HomeMy WebLinkAbout5.1 Randeri Commercial Building (PLPA-2018-00007)Page 1 of 6
STAFF REPORT
PLANNING COMMISSION
DATE: January 28, 2020
TO: Planning Commission
SUBJECT:
PUBLIC HEARING: Randeri Commercial Building (PLPA-2018-00007)
Prepared by:Anne Wong, AICP, Assistant Planner
EXECUTIVE SUMMARY:
The Applicant and Property Owner, Chetan Randeri, has requested approval of a Site
Development Review Permit for the construction of a 3,578 -square-foot multi-tenant
commercial building and related site improvements on a vacant property located at
7400 Amador Valley Boulevard. The proposal includes the one-story commercial
building, sidewalk and frontage improvements, landscaping and a parking area at the
rear of the parcel. It is anticipated that the three tenant spaces will be occupied with a
mix of office and retail uses.
RECOMMENDATION:
Conduct the public hearing, deliberate and adopt a Resolution approving a Site
Development Review Permit for the construction of a 3,578-square-foot commercial
building and related site improvements at 7400 Amador Valley Boulevard.
DESCRIPTION:
Background
The subject property is located within the Village Parkway District of the Downtown
Dublin Specific Plan and has a General Plan land use designation of Downtown Dublin-
Village Parkway District. This designation allows a range of residential, commercial, and
mixed uses consistent with the Downtown Dublin Specific Plan.
Project Site
The project site is a rectangular shaped parcel located at 7400 Amador Valley
Boulevard near Village Parkway as shown in Figure 1. The subject property is 1 1,703
square feet and currently vacant and undeveloped. The property is one of three parcels
on this block of Amador Valley Boulevard between I -680 and Village Parkway. A multi-
tenant commercial building is located to the west and an automobile service cen ter and
car wash is located to the east.
5.1
Packet Pg. 8
Page 2 of 6
Figure 1: Project Vicinity
Proposed Project
The Applicant is requesting approval of a Site Development Review Permit to construct
a 3,578-square-foot multi-tenant commercial building and related site improvements.
Tenants have not been identified for the building; however, it is anticipated that the
three tenant spaces would be occupied with a mix of commercial uses. The layout of the
building provides for pedestrian access directly from Amador Valley Boule vard. The
proposed site plan is shown in Figure 2 below. The proposal includes the one -story
commercial building and related site improvements including sidewalk and frontage
improvements, landscaping, a drainage retention area, new trash enclosure and par king
at the rear of the parcel. The parking area, which would accommodate 12 parking
spaces, would be accessed through an existing easement from Village Parkway. The
site can also be accessed from Amador Valley Boulevard through the adjacent parking
lot to the west.
5.1
Packet Pg. 9
Page 3 of 6
Figure 2: Proposed Site Plan
ANALYSIS:
The Zoning Ordinance requires a Site Development Review Permit for the construction
of new principle structures. Approval of a Site Development Review Permit is subject to
findings related to policy compliance, including General Plan policies, consistency with
zoning, physical suitability of the site, impacts to general safety and welfare, site layout,
impacts to views, impacts to topography, architectural considerations, landscape
considerations and adequate circulation as shown in the draft resolution included as
Attachment 1.
Site Plan
The subject parcel is relatively long and narrow measuring approximately 55 feet wide
by 100 feet deep. The proposed building would front along Amador Valley Boul evard
with parking in the rear of the building. Site topography and the proposed orientation of
the building would provide for pedestrian access from Amador Valley Boulevard and
vehicular access from Village Parkway via an existing easement. The street fro ntage
would be enhanced with new landscaping and sidewalk improvements on Amador
Valley Boulevard for visual appeal. The existing driveway apron would be removed and
replaced with a landscape strip and sidewalk to match the adjacent existing condition.
Concrete pavers and additional landscaping are proposed between the sidewalk and
the building extending the public space and connecting the front entries to the street.
The proposed trash enclosure would be discretely located at the rear of the property
and screened with shrubs on three sides. Bicycle racks are proposed at the east and
west side of the parcel, adjacent to the building. A long -term bicycle locker is proposed
at the west side of the parcel, adjacent to the building. The site layout would impleme nt
the vision of the Downtown Dublin Specific Plan and create a walkable environment by
incorporating pedestrian-scale improvements including the size, mass, design and
orientation of the building and sidewalk and landscaping enhancements. The proposed
site plan, floor plan, elevations, and landscape plans are shown in the Project Plans
5.1
Packet Pg. 10
Page 4 of 6
provided in Attachment 2 (Exhibit A of Attachment 1).
Architecture
The architectural vision for the Village Parkway District as outlined in the Downtown
Dublin Specific Plan is that “Village Parkway will be a pedestrian -oriented district that
also accommodates through traffic. Buildings will be sited at or near the sidewalk with
parking provided at the rear to encourage walking and create a more consistent street
edge.” In addition, buildings must complement the existing uses with designs that are
compatible with adjacent structures and the district as a whole and use high -quality,
durable, attractive and long-lasting materials. The project’s architectural design and
material palette would be consistent with this vision.
The architectural concept for the development is traditional with a flat roof of varying
heights. The architecture would compliment the adjacent buildings and the size of the
parcel. The building would follow the angle of the street by stepping back the front
building wall in line with the street. The building form would be highlighted with the use
of stucco molding parapets, grey stone trim, limestone cornices above entrances,
charcoal canvas fabric awnings, bronze anodized aluminum storefront glazing,
limestone wall base wainscoting and exterior light fixtures. The front elevation is shown
in Figure 3.
Figure 3: Proposed Front Elevation
A color elevation that illustrates the variety of colors and materials for the buildings is on
Sheet 16 of the Project Plans (Attachment 2). A colors and materials board (Exhibit B to
Attachment 1) will be presented at the Planning Commission meeting for review and
consideration.
5.1
Packet Pg. 11
Page 5 of 6
Landscaping
The landscape palette and layout have been designed to be consistent with the
Downtown Dublin Specific Plan by utilizing enhanced hardscape and a variety of plant
materials. The overall landscape concept is on Sheet L1 of the Project Plans
(Attachment 2).
The preliminary landscape plan shows the installation of new landscaping in the parking
lot and around the building. Two existing Raywood ash street trees along Amador
Valley Boulevard would remain and three new Raywood ash trees would be added to
the street frontage to accommodate the sidewalk widening with pavers at the subject
property. A condition of approval has been included requiring a tree protection plan to
ensure the mature Raywood ash trees would be protected during project construction.
The preliminary landscape plan includes a conceptual plant pallet with 36-inch box
Raywood ash trees along Amador Valley Boulevard, 24-inch box evergreen pear trees
and a mix of five-gallon shrubs, one-gallon vines, grasses, perennials and ground cover.
The total site area for landscaping is approximately 1,710 square feet and all
landscaped areas would be drip irrigated and consists of only drought resistant plants
suitable for low maintenance and water conserving efforts. A drainage retention area
planter is located on the southeast corner of the site.
Access, Circulation, and Parking
The site is currently accessible from Amador Valley Boulevard and through an existing
easement from Village Parkway. The proposal would eliminate the existing driveway
apron on Amador Valley Boulevard and primary vehicular access to the project site and
parking area would be provided through the easement from Village Parkway. The
easement begins on Village Parkway and runs along the south of parcel to the rear of
the project site. Secondary access from Amador Valley Boulevard is available through
the parking lot for the adjacent commercial building to the west.
New buildings constructed in the Village Parkway District are required to provide
parking spaces at the rate of one space per 300 square feet of gross building area,
regardless of the future commercial use of the building. The proposed 3,578 -square-foot
building requires 12 on-site parking spaces as shown on the Project Plans.
Public Art Compliance
The Applicant has elected to provide public art on the project site. The Applicant is
proposing to locate public art near the street and building entrance to ensure it would be
accessible to the public as shown on Sheet L1 of the Project Plans (Attachment 2). The
installation and location would be subject to review by the Heritage and Cultural Arts
Commission and approval by the City Council.
ENVIRONMENTAL REVIEW:
The proposed Project is exempt from the requirements of the California Environmental
Quality Act (CEQA) pursuant to CEQA Guidelines Section 15303 (New Construction or
5.1
Packet Pg. 12
Page 6 of 6
Conversion of Small Structures) as the new commercial building would not exceed
10,000 square feet within an urbanized area qualifying it for this exemption.
CONSISTENCY WITH THE GENERAL PLAN, AND ZONING ORDINANCE:
The General Plan land use designation is Downtown Dublin - Village Parkway District.
The proposed commercial building is permitted within the Downtown Dublin Specific
Plan Village Parkway District and would be consistent with the applicable Development
Regulations as described in the Downtown Dublin Specific Plan and Dublin Municipal
Code. The proposed building size and configuration would not exceed the allowable
building area or create adverse conditions on -site or for surrounding properties but
would enhance the surrounding and expand commercial options in the area. The
proposed project would be consistent with the Downtown Dublin Specific Plan and the
vision for the Village Parkway District.
REVIEW BY APPLICABLE DEPARTMENT AND AGENCIES:
The Building Division, Fire Prevention Bureau, Public Works Department, and Dublin
San Ramon Services District have reviewed the project and provided Conditions of
Approval (Attachment 1) where appropriate to ensure the project is established in
compliance with all local ordinances and regulations.
NOTICING REQUIREMENTS/PUBLIC OUTREACH:
In accordance with the City’s policy, the Applicant installed a Planning Application
Notice Sign along the project frontage. The sign includes details about the project and
how to find out more information. The project is also included on the City’s Development
Activity webpage.
In accordance with State law, a public hearing notice was published in the East Bay
Times and posted at several locations throughout the City . A notice of this public
hearing was mailed to all property owners and tenants within 300 feet of the project site.
Notices were also mailed to interested parties. A copy of the Staff Report was provided
to the Applicant and posted to the City’s website.
