HomeMy WebLinkAboutReso 122-19 Approving Findings Regarding the Need for Local Amendments to Provisions in the California Building Standards CodeRESOLUTION NO. 122 -19
A RESOLUTION OF THE CITY COUNCIL
OF THE CITY OF DUBLIN
APPROVING FINDINGS REGARDING THE NEED FOR LOCAL AMENDMENTS TO
PROVISIONS IN THE CALIFORNIA BUILDING STANDARDS CODE AS ADOPTED BY THE
STATE OF CALIFORNIA, IN THE CALIFORNIA CODE OF REGULATIONS, TITLE 24, TO BE
ADOPTED BY REFERENCE IN THE DUBLIN MUNICIPAL CODE
WHEREAS, Health and Safety Code Section 18938 makes provisions published in the
California Building Standards Code pursuant to Health and Safety Code Section 17922 applicable
to all occupancies throughout the State and effective one hundred and eighty days after
publication by the California Building Standards Commission (the "Commission"), or at a later date
established by the Commission; and
WHEREAS, California Health and Safety Code Sections 17958, 17958.5, 17958.7 and
18941.5 establish the authority for a city to adopt and make local amendments and modifications
to the building standards in the California Building Standards Code to establish more restrictive
building standards than those contained in the California Building Standards Code; and
WHEREAS, California Health and Safety Code Sections 17958, 17958.5, 17958.7 and
18941.5 permit a city to make such local amendments and modifications as the city determines
are reasonably necessary because of local climatic, geological or topographical conditions; and
WHEREAS, California Health and Safety Code Sections 17958, 17958.5, 17958.7 and
18941.0 require a city, before making any amendments and modifications to the California
Building Standards Code, make an express finding that such amendments and modifications are
reasonably necessary because of local climatic, geological or topographical conditions.
WHEREAS, under Health and Safety Code Section 17958.7, changes pursuant to Health
and Safety Code Section 17958.5 may not become effective until the required findings, and the
changes, have been filed with the California Building Standards Commission; and
WHEREAS, Government Code Section 50022.2 permits enactment of City Ordinances
that adopt codes or statutes, including codes of the State of California, by reference; and
WHEREAS, notice of the Ordinance was published in accordance with Government Code
Sections 50022.3 and 6066; and that such notice was sufficient to give notice to interested
persons of the purpose of the ordinance and the subject matter thereof; and
WHEREAS, the City Council of the City of Dublin intends to adopt an Ordinance adopting
by reference provisions of the California Building Standards Code, with local amendments; and
WHEREAS, the City Council has reviewed the reasons for proposed changes to the
California Building Standards Code set forth in Exhibit A, attached hereto and hereinafter
incorporated by reference.
NOW, THEREFORE, BE IT RESOLVED that the City Council does hereby declare and
find that the local amendments to the provisions of the California Building Standards Code set
forth in Exhibit A are reasonably necessary because of local climatic, geologic, or topographical
conditions in accordance with Health and Safety Code Section 17958.7 as further set forth in
Exhibit A; and
BE IT FURTHER RESOLVED that a copy of this Resolution, including Exhibit A, shall be
filed with the California Building Standards Commission in accordance with Health and Safety
Code Section 17958.7.
vote:
PASSED, APPROVED AND ADOPTED thisday of November, 2019, by the following
AYES:
NOES
ABSENT:
ABSTAIN:
ATTEST:
City Clerk
Councilmembers Goel, Hernandez, Josey, Kumagai and Mayor Haubert
None
None
None
Mayor
Reso No. 122-19, Adopted 11/19/19, Item No. 6.1 Page 2 of 2
FINDINGS FOR LOCAL AMENDMENTS TO THE 2019 EDITIONS OF THE
CALIFORNIA FIRE CODE, CALIFORNIA BUILDING CODE, CALIFORNIA RESIDENTIAL
CODE, CALIFORNIA ELECTRICAL CODE, CALIFORNIA PLUMBING CODE, CALIFORNIA
MECHANICAL CODE, AND CALIFORNIA GREEN BUILDING CODE
AS SET FORTH IN THE 2019 CALIFORNIA BUILDING STANDARDS CODE
A. General Findings. The Dublin City Council makes the following general findings regarding
local climatic, geologic, and topographical conditions, which the City Council finds
necessitates the local modifications to the California Building Standards Code set forth
below:
1. Local climatic conditions include a low amount of average yearly rainfall, which tends to
be concentrated from October through April. From May through September, a dry period
occurs where daily temperatures remain high and there is little measurable precipitation.
In addition, the local climate frequently includes high winds which sweep down through
the valley. As a result of the high summer temperatures, average load demand and peak
load demand of energy used in Dublin are important factors impacting public safety and
creating the potential for adverse economic impacts due to power outages or power
reductions (i.e. "brownouts"). As a result of the low precipitation, the area is subject to
occasional drought.
In developed areas of the City, fires can occur in buildings, rubbish, automobiles, and
grass fires on vacant lots. In the undeveloped areas of the City, there is a risk of large
brush and grass fires. If a fire occurs in either a developed or undeveloped area of the
City, the local dry conditions combined with high winds, creates the risk of a potential fire
storm.
In addition, local residential development is occurring in previously undeveloped areas
adjacent to wild fire hazard areas. These new developments increase the chance of fire
while simultaneously being located further from fire stations, delaying critical response
times. This potential problem can be mitigated by requiring initial fire control through the
installation of automatic fire protection systems.
2. Local geologic conditions include a risk of earthquake. A number of earthquake faults
are located either within or in close proximity to the City. Those with the most direct and
potentially destructive impact are the San Andreas, Calaveras, Hayward, Greenville and
Concord -Green Valley Faults. History of earthquake activity indicates that there is a
likelihood of a major earthquake in the area. The largest recorded earthquake in this
immediate area occurred on the San Andreas Fault on October 17, 1989, a 7.1
magnitude. This area had a sequence of earthquakes on the Greenville Fault in January
and February of 1980; these earthquakes had a magnitude of 5.5 to 5.9 on the Richter
Scale and in July 2019 the Greenville Fault had an earthquake of 4.3. The U.S.
Geological Survey (USGS) has identified a 72% probability of a major (6.7 or larger)
earthquake occurring in the region within the next 30 years (Source — USGS UCERF3
report). Recent earthquake damage studies, including the 1994 Northridge earthquake,
have indicated the lack of adequate design and detailing as a contributing factor to
damages that reduced the protection of the life -safety of building occupants.
Page I of 45 EXHIBIT A
In the event of an earthquake, damage to structures can be expected. In residential and
commercial areas, this could include significant damage or collapse of buildings.
Secondary impacts could include ruptured electric or gas connections and/or breaks in
water distribution lines. The potential for a major seismic event would create a City-wide
demand for emergency response and fire protection service which would exceed staff
response capacity. This potential problem can be mitigated by requiring initial fire control
through the installation of automatic fire protection systems.
3. Local topographical conons include hills on the western and eastern boarders and flat
area in the center of the City. Interstate 680 divides the City into two sections, and
circulation between areas of the City rely on freeway overpasses. In addition, local traffic
must also pass over railroad tracks, creeks, and bridges (to cross arroyos).
During peak a.m. and p.m. traffic periods, the City experiences heavy traffic congestion at
key intersections, and near many freeway on -ramp and off -ramps. In the event of an
accident or emergency at one of these key intersections, bridges, or other circulation
corridors, sections of the City could become isolated and response times increased
beyond ideal levels. Again, this potential problem can be mitigated by requiring initial fire
control through the installation of automatic fire protection systems.
4. Based on the local climatic, geologic, and topographical conditions outlined above, there
is a real risk that emergency response could be significantly delayed in the event of an
accident or emergency. Therefore, it is necessary to address this problem through the
requirement of additional mitigation measures to: (i) prevent the chance of accident or
injury by requiring standards more stringent than required by the current codes; and (ii)
requiring additional built-in automatic fire protection systems which will provide for early
detection and initial fire control.
B. Specific Findings: The Dublin City Council makes the following specific findings, which, in
addition to the general findings regarding local climatic, geologic, and topographical
conditions set forth above, the City Council finds necessitate the local modifications to the
California Building Standards Code set forth below:
Page 2 of 45
1. California Fire Code.
5.08.110 Chapter 2 DeTinitions-Amended.
Chapter 2 is amended by adding the following definitions to Section 202:
Section 202 General Definitions.
City Council shall mean the governing body of the City of Dublin.
City Manager shall mean the City Manager of the City of Dublin or his or her designee.
Fire Trail means a graded firebreak of sufficient width, surface, and design to provide
access for personnel and equipment to suppress and to assist in preventing a surface
extension of fires.
Fuel break means a wide strip or block of land on which the vegetation has been
permanently modified to a low volume fuel type so that fires burning into it can be more
readily controlled.
FINDING: These modifications are necessary to adopt the most current State standard
and to clarify specific areas of the code. In addition, these modifications will
make Chapter 6.08 consistent with Chapters 7.28, 7.32 and 7.34 of the Dublin
Municipal code. Definitions clarify the title of Fire Chief and City Council as
specific to the City of Dublin. These modifications will provide guidelines
for Fire Department access Jocations and roadway preparation. The
modifications also provide specific language to insure adequate access to
fire hydrants and fire appliances.
5.08.120 Table 315.7.6(1), Separation Distance Between Wood Pallet Stacks and
Buildings. — Amended
Table 315.7.6(1) is amended to read:
WOOD PALLET SEPARATION DISTANCE
feet
<_ 50
51 to 200
>200
WALL
CONSTRUCTION
OPENING TYPE
Pallets
Pallets
Pallets
Masonry
None
2
2
2
Masonry
Fire -rated glazing with open
2
5
20
sprinklers
Masonry
Fire -rated glazing
5
10
20
Masonry
Plain glass with open Sprinklers
5
10
20
Noncombustible
None
5
10
20
Wood with open
_
5
10
20
sprinklers
Wood
None
15
30
90
Any
Plain Glass
15
30
90
Fore SI: 1 foot = 304.8 mm.
FINDING: The amendment is needed due to local climatic and topographical
conditions.
Page 3 of 45
This modification was necessary because the City of Dublin has a dry
period of at least five months each year. Additionally, the area is subject to
occasional drought. Because of dryness, a rapidly burning grass fire,
exterior building or pallet fire can quickly transfer to other buildings,
structures or pallet stacks. These modifications are consistent with the Fire
Authority having jurisdiction. In addition, these modifications correct an
error in the model code.
5.08.130 Section 503.2.9 Specifications -Added.
Section 503.2.3.1 is added to read as follows:
503.2.9 Fire and Emergency Access Roads approved for construction sites shall be
designed to meet the requirements of Section 503.2. The access shall be approved by
the Fire Department prior to commencement of combustible storage or vertical
combustible construction on the site.
FINDING: This modification is necessary to adopt the most current State standard and
to clarify specific areas of the code. In addition, these modifications will
make Chapter 5.08 consistent with Chapters 7.28, 7.32 and 7.34 of the Dublin
Municipal code. This modifications will provide guidelines for Fire
Department access locations and roadway preparation. The modifications
also provide specific lanquage to insure adequate access to fire hydrants
and fire appliances.
5.08.140 Sections 903.2.4.1, 903.2.9.1, 903.2.9.2, 903.2.10 903.2.10.1-Deleted; Sections
903.2.1.1#1, 903.2.1.2#1, 903.2.1.3#19 903.2.1.4#19 903.2.3#11 903.2A,
903.2.7#19 903.2.9, 903.2.11.3-Amended; and Sections 903.2.2.1 and 903.2.30-
Added.
