing In-Lieu fees;
Alameda County Flood and Water Conservation
District (Zone 7). Drainage and Water Connection
fees; and Park In-Lieu fees. Fees are subject to
change without notice. Unissued building permits
subsequent to new or revised fees shall be subject to
recalculation and assessment of the share of the new
or revised fees.
~'1. Required Permits~ Applicant/Developer shall obtain Various Various times, Standard
all necessary permits required by other agencies but no later
(Alameda County Flood Control District Zone 7, than Issuance
California Department ofFish and Game, Army Corps of Building
of Engineers, State Water Quality Control Board, Permits
Etc.), and shall submit copies of said permits to the
Public Works Department.
12. Building Codes and Ordinances. All project B Through Standard
construction shall conform to the building codes and Completion
ordinances in effect at the time of building permit
issuance.
'~ 3"iRefuse Collection. 'The refuse collection service PL, PW Occupancy of Standard
provider shall be consulted to ensure adequate space is Any Building
provided to accommodate collection and sorting of
petrucible solid waste as well as source-separated
recyclable materials generated by the business.
14. Conditions of Approval. In submitting subsequent PW Issuance of Standard
plans for review and approval, Applicant/Developer Building
shall submit six ({5) sets of plans to the Public Works Permits
Department for plancheck. Each set of plans shall
have a copy of these Conditions of Approval attached.
with responses to each condition indicating where on
the plans and/or how the condition is satisfied. A
copy of the Standard Public Works Conditions of
Approval shall also be submitted which has been
marked-up to indicate where on the plans and/or how
the condition is satisfied. Notations shall clearly
indicate how all Conditions of Approval and Standard
Public Works Conditions of Approval will be
complied with. Improvement plans will not be
accepted without annotated conditions and standards
~ CONDITION TEXT RESPON. WHEN HOW IS
AGENCY REQ'D CONDITION
Prior to: SATISFH~D?
attached to each set of plans. Applicant/Developer will
be responsible for obtaining approvals of all
participatin~ non-City a~encies.
DEDICATIONS AND IMPROVEMENTS
15. Disabled Access Ramps. Disabled access ramps PW Completion of Standard
shall be provided at all intersection curb returns. All Improvements
disabled access ramps shall comply with current
California Building Code requirements and City of
Dublin Standards.
16. Drainage Study. Applicant/Developer shall prepare a PW Prior to PW
Drainage Study of the watershed area that is affected Issuance of
by this project to assure that the proposed drainage the Grading
improvements satisfy the design criteria published by Permit
Alameda County Public Works Agency. The drainage
study shall include a map showing tributary areas
(hydrology map), and hydraulic calculations
indicating quantity of flow and water surface elevation
at each node. All pipes shall flow at'2 feet-per-second
minimum velocity when the pipe is ~,5 full, and all
inlets shall maintain 1.25' freeboard as measured from
the top of curb to the hydraulic grade line for the 15-
year storm event. In addition, the building pad shall
be elevated at least 1.00' above the 100-year storm
event water surface elevation.
"17. Storm Drain Improvements. All on-site storm PW Approval of PW
- drainage improvements and flood mitigation measures Improvement . ~-
identified in the Drainage Study and/or required by the Plans
Public Works Director shall become requirements of
this project.
In no event shall storm water (sheet flow or pipe flow)
flow across the property lines onto a neighbor's
property unless allowed by the property's Conditions,
Covenants and Conditions, by a Private Storm Drain ~.
Easement, or by a Drainage Release is granted by the
neighbor.
The site design shall also incorporate an Emergency
Drainage Release to allow storm water to escape from
the site without flooding the buildings in the event the
storm pipes become plugged.
Any existing storm drain pipes to be abandoned shall
have both pipe ends securely closed with a tight-fitting
plug or wall of minor concrete in accordance with the
State of California Standard Specifications Section
15-2.05A.
6
~ CONDITION TEXT RESPON. WHEN HOW IS
AGENCY REQ'D CONDITION
Prior to: SATISFIED?