ATTACHMENTS:
1. Planning Commission Resolution approving a Site Development Review Permit for
the Randeri Commercial Building
2. Exhibit A to Attachment 1: Project Plans
5.1
Packet Pg. 13
RESOLUTION NO. 20-xx
A RESOLUTION OF THE PLANNING COMMISSION
OF THE CITY OF DUBLIN
APPROVING A SITE DEVELOPMENT REVIEW PERMIT FOR THE CONSTRUCTION OF A
3,578 SQUARE FOOT COMMERCIAL BUILDING AT 7400 AMADOR VALLEY BOULEVARD
(APN 941-0210-001-04)
PLPA-2018-00007
WHEREAS, the Applicant and Property Owner, Chetan Randeri, is requesting approval to
construct a 3,578-square-foot commercial building on an undeveloped 11,073-square-foot site
located at 7400 Amador Valley Boulevard; and
WHEREAS, the project site is located within the Village Parkway District of the Downtown
Specific Plan and the General Plan land use designation of Downtown Dublin-Village Parkway
District; and
WHEREAS, the Project Plans illustrate the site layout and building elevations for the
construction of 3,578-square-foot commercial building which is permitted by the Downtown Dublin
Specific Plan and Zoning Ordinance with the submission of a Site Development Review Permit
within this zoning district; and
WHEREAS, the California Environmental Quality Act (CEQA) together with state
guidelines and Dublin’s CEQA guidelines require that certain projects be reviewed for
environmental impacts and when applicable, environmental documents prepared; and
WHEREAS, the proposed project is exempt from the requirements of the California
Environmental Quality Act (CEQA) pursuant to CEQA Guidelines Section 15303 (New
Construction or Conversion of Small Structures) as the new commercial building would not exceed
10,000 square feet within an urbanized area qualifying it for this exemption ; and
WHEREAS, the Site Development Review Project Plan Set, attached as Exhibit A to this
Resolution illustrates the proposed site layout, building architecture, parking, circulation, access
to public streets, frontage improvements, and landscaping for the proposed project; and
WHEREAS, a Staff Report dated January 28, 2020, was submitted recommending that the
Planning Commission approve a Site Development Review Permit for the proposed project; and
WHEREAS, on January 28, 2020, the Planning Commission held a public hearing on the
project at which time all interested parties had the opportunity to be heard; and
WHEREAS, proper notice of said public hearing was given in all respects as required by
law; and
WHEREAS, the Planning Commission did hear and use independent judgment and
considered all said reports, recommendations, and testimony hereinabove set forth.
NOW, THEREFORE, BE IT RESOLVED that the foregoing recitals are true and correct
and made a part of this resolution.
5.1.a
Packet Pg. 14 Attachment: 1. Planning Commission Resolution approving a Site Development Review Permit for the Randeri Commercial Building (Randeri
2
BE IT FURTHER RESOLVED that the Planning Commission of the City of Dublin hereby
makes the following findings and determinations regarding the proposed Site Development
Review Permit to construct a 3,578-square-foot commercial building on an undeveloped 11,073-
square-foot site located at 7400 Amador Valley Boulevard:
A. The proposal is consistent with the purposes of Chapter 8 .104 of the Zoning Ordinance,
General Plan and any applicable Specific Plans and design guidelines in that: 1) the
project consists of the construction of a new 3,578-square-foot one-story commercial
building which is consistent with the scale of the neighborho od and community; 2) the
project is well designed in relation to the surrounding properties which preserves the
architectural character and scale of the neighborhood and the community because the
design, character, height, façade length, size, mass, colors, materials, and architectural
details are compatible with the existing structures in the vicinity; 3) the project enhances
the site and surrounding areas and is harmonious with high standards of improvements
because the building location, on-site circulation, parking and landscaping meet
development standards and are designed in an appropriate manner; 4) the project
complies with development regulations and the requirements of the Downtown Dublin
Zoning District; 5) the project complies with the Downtown Dublin Specific Plan
Development Standards and Design Guidelines for the Village Parkway District which
include lot width, lot depth, lot size, setbacks, frontage buildout , building entrance
access, pedestrian access, vehicular access, driveway width , surface parking location,
parking requirements, floor area ratio, building height and architectural standards; 6)
the project promotes the health, safety and general welfare as the commercial building
will be structurally safe and is a site improvement that is visible to the general public; 7)
the project provides adequate circulation for automobiles as well as pedestrians and
bicyclists to create a pedestrian-friendly environment because pedestrian access to the
site can be obtained from the existing sidewalk along Amador Valley Boulevard and
vehicular access can be obtained from an existing easement that provides access from
Village Parkway; 8) the project supports retail and commercial uses in the Downtown
which is consistent with the General Plan land use designation of Downtown Dublin-
Village Parkway District; and 9) the site layout implements the vision of the Downtown
Specific Plan Design Guidelines as it creates a walkable environment by incorporating
a pedestrian-scale building and site that accommodates traffic and the building is sited
adjacent to the sidewalk with parking provided at the rear to encourage walking and
create a more consistent street edge.
B. The proposal is consistent with the provisions of Title 8, Zoning Ordinance in that: 1)
zoning for the site is Downtown Dublin zoning district and the proposed use of the
building is anticipated to be a mix of office and retail uses which are permitted uses in
the Village Parkway District; 2) a Site Development Review Permit by the Planning
Commission is required for the new construction of principal structures in the Downtown
Dublin Zoning District and the Applicant has submitted a complete Site Development
Review Permit application; 3) the project complies with the Downtown Dublin Specific
Plan Development Standards and Design Guidelines for the Village Parkway District
which include lot width, lot depth, lot size, setbacks, frontage buildout, building entrance
access, pedestrian access, vehicular access, driveway width , surface parking location,
parking requirements, floor area ratio, building height and architectural standards; and
4) the project provides high-quality design, architecture, materials and landscaping and
contributes to an orderly, attractive, and harmonious site and structural development,
compatible with the intended commercial uses, and surrounding properties in this
zoning district.
5.1.a
Packet Pg. 15 Attachment: 1. Planning Commission Resolution approving a Site Development Review Permit for the Randeri Commercial Building (Randeri
3
C. The design of the project is appropriate to the City, the vicinity, surrounding properties,
and the lot in which the project is proposed in that: 1) the project complies with the
Downtown Dublin Specific Plan Development Standards and Design Guidelines for the
Village Parkway District which include lot width, lot depth, lot size, setbacks, frontage
buildout, building entrance access, pedestrian access, vehicular access, driveway
width, surface parking location, parking requirements, floor area ratio, building height
and architectural standards; 2) the site layout implements the vision of the Downtown
Specific Plan Design Guidelines as it creates a walkable environment by incorporating
a pedestrian-scale building and site that accommodates traffic and the building is sited
adjacent to the sidewalk with parking provided at the rear to encourage walking and
create a more consistent street edge; 3) the project includes construction of a new
structure, sidewalk improvements, landscaping; bike rack installation, and a parking lot
at the rear of the parcel which will result in an interesting, attractive and high -quality
design that is compatible with the intended community retail and commercial uses and
surrounding properties in this zoning district, will enhance the site and surrounding
areas and will be harmonious with high standards of improvements; 4) the project i s
designed to be compatible with surrounding structures in terms of design, colors,
materials, size, and mass; and 5) the project is consistent with and complimentary to
the surrounding commercial businesses, provides additional active development in an
existing commercial district that can support the intended community retail and
commercial uses and will expand the commercial opportunities in this area.
D. The subject site is suitable for the type and intensity of the approved development in
that: 1) the project is an infill development within the Downtown Dublin zoning district-
Village Parkway, will have a mix of office and retail uses and is surrounded by other
commercial uses and, therefore, suitable and compatible with the surrounding; 2) the
project is consistent with and complimentary to surrounding commercial businesses,
provides additional active development in an existing commercial district that can
support the intended community retail and commercial uses and will expand the
commercial opportunities in this area; 3) the project site will be fully served by a network
of infrastructure of public roadways, services, and facilities; 4) the project complies with
the Downtown Dublin Specific Plan Development Standards and Design Guidelines for
the Village Parkway District and, thus, would not create adverse conditions on-site or
for surrounding properties; and 5) the project is designed to be compatible with
surrounding structures in terms of design, colors, materials, size and mass.
E. Impacts to existing slopes and topographic features are addressed in that: 1) the project
site is generally flat; and 2) landscaping and pavement along the street frontage and
throughout the project will be completed.
F. Architectural considerations including the character, scale and quality of the design, site
layout, the architectural relationship with the site and other buildings, screening of
unsightly uses, lighting, building materials and colors and similar elements result in a
project that is harmonious with its surroundings and compatible with other
developments in the vicinity in that: 1) the project consists of the construction of a new
3,578-square-foot one-story commercial building which is consistent with the scale of
the neighborhood and community; 2) the design of the building includes a neutral paint
palette with galvanized stucco molding parapets that are at varying heights, grey stone
trim, limestone cornices above entrances, charcoal canvas awnings, bronze anodized
aluminum storefront glazing, limestone wall base and exterior light fixtures with
5.1.a
Packet Pg. 16 Attachment: 1. Planning Commission Resolution approving a Site Development Review Permit for the Randeri Commercial Building (Randeri
4
landscaping and parking area improvements which are well designed in relation to the
surrounding properties that preserves the architectural character and scale of the
neighborhood and the community because the design, character, height, façade length,
size, mass, colors, materials, and architectural details are compatible with the existing
structures in the vicinity; 3) the new building, sidewalk improvements, landscaping, bike
rack installation and a parking lot at the rear of the parcel which will result in an
interesting, attractive and high-quality design that is compatible with the intended
community retail and commercial uses and surrounding properties in this zoning district,
will enhance the site and surrounding areas and will be harmonious with high standards
of improvements; and 4) the project complies with the Downtown Dublin Specific Plan
Development Standards and Design Guidelines for the Village Parkway District which
include lot width, lot depth, lot size, setbacks, frontage buildout , building entrance
access, pedestrian access, vehicular access, driveway width , surface parking location,
parking requirements, floor area ratio, building height and archite ctural standards.