Sections 903.2.4.1, 903826901, 903220902, 903.2.10 and 903.2.10.1 are deleted, Sections
903626101#11 903.2.1.2#11 903026103#11 903929104#11 9030203#11 9030204, 903.2.7#11 9030209,
and 903.2.11.3, are amended to read as follows, and Sections 903.2.2.1, and 903.2.30 are
added to read as follows:
903.2.1.1 Group A-1 Occupancies.
1. Where the floor area exceeds 3,000 square feet (279 m2).
903.2.1.2 Group A-2 Occupancies.
1. Where the floor area exceeds 3,000 square feet (279 m2).
903.2.1.3 Group A-3 Occupancies,
1. Where the floor area exceeds 3,000 square feet (279 m2).
903.2.1.4 Group A4 Occupancies.
1. Where the floor area exceeds 3,000 square feet (279 m2).
903.2.2.1 Group B Occupancies.
An automatic fire -extinguishing system shall be installed in Group B occupancies where
the floor area exceeds 3,000 square feet (279 m2).
903.2.3 Group E Occupancies.
Page 4 of 45
1. An automatic fire -sprinkler system shall be in Group E, occupancies where the floor
area exceeds 3,000 square feet (279 m2).
903.2.4 Group F Occupancies.
An automatic fire sprinkler system shall be installed in all Group F occupancies where the
floor area exceeds 2,500 square feet (232 m2).
(Section 903.2.4.1 is deleted)
903.2.7 Group M Occupancies.
1. An automatic sprinkler system shall be installed in Group M occupancies where the
floor area exceeds 2,500 square feet (232 m2).
903.2.9 Group S Occupancies.
An automatic sprinkler system shall be installed in all Group S occupancies as follows:
1. Where the floor area exceeds 2,500 square feet (232 m2);
2. Buildings with repair garages servicing vehicles parked in basements.
(Sections 903.2.4.1, 903.2.9.1, 903.2.9.2, 903.2.10, 903.2.10.1 are Deleted)
903.2.11.3 Buildings Three Or More Stories in Height.
An automatic sprinkler system shall be installed in all occupancies, regardless of type of
construction, if the building is three or more stories or more than 35 feet in height
measured from the pad grade level to the highest point of the building. An automatic
sprinkler system shall be installed in all other occupancies as may be required by the
2019 California Building and Residential Code.
903.2.30 All Occupancies
An automatic fire -extinguishing system shall be installed in all occupancies located more
than one and a half (1'/2) miles from a fire station providing fire protection to that location.
Said distance shall be measured in a straight line.
Buildings containing portions which are required to have an automatic fire extinguishing
system because of the number of stories shall have the automatic fire extinguishing
system installed throughout and fire walls as set forth in Section 706 shall not be
considered as creating separate buildings for the purpose of this section.
Whenever an addition is made to an existing building, automatic fire -extinguishing
systems shall be installed if the existing building plus the addition exceeds the area or
height limitations set forth in this section. Whenever the use of an existing building or
portion thereof is changed in any manner so as to require the installation of an automatic
fire -extinguishing system, said system shall be installed in that portion of the building
housing the new use.
FINDING: The amendment is needed due to local climatic and topographical
conditions.
These modifications are necessary because the City of Dublin has a dry
period of at least five months each year. Additionally, The area is subject to
Page 5 of 45
occasional drought. Because of dryness, a rapidly burning grass fire or
exterior building fire can quickly transfer to other buildings. These
modifications are consistent with the Fire Authority having jurisdiction.
5.08.150 Section 903.6-1w%111ended; Sections 903.6.2 and 903.6.3-Added.
Section 903.6 is amended and Section 903.6.2 and 903.6.3 are added to read as follows:
903.E Existing Buildings. All changes of occupancy classification in existing buildings
shall comply with the requirements contained in Section 903.2 of this code and Table 503
A the California Building Code.
903.6.2 When an addition to an existing building causes the total square footage of the
building to exceed the maximum floor area specified in Table 503 of the California
Building Code, fire sprinklers shall be installed throughout the entire building. Addition or
aIteration that removes 50% or more of the existing exterior walls of a building shall be
considered a new building for the purposes of Section 903.
903.6.3 Existing buildings which do not conform to Current Building Code or Fire Code
requirements may be required to install an automatic fire extinguishing system when an
interior alteration or remodeling occurs, regardless of whether the floor area is increased
or use changed. It shall be the responsibility of the Fire Code Official and the Building
Official to evaluate the work being performed, non -complying features, and determine if
an automatic fire extinguishing system will be required.
FINDING: The amendment is needed due to local climatic and topographical
conditions.
These modifications are necessary because the City of Dublin has a dry
period of at least five months each year. Additionally, The area is subject to
occasional drought. Because of dryness, a rapidly burning grass fire or
exterior building fire can quickly transfer to other buildings. These
modifications are consistent with the Fire Authority having jurisdiction.
5.08.160 Section 907.1-Amended; Sections 907.11, 907.11.1, 907.11.2 and 907.11.3-
Added
Section 907.1 is amended and Sections 907.11, 907.11.1, 907.11.2 and 907.11.3 are added
to read as follows:
907.1 General. This section covers the application, installation, performance and
maintenance of fire alarm systems and their components in new and existing buildings and
structures. The requirements of Section 907.2 are applicable to new buildings and
structures. The requirements of Section 907.9 are applicable to existing buildings and
structures. In the event of a conflict between this section and the provisions of Chapter 5.20
of the Dublin Municipal Code, the provisions of this section shall control.
907.11 False Alarms.
907.11.1 Excessive False Alarms. Malfunctions, or mechanical trip of any sprinkler alarm
or other fire protection or detection system resulting in an alarm and emergency dispatch of
the Fire Department shall be subject to a false alarm charge as established by this Code.
Page 6 of 45
Exception: During a thirty (30) day period following the installation of any new fire alarm
system, the Fire Chief shall determine if the false alarms emanating from said new
installation are excessive.
907.11.2 Charges. After the initial thirty (30) day period following the installation of a new
system, two (2) false alarms within a consecutive ninety (90) day period shall be deemed
excessive and will be charged as false alarms.
907.11.3 False Alarm charges are as follows:
1st false alarm - Warning Letter
2nd false alarm in any 90 day period- $100.00
3rd and subsequent false alarms in
any 90 day period- $200000
FINDING: These modifications are necessary to adopt the most current State standard
and to clarify specific areas of the code. In addition, these modifications will
make Chapter 5.08 consistent with Chapters 7.28, 7.32 and 7.34 of the Dublin
Municipal code.
5.08.170 Section 5003.2.4.2 Hazardous Materials General Provisions -Amended
Section 5003.2.4.2 is amended to read as follows:
5003.2.4.2 Above -ground tanks. Above -ground stationary tanks used for the storage of
hazardous materials shall be located and protected in accordance with the requirements
for outdoor storage of the particular material involved. Notwithstanding the foregoing,
above -ground stationary tanks used for the storage of flammable or combustible liquids is
prohibited in any area zoned for other than commercial, industrial, or agricultural use.
Exception: Above -ground tanks that are installed in vaults complying with Section
5303.16 or 5704.2.8 shall not be required to comply with location and protection
requirements for outdoor storage.
5703.2.4.2.1 Marking. Above -ground stationary tanks shall be marked as
required by Section 5003.5.
FINDING: This modification is necessary to adopt the most current State standard and
to clarify specific areas of the code.
5.08.180 Section 5601.1.1.3 Fireworks -Amended
Section 5601.1.3 is amended to add a fifth exception as follows:
5. The sale, use and discharge of fireworks are allowed in accordance with Chapter 5.24
of the Dublin Municipal Code.
FINDING: This modification is necessary to adopt the most current State standard and
to clarify specific areas of the code. In addition, these modifications will
make Chapter 5.08 consistent with Chapters 7.28 and 7.32 of the Dublin
Municipal code.
Page 7 of 45
5o08z19O Section 5704.2.9.6.1 Locations where above -ground tanks are prohibited -
Amended.
Section 5704.2.9.6.1 is amended to read as follows:
5704.2.9.6.1 Locations where above -ground tanks are prohibited. Storage of Class I
and II liquids in above -ground tanks outside of buildings is prohibited in any area zoned
for other than commercial, industrial, or agricultural use.
FINDINGow : This modification is necessary to adopt the most current State standard and
to clarify specific areas of the code and permitted locations of above around
tanks. In addition, these modifications will make Chapter 5.08 consistent
with Chapter 8 of the Dublin Municipal code.
5.08.200 Section 5706.2.4.4 Locations where above -ground tanks are prohibited —
Amended.
Section 5706.2.4.4 is amended to read as follows:
5706.2.4.4 Locations where above -ground tanks are prohibited. Storage of Class I
and II liquids in above -ground tanks outside of buildings is prohibited in any area zoned
for other than commercial, industrial, or agricultural use.
FINDING: This modification is necessary to adopt the most current State standard and
to clarify specific areas of the code and permitted locations of above ground
tanks. In addition, these modifications will make Chapter 5.08 consistent
with Chapter 8 of the Dublin Municipal code.
5.08.210 Section 5806.2 Limitations -Amended.
Section 5806.2 is amended to read as follows:
5806.2 Limitations. Storage of flammable cryogenic fluids in stationary containers
outside of buildings is prohibited within the limits established by law and in any area
zoned for other than commercial, industrial, or agricultural use.
FINDING: This modification is necessary to adopt the most current State standard and
to clarify specific areas of the code and permitted locations of above ground
tanks. In addition, these modifications will make Chapter 5.08 consistent
with Chapter 8 of the Dublin Municipal code.
5.08.220 Section 6104.2 Maximum capacity within established limits -
Amended.
Section 6140.2 is amended to read as follows:
6104.2 Maximum Capacity Within Established Limits. The limits referred to in Section
6104.2.1 of the 2019 California Fire Code in which storage of compressed natural gas is
prohibited, are hereby established as follows: Any area zoned for other than commercial,
industrial, or agricultural use.
FINDING: This modification is necessary to adopt the most current State standard and
to clarify specific areas of the code and permitted locations of above ground
tanks. In addition, these modifications will make Chapter 5.08 consistent
with Chapter 8 of the Dublin Municipal code.
Page 8 of 45
2. California Building Code.
7.32.120 Section 502.2.1, 502.2.2, 502.2.3, 502.2.4, Chapter 5, Address illumination.
Sections 502.2.1, 5020202, 502,203, 502.2.4 are added to read:
502.2.1 The address numbers) shall be illuminated during the hours of darkness. The
light source shall be provided with an uninterruptible AC power source or controlled by a
photoelectric device.
502.2.2 Exterior doors in commercial tenant space numbers shall be addressed as
required in section 501.2. Exception, dual doors may have the addresses on one door or
centered above the doors. In addition, all rear doors or service doors will have the name
of the business in 4-inch high lettering.
502.2.3 No other number may be affixed to a structure that might be mistaken for, or
confused with, the number assigned to the structure.
502.2.4 The assigned address, including the suite number, shall be displayed on all
electric meters in accordance with utility company standards.
FINDINGS The amendment is needed due to local geological and topographical
conditions.
These modifications are necessary due to the topographical nature of the
City and the easy access to freeways described in Section A of these
Findings. In light of said conditions, it is necessary to adopt these
requirements to enhance crime prevention. Additionally, this will bring the
code into conformance with the City of Dublin Police Department
requirements.
7.32.130 Section 507.14, Chapter 5, Frontage Restriction -Added.
A new Section 507.14 is added to read:
507.14 Frontage Restriction. The increase in area permitted by Sections 506.3, 507.1
through 507.13 of this Section shall not be allowed unless or until the owner of the
required yard shall file an agreement binding such owner, his heirs, and assignees, to set
aside the required yard as unobstructed space having no improvements. Such
agreement shall be recorded in the Alameda County Recorder's Office.
Exception: When using the public way for frontage increase.
FINDING: The amendment is needed due to local climatic and topographical
conditions.
This modification was necessary because the City of Dublin has a dry
period of at least five months each year. Additionally, the area is subject to
occasional drought. Because of dryness, a rapidly burning grass fire or
exterior building fire can quickly transfer to other buildings. These
modifications are consistent with the Fire Authority having jurisdiction.
Page 9 of 45
7.32.140 Section 706.1, Chapter 7, Fire Walls -Amended.
Section 706.1 is amended by adding a new subsection 706.1.2 to read:
706.1.2 Fire walls shall not be considered to create separate buildings for the purpose of
automatic fire -sprinkler system requi
aurements as set forth in Chapter 9.