18. Site Clean up. The site shall be cleaned of all dirt, PW Completion of PW
trash, leaves, weeds, and other debris. The Applicant Improvements
shall also clean all on-site storm drain inlets and pipes
to prevent debris from discharging into the public
storm drain system.
19. Repair and Resurfacing of Parking Lot. The PW Completion of PW
Applicant/Developer shall repair all damaged parking Improvements
lot pavement and hardsurfaCing to the satisfaction of
the Public Works Director. Upon completion of all
repairs, the parking lot pavement on the project
property shown on the project plans shall be sealed
using an asphaltic emulsion (fog seal) or other
approved asphalt cOncrete sealant.
20. Replacement of Damaged Public Improvements. PW Completion of PW
The Applicant/Developer shall replace all damaged Improvements
improvements along the property frontage, within the
public right-of-way, including the curb, gutter,
sidewalk, driveway, paving (to street centerline), and
utilities as required by the Public Works Director. All
work shall be performed in accordance with the City's
standards, and may only be performed after the City
issues an Encroachment Permit.
21. Water Quality Requirements. All development PW Prior to PW
shall meet the water quality requirements of the City Issuance of
of Dublin's NPDES permit and the Alameda County the Grading
Urban Runoff Clean Water Program. The plans must . Permit
include a separate Erosion and Sediment Contro! plan
to be implemented during the rainy season (October
1~t to April 15th). Said plan shall conform to the latest
standards of the Regional Water Quality Control
Board. The site design shall also include some type of
permanent filtration system for all storm drain inlets
within the paved areas to prevent hydrocarbons and
other petroleum-based contaminants from entering the
public storm drain system. Installation details shall be
included on the plans. In addition, all storm water
inlets shall be stenciled "No Dumping - Flows to
Bay" using a standard stencil available from the
Alameda County Urban Runoff Clean Water Program,
located at 951 Turner Court, Hayward, California.
22. Rainwater Leaders. Rainwater leaders for the roof PW Approval of PW
drains shall be piped directly to the on-site storm drain Improvement
system. Plans
~ CONDITION TEXT RESPON. WHEN HOW IS
AGENCY REQ'D CONDITION
Prior to: SATISFIED?
23. Underground Utilities. All utilities for the new PW, PL Approval of PW, PL
building (i.e. electrical, telecommunications, cable Improvement
television, gas, etc.) shall be installed underground, Plans
unless approval is granted by the Director of
Community Development and the Public Works
Director.
24. Improvements within Existing Easements. The PW Approval of PW
Developer/Applicant shall investigate any existing Improvement
easements that may exist across the site. A Plans
Preliminary Title Report shall be submitted to indicate
the locations of any recorded easements affecting the
property, along with any record information required
during plan-check. Before the Public Works Director
approves plans for improvements within any existing
easements, the Developer/Applicant shall obtain a quit
claim or written permission from said easement
owner, and shall submit said documentation to the
Public Works Department.
TRAFFIC AND CIRCULATION
25. Traffic Mitigation Improvement Cost Contribution Issuance of
The Developer/Applicant shall contribute to the City's Building
Traffic Mitigation Improvement program in an Permit
amount equal to the number of anticipated weekday
trips generated by the project multiplied by a cost per
trip as determined by the Public Works Director. The
contribution amount equals $354,920.
~ CONDITION TEXT RESPON. WHEN HOW IS
AGENCY REQ'D CONDITION
Prior to: SATISFIED?
26. Internal Drive Aisle Improvements. Thc internal PW Approval of Mitigation
drive aisle that extends from the Dublin Boulevard / Improvement Measure No. 4
Golden Gate Drive intersection north to the proposed Plans and
Expo Center building, shall be improved to replace the During
"T" intersections with a smooth "S" curve. Said Construction
improvements shall be consistent with the
recommendations contained in the Consultant's
Report on the Transportation Impacts for the
Proposed Home Depot Expo Center dated September,
1999, prepared by Omni-Means Engineers and the
Director of Public Works.
Any new planter pockets and medians islands created
by the realignment shall be landscaped to the
satisfaction of the Public Works Director, the
Community Development Director, and the
neighboring property owner.