G. Landscape considerations, including the location, type, size, color, texture and
coverage of plant materials, and similar elements have been incorporated into the
project to ensure visual relief, adequate screening and an attractive environment for the
public in that: 1) the landscaping, hardscape and amenities are designed in a
contemporary style to complement the architecture of the building; and 2) the project is
also required to conform to the requirements of the City’s Water Efficient Landscape
Ordinance, which is demonstrated and secured by the conditions of approval.
H. The site has been adequately designed to ensure the proper circulation for bicyclist,
pedestrians, and automobiles in that: 1) the proposed layout of the parking lot area has
been reviewed for safety and adequate circulation; 2) development of this project will
integrate into the existing circulation and development pattern of the larger area; and
3) pedestrian access to the site can be obtained from the existing sidewalk along
Amador Valley Boulevard and vehicular access can be obtained from an existing
easement that provides access from Village Parkway.
BE IT FURTHER RESOLVED that the Planning Commission of the City of Dublin hereby
approves the Site Development Review Permit to construct a 3,578 -square-foot commercial
building on an undeveloped 11,073-square-foot site located at 7400 Amador Valley Boulevard,
subject to the following conditions:
CONDITIONS OF APPROVAL:
Unless stated otherwise, all Conditions of Approval shall be complied with prior to the issuance of
building permits or establishment of use and shall be subject to Planning Division review and
approval. The following codes represent those departments/agencies responsible for monitoring
compliance of the conditions of approval. [PL.] Planning, [B] Building, [PO] Police, [PW] Public
Works [P&CS] Parks & Community Services, [ADM] Administration/City Attorney, [FIN] Finance,
[F] Alameda County Fire Department, [DSR] Dublin San Ramon Services District, [CO] Alameda
County Department of Environmental Health, [Z7] Zone 7.
# CONDITION TEXT RESPON.
AGENCY
WHEN REQ’D
Prior to:
PLANNING
1. Approval. This Site Development Review Permit approval
is for the construction of a 3,578-square-foot commercial
PL Ongoing
5.1.a
Packet Pg. 17 Attachment: 1. Planning Commission Resolution approving a Site Development Review Permit for the Randeri Commercial Building (Randeri
5
# CONDITION TEXT RESPON.
AGENCY
WHEN REQ’D
Prior to:
building and related site improvements on an undeveloped
11,073-square-foot site located at 7400 Amador Valley
Boulevard (PLPA-2018-00007). This Site Development
Review Permit shall generally conform to the project plans
attached to this Resolution as Exhibit A, received December
13, 2019, prepared by Beaumont and Associates, and
consisting of 16 sheets, materials and color board attached
to this Resolution as Exhibit B, received December 13,
2019, and other plans, text, and diagrams relating to this
application, stamped approved and on file in the Community
Development Department, except as modified by the
Conditions of Approval contained herein.
2. Effective Date. This Site Development Review Permit
approval becomes effective 10 days following action by the
Planning Commission unless appealed before that time in
accordance with the Dublin Zoning Ordinance to the City
Council.
PL Ongoing
3. Permit Expiration. Construction or use shall commence
within one (1) year of approval or the Site Development
Review Permit shall lapse and become null and void.
PL One Year After
Effective Date
4. Time Extension. The Community Development Director
may grant a time extension, upon the Applicant’s written
request for an extension of approval prior to expiration,
upon the determination that all Conditions of Approval
remain adequate and all applicable findings of approval will
continue to be met in accordance with Chapter 8.96 of the
Dublin Zoning Ordinance.
PL Expiration Date
5. Compliance. The Applicant shall operate this use in
compliance with the Conditions of Approval of this Site
Development Review Permit, the approved plans and the
regulations established in the Zoning Ordinance. Any
violation of the terms or conditions specified may be subject
to enforcement action.
PL On-going
6. Revocation of Permit. The Site Development Review
Permit approval shall be revocable for cause in accordance
with Section 8.96.020.I of the Dublin Zoning Ordinance.
Any violation of the terms or conditions of this permit shall
be subject to citation.
PL On-going
7. Requirements and Standard Conditions. The Applicant
shall comply with applicable City of Dublin Fire Prevention
Bureau, Dublin Public Works Department, Dublin Building
Division, Dublin Police Services, Alameda County Flood
Control District Zone 7, Livermore Amador Valley Transit
Authority, Alameda County Public and Environmental
Health, Dublin San Ramon Services District and the
California Department of Health Services requirements and
standard conditions. Prior to issuance of building permits or
the installation of any improvements related to this project,
the Applicant shall supply written statements from each
Various Building Permit
5.1.a
Packet Pg. 18 Attachment: 1. Planning Commission Resolution approving a Site Development Review Permit for the Randeri Commercial Building (Randeri
6
# CONDITION TEXT RESPON.
AGENCY
WHEN REQ’D
Prior to:
such agency or department to the Community Development
Department, indicating that all applicable conditions
required have been or will be met.
8. Required Permits. The Applicant shall obtain all permits
required by other agencies including, but not limited to
Alameda County Flood Control and Water Conservation
District Zone 7, California Department of Fish and Wildlife,
Army Corps of Engineers, Regional Water Quality Control
Board, Caltrans and provide copies of the permits to the
Public Works Department.
PW Building Permit
Issuance and
Grading Permit
Issuance
9. Fees. The Applicant shall pay all applicable fees in effect
at the time of building permit issuance, including, but not
limited to, Planning fees, Building fees, Traffic Impact Fees,
TVTC fees, Dublin San Ramon Services District fees,
Public Facilities fees, Dublin Unified School District School
Impact fees, Fire Facilities Impact fees, Alameda County
Flood and Water Conservation District (Zone 7) Drainage
and Water Connection fees; or any other fee that may be
adopted and applicable.
Various Building Permit
Issuance
10. Indemnification. The Applicant shall defend, indemnify,
and hold harmless the City of Dublin and its agents, officers,
and employees from any claim, action, or proceeding
against the City of Dublin or its agents, officers, or
employees to attack, set aside, void, or annul an a pproval
of the City of Dublin or its advisory agency, appeal board,
Planning Commission, City Council, Community
Development Director, Zoning Administrator, or any other
department, committee, or agency of the City to the extent
such actions are brought within the time period required by
Government Code Section 66499.37 or other applicable
law; provided, however, that the Applicant's duty to so
defend, indemnify, and hold harmless shall be subject to the
City's promptly notifying the Applicant of any said claim,
action, or proceeding and the City's full cooperation in the
defense of such actions or proceedings.
ADM On-going
11. Clarification of Conditions of Approval. In the event that
there needs to be clarification to the Conditions of Approval,
the Community Development Director and the Public Works
Director have the authority to clarify the intent of these
Conditions of Approval to the Applicant without going to a
public hearing. The Community Development Director has
the authority to make minor modifications to these
conditions without going to a public hearing in order for the
Applicant to fulfill needed improvements or mitigations
resulting from impacts to this project.
Various On-going
12. Clean-up. The Applicant shall be responsible for clean-up
and disposal of project related trash to maintain a safe,
clean and litter-free site.
PL On-going
5.1.a
Packet Pg. 19 Attachment: 1. Planning Commission Resolution approving a Site Development Review Permit for the Randeri Commercial Building (Randeri
7
# CONDITION TEXT RESPON.
AGENCY
WHEN REQ’D
Prior to:
13. Modifications. Modifications or changes to this Site
Development Review Permit approval may be considered
by the Community Development Director if the
modifications or changes proposed comply with Section
8.104.100 of the Dublin Zoning Ordinance.
PL On-going
14. Signage. Any signage shown on the Project Plans are for
illustrative purposes only and the full details of the sign
sizes, content, materials, and construction shall be shown
separately. Prior to the installation of any on-site signage,
the Applicant shall apply for signage and receive approval
from the Planning Division.
PL Signage
Installation
15. Construction Trailer. The Applicant shall obtain a
Temporary Use Permit prior to the establishment of any
construction trailer, storage shed, or container units on the
project site.
PL Establishment
of the
Temporary Use
16. Public Art. The Applicant/Developer intends to acquire
and install public art on the project site in accordance with
Chapter 8.58 of the Dublin Municipal Code. The value of
the public art project is required to equal or exceed 0.5
percent of the building valuation (exclusive of land) for the
entire project. The Chief Building Official will determine the
building valuation at the time of Plan Check submittal for the
first building permit on site. An agreement that sets forth
the ownership, maintenance responsibilities, and insurance
coverage for all public art on site shall be executed prior to
occupancy. All public art installations are subject to
approval of the City Council upon recommendation by the
Heritage and Cultural Arts Commission.
PL Building Permit
Issuance
PLANNING – DOWNTOWN DUBLIN SPECIFIC PLAN MITIGATION MEASURES
17. MM 3.3-1: Project applicants shall consult with a registered
geotechnical engineer to prepare a design level
geotechnical report that addresses the affects of seismic
ground shaking and includes a quantitative evaluation of
liquefaction and liquefaction-induced lateral spreading for
future development in the DDSP project area. The design
level geotechnical report shall specify foundations and
structural elements that are designed to resist forces and
potential ground settlement for liquefaction and lateral
spreading. This report shall be submitted in conjunction with
a Building Permit application.
PL Building Permit
Issuance
18. MM 3.5-1a: Prior to issuance of grading permit, the project
proponent shall file a Notice of Intent as required by
Regional Water Quality Control Board regarding storm
water discharges associated with construction activities.
Upon completion of construction activities, a Notice of
Termination shall be filed.