FINDING: The amendment is needed due to local climatic and topographical
conditions.
This modification is necessary because the City of Dublin has a dry period
of at least five months each year. Additionally, the area is subject to
occasional drought. Because of dryness, a rapidly burning grass fire or
exterior building fire can quickly transfer to other buildings. These
modifications are consistent with the Fire Authority having iurisdiction.
7.32.150 Section 701A.1, Chapter 7A, Scope -Amended.
Section 701A.1 is amended to read:
701A.1 Scope. This Chapter applies to building materials, systems and/or assemblies
used in the exterior design and construction of new buildings located within a Wildland-
Urban Interface Fire Area as defined in Section 702A or adjacent to open space or
undeveloped land.
FINDING: The amendment is needed due to local climatic and topographical
conditions.
This modification was necessary because the City of_ Dublin has a d
period of at least five months each year. Additionally, the area is subject to
occasional drought. Because of dryness, a rapidly burning grass fire or
exterior building fire can quickly transfer to other buildings. These
modifications are consistent with the Fire Authority having iurisdiction.
7.32.160 Section 702A, Chapter 7A, Definitions -Amended
Section 702A is amended by adding new definitions as follows:
Adjacent to Open Space. Shall mean commercial parcels and residential lots which have a
point of contact with open space.
Adjacent to Undeveloped Land. Shall mean commercial parcels and residential lots which
have a point of contact with Undeveloped Land.
Open Space. For the purpose of this Chapter, Open Space shall mean those lands set aside to
remain permanently undeveloped.
Undeveloped Land. For the purpose of this Chapter, Undeveloped Land shall mean land
which is available for development but no Tentative Map, Master Tentative Map or Development
Agreement has been approved, and any land designated for government use for which no
development plan has been approved.
Page 10 of 45
FINDING• The amendment is needed due to local climatic and topographical
conditions.
These modifications are necessary because the City of Dublin has a dry
period of at least five months each year. Additionally, The area is subject to
occasional drought. Because of dryness, a rapidly burning grass fire or
exterior building fire can quickly transfer to other buildings. These
modifications are consistent with the Fire Authority having jurisdiction.
7.32.170 Sections 903.2.4.1, 903.2.9.1, 903.2.9.2, 903.2.10, 903.2.10.1-Deleted; Sections
903.2.1.1#11 HIM v2#1, 903.2.1.3#11 903.2.1.4#19 903.2.3#15 903.2.41
903.2.7#19 903.2.9, 903.2.11.3, Amended; and Sections 903.2.2.1 and 903.2.30-
Added.
Sections 903.2.4.1, 903826941, 903.2.9.2, 903.2.10 and 903.2,10.1 are deleted, Sections
903.2.1.1 #1, 903.2.1.2#1, 903.2.1.3#11 903.2.1.4#1, 9030293#11 9030244, 9030207#11 903.2.9,
and 903.2.11.3, are amended to read as follows, and Sections 903.2.2.1, and 903.2.30 are
added to read as follows:
903.2.1.1 Group A-1 Occupancies.
2. Where the floor area exceeds 3,000 square feet (279 m2).
903.2.1.2 Group A-2 Occupancies.
2. Where the floor area exceeds 3,000 square feet (279 m2).
903.2.1.3 Group A-3 Occupancies.
2. Where the floor area exceeds 3,000 square feet (279 m2).
903.2.1.4 Group A-4 Occupancies.
2. Where the floor area exceeds 3,000 square feet (279 m2).
903.2.2.1 Group B Occupancies.
An automatic fire -extinguishing system shall be installed in Group B occupancies where
the floor area exceeds 3,000 square feet (279 m2).
903.2.3 Group E Occupancies.
2. An automatic fire -sprinkler system shall be in Group E, occupancies where the floor
area exceeds 3,000 square feet (279 m2).
903.2.4 Group F Occupancies.
An automatic fire sprinkler system shall be installed in all Group F occupancies where the
floor area exceeds 2,500 square feet (232 m2).
(Section 903.2.4.1 is deleted)
903.2.7 Group M Occupancies.
1. An automatic sprinkler system shall be installed in Group M occupancies where the
floor area exceeds 2,500 square feet (232 m2).
903.2.9 Group S Occupancies.
An automatic sprinkler system shall be installed in all Group S occupancies as follows:
1. Where the floor area exceeds 2,500 square feet (232 m2);
Page 11 of 45
2. Buildings with repair garages servicing vehicles parked in basements.
(Sections 903.2.4.1, 903.2.9.1, 903.2.9.2, 903.2.10, 903.2.10.1 are Deleted)
903.2.11.3 Buildings Three or More Stories in Height.
An automatic sprinkler system shall be installed in all occupancies, regardless of type of
construction, if the building is three or more stories or more than 35 feet in height
measured from the pad grade level to the highest point of the building. An automatic
sprinkler system shall be installed in all other occupancies as may be required by the
2019 California Building Code.
903.2.30 All Occupancies
An automatic fire -extinguishing system shall be installed in all occupancies located
more than one and one half (1 Y2) miles from a fire station providing fire protection to that
location. Said distance shall be measured in a straight line.
Buildings containing portions which are required to have an automatic fire extinguishing
system because of the number of stories shall have the automatic fire extinguishing
system installed throughout and fire walls as set forth in Section 706 shall not be
considered as creating separate buildings for the purpose of this section.
Whenever an addition is made to an existing building automatic fire -extinguishing
system shall be installed if the existing building plus the addition exceeds the area or
height limitations set forth in this section. Whenever the use of an existing building or
portion thereof is changed in any manner so as to require the installation of an automatic
fire -extinguishing system, said system shall be installed in that portion of the building
housing the new use.
FINDING: The amendment is needed due to local climatic and topographical
conditions.
These modifications are necessary because the City of Dublin has a dry
period of at least five months each year. Additionally, the area is subject to
occasional drought. Because of dryness, a rapidly burning grass fire or
exterior building fire can quickly transfer to other buildings. These
modifications are consistent with the Fire Authority having jurisdiction.
7.32.180 Section 1505.1, Chapter 15, Fire Classification -Amended.
Section 1505.1 is amended to read:
1505.1 General. Roof Assemblies shall be divided into the classes defined below. Class
A, B, and C roof assemblies and roof coverings required to be listed by this section shall
be tested in accordance with ASTM E 108 or UL 790. In addition, fire -retardant -treated
wood roof coverings shall be tested in accordance with ASTM D 2898. The minimum
roof coverings installed on buildings shall comply with the following:
1. Map of Fire Safe Roof Areas. Figure 15-1 * is a map of Fire Safe Roof areas. Said
map may be amended from time to time by including areas which are annexed to
the City within one of the two roofing areas. Said amendments may be made by the
Building Official after consultation, with the Chief of the Fire Department having
jurisdiction.
Page 12 of 45
2. Roofing Area 1. Any new roof and any alteration, repair or replacement for
buildings housing R & U occupancies in Roofing Area 1 shall use roof covering
material that conforms to Class B or better or shall be made of concrete, ferrous or
copper metal, clay, slate or similar non-combustible material.
3. Roofing Area A. Any new roof for buildings using roof covering material that
conforms to Class C or better or shall be made of concrete, ferrous or copper metal,
clay, slate or similar non-combustible material.
4. Other Occupancies. Any new roof covering and any alteration, repair or
replacement of roof covering material for buildings housing all other occupancies
shall conform to the requirements as set forth in Roofing Area 1.
*Editor's Note: Figure 15-1 is on file in the office of the City Clerk.
FINDING• The amendment is needed due to local climatic and topographical
conditions.
This modification was necessary because the City of Dublin has a dry
period of at least five months each year. Additionally, The area is subject to
occasional drought. Because of dryness, a rapidly burning grass fire or
exterior building fire can quickly transfer to other buildings. These
modifications are consistent with the Fire Authority having jurisdiction.
7.32.190 Table 1607.1, Chapter 16, Uniform and concentrated live loads -Amended.
Table 1607.1 is amended by adding a new Footnote Q to read:
Q. Bridges for vehicular traffic shall be designed for H2O loading as designated by the
American Association of State Highway Officials.
FINDING• The amendment is needed due to local geological, climatic and
topographical conditions.
This modification was necessary because bridges were not addressed by
the Building Code. Additionally due to the City's terrain a number of bridges
and overpasses may be required.
7.32.200 Section 1705.3, Exception 1, Chapter 17, Concrete Construction -Amended
Section 1705.31 Exception 1 is amended to read:
1. Isolated spread concrete footings of buildings three stories or less above grade
plane that are fully supported on earth or rock, where the structural design of the
footing is based on a specified compressive strength, f'c, no greater than 2,500
pounds per square inch (psi) (17.2 Mpa) regardless of the compressive strength
specified in the construction documents or used in the footing construction.
Page 13 of 45
FINDINGS: The amendment is needed due to local geological, climatic and
topographical conditions.
The San Francisco Bay area region is densely populated and/or located in an
area of high seismic activities as indicated by United States Geological
Survey and California Division of Mines and Geology. Recent earthquake
activities, including the 1989 Loma Prieta earthquake, have indicated the
lack of adequate design and detailing as a contributing factor to damages
that reduced the protection of the life -safety of building occupants. The City
of Dublin is a densely populated area having buildings constructed near
potentially active faults. The Association of Bay Area Governments (ABAG)
roughly estimates the probability of a serious earthquake along the Hayward
Fault as one -in -four in the next 30 years, while the USGS predict the
probability of a powerful quake in the next 30 years at 72%. The proposed
modification to ensure that the design of slender wall must satisfy both
strength and serviceability requirements need to be incorporated into the
code to assure that new buildings and additions to existing buildings are
designed and constructed in accordance with the scope and oboectives of
the International Building Code.
7.32.210 Section 1905.1.7, Chapter 19, ACI 318, Section 14.1.4-Amended
Section 1905.1.7, Delete ACI 318, Section 14.1.4 and replace with the following:
14.1.4 -Plain concrete in structures assigned to Seismic Design Category C, D, E or F.
14.1.4.1 - Structures assigned to Seismic Design Category C, D, E or F shall not have
elements of structural plain concrete, except as follows:
(a) Isolated footings of plain concrete supporting pedestals or columns are permitted,
provided the projection of the footing beyond the face of the supported member does
not exceed the footing thickness.
Exception:
In detached one and two-family dwellings, three stories or less in height, the
projection of the footing beyond the face of the supported member is permitted to
exceed the footing thickness.
(b) Plain concrete footing supporting walls are permitted, provided the footings have at
least two continuous longitudinal reinforcing bars. Bars shall not be smaller than No.
4 and shall have a total area of not less than 0.002 times the gross cross -sectional
area of the footing. A minimum of one bar shall be provided at the top and bottom of
the footing. Continuity of reinforcement shall be provided at corners and
intersections.
Exception: .
In detached one and two-family dwellings, three stories or less in height and
constructed with stud bearing walls, plain concrete footings —with at least two
continuous longitudinal reinforcing bars not smaller than No. 4 are permitted to
have a total area of less than 0.002 times the gross cross —sectional area of the
footing.
Page 14 of 45
FINDINGS: The amendment is needed due to local geological, climatic and
topographical conditions.
This amendment addresses the problem of poor performance of plain or
under reinforced concrete footings during a seismic event. This amendment
reflects the recommendations by the Structural Engineers Association of
Southern California (SEAOSC) and the Los Angeles City Joint Task Force
that investigated the poor performance of plain and under -reinforced
concrete footings observed in the 1994 Northridge earthquake.