The Applicant/Developer shall notify and gain
apprqval from the neighboring property owner before
initiating any changes to the existing parking fields,
and shall coordinate all improvements such that
convenient and safe access to the existing buildings is
maintained during construction of the parking lot
improvements. At a minimum, a protected 6'-wide
pedestrian walkway shall be maintained between the
public sidewalk on Dublin Boulevard and the existing ' '
building occupied by Toys R Us and Montgomery
Wards, and between the aforementioned building and
the building occupied by the Lighthouse Bookstore,
Pretty N Plump, and Target.
27. Disabled Access. The site design shall include a PW Approval of PW
pedestrian walkway from the building's front or Improvement
primary entrance to the public sidewalk on Dublin Plans
Boulevard in conformance with the accessible route
requirements of the California Building Code. Said
route shall be separate from, and protected from
vehicle traffic in the parking lot.
28. Signing and Striping Plan. A signage and striping PW Approval of PW
plan for the parking lot shall be submitted to the Improvement
Public Works Department for review and approval. Plans
Said plan shall include dimensions of all drive aisles
I and parking stalls, along with detailed descriptions of
all signs to be installed. All striping shall be new at
the time of occupancy.
~ CONDITION TEXT RESPON. WHEN HOW IS
AGENCY REQ'D CONDITION
Prior to: SATISFIED?
ALAMEDA COUNTY - ZONE 7
29. Requirements and Fees. Applicant/Developer shall Zone 7, Issuance of Standard
comply with all Alameda County Flood Control and PW Building
Water Conservation District-Zone 7 Flood Control Permits
requirements and applicable fees.
30. Wells. Any water wells, cathodic protection wells or Zone 7, Issuance of Standard
exploratory borings shown on the site plan that are PW Grading
known to exist, are proposed, or are located during Permits
field operations without a documented intent of future
use filed with Zone 7, are to be closed prior to any
demolition or construction activity. Said closures
shall be in accordance with a well destruction permit
obtained from Zone 7 and the Alameda County
Department of Environmental Services. Wells
scheduled to remain shall be maintained in accordance
with applicable groundwater protection ordinances.
31. Line J-2. Zone 7 owns and maintains Line J-2 that is Zone 7, Issuance of Zone 7 letter
a 66-inch to 84-inch diameter buried RCP pipe. Zone PW Grading dated 7/16/99
7 has a 15-foot wide storm drain easement for this Permits
pipe, which runs along the south property line of this
project. Any work within this easement area including
hardscape/landscape improvements and/or
connections to the existing pipe must be performed in
accordance with an Encroachment Permit issued by
Alameda County. A licensed Professional Engineer
shall evaluate the capacity of the pipes to withstand ~.
the expected loading. The evaluation shall discuss the
proximity of the proposed structures, minimum
distances allowed to the proposed structures, live
loads, and earth and pavement surcharge loads. The
building's foundation shall be carefully designed to
avoid exerting forces that may over-stress the
structural integrity of the existing pipe.
32. Storm drain easement. The existing Zone 7 15-foot Zone 7, Issuance of Zone 7 letter
wide storm drain easement shall be drawn and clearly PW Grading dated 7/16/99
labeled on a revised Site Plan. This Site Plan shall Permits
also label the existing and proposed facilities,
proposed landscaping, manholes, and all other
relevant items that may fall within/near this easement.
10
~ CONDITION TEXT RESPON. WHEN HOW IS
AGENCY REQ'D CONDITION
Prior to: SATISFIED?
DUBLIN SAN RAMON SERVICES DISTRICT (DSRSD)
33. General Conditions
a. Complete improvement plans shall be submitted to DSRSD Issuance of DSRSD
that conform to the requirements of the DSRSD Code, the Building 5/10/2000
DSRSD "Standard Procedures, Specifications and Drawings Permits
for Design and Installation of Water and Wastewater
Facilities," all applicable DSRSD Master Plans and policies,
and all Recycled Water Design and Construction Standards.
b. All mains shall be sized to provide sufficient capacity to Issuance of DSRSD
accommodate future flow demands in addition to each Building 5/10/2000
development project's demand. Layout and sizing of mains Permits
shall be in conformance with DSRSD utility m~ster
planning.
c. Sewers shall be designed to operate by gravi/~y flow to Approval of DSRSD
DSRSD's existing sanitary sewer system. Pumping of Improvement 5/10/2000
sewage is discouraged and may only be allowed under Plans
extreme circumstances following a case by case review with
DSRSD staff. Any pumping station will require specific
review and approval by DSRSD of preliminary design
repons, design criteria, and final plans and specifications.