MM 3.5-1b: Prior to issuance of any building or grading
permits, a Storm Water Pollution Prevention Plan (SWPPP)
shall be prepared by the project contractors and submitted
PL/PW Site Work
(Grading
Permit)
5.1.a
Packet Pg. 20 Attachment: 1. Planning Commission Resolution approving a Site Development Review Permit for the Randeri Commercial Building (Randeri
8
# CONDITION TEXT RESPON.
AGENCY
WHEN REQ’D
Prior to:
to the Regional Water Quality Control Board for review and
comment and to the City of Dublin in conjunction with the
Building/Grading/Site work permit and shall be found to be
acceptable by the City prior to ground disturbance. The
SWPPP shall be prepared to Regional Water Quality
Control Board standards and Alameda Countywide Clean
Water Program requirements, and shall identify erosion
minimization and control provisions, pollution detection
provisions, and pollution elimination/ minimization
provisions appropriate to the development project and its
site for construction and post-construction activities. The
SWPPP shall include best available technology,
engineering, and design solutions such as the use of silt
screens, hay bales, modern trash screens, energy
dissipaters, and/or absorbent devices. Stormwater runoff
water quality monitoring procedures shall be clearly detailed
in the SWPPP.
19. MM 3.7-1a: Project applicants within the project area shall
prepare a construction noise management plan that
identifies measures to be taken to minimize construction
noise on surrounding sensitive receptors (e.g. residential
uses and schools) and includes specific noise management
measures to be included into project plans and
specifications subject to review and approval by the City.
These measures shall I include, but not be limited to the
following:
• Construction activities, including the maintenance
and warming of equipment, shall be limited to
Monday through Friday, and non-City holidays,
between the hours of 7:30 AM and 5:30 PM except
as otherwise approved by the City Engineer.
• All construction equipment shall be equipped with
mufflers and sound control devices (e.g., intake
silencers and noise shrouds) no less effective than
those provided on the original equipment and no
equipment shall have an un-muffled exhaust.
• The City shall require that the contractor maintain
and tune-up all construction equipment to minimize
noise emissions.
• Stationary equipment shall be placed so as to
maintain the greatest possible distance to the
sensitive receptors.
• All equipment servicing shall be performed so as to
maintain the greatest possible distance to the
sensitive receptors.
• The construction contractor shall provide an on -site
name and telephone number of a contact person. In
the event that construction noise is intrusive to an
PL/PW Building Permit
Issuance
5.1.a
Packet Pg. 21 Attachment: 1. Planning Commission Resolution approving a Site Development Review Permit for the Randeri Commercial Building (Randeri
9
# CONDITION TEXT RESPON.
AGENCY
WHEN REQ’D
Prior to:
educational process, the construction liaison will
revise the construction schedule to preserve the
learning environment.
• Select demolition methods to minimize vibration,
where possible (e.g., sawing masonry into sections
rather than demolishing it by pavement breakers).
MM 3.7-1b: Should the proposed project require off-site
import/export of fill material during construction, trucks shall
utilize a route that is least disruptive to sensitive receptors,
preferably major roadways (Interstate 580, Interstate 680,
San Ramon Road, Dublin Boulevard, and Amador Valley
Boulevard). Construction trucks should, to the extent
practical, avoid the weekday and Saturday a.m. and p.m.
peak hours (7:00 a.m. to 9:00 a.m. and 4:00 p.m. to 6:00
p.m.).
PLANNING - LANDSCAPE
20. Final Landscape and Irrigation Plan. Plans shall comply
with Chapter 8.72 and be generally consistent with the
project plans attached to this Resolution as Exhibit A and
date stamped received on December 13, 2019. A Final
Landscape and Irrigation Plan prepared and stamped by a
State licensed landscape architect or registered engineer
shall be submitted for review and approval by the
Community Development Director. Landscape and
irrigation plans shall provide for a recycled water system.
PL Building Permit
Issuance or
Approval of
Improvement
Plans
21. Water Efficient Landscaping Ordinance. The Landscape
and Grading Plans shall comply with Chapter 8.08 of the
Dublin Zoning Ordinance (Water Efficient Landscaping
Ordinance).
PL Building Permit
Issuance or
Approval of
Improvement
Plans
22. Sustainable Landscape Practices. The landscape design
shall demonstrate compliance with sustainable landscape
practices as detailed in the Bay-Friendly Landscape
Guidelines by earning 60 points or more and meeting the
nine required practices in the Bay-Friendly Landscape
Scorecard.
PL Building Permit
Issuance or
Approval of
Improvement
Plans
23. Street Trees. The two street trees adjacent to the project
frontage along Amador Valley Boulevard shall be protected
during construction. A tree protection plan shall be
submitted for review and approved by the Planning Division.
PL Building Permit
Issuance or
Approval of
Improvement
Plans
BUILDING AND SAFETY
24. Building Codes and Ordinances. All project construction
shall conform to all building codes and ordinances in effect
at the time of building permit.
B Through
Completion
25. Construction Drawings. Construction plans shall be fully
dimensioned (including building elevations), accurately
B Building Permit
Issuance
5.1.a
Packet Pg. 22 Attachment: 1. Planning Commission Resolution approving a Site Development Review Permit for the Randeri Commercial Building (Randeri
10
# CONDITION TEXT RESPON.
AGENCY
WHEN REQ’D
Prior to:
drawn (depicting all existing and proposed conditions on
site), and prepared/signed by a California licensed Architect
or Engineer. The site plan, landscape plan and details shall
be consistent with each other.
26. Building Permits. To apply for building permits, Applicant
shall submit electronic drawings and specifications, and the
number of hard copies – as determined by the Building
Official – for plan check. Each set of plans shall have
attached an annotated copy of these Conditio ns of
Approval. The notations shall clearly indicate how all
Conditions of Approval will or have been complied with.
Construction plans will not be accepted without the
annotated resolutions attached to each set of plans.
Applicant will be responsible for obtaining the approvals of
all participation non-City agencies prior to the issuance of
building permits.
B Building Permit
Issuance
27. As-Built Drawings. All revisions made to the building
plans during the project shall be incorporated into an “As
Built” electronic file and submitted prior to the issuance of
the final occupancy.
B Occupancy
28. Addressing.
a) Address signage shall be provided as per the Dublin
Commercial Security Code.
b) Address will be required on all doors leading to the
exterior of the building. Addresses shall be
illuminated and be able to be seen from the street,
four inches in height minimum
c) Project address currently has a single address. If
suites numbers are required, applicant shall process
request through the Building and Safety Division.
B
a) Permitting
b) Occupancy
c) Occupancy
of Suites
29. Engineer Observation. The Engineer of Record shall be
retained to provide observation services for all components
of the lateral and vertical design of the building, including
nailing, hold-downs, straps, shear, roof diaphragm and
structural frame of building. A written report shall be
submitted to the City Inspector prior to scheduling the final
frame inspection.
B Scheduling
the Final
Frame
Inspection
30. Foundation. Geotechnical Engineer for the soils report
shall review and approve the foundation design. A letter
shall be submitted to the Building Division on the approval.
B Occupancy
31. Air Conditioning Units. Air conditioning units and
ventilation ducts shall be screened from public view with
materials compatible to the main building. Units shall be
permanently installed on concrete pads or other non -
movable materials approved by the Chief Building Official
and Community Development Director.
B Occupancy
32. Plumbing Fixture Count. The plumbing fixture count (e.g.,
water closets, lavatories, urinals, sinks, and drinking
B Building Permit
Issuance
5.1.a
Packet Pg. 23 Attachment: 1. Planning Commission Resolution approving a Site Development Review Permit for the Randeri Commercial Building (Randeri
11
# CONDITION TEXT RESPON.
AGENCY
WHEN REQ’D
Prior to:
fountains) shall meet the minimum requirements for the as
regulated by CA Plumbing Code, Tables A and 422.1.
33. Cool Roofs- CA Energy Code. Flat roof areas shall have
their roofing material coated with light colored gravel or
painted with light colored or reflective material designed for
cool roofs.
B Through
Completion
34. Solar Zone – CA Energy Code. The location and
orientation detail of the Solar Zone shall be shown on the
site plan. This information shall be shown in the master plan
check on the overall site plan, the individual roof plans and
the plot plans. This condition of approval will be waived if
the project meets the exceptions provided in the CA Energy
Code.
B Through
Completion
35. Accessible Parking. The required number of parking
stalls, the design, and location of the accessible parking
stalls shall be as required by the CA Building Code, Chapter
11-B
B Through
Completion
36. Green Parking. The design and number of clean air/ EV
ready stalls shall be as required by the CA Green Building
Standards Code.
B Through
Completion
37. Accessory Structures. Building permits are required for
all trash enclosures and associated amenities/ structures
and are required to meet the accessibility and building
codes.
B Through
Completion
38. FEMA – Floodplain. The project is currently shown to be in
the floodplain. The applicant shall submit either a letter of
map amendment, letter of map change or letter of map
revision prior to permitting. If the site has not been removed
from the floodplain by a letter, then elevation certificates will
be required at the correct stages. In addition, if the site has
not been removed from the floodplain, buildings and
structures shall conform to the City’s Flood Control
requirements in the Dublin Municipal Code and FEMA
regulations.
B Building Permit
Issuance
39. Temporary Fencing. Temporary construction fencing shall
be installed along the perimeter of all exterior work under
construction.
B Through
Completion
40. Copies of Approved Plans. Applicant shall provide City
with one reduced (1/2 size) copy of the City of Dublin
stamped approved plan. Verify with Building Official if
electronic copy is acceptable prior to submittal.
Option: 1 (1/2 sized) plan set and one electronic copy.
B 30 days after
permit and
each revision
issuance
FIRE PREVENTION
41. Fire Service Lines. No fire service lines shall pass beneath
buildings.
F Building Permit
Issuance
5.1.a
Packet Pg. 24 Attachment: 1. Planning Commission Resolution approving a Site Development Review Permit for the Randeri Commercial Building (Randeri
12
# CONDITION TEXT RESPON.
AGENCY
WHEN REQ’D
Prior to:
42. New Fire Sprinkler System & Monitoring Requirements.
In accordance with the Dublin Fire Code, fire sprinklers shall
be installed in the building. The system shall be in
accordance with the NFPA 13, the CA Fire Code and CA
Building Code. Plans and specifications showing detailed
mechanical design, cut sheets, listing sheets and hydraulic
calculations shall be submitted to the Fire Department for
approval and permit prior to installation. This may be a
deferred submittal.
a) Sprinkler Plans. (Deferred Submittal Item). Submit
detailed mechanical drawings of all sprinkler modifications,
including cut sheets, listing sheets and calculations to the
Fire Department for approval and permit prior to installation.
b) Sprinkler System Components. All sprinkler system
components shall remain in compliance with the applicable
N.F.P.A. 13 Standard, the CA Fire Code and the CA
Building Code.
c) Underground Plans. (Deferred Submittal Item).