The San Francisco Bav area region is densely populated and/or located in an
area of high seismic activities as indicated by United States Geological
Survey and California Division of Mines and Geology. Recent earthquake
activities, including the 1989 Loma Prieta earthquake, have indicated the
lack of adequate design and detailing as a contributing factor to damages
that reduced the protection of the life -safety of building occupants. The City
of Dublin is a densely populated area having buildings constructed near
potentially active faults. The Association of Bay Area Governments (ABAG)
roughly estimates the probability of a serious earthquake along the Hayward
Fault as one -in -four in the next 30 years, while the USGS predict the
probability of a powerful quake in the next 30 years at 72%. The proposed
modification to ensure that the design of slender wall must satisfy both
strength and serviceability requirements need to be incorporated into the
code to assure that new buildings and additions to existing buildings are
designed and constructed in accordance with the scope and objectives of
the International Building Code.
7.32.220. Table 2308.6.1, Chapter 23, Wall Bracing Requirements -Amended.
Table 2308.6.1 is amended by adding new footnotes "f' and "g" to read:
£ Method GB does not apply in Seismic Design Category D and E.
g. Method PCP in Seismic Design Category D and E is limited to single story U
occupancies.
FINDING: The amendment is needed due to local geological conditions.
This section limits the use of gvpsum board for lateral bracing in Seismic
Design Category D and E. This amendment is necessary because the City of
Dublin is located in Seismic Zone D and E. Gypsum wallboard has
performed poorly during recent California seismic events. The shear values
for gypsum wallboard contained in the code are based on mono -directional
testing. It is appropriate to limit the use of this product until cyclic loading
tests are performed and evaluated.
This section limits the use of Portland cement plaster for lateral bracing to
single story residential accessory buildings or structures. This limitation is
necessary because the City of Dublin is located in Seismic Zone E and E.
Exterior Portland cement plaster has performed poorly during recent
California seismic events. The shear values for Portland cement stucco
contained in the code are based on mono -directional testing. It is
Page 15 of 45
appropriate to limit the use of this product until cyclic loading tests are
performed and evaluated.
7.32.230 Section 2308.6.9, Attachment of Sheathing -Amended.
Section 2308.6.9, is amended by adding a second paragraph:
All braced wall panels shall extend to the roof sheathing and shall be attached to parallel
roof rafters or blocking above with framing clips (18 gauge minimum) spaced at maximum
24 inches (6096 mm) on center with four 8d nails per leg (total eight 8d nails per clip).
Braced wall panels shall be laterally braced at each top corner and at maximum 24 inch
(6096 mm) intervals along the top plate of discontinuous vertical framing.
FINDINGS: The amendment is needed due to local geological, climatic and
topographical conditions.
The San Francisco Bay area region is densely populated and/or located in an
area of high seismic activities as indicated by United States Geological
Survey and California Division of Mines and Geology. Recent earthquake
activities, including the 1989 Loma Prieta earthquake, have indicated the
lack of adequate design and detailing as a contributing factor to damages
that reduced the protection of the life -safety of building occupants. The City
of Dublin is a densely populated area having buildings constructed near
potentially active faults. The Association of Bay Area Governments (ABAG)
roughly estimates the probability of a serious earthquake along the Hayward
Fault as one -in -four in the next 30 years, while the USGS predict the
probability of a powerful quake in the next 30 years at 72%. The proposed
modification to ensure that the design of slender wall must satisfy both
strength and serviceability requirements need to be incorporated into the
code to assure that new buildings and additions to existing buildings are
designed and constructed in accordance with the scope and objectives of
the International Building Code.
7.32.240 Section 3115.1, Chapter 31, Prohibited Installations —Added.
A new Section 3115.1 is added to read:
3115.1 Prohibited Installations. It shall be unlawful to install a wood burning fireplace
or appliance that is not one of the following:
1) Pellet -fueled wood heater,
2) EPA certified wood heater,
3) Fireplace certified by EPA
FINDING: The amendment is needed due to local climatic and topographical
conditions.
This modification was necessary because fireplaces and wood stoves
generate 40 percent of the particulate matter in the Bay Area during the
winter months. Of greater concern are the fine particles, which can lodge
deep in the lungs causing permanent lung damage and increasing mortality.
Burning wood also generates carbon monoxide, nitrogen dioxide, volatile
organic and toxic air pollutants.
Page 16 of 45
7.32.250 Section 3203, Chapter 32, Signs -Added.
A new Section 3203 is added to read:
3203 Signs. Signs when placed flat against the wall of a building shall not project
beyond the front property line more than 12 inches (305mm).
FINDING. The amendment is needed due to local climatic and topographical
conditions.
This modification was necessary due to the City of Dublin's basic wind
sPeed requirement relating to the high winds described in Section A of these
Findings.
7.32.260 Section H101.2, Signs exempt from permits -Deleted.
Section H101.2 is deleted.
FINDING: The amendment is needed due to local climatic and topographical
conditions.
This modification was necessary due to the City of Dublin's basic wind
sPeed requirement relating to the high winds described in Section A of these
Findings.
7.32.270 Section 1010, Appendix Chapter 10, Building security —Added.
Appendix Chapter 10 is added to read:
Section 1010 building security shall be in accordance with the Uniform Building Security Code in
addition to the following:
Editor's Note: See Chapter 7.34 Residential Code for single family or townhouse
requirements.
(A) Addressing. All buildings shall be addressed as follows:
(1) Walkways serving six (6) or more individual units where the front entrance is not parallel
to the street and driveways servicing six (6) or more individual dwelling units shall have
minimum of 4 inch high identification numbers, noting the range of unit numbers placed at the
entrance to each driveway at a height between thirty-six (36) and forty-two (42) inches above
grade. The address numbers shall be illuminated during the hours of darkness. The light
source shall be provided with an uninterruptible AC power source or controlled only by a
photoelectric device.
(2) There shall be positioned at each street entrance of a multi- family complex having more
than one structure, an illuminated diagrammatic representation (map) of the complex that shows
the location of the viewer and the unit designations within the complex. It shall be lighted during
the hours of darkness utilizing a light source, which is constructed of weather and vandal
resistant materials and provided with an uninterruptible AC power source or controlled by a
photoelectric device. Nothing in this section shall preclude the requirement for circuit protection
devices where applicable.
(3) If the building is adjacent to an alley, the number shall also be placed on or adjacent to
the rear gate accessing the alley. Any building with vehicular access to the rear through a
Page 17 of 45
public or private alley shall display, in a clearly visible location, a highly reflective or illuminated
address number a minimum of four (4) inches in height.
(4) Where more than one (1) building is accessed by a common street entrance or there are
multiple buildings on the same lot, each principal building shall display the number or letter
assigned to that building on each corner of the building, as determined by the Building Official.
These numbers shall be made visible during the hours of darkness. The street name may also
be required when there is a secondary street frontage.
(5) Addressing shall not be obstructed by architectural structures such as trellises, arbors,
balconies, light fixtures and or landscaping.
(6) In Commercial Day Care or Education facilities, all interior and exterior doors shall be
provided with a room number on the door. A map of the facilities detailing location of all rooms
and their uses shall be kept on file at the facilities on -site office.
(B) Exterior Openings. Exterior opening shall be as follows:
(1) Swinging exterior wood and steel doors shall be equipped as follows:
(a) A single or double door shall be equipped with a double or single cylinder deadbolt.
The bolt shall have a minimum projection of one (1) inch and be constructed so as to
repel cutting tool attack. The deadbolt shall have an embedment of at least three -fourths
(3/4) inch into the strike receiving the projected bolt. The cylinder shall have a cylinder
guard, a minimum of five pin tumblers and shall be connected to the inner portion of the
lock by connecting screws of at least one-fourth (1/4) inch in diameter. The provisions of
the this paragraph do not apply where: (a) panic hardware is required, (b) conflicts with
emergency egress requirements of the building and fire codes or (C) an equivalent
device is approved by the authority having jurisdiction.
(b) Doorstop on a wooden jamb for an in -swing door shall be of one-piece construction
with the jamb joined by a rabbit.
(c) For the purpose of this section, doors leading from garage areas into a dwelling are
exterior doors.
(2) Double doors shall be equipped as follows:
(a) The inactive leaf of double door(s) shall be equipped with metal flush bolts that have
a minimum embedment of five -eighths (5/8) inch into the head and threshold of the
doorframe.
(b) Double doors shall have an astragal constructed of steel a minimum of .125 inch
thick, which will cover the opening between the doors. The astragal shall be a minimum
of two (2) inches wide and extend a minimum of one (1) inch beyond the edge of the door
to which it is attached. The astragal shall be attached to the outside of the active door by
means of welding or with non -removable bolts spaced apart on not more than ten (10)
inch centers. (The door to which such an astragal is attached must be determined by the
fire safety codes adopted by the enforcing authority.)
(3) Aluminum frame swinging doors shall be equipped as follows:
Page 18 of 45
(a) The jamb on all aluminum frame -swinging doors shall be so constructed or protected
to withstand 1,600 pounds of pressure in both a vertical distance of three (3) inches and
a horizontal distance of one (1) inch each side of the strike, to prevent violation of the
strike.
(b) A single or double door shall be equipped with a double cylinder deadbolt with a bolt
projection exceeding one (1) inch, or a hook shaped or expanding dog bolt that engages
the strike sufficiently to prevent spreading. The deadbolt lock shall have a minimum of
five pin tumblers and a cylinder guard.
(4) Panic hardware, whenever required by the California Building Code or Title 19, California
Administration Code, shall be installed as follows;
(a) Panic hardware shall contain a minimum of two (2) locking points on each door; or
(b) On single doors, panic hardware may have one locking point, which is not to be
located at either the top or bottom frame. The door shall have an astragal constructed of
steel .125 inch thick, which shall be attached with non -removable pins to the outside of
the door. The astragal shall extend a minimum of six (6) inches vertically above and
below the latch of the panic hardware. The astragal shall be a minimum of two (2) inches
wide and extend a minimum of one (1) inch beyond the edge of the door to which it is
attached.
(c) Double doors containing panic hardware shall have an astragal attached to the doors
at their meeting point, which will close the opening between them, but not interfere with
the operation of either door. (The astragal shall not interfere with the safe operation of
emergency egress).
(5) Horizontal or Sliding Doors shall be installed as follows:
(a) In commercial occupancies, horizontal sliding doors shall be equipped with a metal
guide track at top and bottom and a cylinder lock and/or padlock with a hardened steel
shackle which locks at both heel and toe, and a minimum five pin tumbler operation with
non -removable key when in an unlocked position. The bottom track shall be so designed
that the door cannot be lifted from the track when the door is in a locked position.
(b) In residential occupancies, locks shall be provided on all sliding patio doors. The lock
bolt on all glass patio doors shall engage the strike sufficiently to prevent its being
disengaged by any possible movement of the door within the space or clearance
provided for installation and operation. The strike area shall be of material adequate to
maintain effectiveness of bolt strength.
(c) Sliding patio glass doors opening onto patios or balconies which are less than one
story above grade or are otherwise accessible from the outside shall have the moveable
section of the door sliding on the inside of the fixed portion of the door or possess an
approved secondary lock mounted on interior of moveable section.
(6) In office buildings (multiple occupancy), all entrance doors to individual office suites shall
meet the construction and locking requirements for exterior doors.
Page 19 of 45
(7) In commercial occupancies, windows shall be deemed accessible if less than twelve (12)
feet above the ground. Accessible windows having a pane exceeding ninety-six (96) square
inches in an area with the smallest dimension exceeding six (6) inches and not visible from a
public or private thoroughfare shall be protected with burglary resistant glazing or other
approved methods as determined by the Building Official.
(8) Side or rear windows of the type that can be opened shall, where applicable, be secured
on the inside with either a slide bar, bolt, crossbar, auxiliary locking device, and/or padlock with
a hardened steel shackle, a minimum four pin tumbler operation.
(9) Protective bars or grills shall not interfere with the operation of opening windows if such
windows are required to be operable by the California Building Code.
(10) All exterior transoms exceeding ninety-six (96) square inches on the side and rear of
any building or premises used for business purposes shall be protected with burglary resistant
glazing or other approved methods as determined by the Building Official.