The DSRSD reserves the right to require payment of present
value 20'-year maintenance costs as well as other conditions
within a separate agreement with Applicant/Developer for
any project that requires a pumping station.
d. Domestic and fire protection waterline syStems for Approval of DSRSD
residential tracts or commercial developments shall be .... Improvement 5/,10/2000
designed to be looped or interconnected to avoid dead-end Plans
sections in accordance with requirements of the DSRSD
Standard Specifications and sound engineering practices.
e. DSRSD policy requires public water and sewer lines to be Approval of DSRSD
located in public streets rather than in off-street locations to Improvement 5/10/2000
the fullest extent possible. If unavoidable, public sewer or Plans
water easements must be established over the alignment of
each public sewer or water line in an off-street or private
street location to provide access for future maintenance
and/or replacement.
f. The locations and widths of all proposed'easement Issuance of DSRSD
dedications for Water and sewer lines shall be submitted to Grading 5/10/2000
and approved by DSRSD. Permit
g. All easement dedications for DSRSD facilities shall be by Approval of DSRSD
separate instrument irrevocably offered to DSRSD or by Final Map 5/10/2000
offer of dedication on the Final Map.
h. All utility connection fees, plan-checking fees, inspection Issuance of DSRSD
fees, permit fees, and fees associated with a wastewater Building 5/10/2000
discharge permit shall be paid to DSRSD in accordance with Permits
the rates and schedules established in the DSRSD Code.
11
~ CONDITION TEXT RESPON. WHEN HOW IS
AGENCY REQ'D CONDITION
Prior to: SATISFIED?
i. All improvement plans for DSRSD facilities shall bc signed Issuance of DSRSD
by the District Engineer. Each drawing of improvement Building 5/10/2000
plans shall contain a signature block for the District Engineer Permits
indicating approval of the sanitary sewer or water facilities
shown. Prior to approval by th~ District Engineer,
Applicant/Developer shall pay all required DSRSD fees, and
provide an engineer's estimate of construction costs for the
sewer and water systems, a performance bond, a one-year
maintenance bond, and a comprehensive general liability
insurance policy in the amounts and forms that are
acceptable to DSRSD. Applicant/Developer shall allow at
least 15 working days for final improvement drawing review
by DSRSD before signature by the District Engineer.
j. No sewer line or water line construction shall be permitted Issuance of DSRSD
unless the proper utility construction permit has been issued Building 5/t 0/2000
by DSRSD. A construction permit will only be issued after Permits and
all of the DSRSD conditions herein have been satisfied, all DSRSD
requirements
k. The Applicant/Developer shall hold DSRSD, its Board of On-going DSRSD
Directors, commissions, employees, and agents of DSRSD 5/10/2000
harmless and indemnify the same from any litigation, claims,
or fines resulting from completion of the project.
1. The project is located within the District Recycled Water Completion of DSRSD
Use Zone (Ord. 280), which calls for installation of recycled Improvements 5/10/2000
water irrigation systems to allow for the future use of
recycled Water for approved landscape irrigation demands.
Recycled water will be available in the future. Unless
specifically exempted by the District Engineer, compliance
with Ordinance 280, as may be amended or superseded, is
required. All irrigation facilities shall be subject to review
for compliance with District and Department of Health
Services Requirements for recycled water irrigation design.
EMERGENCY SERVICES
ALAMEDA COUNTY FIRE DEPARTMENT (ACFD)
34. Emergency Access and Water Supply. Emergency F Prior to UTC 1994, Sec
Access and water supply shall be installed prior to combustible 1001.4
combustible storage on site or vertical construction, storage or
Access shall be maintained during construction, vertical
Acceptance is based on access plan approval by Fire construction
Prevention and field acceptance by the Department of
Public Works.