Detailed shop drawings for the fire water supply system,
including cut sheets, listing sheets and calculations shall be
submitted to the Fire Department for approval and permit
prior to installation. All underground and fire water supply
system components shall be in compliance with the
applicable N.F.P.A. 13, 24, 20, 22 Standards, the CA Fire
Code and the CA Building Code. The system shall be
hydrostatically tested and inspected prior to being covered.
Prior to the system being connected to any fire protection
system, a system flush shall be witnessed by the Fire
Department.
d) Central Station Monitoring. (Deferred Submittal
Item). Automatic fire extinguishing systems installed within
buildings shall have all control valves and flow devices
electrically supervised and maintained by an approved
central alarm station. Zoning and annunciation of central
station alarm signals shall be submitted to the Fire
Department for approval.
e) Fire Protection Equipment. Fire protection equipment
shall be identified with approved signs constructed of
durable materials, permanently installed and readily visible.
F Building Permit
Issuance
43. Fire Access During Construction.
a) Fire Access. Access roads, turnaround, pullouts, and
fire operation areas are fire lanes and shall be maintained
clear and free of obstructions, including the parking of
vehicles.
F During
Construction
5.1.a
Packet Pg. 25 Attachment: 1. Planning Commission Resolution approving a Site Development Review Permit for the Randeri Commercial Building (Randeri
13
# CONDITION TEXT RESPON.
AGENCY
WHEN REQ’D
Prior to:
b) Entrances. Entrances to job sites shall not be blocked,
including after hours, other than by approved
gates/barriers that provide for emergency access.
c) Site Utilities. Site utilities that would require the access
road to be dug up or made impassible shall be installed
prior to construction commencing.
d) Fire Lane. Entrance flare, angle of departure, width,
turning radii, grades, turnaround, vertical clearances, road
surface, bridges/crossings, gates/key-switch, within a 150-
foot distance to Fire Lane shall be maintained.
e) Personnel Access. Route width, slope, surface and
obstructions must be considered for the approved route to
furthermost portion of the exterior wall.
f) All-Weather Access. Fire access shall be all-weather
access. Show on the plans the location of the all-weather
access and a description of the construction. Access roads
must be designed to support the imposed loads of fire
apparatus.
44. Fire Extinguishers. Extinguishers shall be visible and
unobstructed. Signage shall be provided to indicate fire
extinguisher locations. The number and location of
extinguishers shall be shown on the plans. Additional fire
extinguishers maybe required by the Fire Inspector.
Fire extinguisher shall meet a minimum classification of 2A
10BC. Extinguishers weighing 40 pounds or less shall be
mounted no higher than five feet above the floor measured
to the top of the extinguisher. Extinguishers shall be
inspected monthly and serviced by a licensed concern
annually.
F Occupancy
45. Building Key Box. Building Access. A Fire Department
Key Box shall be installed at the main entrance to the
Building. Note these locations on the plans. The key box
should be installed approximately 5 1/2 feet above grade.
The box shall be sized to hold the master key to the facility
as well as keys for rooms not accessible by the master key.
Specialty keys, such as the fire alarm control box key and
elevator control keys shall also be installed in the box.
The key box door and necessary keys shall be provided to
the Fire Inspector upon the final inspection. The inspector
will then lock the keys into the box.
F Occupancy
46. Means of Egress. Exit signs shall be visible and illuminated
with emergency lighting when building is occupied.
F Occupancy
47. Main Entrance Hardware Exception. It is recommended
that all doors be provided with exit hardware that allows
exiting from the egress side even when the door is in the
locked condition. However, an exception for A-3, B, F, M, S
F Occupancy
5.1.a
Packet Pg. 26 Attachment: 1. Planning Commission Resolution approving a Site Development Review Permit for the Randeri Commercial Building (Randeri
14
# CONDITION TEXT RESPON.
AGENCY
WHEN REQ’D
Prior to:
occupancies and all churches does allow key-locking
hardware (no thumb-turns) on the main exit when the main
exit consists of a single door or pair of doors. When
unlocked the single door or both leaves of a pair of doors
must be free to swing without operation of any latching
device. A readily visible, durable sign on or just above the
door stating “This door to remain unlocked whenever
the building is occupied” shall be provided. The sign shall
be in letters not less than one inch high on a contrasting
background. This use of this exception may be revoked for
cause.
48. Maximum Occupant Load. Posting of room capacity is
required for any occupant load of 50 or more persons.
Submittal of a seating plan on 8.5” x 11” paper is required
prior to final occupancy.
F Occupancy
49. Interior Finish. Wall and ceiling interior finish material shall
meet the requirements of Chapter 8 of the California Fire
Code. Interior finishes will be field verified upon final
inspection. If the product is not field marked and the
marking visible for inspection, maintain the products cut-
sheets and packaging that show proof of the products
flammability and flame-spread ratings. Decorative materials
shall be fire retardant.
F Occupancy
50. General Inspection. Upon inspection of the work for which
this submittal was provided, a general inspection of the
business and site will be conducted.
F Occupancy
51. Addressing. Addressing shall be illuminated or in an
illuminated area. The address characters shall be
contrasting to their background. If address is placed on
glass, the numbers shall be on the exterior of the glass and
a contrasting background placed behind the numbers.
Building Address. The building shall be provided with all
addresses or the assigned address range so as to be
clearly visible from either direction of travel on the street the
address references. The address characters shall not be
less than five inches in height by one-inch stroke. Larger
sizes may be necessary depending on the setbacks and
visibility.
Multi-Tenants. Where a building has multiple tenants,
address shall also be provided near the main entrance door
of each tenant space. The address shall be high enough on
the building to be clearly visible from the driveway, street or
parking area it faces even when vehicles are parked in front
of the tenant space. The address shall not be less than five-
inches in height with a ½-inch stroke.
F Occupancy
52. Fire Safety During Construction and Demolition F Occupancy
5.1.a
Packet Pg. 27 Attachment: 1. Planning Commission Resolution approving a Site Development Review Permit for the Randeri Commercial Building (Randeri
15
# CONDITION TEXT RESPON.
AGENCY
WHEN REQ’D
Prior to:
a) Clearance to combustibles from temporary heating
devices shall be maintained. Devices shall be fixed in place
and protected from damage, dislodgement or overturning in
accordance with the manufacturer’s instructions.
b) Smoking shall be prohibited except in approved areas.
Signs shall be posted “NO SMOKING” in a conspicuous
location in each structure or location in which smoking is
prohibited.
c) Combustible debris, rubbish and waste material shall be
removed from buildings at the end of each shift of work.
Flammable and combustible liquid storage areas shall be
maintained clear of combustible vegetation and waste
materials.
DUBLIN SAN RAMON SERVICES DISTRICT (DSRSD)
53. Complete improvement plans shall be submitted to DSRSD
that conform to the requirements of the Dublin San Ramon
Services District Code, the DSRSD “Standard Procedures,
Specifications and Drawings for Design and Installation of
Water and Wastewater Facilities,” all applicable DSRSD
Master Plans and all DSRSD policies.
DSRSD Building Permit
Issuance
54. Planning and review fees, inspection fees, and fees
associated with a wastewater discharge permit shall be paid
to DSRSD in accordance with the rates and schedules and at
time of payment as established in the DSRSD Code.
Planning and review fees, Construction Permit and
Inspection Fees and Capacity Reserve Fees are due.
DSRSD Building Permit
Issuance
55. All improvement plans for DSRSD facilities shall be signed by
the District Engineer. Each drawing of improvement plans for
DSRSD facilities shall contain a signature block for the
District Engineer indicating approval of the sanitary sewer
and/or water facilities shown. Prior to approval by the District
Engineer, the Applicant shall pay all required DSRSD fees,
and provide an engineer’s estimate of construction costs for
the sewer and water systems, a faithful performance bond,
and a comprehensive general liability insurance policy in the
amounts and forms that are acceptable to DSRSD. The
Applicant shall allow at least 15 working days for final
improvement drawing review by DSRSD before signature by
the District Engineer.
DSRSD Building Permit
Issuance
56. All mains shall be sized to provide sufficient capacity to
accommodate future flow demands in addition to each
development project's demand. Layout and sizing of mains
shall be in conformance with DSRSD utility master
planning.
DSRSD Building Permit
Issuance
57. The locations and widths of all proposed easement
dedications for water and sewer lines shall be submitted to
and approved by DSRSD.
DSRSD Building Permit
Issuance
5.1.a
Packet Pg. 28 Attachment: 1. Planning Commission Resolution approving a Site Development Review Permit for the Randeri Commercial Building (Randeri
16
# CONDITION TEXT RESPON.
AGENCY
WHEN REQ’D
Prior to:
58. Water and sewer mains shall be located in public streets
rather than in off-street locations to the fullest extent
possible. If unavoidable, then sewer or water easements
must be established over the alignment of each sewer or
water main in an off-street or private street location to
provide access for future maintenance and/or replacement.
DSRSD Building Permit
Issuance
59. Domestic and fire protection waterline systems for
commercial developments shall be designed to be looped
or interconnected to avoid dead end sections in accordance
with requirements of the DSRSD Standard Specifications
and sound engineering practice.
DSRSD Building Permit
Issuance
60. Sewers shall be designed to operate by gravity flow to
DSRSD’s existing sanitary sewer system. Pumping of
sewage is discouraged and may only be allowed under
extreme circumstances following a case by case review
with DSRSD staff. Any pumping station will require specific
review and approval by DSRSD of preliminary design
reports, design criteria, and final plans and specifications.