(11) Roof openings shall be equipped as follows:
(a) All skylights on the roof of any building or premises used by business purposes shall
be provided with:
(1) Rated burglary resistant glazing; or
(2) Iron bars of at least one-half (1/2) inch round or one by one-fourth (1 x'/4) inch
flat steel material under the skylight and securely fastened; or
(3) Steel grills of at least one -eighth (1/8) inch material with a maximum two (2)
inches mesh under the skylight and securely fastened.
(4) A monitored intrusion alarm system. The system shall be kept operable at all
times. The Chief of Police may require periodic testing of the alarm system to
verify proper operation.
(b) All hatchway openings on the roof of any building or premises used for business
purposes shall be secured as follows:
(1) If the hatchway is of wooden material, it shall be covered on the inside with at
least sixteen (16) U.S. gauge sheet metal, or its equivalent, attached with screws.
(2) The hatchway shall be secured from the inside with a slide bar or slide bolts.
(Fire Department approval may be desired.)
(3) Outside hinges on all hatchway openings shall be provided with non -
removable pins when using pin -type hinges.
(c) All air duct or air vent openings exceeding ninety-six (96) square inches on the roof or
exterior walls of any building or premises used for business purposes shall be secured by
covering the same with either of the following:
Page 20 of 45
(1) Iron bars of at least one-half (1/2) inch round or one by one-fourth (1 x /4) inch
flat steel material spaced no more than five (5) inches apart and securely
fastened; or
(2) Iron or steel grills of at least one -eighth (1/8) inch material with a maximum
two (2) inch mesh and securely fastened.
(3) If the barrier is on the outside, it shall be secured with bolts which are non -
removable from the exterior.
(4) The above must not interfere with venting requirements creating a potentially
hazardous condition to health and safety or conflict with the provisions of the
California Building Code or Title 19, California Administrative Code.
(12) Exterior roof ladders shall not be permitted.
(13) Exterior electrical or phone panels are not permitted in commercial occupancies.
(14) Separation walls for individual commercial tenant spaces housed within a common
structure shall be solid with sheathing and continuous from the structure's foundation to roof or
floor / ceiling assembly. If both sides of the tenant spaces are accessible, then each side shall
be sheathed.
(15) Intrusion Devices.
(a) If the enforcing authority determines that the security measures and locking devices
described in this Chapter do not adequately secure the building, due to special
conditions, he/she may require the installation and maintenance of an intrusion device
(burglar alarm system).
(C) Landscaping.
(1) Shrubs and ground cover shall not directly cover windows and doorways.
(2) River rock used near parking lots or buildings shall be permanently affixed.
(3) Open space and buildings shall be arranged to afford visibility and opportunity for
surveillance by on -site users and passers-by.
(4) Barriers, both real and symbolic, shall be designed to afford opportunities for
surveillance through the barrier.
(5) For residential development, backyard gates shall be the full height of the wall or fence
adjacent and capable of being locked.
(6) For residential development, walls or fences,
height when adjacent to any of the following:
Reverse frontage
Retention/detention areas
if installed, shall be a minimum of 6 feet in
Parks
Page 21 of 45
Commercial areas
Industrial areas
Bike paths
(D) Lighting. Lighting of buildings or complexes shall at a minimum be illuminated as
follows:
(1) A site plan shall UP[ VV V showing bungs, parking areas, walkways, detailed
landscaping and a point by point photometric calculation of the required light levels.
(2) All exterior entrances shall be illuminated with a uniformly maintained minimum level of
one foot candle of light between ground level and 6 vertical feet within a minimum radius of 15
feet from the center of the entrance between sunset and sunrise.
(3) Postal Service "gang boxes" (group postal boxes) shall be illuminated with a uniformly
maintained minimum level of one foot candle of light.
(4) Lighting of all exterior areas shall be designed to maximize surveillance and reduce
conflicts with building design, mature landscaping, and to minimize glare.
(5) Open stairways shall be illuminated with a minimum maintained five -tenths (0.5) foot-
candle of light in all landings and stair treads between sunset and sunrise. Enclosed stairways
and enclosed common corridors shall be illuminated at all times with a minimum maintained
one -foot candle of light on all landings and stair treads.
(6) Private streets, alleys, and emergency access roads shall be illuminated using the same
standards as established for public thoroughfares.
(7) Aisles, passageways, pedestrian walkways and recessed areas related to and within a
building, a building complex, or providing access to a building or building complex from a
parking lot or right of way shall be illuminated with a minimum uniformly maintained minimum
level of one foot candle of light between ground level and six vertical feet between sunset and
sunrise or other methods approved by the Building Official.
(8) Open parking lot Al carport and refuse areas shall be provided with and maintained
to a minimum of one foot-candle of light on the parking surface. The Building Official may
approve a lower light level, if it can be demonstrated that the lower level provides for sufficient
security lighting.
(9) Covered parking lots or covered portions of parking lots shall be illuminated with a
uniformly maintained minimum level of one -foot candle of light between ground level and 6
vertical feet between sunset and sunrise. Lighting shall be designed so that architectural or
structural features do not obstruct the minimum light coverage.
(10) Parking structures or enclosed or partially enclosed parking lots shall be illuminated
with a uniformly maintained minimum level of two foot candles of light between ground level and
6 vertical feet between sunrise and sunset (daylight hours).
(11) Lighting fixtures shall be so arranged as to illuminate light uniformly over the parking
surface and be tamper resistant.
Page 22 of 45
(12) Public rest rooms, rooms identified for the general public and children's recreation
areas shall be provided with emergency lighting meeting section 1006 of this Code.
All light sources required by this section shall be: (a) controlled by a photocell device or a time
clock that will turn the lights on at dusk and off at dawn and (b) protected by weather and vandal
resistant covers.
(E) Garage Type (Vehicle) Doors. Garage -type doors, which are either rolling overhead,
solid overhead, swinging, sliding, or accordion style doors shall conform to the following
standards;
(1) Wood doors shall have panels a minimum of five -sixteenths (5/16) inch in thickness with
the locking hardware being attached to the support framing.
(2) Aluminum doors shall be a minimum thickness of .0215 inches and riveted together a
minimum of 18 inches on center along the outside seams. There shall be a full width horizontal
beam attached to the main door structure which shall meet the pilot, or pedestrian access, door
framing within 3 inches of the strike area of the pilot or pedestrian access door.
(3) Fiberglass doors shall have panels a minimum density of 6 ounces per square foot from
the bottom of the door to a height of 7 feet. Panels above 7 feet and panels in residential
structures shall have a density not less than 5 ounces per square foot.
(4) Doors utilizing a cylinder lock shall have a lock receiving point at each outer edge of the
door; or, of the door does not exceed 19 feet, a single bolt may be used if placed in the center of
the door with the locking point located either at the floor or door frame header.
(5) Doors with slide bolt assemblies shall have frames a minimum of .120 inches of
thickness, with a minimum bolt diameter of one half (1/2) inch and protrude at least one and one
half (1 Y2) inches into the receiving guide. A bolt diameter of three -eighths (3/8) inch may be
used in a residential building. The slide bolt shall be attached to the door with non -removable
bolts from the outside. Rivets shall not be used to attach slide bolt assemblies.
(6) Padlocks used with exterior mounted slide bolts shall have a hardened steel shackle
locking at both heel and toe and a minimum five pin tumbler operation with non -removable key
when in an unlocked position. Padlocks used with interior mounted slide bolts shall have a
hardened steel shackle with a minimum 4-pin tumbler operation.
(F) Emergency Access
(1) Private roads and parking areas or structures controlled by unmanned mechanical
parking type gates shall provide for emergency access as follows:
Radio frequency access or by providing the gate access code for distribution to
emergency responders. When an access code is to be utilized, an illuminated control box is
to be mounted on a control pedestal consisting of a metal post/pipe, which shall be installed
at a height of 42 inches and a minimum of 15 feet (4.6m) from the entry/exit gate. It shall be
located on the driver's side of the road or driveway and accessible in such a manner as to
not require a person to exit their vehicle to reach it, nor to drive on the wrong side of the road
or driveway, nor to require any back-up movements in order to enter/exit the gate.
Page 23 of 45
(2) Non-residential multi -tenant buildings utilizing electronic access control systems on the
main entry doors, and enclosed retail shopping centers shall be provided with a means to allow
for police emergency access.
(3) Pedestrian gates/doors using an electromagnetic type lock shall install a key switch
within a telephone/intercom console or in a control housing, or other method approved by the
Building Official that will provide for police emergency access. Options include radio frequency
access or providing the gate access code for distribution to emergency responders.
(4) All lockable pedestrian gates to residential recreation areas serving 6 or more dwelling
units, and gates or doors to common walkways or hallways of residential complexes where
there are 4 or more dwelling units within the complex, shall provide for police emergency access
utilizing an approved key switch device or approved Knox box. The Knox box shall be installed
adjacent to each gate/door, securely attaching it to a fence or wall or location approved by the
Building Official.
(5) Pedestrian gate doors utilizing mechanical locks shall install a Knox box adjacent to
each gate/door, securely attaching it to a fence or wall
(G) Keying requirements
Upon occupancy by the owner or proprietor, each single unit in a tract or commercial
development, constructed under the same site development review, shall have locks using
combinations that are interchange free from locks used in all other separate dwellings,
proprietorships, or similar distinct occupancies.
(H) Laundry rooms or areas: Common area laundry rooms in multi -family complexes shall
be designed and protected as follows:
(1) Entry doors shall have:
(a) A minimum six hundred (600) square inch clear vision panel in the upper half of the
door, consisting of/4" tempered glass;
(b) Automatic, hydraulic door closures;
(c) Self-locking door locks equipped with a deadlocking latch allowing exiting by a single
motion and openable from the inside without the use of a key or any special knowledge
or effort;
(d) Non -removable hinge pins for out -swinging doors to preclude removal of the door
from the exterior by removing the hinge pins; and
(e) A latch protector consisting of minimum 0.125-inch4hick steel attached to the door's
exterior by non -removable bolts from the exterior. It shall be two (2) inches wide and
extend a minimum of five inches above and below the strike opening and extend a
minimum of one (1) inch beyond the edge of the door. It shall have a metal anti -spread
pin a minimum of one-half (1/2) inch in length.
(2) The laundry room shall be illuminated at all times with a minimum maintained one -foot
candle of light at floor level, using anon -interruptible power source. There shall be no light
switches inside the room that control light fixtures used to meet this lighting requirement.
Page 24 of 45
(3) Any portion of an openable window which is within eight (8) feet vertically or six (6) feet
horizontally from any accessible surface or any adjoining roof, balcony, landing, stair tread,
platform, or similar surface, or any climbable pole or tree, or any surface providing a foothold,
shall be secured as required by section 1018 of the Uniform Building Security Code.
(4) The interior of laundry rooms shall be visible from the exterior along common walking or
driving surfaces. Perimeter windows and interior mirrors may be utilized to meet this
requirement. Laundry rooms are to be located in high activity areas,with natural surveillance
opportunities and not in remote or isolated locations.
(I) Elevators
Elevators shall be designed as follows:
Elevator cabs, the interiors of which are noY completely visible when the door is open
from a point centered on the 36 inches away from the door shall have shatter resistant
mirrors or other equally reflective material so placed as to make visible the entire elevator
cab from this point. The elevator cab shall be illuminated at all times with a minimum
maintained 2 foot candles of light at floor level.
(J) Stairways
Except for private stairways, Stairways shall be designed as follows:
(1) Interior doors shall have glazing panels a minimum of 5 inches wide and 20 inches in
height and meet requirements of the California Building Code.
(2) Areas beneath stairways at or below ground level shall be fully enclosed or access to
them restricted.
(3) Enclosed stairways shall have shatter resistant mirrors or other equally reflective
material at each level and landing and be designed or placed in such manner as to provide
visibility around corners.
(K) Parking structures.
(1) Parking structures shall be designed to restrict unauthorized access.
(2) Outside stairwells shall be open and not obstructed from view
(3) Security telephones with monitoring capability shall be located on every level adjacent to
pedestrian ingress/egress points. If pedestrian ingress/egress points are more than 200 feet but
less than 300 feet apart, additional security telephones shall be located at the midpoint between
pedestrian ingress/egress points. If pedestrian ingress/egress points are more than 300 feet
apart, security telephones will be located at 100 foot intervals. Security telephones shall be
visible from all vehicular and pedestrian ingress/egress points and identified with appropriate
signage.