35. Fire hydrants and fire flow. Fire hydrants and fire F Building
flow shall be sufficient to meet the minimum permit
requirements for this project.
12
~ CONDITION TEXT RESPON. WHEN HOW IS
AGENCY REQ'D CONDITION
Prior to: SATISFIED?
36. Fire apparatus roadways. Fire apparatus roadways F Building UFC 1994, Sec
must have a minimum unobstructed width of 20 feet permit 902.2.2.1
and an unobstructed vertical clearance of not less than
13 feet 6 inches. Roadways under 36 feet wide shall
be posted with signs and shall have red curbs painted
with labels on one side; roadways under 28 feet wide
shall be posted with signs and shall have red curbs
painted with labels on both sides of the street as
follows: ~%10 STOPPING FIRE LANE - CVC
22500.1". The fire lane shall be recorded as an
Emergency Vehicular Access Easement.
37. Sprinkler system. An approved automatic fire F Building
sprinkler system shall be installed ~hroughout. Permit
38. Sprinkler system monitoring. Sprinkler systems F. Building UFG 1994, Sec
serving more than 100 heads shall be monitored by an Permit 1003.3
approved central station, U.L. listed and certificated
for fire alarm monitoring. A copy of the U.L. listing
must be provided to the Alameda County Fire
Department, City of Dublin, Fire Prevention Division,
prior to scheduling the final test system.
39. Fire Extinguishers. Provide at least one 2A 10BC F Building [IFC 1994, Sec
portable fire extinguisher for each 6000 square feet of Permit 1002.1
floor area. Travel distance to an extinguisher shall not
exceed 75 feet of travel distance and shall not be
between floors.
40. Addresses. Approved numbers or addresSes shall be F - Occupancy UFC 1994, Sec
placed on all new and existing buildings. The address .... 901.4.4
shall be positioned as to be plainly visible and legible
from the street or road fronting the property. Said
numbers shall contrast with their background.
41. Furniture/Equipment Layout. Submit F Building UFC 1994, Sec
furniture/equipment layout showing adequate aisles to Permit 1204.2.1
exit.
42. Knox Box. A Knox Box key lock system is required F Occupancy _. UFC 1994, Sec
for the building. 10.203
POLICE
43. Non-residential Security. The project shall comply PL, B, P Occupancy of Standard
with the City of Dublin Non-residential Security Units
Requirements.
44. Security view ports. All man doors shall be provided PL, P Occupancy of Standard
with security view ports to prevent unauthorized entry. Units
45. Addressing and building numbers. Addressing and PL, B, P Occupancy of Standard
building numbers shall be visible from the approaches Units
to the building. Rear exist doors shall display the
business name and address in three inch high lettering.
13
~ CONDITION TEXT RESPON. WHEN HOW IS
AGENCY REQ'D CONDITION
Prior to: SATISFIED?
46. Final Lighting Plan. The applicant shall submit a PL, B, P Occupancy of Standard
Final Lighting Plan for approval by the Dublin Police Units
and the Director of Public Works. Exterior lighting
shall be provided within the parking lot, around the
entire perimeter of the building, and over exterior
doors, and shall be of a design and placement so as not
to cause glare onto adjoining properties, businesses or
to vehicular traffic. Lighting used after daylight hours
shall be adequate to provide for security needs (One
foot candle). Wall lighting around the perimeters of
the building should be supplied to provide "wash"
security lighting as appropriate.
47. Exterior landscaping. Exterior landscaping shall'be PL, P Occupancy of Standard
kept at a minimal height and fullness giving patrol Units
officers and the general public surveillance
capabilities of the area.
48. Theft prevention and security program. The PL, P Ongoing Standard
applicant shall work with the Dublin Police on an
ongoing basis to establish an effective theft prevention
and security system.
49. Graffiti. The Developer shall keep the site clear of PL, P Ongoing Standard
graffiti vandalism on a regular and continuous basis at
all times. Graffiti-resistant materials and foliage
should be used.