DSRSD reserves the right to require payment of present
worth 20 year maintenance costs as well as other
conditions within a separate agreement with the applicant
for any project that requires a pumping station.
DSRSD Building Permit
Issuance
61. This project will be analyzed by DSRSD to determine if it
represents additional water an/or sewer capacity demands
on the district. Applicant will be required to pay all
incremental capacity reserve fees for water and sewer
services as required by the project demands. All capacity
reserve fees must be paid prior to installation of water meter
for water. If a water meter is not required, the capacity
reserve fee shall be paid prior to issuance of a building
permit. The District may not approve the building permit
until capacity reserve fees are paid.
DSRSD Building Permit
Issuance and
On-going
62. No sewer line or waterline construction shall be permitted
unless the proper utility construction permit has been issued
by DSRSD. A construction permit will only be issued after
all of the items in Condition No. 55 have been satisfied.
DSRSD Building Permit
Issuance
63. Above-ground backflow prevention devices/double detector
check valves shall be installed on fire protection systems
connected to the DSRSD water main. The Applicant shall
collaborate with the Fire Department and DSRSD to size
and configure the fire system.
DSRSD Building Permit
Issuance and
On-going
64. Development plans will not be approved until landscape
plans are submitted for DSRSD review and approval.
DSRSD Approval of
Final
Landscape
Plans
PUBLIC WORKS GENERAL CONDITIONS
65. Compliance. Applicant shall comply with the Subdivision
Map Act, the City of Dublin Subdivision and Zoning PW On-going
5.1.a
Packet Pg. 29 Attachment: 1. Planning Commission Resolution approving a Site Development Review Permit for the Randeri Commercial Building (Randeri
17
# CONDITION TEXT RESPON.
AGENCY
WHEN REQ’D
Prior to:
Ordinances, City of Dublin Title 7 Public Works Ordinance,
which includes the Grading Ordinance, the City of Dublin
Public Works Standards and Policies, the most current
requirements of the State Code Title 24 and the Americans
with Disabilities Act with regard to accessibility, and all
building and fire codes and ordinances in effect at the time
of building permit. All public improvements constructed by
Applicant and to be dedicated to the City are hereby
identified as “public works” under Labor Code section 1771.
Accordingly, Applicant, in constructing such improvements,
shall comply with the Prevailing Wage Law (Labor Code.
Sects. 1720 and following).
66. Clarifications and Changes to the Conditions. In the
event that there needs to be clarification to these Conditions
of Approval, the City Engineer has the authority to clarify the
intent of these Conditions of Approval to the Applicant
without going to a public hearing. The City Engineer also
has the authority to make minor modifications to these
conditions without going to a public hearing in order for the
Applicant to fulfill needed improvements or mitigations
resulting from impacts of this project.
PW On-going
67. Zone 7 Impervious Surface Fees. The Applicant shall
complete a “Zone 7 Impervious Surface Fee Application”
and submit an accompanying exhibit for review by the
Public Works Department. Fees generated by this
application will be due at issuance of building permit.
PW
Grading Permit
or Building
Permit
Issuance
PUBLIC WORKS – AGREEMENTS
68. Storm Water Treatment Measures Maintenance
Agreement. Applicant shall enter into an Agreement with
the City of Dublin that guarantees the property owner’s
perpetual maintenance obligation for all stormwater
treatment measures installed as part of the project,
including pervious concrete pavement and those on-site
and within the public right-of-way. Pervious concrete
pavement must be cleaned periodically by vacuuming to
remove sediments that have accumulated. The frequency
of vacuuming depends on the amount of sediments on the
surface over time.
In general, maintenance of pervious concrete pavement
consists of the following:
• Monitoring the surface for sediment buildup and
removing that buildup as needed.
• Visually inspect pervious pavement area, maintain
upland and adjacent landscape areas and excessive
water flow carrying debris toward the pavement should
be diverted.
• Avoid sealing or repaving with impervious materials, in
particular never use asphalt or other tar-type sealers.
PW Occupancy
5.1.a
Packet Pg. 30 Attachment: 1. Planning Commission Resolution approving a Site Development Review Permit for the Randeri Commercial Building (Randeri
18
# CONDITION TEXT RESPON.
AGENCY
WHEN REQ’D
Prior to:
Said Agreement is required pursuant to Provision C.3 of the
Municipal Regional Stormwater NPDES Permit, Order No.
R2-2009-0074. Said permit requires the City to provide
verification and assurance that all treatment devices will be
properly operated and maintained. The Agreement shall be
recorded against the property and shall run with the land.
PUBLIC WORKS – PERMITS AND BONDS
69. Encroachment Permit. Applicant shall obtain an
Encroachment Permit from the Public Works Department
for all construction activity within the public right -of-way.
The encroachment permit may require surety for slurry seal
and restriping.
PW Permit
Issuance
70. Grading Permit. Applicant shall obtain a Grading Permit
from the Public Works Department for all grading. PW Permit
Issuance
71. Security. Applicant shall provide faithful performance
security to guarantee the improvements, as determined by
the City Engineer. (Note: The performance security shall
remain in effect until one year after final inspection.)
PW Permit
Issuance
72. Permits from Other Agencies. Applicant shall obtain all
permits and/or approvals required by other agencies
including, but not limited to:
• Regional Water Quality Control Board
• Federal Emergency Management Agency
• California Dept. of Transportation (Caltrans)
• Dublin San Ramon Services District (DSRSD)
Alameda County Flood Control and Water Conservation
District Zone 7 (Zone 7)
PW Permit
Issuance
PUBLIC WORKS – SUBMITTALS
73. Improvement Plan Submittal Requirements. All
submittals of plans shall comply with the requirements of
the “City of Dublin Public Works Department Improvement
Plan Submittal Requirements,” the “City of Dublin
Improvement Plan Review Check List,” and current Public
Works and industry standards. A complete submittal of
improvement plans shall include all civil improvements, joint
trench, street lighting and on-site safety lighting, landscape
plans, and all associated documents as required. Applicant
shall not piecemeal the submittal by submitting various
components separately.
PW Grading Permit
Issuance
74. Improvement Plan Requirements from Other Agencies.
Applicant will be responsible for submittals and reviews to
obtain the approvals of all participating non-City agencies,
including but not limited to: the Alameda County Fire
Department and the Dublin San Ramon Services District.
PW Grading Permit
Issuance
75. Composite Exhibit. Construction plan set shall include a
Composite Exhibit showing all site improvements, utilities,
landscaping improvements and trees, etc. to be constructed
PW Grading Permit
Issuance
5.1.a
Packet Pg. 31 Attachment: 1. Planning Commission Resolution approving a Site Development Review Permit for the Randeri Commercial Building (Randeri
19
# CONDITION TEXT RESPON.
AGENCY
WHEN REQ’D
Prior to:
to ensure that there are no conflicts among the proposed
and existing improvements.
76. Geotechnical Report. Applicant shall submit a Design
Level Geotechnical Report, which includes street pavement
sections, grading and additional information and/or
clarifications as determined by the City Engineer.
PW Grading Permit
Issuance
77. Building Pads. Applicant shall provide the Public Works
Department with a letter from a registered civil engineer or
surveyor stating that the building pads have been graded to
within 0.1 feet of the grades shown on approved Grading
Plans.
PW Certificate of
Occupancy
78. Approved Plan Files. Applicant shall provide the Public
Works Department a PDF format file of approved site plans,
including grading, improvement, landscaping and irrigation,
joint trench and lighting.
PW Certificate of
Occupancy
79. Master Files. Applicant shall provide the Public Works
Department a digital vectorized file of the “master” files for
the project, in a format acceptable to the City Engineer.
Digital raster copies are not acceptable. The digital
vectorized files shall be in AutoCAD 14 or higher drawing
format. All objects and entities in layers shall be colored by
layer and named in English. All submitted drawings shall
use the Global Coordinate System of USA, California, NAD
83 California State Plane, Zone III, and U.S. foot.
PW Acceptance of
Improvements
PUBLIC WORKS - EASEMENTS AND ACCESS RIGHTS
80. Approval by Others. The Applicant will be responsible for
submittals and reviews to obtain the approvals of all
applicable non-City agencies.
PW Grading Permit
Issuance
81. Grading Plan. The Grading Plan shall be in conformance
with the recommendation of the Geotechnical Report, the
approved Site Development Review, and the City design
standards and ordinances. In case of conflict between the
soil engineer’s recommendation and the City ordinances,
the City Engineer shall determine which shall apply.
PW Grading Permit
Issuance
82. Geotechnical Engineer Review and Approval. The
Project Geotechnical Engineer shall be retained to review
all final grading plans and specifications. The Project
Geotechnical Engineer shall approve all grading plans prior
t City approval.
PW Grading Permit
Issuance
83. Grading Off-Haul. The disposal site and haul truck route
for any off-haul dirt materials shall be subject to the review
and approval by the City Engineer prior to the issuance of a
Grading Permit. If the Applicant does not own the parcel on
which the proposed disposal site is located, the Applicant
shall provide the City with a Letter of Consent signed by the
current owner, approving the placement of off-haul material
on their parcel. A Grading Plan may be required for the
placement of the off-haul material.
PW Grading Permit
Issuance
5.1.a
Packet Pg. 32 Attachment: 1. Planning Commission Resolution approving a Site Development Review Permit for the Randeri Commercial Building (Randeri
20
# CONDITION TEXT RESPON.
AGENCY
WHEN REQ’D
Prior to:
84. Erosion Control Plan. A detailed Erosion and Sediment
Control Plan shall be included with the Grading Plan
submittal. The plan shall include detailed design, location,
and maintenance criteria of all erosion and sedimentation
control measures.
PW Grading Permit
Issuance
85. Demolition Plan. The Applicant’s Civil Engineer shall
prepare a demolition plan for the project, which shall be
submitted concurrent with the improvement plan package.
The demolition plan shall address the following:
• Pavement demolition, including streetlights and
landscaped median islands.