(4) Blind corners shall be provided with shatterproof convex mirrors to improve visibility for
both operators of vehicles and pedestrians.
(5) Doors shall be labeled with signage meeting the requirements of section 501.2
Page 25 of 45
(6) Parking structures shall have the ceiling area of each floor or tier painted and maintained
white or other reflective color approved by the Building Official.
(L) Other requirements
(1) Storage Areas. Exterior storage area attached to a dwelling, apartment or condominium
and enclosed by a door shall comply with this section or have a minimum 3/8" diameter
hardened padlock hasp.
(2) Side Gates. Side gates shall be the full height of the adjacent fence or wall and be
capable of being locked. Side gates shall be secured with a slide bolt mounted on the inside of
the gate. The slide bolt shall have a bolt diameter of three -eighths (3/8) inch and protrude at
least one and one-half (1 Y2) inches into the receiving guide. The slide bolt shall be attached to
the gate with non -removable bolts. Rivets shall not be used to attach slide bolt assemblies.
The slide bolt shall be mounted at a height that is not accessible by reaching over the gate.
FINDINGS The amendment is needed due to local geological and topographical
conditions.
These modifications are necessary due to the topographical nature of the
City and the easy access to freeways described in Section A of these
Findings. In light of said conditions, it is necessary to adopt these
requirements to enhance crime prevention. Additionally, this will bring the
code into conformance with the City of Dublin Police Department
requirements.
Page 26 of 45
3. California Residential Code.
7.342110 Table R301.2(1), Chapter R3 — Amended
Table R301.2(1) is amended to read:
GROUND
SNOW
R1ND
DESIGN:
SEISIdIG
DESIGN
SUBJECTTODAMAGEFROId:
ICEBARRIER
UNDERLAYMENT
Speed•
Topographic
Special
Wind-
LOAD:
(mph):
effects`=
sand
home
CATEGORY':
Frost
WINTER
REQUIRED':=
FLOOD
AIR
MEAN
region.
debns
line
DESIGN
HAZARDS
FREEZING
ANNUAL
zone'*
Wealhenn •:
de Ihra
Termite:
TEr.1P':
,:
INDEX'c
TEMPT
MAD
1100
NOD
NOD
NOD
D,a
Negligible0
12"a
Vely-
330a
NOD
944-
1
1 Heavyc
87a
04000❑
58.7❑
MANUAL J DESIGN CRITERIA"
Summer
Altitude
Indoor design
Design
Heating
Elevation
Latitude
Winter healing
cooling
correction
temperature
temperature
temperature
factor
cooling
difference
200
38
32
90
1
68
75
36
Cooling temperature
Wind velocity
Wind velocity
Coincident wet
Daily range
Winter humidity
Summer humidity
Blank
difference
healing
cooling
bulb
15
15 mph
7.5 mph
67
35
75%
75%
Blank
FINDINGS: The amendment is needed due to local geological, climatic and
topographical conditions.
The San Francisco Bav Area region is densely aopulated and/or located in
an area of high seismic activities as indicated by United States Geological
Survey and California Division of Mines and Geology. Recent earthquake
activities, including the 1989 Loma Prieta earthquake, have indicated the
lack of adequate design and detailing as a contributing factor to damages
that reduced the protection of the life -safety of building occupants. The City
of Dublin is a densely populated area having buildings constructed near
potentially active faults. The Association of Bay Area Governments (ABAG)
roughly estimates the probability of a serious earthquake along the Hayward
Fault as one -in -four in the next 30 years, while the USGS predict the
probability of a powerful quake in the next 30 years at 72%. The proposed
modification to ensure that the design of slender wall must satisfy both
strength and serviceability requirements need to be incorporated into the
code to assure that new buildings and additions to existing buildings are
desianed and constructed in accordance with the scope and objectives of
the International Building Code.
7.34.120 Section R313.1 Exception, Chapter R3 Automatic Fire Sprinkler Systems —
Amended.
Section R313.1 Exception is amended to read:
Exception:
An automatic residential fire sprinkler system shall not be required for additions or
alteration to existing building that are not already provided with an automatic
residential sprinkler system, provided that the total square footage of the existing
building plus the addition does not exceed 3600 square feet (334m2). Additions or
alteration that remove 50 percent or more of the existing exterior walls of a dwelling
shall be considered a new dwelling for the purposes of Section R313.1.
Page 27 of 45
FINDING: The amendment is needed due to local climatic and topographical
conditions.
This modification was necessary because the City of Dublin has a dry
period of at least five months each year. Additionally, The area is subject to
occasional drought. Because of dryness, a rapidly burning grass fire or
exterior building fire can quickly transfer to other buildings. These
modifications are consistent with the Fire Authority having jurisdiction.
7.34.130 Section R313.2 Exception 1, Chapter R3 Automatic Fire Sprinkler Systems —
Amended.
Section R313.2 Exception is amended to read:
Exception: 1. Automatic residential fire sprinkler systems shall not be required for
additions or alterations to existing buildings that are not already provided with an automatic
residential sprinkler system, provided that the total square footage of the existing building plus
the addition does not exceed 3,600 square feet (334M2). Additions or alteration that remove 50
percent or more of the existing exterior walls of a dwelling shall be considered a new dwelling
for the purposes of Section R313.2.
FINDING: The amendment is needed due to local climatic and topographical
conditions.
This modification was necessary because the City of Dublin has a dry
period of at least five months each year. Additionally, The area is subject to
occasional drought. Because of dryness, a rapidly burning grass fire or
exterior building fire can quickly transfer to other buildings. These
modifications are consistent with the Fire Authority having iurisdiction.
7.34.140 Section R313.3, Chapter R3, including tables -deleted.
Section 17%313.3, including tables is deleted.
FINDING: The amendment is needed due to local climatic and topographical
conditions.
This modification was necessary because the City of Dublin has a dry
period of at least five months each year. Additionally, The area is subject to
occasional drought. Because of dryness, a rapidly burning grass fire or
exterior building fire can quickie transfer to other buildings. These
modifications are consistent with the Fire Authority having iurisdiction.
7.34.150 Section R319.2, Chapter R3, Site Address -Added.
Section R319.2, is added to read:
R319.2 Address Location. Address shall be installed in the following locations:
1. Walkway serving six (6) or more individual units where the front entrance is not parallel
to the street and driveways servicing six (6) or more individual dwellings units shall have
minimum of four (4) inch high identification numbers, noting the range of unit numbers
places at the entrance to each driveway at a height between thirty-six (36) and forty-two
Page 28 of 45
(42) inches about grade. The light source shall be provided with an uninterruptible AC
power source or controlled only by a photoelectric device or photovoltaic powered.
2. No other number may be affixed to a structure that might be mistaken for, or confused
with, the number assigned to the structure.
3. If the building is adjacent to an alley, the number shall also be placed on or adjacent to
the rear gate accessing the alley.
4. For multifamily buildings with recessed entryway over 2 feet, an additional lighted
address shall be placed at the entryway to the recessed area. If the recessed area
provides access to more than one dwelling unit, the range of units shall be displayed.
5. Each principal building of a multifamily complex shall display the number or letter
assigned to that building on each corner of the building at a height that will prevent the
number from being obscured by landscaping.
6. Any building with vehicular access to the rear through a public or private alley shall
display, in a clearly visible location, a highly reflective or illuminated address number a
minimum of four (4) inches in height.
7. Address numbers shall not be obstructed by architectural structures such as trellises,
arbors, balconies, light fixtures, and/or landscaping.
FINDINGS The amendment is needed due to local geological and topographical
conditions.
These modifications are necessary due to the topographical nature of the
City and the easy access to freeways described in Section A of these
Findings. In light of said conditions, it is necessary to adopt these
requirements to enhance crime prevention. Additionally, this will bring the
code into conformance with the City of Dublin Police Department
requirements.
7.34.160 Section 0337.1.1 Chapter 03, Scope —Amended.
Section R337.1.1 is amended to read:
0
337.1.1 Scope. This chapter applies to building materials, systems and/or assemblies
used in the exterior design and construction of new buildings located within a Wildland-
Urban Interface Fire Area as defined in Section R337.2 or adjacent to open space or
undeveloped land.
FINDING: The amendment is needed due to local climatic and topographical
conditions.
This modification was necessary because the City of Dublin has a dry
period of at least five months each year. Additionally, the area is subject to
occasional drought. Because of dryness, a rapidly burning grass fire or
exterior building fire can quickly transfer to other buildings. These
modifications are consistent with the Fire Authority having iurisdiction.
Page 29 of 45
7.34.170 Section R337.2 Chapter R3, Definitions — Amended.
Section 377.2 is amended to add the following definitions:
Adjacent to Open Space. Shall mean commercial parcels and residential lots which have a
point of contact with open space.
Adjacent to Undeveloped Land. Shall mean commercial parcels and residential lots which
have a point of contact with Undeveloped Land.
Open Space. For the purpose of this Chapter, Open Space shall mean those lands set aside to
remain permanently undeveloped.
Undeveloped Land. For the purpose of this Chapter, Undeveloped Land shall mean land
which is available for development, but no Tentative Map, Master Tentative Map or
Development Agreement has been approved, and any land designated for government use.
FINDING: The amendment is needed due to local climatic and topographical
conditions.
These modifications are necessary because the City of Dublin has a dry
period of at least five months each year. Additionaliv, The area is subiect to
occasional drought. Because of dryness, a rapidly burning grass fire or
exterior building fire can quickly transfer to other buildings. These
modifications are consistent with the Fire Authority having iurisdiction.
7.34.180 Section R350, Chapter R3, Building Security -Added
Section R350 is added to read:
R350.1 Residential building security shall be in accordance with the Uniform Building Security
Code in addition to the following:
R350.2 Exterior doors: Each exterior door shall be secured as follows:
1. Exterior doors (excluding glass patio doors) and doors leading from garage areas into
dwellings shall be equipped with a dead bolt lock with one -inch (1") throw.
2. Pairs of doors shall have flush bolts with a minimum throw of five -eighths inch (5/8") at
the head and foot (floor and ceiling) of the inactive leaf.
3. Doorstop on a wooden jamb for an in -swing door shall be of one-piece construction with
the jamb joined by a rabbit.
4. Locks shall be provided on all sliding patio doors.
5. Sliding patio glass doors opening onto patios or balconies which are less than one story
above grade or are otherwise accessible from the outside shall have the moveable
section of the door sliding on the inside of the fixed portion of the door or possess an
approved secondary lock mounted on interior of moveable section.
6. The lock bolt on all glass patio doors shall engage the strike sufficiently to prevent its
being disengaged by any possible movement of the door within the space or clearance
Page 30 of 45
provided for installation and operation. The strike area shall be of material adequate to
maintain effectiveness of bolt strength.
R350.3 Landscaping.
1. Shrubs and ground cover shall not directly cover windows and doorways.
2. River rock used near parking lots or buildings shall be permanently affixed.
3. Backyard gates shall be the full height of the wall or fence adjacent and capable of being
locked.
4. Open space and buildings shall be arranged to afford visibility and opportunity for
surveillance by on -site users and passers-by.
5. Barriers, both real and symbolic, shall be designed to afford opportunities for surveillance
through the barrier.
6. For residential development, walls or fences, if installed, shall be a minimum of 6 feet in
height when adjacent to any of the following:
• Reverse frontage,
• Retention/detention areas,
• Parks, Commercial areas,
• Industrial areas, or
• Bike paths.
R350.4 Garage Type (Vehicle) Doors. Garage -type doors, which are either rolling overhead,
solid overhead, swinging, sliding, or accordion style doors shall conform to the following
standards;
1. Wood doors shall have panels a minimum of five -sixteenths (5/16) inch in thickness with
the locking hardware being attached to the support framing.