50. Gates on walkway on north side of building: The PL, P Prior to' Mitigation
Applicant shall install gates, designed and · , occupancy or Measure No. 3
constructed to the satisfaction of the Dublin Police use' of the
Services, preventing access into the gap between the project
project and the Target store to the north. The gates
shall have panic hardware installed on the inside that
cannot be accessed from the outside to facilitate
emergency escape from the area between the project
and the Target store.
HAZARDOUS MATERIALS
51. Contaminated soil warning: Prior to issuance of a PL, PW Prior to Environmental
grading permit for the project the applicant shall Grading Site Assessment
notify contractors building the proposed Home Depot Permit and Mitigation
EXPO Design Center to be alert to the potential of area Measure No. 2
encountering contaminated soil during grading
operations and to notify SGI if any suspect material is
found.
Trash Enclosures
52. Trash Bin Enclosures. All trash bin enclosures shall PL, PW, Building Standard
be 10 feet by 12 feet in size for a single bin and 10 by LDD Permit
18 feet in size for two bins. Bins shall not be larger
than 4 yards in capacity. A 10-foot deep .conc?ete .
14
~ CONDITION TEXT RESPON. WHEN HOW IS
AGENCY REQ'D CONDITION
Prior to: SATISFIED?
apron shall be installed in front of the entire width of
the enclosure. The enclosure shall have a 6-inch by 6-
inch curb on the inside of the enclosure wall to protect
the walls of the enclosure from the bins. The
enclosure shall be built of concrete block or equivalent
and shall have metal doors. Chain link doors are not
permitted. The doors must be designed so that they
can be locked closed and can also be held open with
pin locks during loading. Trash bin enclosures shall
be finished so that they are architecturally compatible
with the related main structure. Trash bin enclosures
shall be properly maintained and free of graffiti. All
trash bins used for this site shall be located within the
-- trash bin enclosure(s) at all times unless being
emptied. The container shall be covered and shall
meet the requirements of the County Health Code, the
Dublin San Ramon Services District and the National
Pollution Discharge Elimination System.
The final location of trash enclosures shall be
determined prior to submittal of building plans to the
review and approval of the City Planning Department,
Public Works Department and the Livermore Dublin
Disposal Service.
53. Trash enclosures for adjacent land uses. The PL Bu. ilding Standard
Developer shall work with the appropriate Dublin Permit
Place Shopping Center management authority to
ensure that trash enclosures are provided for the
Lighthouse Bookstore and other tenants of the
structure between the project and the Target store.
ARCHAEOLOGY
54. Archaeology - Should any prehistoric or historic PL, PW, B Final Mitigation
artifacts be exposed during excavation and Inspection of Measure No. 1 --
construction operations, the Department of Grading
Community Development shall be notified and work
shall cease immediately until an archaeologist, who is
certified by the Society of California Archaeology
(SCA) or the Society of Professional Archaeology
(SOPA), is consulted to evaluate the significance of
the find and suggest appropriate mitigation measures,
if deemed necessary, prior to resuming ground
breaking construction activities. Standardized
procedures for e-~aluating accidental finds and
discovery of human remains shall be followed as
prescribed in Sections 15064.5 and 15126,4 of the
California Environmental Quality Act Guidelines.
15
~ CONDITION TEXT RESPON. WHEN HOW IS
AGENCY REQ'D CONDITION
Prior to: SATISFIED?
ARCHITECTURE
55. The structure shall comply with the architectural PL Occupancy Standard
drawings submitted by Greenberg Farrow Architecture
dated received November 15, 1999, and shall
generally conform to the colors and materials book
dated received November 15, 1999, on file in the City
of Dublin Department of Community DevelopmenL
LANDSCAPING
"56. Final Landscaping and Irrigation Plan. PL, PW Issuance of COA
Applicant/DeveloPer shall submit a Final Landscaping Building
and Irrigation Plan, conforming to the requirements of Permits
Section 8.72.030 of the Zoning Ordinance (unless
otherwise modified by Conditions of this ReSolution),
stamped and approved by the Director of Public
Works and the Director of Community Development:
Alameda County Fire Department approval is also
required where this project is adjacent to wildfire
areas. That plan should generally conform to the
Preliminary .Landscape Plans dated received
November 15, 1999.