• Landscaping and irrigation.
• Fencing to be removed and fencing to remain.
• An items to be saved in place and or protected, such as
trees, water meters, sewer cleanouts, drainage inlets or
backflow prevention devices.
PW Grading Permit
Issuance
PUBLIC WORKS – STORM DRAINAGE & OTHER UTILITIES
86. Pervious Concrete Pavement. Applicant shall submit a
Pervious Concrete Pavement Maintenance Plan for review
and approval by Public Works Department and
Environmental Coordinator. The Contractor that installs the
proposed pervious concrete pavement shall be certified by
National Ready Mix Concrete Association (NRMCA)
Pervious Concrete Contractor Certification Program.
PW Grading Permit
Issuance
87. Overland Release. Grading and drainage shall be
designed so that surplus drainage (above and beyond that
of the 10-year storm event) not collected in site catch
basins, is directed overland so as not to cause flooding of
existing or proposed buildings.
PW Grading Permit
Issuance
88. Dry Utilities. Applicant shall construct gas, electric,
telephone, cable TV, and communication improvements
within the fronting streets and as necessary to serve the
project as approved by the City Engineer and various public
utility agencies.
PW Occupancy
89. Dry Utility Locations. All electric, telephone, cable TV,
and communications utilities, shall be placed underground
in accordance with the City policies and ordinances. All
utilities shall be located and provided within public utility
easements or public services easements and sized to meet
utility company standards.
PW Occupancy
90. Utility Vaults and Boxes. All utility vaults, boxes, and
structures, unless specifically approved otherwise by the
City Engineer, shall be underground and placed in
landscaped areas and screened from public view.
Landscape drawings shall be submitted to the City showing
the location of all utility vaults, boxes, and structures and
adjacent landscape features and plantings.
PW Occupancy
PUBLIC WORKS - CONSTRUCTION
5.1.a
Packet Pg. 33 Attachment: 1. Planning Commission Resolution approving a Site Development Review Permit for the Randeri Commercial Building (Randeri
21
# CONDITION TEXT RESPON.
AGENCY
WHEN REQ’D
Prior to:
91. Erosion Control Implementation. The Erosion and
Sediment Control Plan shall be implemented between
October 1st and April 30th unless otherwise allowed in
writing by the City Engineer. The Applicant will be
responsible for maintaining erosion and sediment control
measures for one year following the City’s acceptance of
the improvements.
PW
Start of
Construction
and On-going
92. Archaeological Finds. If archaeological materials are
encountered during construction, construction within 100
feet of these materials shall be halted until a professional
Archaeologist certified by the Society of Calif. Archaeology
(SCA) or the Society of Professional Archaeology (SOPA)
has had an opportunity to evaluate the significance of the
find and suggest appropriate mitigation measures.
PW
Start of
Construction
and On-going
93. Construction Activities. Construction activities, including
the idling, maintenance, and warming up of equipment,
shall be limited to Monday through Friday, and non -City
holidays, between the hours of 7:30 a.m. and 5:00 p.m.
except as otherwise approved by the City Engineer.
Extended hours or Saturday work will be considered by the
City Engineer on a case-by-case basis. Note that the
construction hours of operation within the public right -of-
way are more restrictive.
PW
Start of
Construction
and On-going
94. Temporary Fencing. Temporary construction fencing shall
be installed along the construction work perimeter to
separate the construction area from the public. All
construction activities shall be confined within the fenced
area. Construction materials and/or equipment shall not be
operated/stored outside of the fenced area or within the
public right-of-way unless approved in advance by the City
Engineer.
PW
Start of
Construction
and On-going
95. Construction Noise Management Plan. Applicant shall
prepare a construction noise management plan that
identifies measures to minimize construction noise on
surrounding developed properties. The plan shall include
hours of construction operation, use of mufflers on
construction equipment, speed limit for construction traffic,
haul routes and identify a noise monitor. Specific noise
management measures shall be provided prior to project
construction.
PW
Start of
Construction
Implementation
, and On-going
as needed
96. Traffic Control Plan. Closing of any existing pedestrian
pathway and/or sidewalk during construction shall be
implemented through a City-approved Traffic Control Plan
and shall be done with the goal of minimizing the impact on
pedestrian circulation.
PW
Start of
Construction
and On-going
as needed
97. Construction Traffic Interface Plan. Applicant shall
prepare a plan for construction traffic interface with public
traffic on any existing public street. Construction traffic and
PW
Start of
Construction;
Implementation
5.1.a
Packet Pg. 34 Attachment: 1. Planning Commission Resolution approving a Site Development Review Permit for the Randeri Commercial Building (Randeri
22
# CONDITION TEXT RESPON.
AGENCY
WHEN REQ’D
Prior to:
parking may be subject to specific requirements by the City
Engineer.
, and On-going
as needed
98. Pest Control. Applicant shall be responsible for controlling
any rodent, mosquito, or other pest problem due to
construction activities.
PW On-going
99. Dust Control Measures. Applicant shall be responsible for
watering or other dust-palliative measures to control dust as
conditions warrant or as directed by the City Engineer. PW
Start of
Construction;
Implementation
On-going as
needed
100. Construction Traffic and Parking. All construction-
related parking shall be off-street in an area provided by the
Applicant. Construction traffic and parking shall be
provided in a manner approved by the City Engineer.
PW
Start of
Construction
and On-going
101. Fire Access. Access roads, turnarounds, pullouts, and fire
operation areas are Fire Lanes and shall be maintained
clear and free of obstructions, including the parking of
vehicles.
Various
Depts
Start of
Construction
and On-going
102. Dust Control/Street Sweeping. The Applicant shall
provide adequate dust control measures at all times during
the grading and hauling operations. All trucks hauling export
and import materials shall be provided with tarp cover at all
times. Spillage of haul materials and mud -tracking on the
haul routes shall be prevented at all times. The Applicant
shall be responsible for sweeping of streets within,
surrounding and adjacent to the project if it is determined
that the tracking or accumulation of material on the streets
is due to its construction activities.
PW During Grading
and Site Work
103. Street Restoration. A pavement treatment, such as slurry
seal or grind and overlay, will be required within the public
streets fronting the site as determined by the Public Works
Department. The type and limits of the pavement treatment
shall be determined by the City Engineer based upon the
number and proximity of trench cuts, extent of frontage and
median improvements, extent of pavement striping and
restriping, excessive wear and tear/damage due to
construction traffic, etc.
PW Final
Occupancy
PUBLIC WORKS - CONSTRUCTION
104. Stormwater Treatment. Consistent with Provision C.3.i of
the Municipal Regional Stormwater NPDES Permit (MRP)
Order No. R2-2015-0049, the Applicant shall submit
documentation including construction drawings
demonstrating all stormwater treatment measures is met.
PW Grading Permit
Issuance
105. SWPPP. The Storm Water Pollution Prevention Plan
(SWPPP), if required, shall identify Best Management
Practices (BMPs) appropriate to the project construction
activities. The SWPPP shall include erosion and sediment
control measures in accordance with the regulations
PW
SWPPP to be
Prepared Prior
to Grading
Permit
Issuance;
5.1.a
Packet Pg. 35 Attachment: 1. Planning Commission Resolution approving a Site Development Review Permit for the Randeri Commercial Building (Randeri
23
# CONDITION TEXT RESPON.
AGENCY
WHEN REQ’D
Prior to:
outlined in the most current version of the Association of
Bay Area Governments (ABAG) Erosion and Sediment
Control Handbook or State Construction Best Management
Practices Handbook. The Applicant is responsible for
ensuring that all contractors implement all storm water
pollution prevention measures in the SWPPP.
Implementation
Prior to Start of
Construction
and On-going
as needed
106. Stormwater Management Plan. A final Stormwater
Management Plan shall be submitted for review and
approval by the City Engineer. Approval is subject to the
Applicant providing the necessary plans, details, and
calculations that demonstrate the plan complies with the
standards issued by the San Francisco Bay Regional Water
Quality Control Board and Alameda Countywide Clean
Water Program, including provisions for implementing all
applicable Stormwater Source Control measures.
PW Grading Permit
Issuance
PUBLIC WORKS – ON-SITE IMPROVEMENTS
107. Drive Aisle Width. The parking lot aisles shall be a
minimum of 24 feet wide to allow for adequate on-site
vehicle circulation for cars, trucks, and emergency vehicles.
PW Grading Permit
Issuance
108. On-site Signing and Striping Plan. A Traffic Signing and
Striping Plan showing all proposed signing and striping
within on-site parking lots and drive aisles, shall be
submitted for review and approval by the City Engineer.
This includes striping of the entrance/ exit aisle to Village
Parkway to clearly delineate two-way traffic.
PW Grading Permit
Issuance
109. Vehicle Parking. All on-site vehicle parking spaces shall
conform to the following:
a. All parking spaces shall be double striped using four-
inch white lines set two feet apart in accordance with
City Standards and DMC 8.76.070.A.17.
b. Concrete step-out curbs 12 inches in width shall be
constructed at each parking space where one or both
sides abut a landscaped area or planter.
c. Where wheel stops are shown, individual six-foot long
wheel stops shall be provided within each parking space
in accordance with City Standards.
d. A minimum two-foot radius shall be provided at curb
returns and curb intersections where applicable.
e. Parking stalls next to walls, fences and obstructions to
vehicle door opening shall be an additional four feet in
width per DMC 8.76.070.A.16.
f. Landscaped strips adjacent to parking stalls shall be
unobstructed in order to allow for a minimum two-foot
vehicular overhang at front of vehicles.
Accessible parking spaces shall comply with CBC 11B-
502.2. Van Accessible parking spaces shall be 144 inches
wide minimum, shall be marked to define the width, and
PW Grading Permit
Issuance
5.1.a
Packet Pg. 36 Attachment: 1. Planning Commission Resolution approving a Site Development Review Permit for the Randeri Commercial Building (Randeri
24
# CONDITION TEXT RESPON.
AGENCY
WHEN REQ’D
Prior to:
shall have an adjacent access aisle complying with section
11B-502.3. Van parking spaces shall be permitted to be 108
inches wide minimum where the access aisle is 96 inches
wide minimum.