2. Aluminum doors shall be a minimum thickness of
minimum of 18 inches on center
along the outside
0215 inches and riveted together a
main door structure
which shall meet the pilot, or
the strike area of the pilot or
3. Fiberglass doors shall have panels a minimum density of 6 ounces per square foot from
the bottom of the door to a height of 7 feet. Panels above 7 feet and panels in residential
structures shall have a density not less than 5 ounces per square foot.
4. Doors utilizing a cylinder lock shall have a lock receiving point at each outer edge of the
door; or if the door does not exceed 19 feet, a single bolt may be used if placed in the
center of the door with the locking point located either at the floor or door frame header.
5. Doors with slide bolt assemblies shall have frames a minimum of .120 inches of
thickness, with a minimum bolt diameter of one half (1/2) inch and protrude at least one
and one half (1 Y2) inches into the receiving guide. A bolt diameter of three -eighths (3/8)
inch may be used in a residential building. The slide bolt shall be attached to the door
Page 31 of 45
with non -removable bolts from the outside. Rivets shall not be used to attach slide bolt
assemblies.
R350.5 Emergency Access. Private roads and parking areas or structures controlled by
unmanned mechanical parking type gates shall provide for police emergency access as follows:
1. Radio frequency access or by providing the gate access code for distribution to
emergency responders. When an access code is to be utilized, an illuminated control
box shall be mounted on a control pedestal consisting of a metal post/pipe which shall be
installed at a height of 42 inches and a minimum of 15 feet (4.6m) from the entry/exit
gate. It shall be located on the driver's side of the road or driveway and accessible in
such a manner as to not require a person to exit their vehicle to reach it, nor to drive on
the wrong side of the road or driveway, nor to require any back-up movements in order to
enter/exit the gate.
2. All lockable pedestrian gates to residential recreation areas serving 6 or more dwelling
units, and gates or doors to common walkways or hallways of residential complexes
where there are 4 or more dwelling units within the complex, shall provide for police
emergency access utilizing an approved key switch device or approved Knox box.
3. Pedestrian gates/doors using an electromagnetic type lock shall install a key switch within
a telephone/intercom console or within a control housing, or other method approved by
the Building Official that will provide for police emergency access. See 350.5.1 for
options.
4. Pedestrian gates/doors (including pedestrian gates/doors in pool enclosures and
recreational facilities) utilizing mechanical locks shall install a Knox box adjacent to each
gate/door, securely attaching it to a fence or wall.
R350.6 Keying requirements. Upon occupancy by the owner or proprietor, each single unit in
a tract constructed under the same site development review, shall have locks using
combinations that are interchange free from locks used in all other separate dwellings,
proprietorships, or similar distinct occupancies.
R350.7 Other requirements
1. Storage Areas. Any exterior storage area attached to a dwelling enclosed by a door shall
comply with this section or have a minimum 3/8"diameter hardened padlock hasp.
2. Side Gates. Side gates shall be the full height of the adjacent fence or wall and be
capable of being locked. Side gates shall be secured with a slide bolt mounted on the
inside of the gate. The slide bolt shall have a bolt diameter of three -eighths (3/8) inch
and protrude at least one and one-half (1 Y2) inches into the receiving guide. The slide
bolt shall be attached to the gate with non -removable bolts. The slide bolt shall be
mounted at a height that is not accessible by reaching over the gate.
FINDINGS The amendment is needed due to local geological and topographical
conditions.
Page 32 of 45
This modification is necessary due to the topographical nature of the City
and the easy access to freeways described in Section A of these Findings.
In light of said conditions, it is necessary to adopt these requirements to
enhance crime prevention. Additionally, this will bring the code into
conformance with the City of Dublin Police Department requirements.
7.34.190 Section R403.1.3, Chapter R4, Footing and stem wall reinforcing in Seismic
Design Categories Do, Di, D2 — Amended.
Section R403.1.3 is amended to read:
R403.1.3 Footing and stem wall reinforcing in Seismic Design Categories Do, D�, Ds.
Concrete footings located in Seismic Design Categories Do, Di and D2, as established in Table
R301.2(1), shall have minimum reinforcement of at least two continuous longitudinal reinforcing
bars, one top and one bottom and not smaller than No. 4 bars. Bottom reinforcement shall be
located a minimum of 3 inches (76 mm) clear from the bottom of the footing.
FINDINGS: The amendment is needed due to local geological, climatic and
topographical conditions.
The San Francisco Bav Area region is densely populated and/or located in
an area of high seismic activities as indicated by United States Geological
Survey and California Division of Mines and Geology. Recent earthquake
activities, including the 1989 Loma Prieta earthquake, have indicated the
lack of adequate design and detailing as a contributing factor to damages
that reduced the protection of the life -safety of building occupants. The City
of Dublin is a densely populated area having buildings constructed near
potentially active faults. The Association of Bav Area Governments (ABAG)
roughly estimates the probability of a serious earthquake along the Hayward
Fault as one -in -four in the next 30 years, while the USGS predict the
probability of a powerful quake in the next 30 years at 72%. The proposed
modification to ensure that the design of slender wall must satisfy both
strength and serviceability requirements need to be incorporated into the
code to assure that new buildings and additions to existing buildings are
designed and constructed in accordance with the scope and objectives of
the International Building Code.
7.34.200 Table R602.10.3(3), Chapter R6, Bracing Requirements -Amended
Table R602.10.3(3) is amended by adding a new footnote "g" to read:
g. In Seismic Design Categories Do, D1, and D2, Method GB is not permitted and the use
of Method PCP is limited to one-story single-family dwellings and accessory structures.
Add the "g" footnote notation in the title of Table R602.10.3(3) to read:
TABLE R602.10.3(3)9
FINDINGS: The amendment is needed due to local geoloqical, climatic and
topographical conditions.
Page 33 of 45
This section deletes the use of aypsum board for lateral bracing. This
deletion is necessary because the City of Dublin is located in Seismic Zone
D and E. Gypsum wallboard has performed poorly during recent California
seismic events. The shear values for gypsum wallboard contained in the
code are based on mono -directional testing. In addition, this section limits
the use of Portland cement plaster for lateral bracing to sinale story
residential buildings. This limitation is necessary because the City of Dublin
is located in Seismic Zone D and E. Exterior Portland cement plaster has
performed poorly during recent California seismic events. The shear values
for Portland cement stucco contained in the code are based on mono -
directional testina. It is appropriate to limit the use of this product until
cyclic loading tests are performed and evaluated.
The San Francisco Bav Area region is densely populated and/or located in
an area of high seismic activities as indicated by United States Geological
Survey and California Division of Mines and Geology. Recent earthquake
activities, including the 1989 Loma Prieta earthquake, have indicated the
lack of adequate desian and detailina as a contributing factor to damaaes
that reduced the protection of the life -safety of building occupants. The City
of Dublin is a densely populated area havina buildinas constructed near
potentially active faults. The Association of Bay Area Governments (ABAG)
roughly estimates the probability of a serious earthquake along the Hayward
Fault as one -in -four in the next 30 years, while the USGS predict the
probability of a powerful quake in the next 30 years at 72%. The proposed
modification to ensure that the desian of slender wall must satisfy both
strength and serviceabilitv requirements need to be incorporated into the
code to assure that new buildings and additions to existina buildinas are
designed and constructed in accordance with the scope and obiectives of
the International Buildina Code.
7.34.210 Section R602.10.4.5, Chapter R6, Limits on methods GB and PCP —Added.
A new Section R602.10.4.5 is added to read:
R602.10.4.5 Limits on methods GB and PCP. In Seismic Design Categories Do, D�, and D2,
Method GB is not permitted for use as intermittent braced wall panels, but gypsum board is
permitted to be installed when required by this Section t i
be placed on the opposite side of the
FINDINGS: The amendment is needed due to local geological, climatic and
topographical conditions.
This section deletes the use of gvpsum board for lateral bracing. This
deletion is necessary because the City of Dublin is located in Seismic Zone
D and E. Gypsum wallboard has performed poorly during recent California
seismic events. The shear values for gypsum wallboard contained in the
code are based on mono -directional testing. In addition, this section limits
the use of Portland cement plaster for lateral bracina to single story
residential buildinas. This limitation is necessary because the City of Dublin
is located in Seismic Zone D and E. Exterior portland cement plaster has
Page 34 of 45
performed poorly during recent California seismic events. The shear values
for Portland cement stucco contained in the code are based on mono -
directional testing. It is appropriate to limit the use of this product until
cyclic loadina tests are performed and evaluated.
The San Francisco Bay Area region is densely populated and/or located in
an area of high seismic activities as indicated by United States Geological
Survey and California Division of Mines and Geology. Recent earthquake
activities, including the 1989 Loma Prieta earthquake, have indicated the
lack of adequate design and detailing as a contributing factor to damages
that reduced the protection of the life -safety of building occupants. The City
of Dublin is a densely populated area having buildings constructed near
potentially active faults. The Association of Bay Area Governments (ABAG)
roughly estimates the probability of a serious earthquake along the Hayward
Fault as one -in -four in the next 30 years, while the USGS predict the
probability of a powerful quake in the next 30 years at 72%. The proposed
modification to ensure that the design of slender wall must satisfy both
strength and serviceability requirements need to be incorporated into the
code to assure that new buildings and additions to existing buildings are
designed and constructed in accordance with the scope and objectives of
the International Building Code.
7.34.220 Section R902, Chapter 9, Roof Classification -Amended.
Section R902.1 is amended to read:
R902.1 Roof covering materials. Roofs shall be covered with materials as set forth in
Sections R904 and R905. Class A, B or C roofing shall be installed in areas as
designated below. Classes A, B and C roofing required by this section to be listed shall
be tested in accordance with UL 790 or ASTM E 108.
1. Map of Fire Safe Roof Areas. Figure 15-1 * is a map of Fire Safe Roof areas. Said
I ap may be amended from time to time by including areas which are annexed to
the City within one of the two roofing areas. Said amendments may be made by the
Building Official after consultation, with the Chief of the Fire Department or their
designee having jurisdiction.
2. Roofing Area 1. Any new roof and any alteration, repair or replacement for
buildings housing R & U-1 occupancies in Roofing Area 1 shall use roof covering
material that conforms to Class B or better or shall be made of concrete, ferrous or
copper metal, clay, slate or similar non-combustible material.
3. Roofing Area 2. Any new roof for buildings using roof covering material that
conforms to Class C or better or shall be made of concrete, ferrous or copper metal,
clay, slate or similar non-combustible material.
*Editor's Note: Figure 15-1 is on file in the office of the City Clerk.
FINDING: The amendment is needed due to local climatic and topographical
conditions.
Page 35 of 45
This modification was necessary because the City of Dublin has a dry
period of at least five months each year. Additionally, The area is subeect to
occasional drought. Because of dryness, a rapidly burning grass fire or
exterior building fire can quickly transfer to other buildings. These
modifications are consistent with the Fire Authority having jurisdiction.
7.34.230 Section R1001.1.2 Chapter 10, Prohibited Installations —Added.
A new Section R1001.1.2 is added to read:
R1001.1.2 Prohibited Installations. It shall be unlawful to install a new wood burning
fireplace or appliance that is not one of the following:
1. Pellet -fueled wood heater,
2. EPA certified wood heater,
3. Fireplace certified by EPA
FINDING: The amendment is needed due to local climatic and topographical
conditions.
This modification was necessary because fireplaces and wood stoves
generate 40 percent of the particulate matter in the Bay Area during the
winter months. Of greater concern are the fine particles, which can lodge
deep in the lungs causing permanent lung damage and increasing mortality.
Burning wood also generates carbon monoxide, nitrogen dioxide, volatile
organic and toxic air pollutants.
Page 36 of 45
4. California Electrical Code.
Section 7.36.070 DMC Section 210-53, Office receptacle outlets -Added.