57. Final Landscape Plan Review. The plant palette PL Issuance of COA
varieties shall be shall be sUbject to review and Building
approval of the Director of Community Development Permits
and reviewed by the City's Landscape Architect to
determine compatibility with reclaimed water use,
where appropriate. An irrigation Plan shall be ....
submitted with Final Landscape Plans indicating that
the system is designed for reclaimed water, where
required by DSRSD.
58. Conflicts with Proposed Landscape Features. The PL, PW Approval of Standard
final landscape and irrigation plans shall show Imp. Plans/
locations of all pedestrian lighting, utilities, drainage Issuance of
ditches, and underdrains at bottom of slopes. Plans Building
shall address tree planting within public service Permits
easements to avoid conflicts with utilities and
streetlights.
59. Standard Plant Material, Irrigation and PL, PW Issuance of Standard
Maintenance Agreement. The Applicant/Developer Building
shall complete and submit to the Dublin Planning Permits
Department the Standard Plant Material, Irrigation and
Maintenance Agreement.
60. Backflow Devises. Backflow devises shall be hidden PL Issuance of Standard
from view by means of fencing, enclosures, Grading
landscaping and/or berms. Permits
16
~ CONDITION TEXT RESPON. WHEN HOW IS
AGENCY REQ'D CONDITION
Prior to: SATISFIED?
61. Water Efficient Landscape Regulations. PL, PW, Approval of Standard
Applicant/Developer shall ensure that the Final DSR Final
Landscaping and Irrigation Plan conforms to the City's Landscape
Water Efficient Landscape Regulations, including Plans
dual piping to facilitate future recycled water.
62. Lighting. Lighting in landscaped and hardscaped PL, PW Approval of Standard
areas throughout the site shall be subject to the review Imp. Plans/
and approval of City's Landscape Architect, Planning, Issuance of
and Public Works Departments, in consideration of Building
IES standards for lighting in public/community areas. Permits
A photometric plot shall be prepared to show the
lighting intensity at all exterior areas of the site.
Additional lighting shall be installed if the light levels
at the ground surface fail to meet the standards set
forth in the City's Security Ordinance.
63. Fire-Resistant and/or Drought Tolerant Plant PL, PW Approval of Standard
Varieties. Final landscaping and irrigation plans shall Imp. Plans/
include fire-resistant and/or drought tolerant plant Issuance of
varieties in the plant palette. Building
Permits
64. Bicycle Parking. The Applicant/Developer shall PL, PW Completion of Standard
install one bike rack designed to hold up to six Improvements
bicycles. The location of the bike rack shall not
encroach into any walkway area in a manner that
would reduce the useable width of the walkway to less
than 4'. The rack shall be located in a place with good
visibility from both inside and outside of the building,
and in an area which will be well lighted to discourage
theft.
65. Landscaping. All landscaping including all trees, PL Occupancy Standard
shrubs and planting for the arbors and hardscape shall
be installed prior to the occupancy or use of the
building. All improvements shall be to the satisfaction
of the Director of Public Works.
66. Number not used
67. Slopes in Landscaping Areas. The slope within
landscaping areas shall not exceed 4 horizontal to 1
vertical (4:1).
68. Landscaping at Aisle Intersections. Landscaping at PL, PW Completion of Standard
aisle intersections and at the driyeway entrances shall Improvements
be such that vehicle sight distance as defined by the
City of Dublin standards is not obstructed. Except for
canopy trees, landscaping shall not grow to a height in
excess of 30 inches above the curb in these areas.
17
~ CONDITION TEXT RESPON. WHEN HOW IS
AGENCY REQ'D CONDITION
Prior to: SATISFIED?
STANDARDS ......
69. Health, Design and Safety Standards. Prior to final PL, PW Occupancy of Standard
approval allowing occupancy of the building, the Unit
physical condition of the site shall meet minimum
health, design, and safety standards including, but not
limited to the following:
a. The drive aisles and parking stalls shall be PL, PW Occupancy of Standard
complete, and free of building materials, dirt, Unit
and/or debris to allow for safe traffic
movements.
b. All traffic striping and control signing in the PW Occupancy of Standard
parking lot shall be repainted or installed to the Unit
satisfaction of the Public Works Director.
c. All new and existing parking lot lights shall be PW Occupancy of Standard
energized and functional. Unit
d. Any required repairs to the street, curb, gutter, PW Occupancy of Standard
and/or sidewalk that may create a hazard shall Unit
be completed to the satisfaction of the Public
Works Director.
e. All sewer clean-outs, water meter boxes, and PW Occupancy of Standard
other utility boxes shall be set to grade, and Unit
appropriate covers shall be installed.
f. The building shall have Building Department PW, B Occupancy of Standard
final approval for occupancy. Unit
MISCELLANEOUS CONDITIONS
70. Parkland Dedication - The developer shall be PL Building Standard
"' required to pay a Public Facilities Fee in the amounts Permit
and at the times set forth in City of Dublin Resolution
No. 32-96, adopted by the City Council on March 26,
1996, or in the amounts and at the times set forth in
any resolution revising the amount of the Public
Facilities Fee. No credit against the dedication
requirement shall be given for open space within this
project.
71. Compliance With Requirements. F, PW, Approval of Standard
Applicant/Developer shall comply with all applicable PO, Zone Improvement
requirements of the Alameda County Fire Department, 7, DSR, Plans
Public Works Department, Dublin Police Service, PL
Alameda County Flood Control District Zone 7, and
Dublin San Ramon Services District.
72. Building Permits. To apply for building permits, B Issuance of Standard
Applicant/Developer shall submit thirteen (13) sets of Building
construction plans to the Building Department for plan Permits
check. Each set of plans shall have attached a copy of
these Conditions of Approval with the "How is
Condition Satisfied?" column filled out. The notations
18
~ CONDITION TEXT RESPON. WHEN HOW IS
AGENCY REQ'D CONDITION
Prior to: SATISFIED?
shall clearly indicate how all Conditions of Appr°val
will or have been complied with. Construction plans
will not be accepted without the annotated resolutions
attached to each set of plans. Applicant/Developer
will be responsible for obtaining the approvals of all
participating non-City agencies prior to issuance of
building permits.
73. Containment of Trash & Debris. Measures shall be PW During Public Works
taken to contain all eonstruction~related trash, debris, Construction Director Lee
and materials on-site until proper disposal can be Thompson
arranged. The Applicant/Developer shall keep the
adjoining public streets and sidewalk area clean and
free of dirt, debris, and materials at all times during the
construction period. All costs associated with the
City's efforts to mitigate a hazard as a result of the
Applicant's/Developer's failure to comply shall be
borne by the Applicant/Developer.
74. Temporary Construction Fencing. The use of PW, B During Public Works
temporary construction fencing shall be installed to Construction Director Lee
safeguard the public during construction of the new Thompson
building and site improvements. Said fencing shall be
subject to the review and approval of the Public Works
Director and the Building Official.
75. Aboveground Utility Screening. All above-ground PL, PW Approval of Standard
utilities that cannot be placed underground (i.e. Improvement
backflow prevention devices, electrical transformers) Plans
shall be screened using landscaping or an architectural ~.
feature acceptable to the Director of Community
Development and Public Works Director.
ENERGY CONSERVATION
76. Energy Conservation. Building plans shall PL, PW Issuance of Standard
demonstrate the incorporation of energy conservation Building
measures into the design, construction, and operation Permits
of the proposed development:
PASSED, APPROVED AND ADOPTED this 6th day of June, 2000.
AYES: Councilmembers Howard, McCormick, Zika, Vice Mayor Lockhart and Mayor
Houston
NOES: None
ABSTAIN: None
v ct Mayor
ATTEST: ~1~ .~~~. ,~ ~-~
K2/G/6-6-OO/rem-~-'-~dr?~'-C~?evige,,fl. dColce~lktem 6.1)
g:99029\ccsdrreso
19