Section 21 M3 is added to read:
210-53 Office Receptacle Outlets. In office buildings or offices exceeding ten (10)
percent of the floor area of the major use, receptacle outlets shall be installed in all
permanent walls or partitions of each office so that no point along the floor line any wall
space is more than six (6) feet (1.83m) measured horizontally, from an outlet in that
space including any wall space two (2) feet (610 mm) or more in width and the wall
space occupied by sliding panels in exterior walls.
As used in the section a "wall space" shall be considered a wall unbroken along the
floor line by doorways, fireplaces, and similar openings. Each wall space two (2) or
more feet (610 mm) wide shall be treated individually and separately from other wall
spaces within the room. A wall space shall be permitted to include two or more walls of
a room (around corners) where unbroken at the floor line.
As used in this section "office space" means an enclosed office space with hard walls.
Open office floor plans are not affected by this section.
Receptacle outlets shall, insofar as practicable be spaced equal distances apart.
Receptacle outlets in floors shall not be counted as part of the required number of
receptacle outlets unless located near the wall.
The receptacle outlets required by the section shall be in addition to any receptacle
that is part of any lighting fixture or appliance, located within cabinets or cupboards, or
located over five and one-half (5 Y2) feet (1.68 m) above the floor.
FINDINGS: The amendment is needed due to local geological conditions.
This section requires additional receptacles. The City of Dublin is located in
a highly active Seismic Zone D and E. In Office Bungs without these
requirements extension codes are being used. Extension cords are not
afforded the same protection from damage as wiring raceways. Damage to
extension cords could occur in a seismic event, which increases the
potential for a fire.
Page 37 of 45
5. California Plumbing Code.
Section 7.40.080 DMC Section 609.3, Chapter 6 uPC, under Concrete Slab —Amended.
Section 609.3, first paragraph, is amended by replacing it to read:
Section 609.3 Water piping shall not be installed in or under a concrete floor slab
within a building without prior approval of the Building Official. When approved,
such piping shall be installed in accordance with the following requirements.
FINDINGS The amendment is needed due to local geological conditions.
This section eliminates water piping in or under concrete floor slabs within a
building. This amendment is necessary for the following reasons.
(1) Most of the surface soils in the City of Dublin are relatively young and
unconsolidated sedimentary materials formed from a wide variety of parent
materials. The varying chemical composition, degree of weathering and the
relatively acid environment have created soils of varying types, which are
particularly corrosive in nature.
(2) Much of the surface soil in the City of Dublin is highly expansive (i.e., swell behavior) behavior) and have low bearing strength.
(3) There are two types of expansive soils in the area:
a. the organic silty clans which are the recent bay muds; and
b. the plastic silty clays which weather from the shale found in the hills
surrounding the City of Dublin
(4) The local climate is characterized by markedly delineated rainy and dry
seasons, which tend to maximize the expansive characteristics of soil.
(5) Some parts of the City of Dublin have hard water, which is corrosive to
ferrous pipe.
(6) The groundwater table is unusually high in many places.
(7) The City of Dublin is a highly active seismic area.
7.40.090 Section 612.1, Chapter 6, Where Required -Amended; Sections 612.2 through
612.7.2 and Tables 612.3.E through 612.5.3.2(9) —Deleted,
Section 612.1, is amended to read as follows:
612.1 Where Required. Where residential sprinklers systems are required in buildings,
these systems shall be installed per Chapter 9 of the California Building Code, Title 24
Part 2.
(Sections 612.2 through 612.7.2 and Tables 612.3 through 612.5.3.2(9) are Deleted.)
FINDING: The amendment is needed due to local climatic and topographical
conditions.
Page 38 of 45
This modification was necessary because the City of Dublin has a dry
period of at least five months each Year. Additionally, the area is subiect to
occasional drought. Because of dryness, a rapidly burning grass fire or
exterior building fire can quickly transfer to other buildings. These
modifications are consistent with the Fire Authority having iurisdiction.
Page 39 of 45
6. California Mechanical Code
No findings, beyond the general findings listed above, are necessary to justify the proposed
amendments
Page 40 of 45
7. Dublin Building Maintenance Code
7.48.080 Section 303.2, Chapter 3, Enclosures — Amended.
Section 303.2 is amended to read.
303.2 Enclosures. Private swimming pools, hot tubs, spas enclosure shall meet the
requirements of Section 3109.2 California Building Code, California Swimming Pool
Safety Act.
FINDING: The amendment is needed to correct a conflict with State Law.
7.48.100 Section 304.160 Chapter 3, Under -Floor areas —Amended.
Section 304.16 is amended to read:
304.16 Under -Floor areas. Under -floor access doors and ventilation openings shall be
maintained to prevent the entrance of rodents, rain and surface drainage water. Doors
shall be tight fitting and ventilation openings shall be properly screened with corrosion -
resistant wire mesh having openings not exceeding 1/4 inch in any dimension or alternate
approved materials pursuant to current CBC 1203.4.1.
FINDING: The amendment is needed due to local climatic and topographical
conditions.
This modification was necessary because the City of Dublin has a dry
period of at least five months each year. Additionally, the area is subject to
occasional drought. Because of the dryness and drought rodents may
enter homes in search of water and shade.
7.48.110 Sections 308.2.1.1, Chapter 3, Garbage Receptacles —Added.
Section 308.2.1.1 is adding to read:
308.2.1.1 Garbage Receptacles. An adequate number of appropriate receptacles with
close fitting covers for garbage and rubbish as may be considered necessary by the
enforcing agency shall be provided for the occupant of every dwelling unit by the owner
or operator of every apartment house, hotel, or combination thereof. Each receptacle
shall be kept in a clean condition and good repair.
FINDING: The amendment is needed due to local climatic and topographical
conditions.
This modification was necessary because the City of Dublin has a dry
period of at least five months each year. Additionally, the area is subject to
occasional drought. Because of the dryness and drought rodents may
enter homes in search of water and shade.
7.48.120 Sections 309.1 and 309.2, Chapter 3, Pest Elimination —Amended.
Sections 309.1 and 309.2 are amended to read:
309.1 Infestation. All structures shall be kept free from insect, rodent and vermin
infestation. When an insect, rodent or vermin infestation is brought to the attention of the
code official, he or she may require the owner or agent having charge or control of the
Page 41 of 45
building, lot or premise to hire a licensed exterminator or other qualified professional to
inspect the building, lot or premise and provide a written report verifying the presence
and severity of such infestation including in the report a recommendation for proper
extermination of the infestation. All structures in which insect, rodent or vermin
infestations are found shall be promptly exterminated by approved processes that will not
be injurious to human health. After the extermination of the infestation is complete, the
code official may request a written notice from the licensed exterminator or other qualified
professional attesting to the completion and success of the recommended extermination
procedures. After the infestation is eliminated, proper precautions shall be taken to
prevent reinfestation.
309.2 Owner. The owner of any structure shall be responsible for extermination within
the structure prior to renting or leasing the structure. The owner of a structure or premise
containing a dwelling unit, multiple occupancy, rooming house or a nonresidential
structure shall be responsible for maintaining the structure and premise in a rodent or
pest -free condition. If an infestation is caused by an occupant substantially failing to
properly maintain their occupied area of the structure or premise as clean and sanitary as
the condition of the structure or premise permits, the occupant and owner shall be
responsible for pest elimination. For as long as the occupant's failure either substantially
causes an unlivable condition to occur, or substantially interferes with the owners' ability
to remedy the condition, the owner does not have to remedy the condition. Where the
infestation is caused by defects in the structure, the owner shall be responsible for
extermination.
FINDING: The amendment is needed due to local climatic and topographical
conditions.
This modification was necessary because the City of Dublin has a dry
period of at least five months each year. Additionally, the area is subiect to
occasional drought. Because of the dryness and drought rodents may
enter homes in search of water and shade.
Page 42 of 45
8. California Green Building Code
7.94.050 Section A4.106.8 Electric vehicle (EV) charging for new construction —
Adopted
Section A4.106.8 is adopted
Section A4.106.8 Electric vehicle (EV) charging for new construction is adopted as
mandatory at the Tier 2 level.
FINDINGS The amendment is needed due to local climatic, topographical and
environmental conditions.
This modification is necessary because the City of Dublin is a densely
populated area havina buildings and structures constructed within heavily
traveled traffic corridors and hiahways (580 and 680), near and within flood
prone areas. This impacts the quality of the air, causes higher decibel
noise level, and increases the risk of rising sea or flood levels. The
proposed modification to increase the number of EV charaina spaces will
help to address and significantly reduce local air and noise pollutions,
green house gas emissions, and will improve the health and welfare of the
City's residents, businesses and visitors and reduce the rise in sea or
flood levels that could put at risk the City's homes, businesses and public
facilities at risk. Therefore, this amendment needs to be incorporated into
the code to assure that new buildings and structures and additions or
aIterations to existing buildings or structures are designed and
constructed in accordance with the scope and obiectives of the California
Green Buildina Standards Code.
7.94.060 SectionDivision 4.1, Chapter 4, Future access for solar systems -
Added.
A new Section 4.107.1 is added to read:
4.107.1 Future Access for Solar Systems. A minimum one -inch (25.4 mm) electrical
conduit shall be provided from the electrical service equipment to an accessible location
within the solar zone as defined by the California Energy Code, Title 24 Part 6 Section
110.10 or other location approved by the Building Official.
Exception: Where solar is installed as part of the original construction and prior to first
occupancy.
FINDINGS The amendment is needed due to local climatic, topographical and
environmental conditions.
Green building design, construction and operation can have a significant
positive effect on energy resource efficiency, waste and pollution
generation, and the health and productivity of building occupants over the
life of the buildina. The City of Dublin has a dry, hot period of at least five
months each year. As a result of the high temperatures, average load
demand and peak load demand of enerav used in Dublin are important
factors impacting public safety and creatina the potential for adverse
economic impacts due to power outaaes or power reductions (i.e.
Page 43 of 45
"brownouts"), Reduction of total and peak energy use as a result of
incremental conservation measures required by this ordinance will have
local benefits in the additional available system energy capacity.
7.94.070 Table 5.106.5.3.3 - Deleted and Replaced
Table 5.106.5.3.3 is deleted and replaced:
Table 5.106.5.3.3 is deleted and replaced with Table A5.106.5.3.2
FINDINGS The amendment is needed due to local climatic, topographical and
environmental conditions.
This modification is necessary because the City of Dublin is a densely
populated area having buildings and structures constructed within heavily
traveled traffic corridors and highways, near and within flood prone areas.
his impacts the quality of the air, causes higher decibel noise level, and
increases the risk of rising sea or flood levels. The proposed modification
to increase the number of EV charging spaces will help to address and
sgnificantly reduce local air and noise pollutions, green house has
emissions, and will improve the health and welfare of the City's residents,
businesses and visitors and reduce the rise in sea or flood levels that
could put at risk the City's homes, businesses and public facilities at risk.
Therefore, this amendment needs to be incorporated into the code to
assure that new buildings and structures and additions or alterations to
existing buildings or structures are designed and constructed in
accordance with the scope and objectives of the California Green Building
Standards Code.
7.94.080 SectionDivision 5.1, Chapter 5, Future access for solar systems
-
Added.
A new Section 5.107.1 is added to read:
5.107.1 Future Access for Solar Systems. Install conduit from the solar zone as defined
by the California Energy Code, Title 24 Part 6 Section 110.10 to a location within the building
identified as suitable for future installation of a charge controller (regulator) and inverter.
Exception: Where solar is installed as part of the original construction and prior to first
occupancy.
FINDINGS The amendment is needed due to local climatic, topographical and
environmental conditions.
Green building design, construction and oaeration can have a significant
positive effect on energy resource efficiency, waste and pollution
generation, and the health and productivity of building occupants over the
life of the building. The City of Dublin has a dry, hot period of at least five
months each year. As a result of the high temperatures, average load
demand and peak load demand of energy used in Dublin are important
factors impacting public safety and creating the potential for adverse
economic impacts due to power outages or power reductions (i.e.
"brownouts"). Reduction of total and peak energy use as a result of
Page 44 of 45
incremental conservation measures required by this ordinance will have
local benefits in the additional available system energy capacity.
Page 45 of 45