110. Site Accessibility Requirements. All parking spaces for
the disabled and other physical site improvements shall
comply with current CBC Title 24 requirements and City of
Dublin Standards for accessibility.
Per CBC 11B-502.8, a site entrance sign is required at the
entrance to the site. The additional sign shall clearly state
in letters with a minimum height of one-inch the following:
“Unauthorized” vehicles parked in designated accessible
spaces not displaying distinguishing placards or special
license plates issued for persons with disabilities will be
towed away at the owner’s expense. Towed vehicles
may be reclaimed at: _________________________ or
by telephoning ______________________.
Blank spaces shall be filled in with appropriate
information as a permanent part of the sign.
Contact should be Dublin Police
Phone number to reclaim towed vehicles is (925) 833-
6670.
PW Prior to
Occupancy
111. Photometrics. The Applicant shall provide a complete
photometrics plan for both on-site and frontage roadways.
Include the complete data on photometrics, including the
high, average and minimum values for illuminance and
uniformity ratio.
PW Prior to
Occupancy
112. Trash Enclosure. The trash enclosure shall meet all of the
requirements set forth within the Dublin Municipal Code
Section 7.98, including but not limited to providing sewer
and water hook-ups. The improvement plans and/or
building permit plans shall show additional information
demonstrating these requirements are met. A pedestrian
accessible path of travel shall be provided for employees
from the building to the trash enclosure in conformance with
current accessibility requirements.
PW Grading Permit
Issuance
PASSED, APPROVED AND ADOPTED this 28th day of January 2020 by the following vote:
AYES:
NOES:
ABSENT:
ABSTAIN:
5.1.a
Packet Pg. 37 Attachment: 1. Planning Commission Resolution approving a Site Development Review Permit for the Randeri Commercial Building (Randeri
25
______________________________
Planning Commission Chair
ATTEST:
____________________________
Assistant Community Development Director
5.1.a
Packet Pg. 38 Attachment: 1. Planning Commission Resolution approving a Site Development Review Permit for the Randeri Commercial Building (Randeri
URINALREQ.PER 2016 CPC, TABLE 422-1REQ.WATER CLOSETS1SERVICE SINKTel: 510/652-4433COVER SHEET PROJECT DATAPROP.LAV.PROP.1REQ.112REQ.55MAX FAR: 0.35PROP.DATEPARCEL MAP2. THIS BUILDING IS LOCATED IN A FEMA DESIGNATED AO FLOOD PLAIN AND SHALL UTILIZE CONTRUCTION MATERIAL AND METHODS TO ADHERE TO FEMA FLOOD PLAIN CONSTRUCTION REQUIREMENTS. SHEET NO.OCC. LOAD:113MERCANTILE / RETAILABBREVIATIONS32REVISIONSOCCUPANCY DATAFax: 510/652-5111SYMBOLSA07400 AMADOR VALLEY BOULEVARDDUBLIN CALIFORNIA 94568VICINITY MAPDRAWING INDEXPROJECT DATANOTESDRAWN BYNEW RETAIL BUILDINGALL GENDER ALL GENDER31TOTALPLUMBING FIXTURE REQ.PROP.17400 AMADOR VALLEY BOULEVARDDUBLIN CALIFORNIA 945684050 Harlan Street, Emeryville California 94608Beaumont + AssociatesNEW RETAIL BUILDING RESTROOM66 1100RESTROOM10410510666 1100103 RESTROOM30A0 COVER SHEETA1 SITE PLANA2 PROPOSED FLOOR PLANA3 PROPOSED EXTERIOR ELEVATIONSA4 PROPOSED EXTERIOR ELEVATIONSA5 BUILDING SECTIONA6 TRASH ENCLOSURE DRAWINGSA7 ROOF PLANL1 LANDSCAPE PLANC1 CIVIL SITE PLAN AND NOTESC2 CIVIL EXISTING CONDITIONS AND DEMO PLANC3 PRELIMINARY GRADING, DRAINAGE AND UTILITY PLANC4 PRELIMINARY STORM WATER CONTROL PLAN C5 CLEAN BAY BLUEPRINTU1 PRELIMINARY UTILITY PLAN66RETAILCALIFORNIA BUILDING CODE (CBC)CALIFORNIA MECHANICAL CODE (CMC)CALIFORNIA PLUMBING CODE (CPC)CALIFORNIA ELECTRICAL CODE (CEC)CALIFORNIA GREEN BUILDING CODE (CGBSC)CALIFORNIA ENERGY STANDARDSDUBLIN MUNICIPAL CODE (DMC)2016 EDITION2016 EDITION2016 EDITION 2016 EDITION 2016 EDITION2016 EDITION2016 EDITIONRESTROOM 666611100103 RESTROOM1100RESTROOM66 1100101100102REQ. PROP.3266OCCUPANCYDESCRIPTION7400 AMADOR VALLEY BOULEVARDDUBLIN CA 94568APN: 941-210-1-4EXISTING USE: VACANT LOTPROPOSED USE: NEW RETAIL BUILDINGGENERAL PLAN: DOWNTOWN DUBLIN- VILLAGE PARKWAY DISTRICTZONING DISTRICT: DDZDOCCUPANCY : M ( RETAIL )CONSTRUCTION TYPE: VNO. FLOORS: 1FIRE SPRINKLERS: YESNO PARKING SPACES: 12FACTORLOADNO. EXITSTOTAL3,198 107113ALL OTHER APPLICABLE CITY CODES AND REGULATIONSAPPLICABLE CODES:AREAROOM3,613MB3,578TELEPHONE OUTLETPERPENDICULAR220V OUTLETCABLE TV OUTLETDOOR SYMBOLCOLUMN GRIDSGALLONGAUGEGALVANIZED IRONGLUE LAMINATED BEAMGRADEGYPSUM BOARDGYPSUM WALL BOARDHANDRAILHANICAPPEDHOLDOWNHORIZONTALHIGH STRENGTH BOLTSHEIGHTHOT WATERHEADERINCHESINSIDE DIAMETERINSULATIONJOINTJOISTLONG(LENGTH)LABORATORYLINEARMAXIMUMMACHINE BOLTSMECHANICALMETALMEZZANINEMANUFACTURERMINIMUMNEWNOT APPLICABLENOT IN CONTRACTNOMINALNOT TO SCALEON CENTEROPPOSITE HANDOPPOSITEPOCKET DOORPOWER DRIVEN FASTENERPERIMETERPRECAST CONCRETEPLATEPROPERTY LINEPLYWOODPLATE NAILPOUND PER SQUARE FT.POUND PER SQUARE INCHPRESSURE TREATEDREMOVERISERRADIUSREINFORCEMENTREQUIREDREFRIGERATORROUGH OPENINGROUGH SAWNREDWOODROUGHRAIN WATER LEADER WORK POINTANMINISTRATIONANCHOR BOLTACOUSTICALALUMINIUMALTERNATEAPPROXIMATEARCHITECTUREALUMINIUM SLIDERBUILDINGBLOCKBLOCKINGBEAMBOUNDRY NAILBOTTOMBOARDBETTERBETWEENCATWALKCONSTRUCT. JOINTCLEARCENTER COLUMNCONCRETECONNECTIONCONTINUOUSCONTRACTORCORRIDORCORRUGATEDDIAMETERDOUBLEDOUGLAS FIRDIAGONALDIMENSION DOWNDOORDISHWASHERDOWN SPOUTEXISTINGEACHEACH FACEEXPANSION JOINTELEVATIONELECTRIC(AL)EDGE NAILEQUAL EQUIPMENTEACH SIDEEACH WAY EXPANSIONEXPANSION JOINTFLAT BARFOUNDATIONFIXED GLASSFINISHED DOORFLOOR JOISTFLANGEFLOORFLUORESCENTFIELD NAILFACE OF CONCRETEFACE OF FINISHFREE OF HEART CENTERFACE OF MASONRYFACE OF STUDFULL PENETRATIONFOOT/FEETFOOTINGFURNITURE SHEETSINGLE HUNGSIMILARSINKSLIDERSLAB ON GRADESPECIFICATIONSSQUARESTIFFENERSTEELSTRUCTURALSTRUCTURALSTRUCTURALSYMETRICALTHREADTOP AND BOTTOMTONGUE AND GROOVETOP OF CURBTELEPHONETOP OF CONCRETETOP O F PLATETOP OF SLABTOP OF STEELTOP OF FLOORTOP OF WALLTOP OF PAVEMENTTREADTRANSVERSEUNLESS OTHERWISE NOTEDVERTICALWIDEWASHERWITHWATER CLOSETWOODWITHOUTWATERPROOFWEATHERPROOFWORKING POINTWIDE FLANGEWATERPROFFINGCROSSSHEARWALL SYMBOLSWITCHLIGHT FIXTURE-CEILINGLIGHT FIXTURE - WALLLIGHT FIXTURE - RECESSP4123SHEET NUMBERNORTH ORIENTATIONNORMAL FLOOR LEVELOR WORK POINT DETAIL NUMBERSHEET NUMBERINTERIOR ELEVATIONSSMOKE DETECTORANDSELECTION NUMBERSHEET NUMBERELEVATION NUMBERLIGHT W / EXH. FANLIGHT - FLUOR. STRIPELECTRICAL SYMBOLSDUPLEX OUTLETSSHT.S.H.SIM.SK.SLDR.S.O.G.SPEC.SQ.STIFF.STL.STR.STRL.STRUC.SYM.T.T&BT>.C.TEL.T.O.C.T.O.P.T.O.S.T.O.STLT.O.F.T.O.W.T.P.TRD.TRANSV.U.O.N.VERT.W.WSH.W/W.C.WDW/OWP.W.P.W.PT.W.F.WPFG.XGAL.GA.GI.GLB.GRD.GYP.BD.G.W.B.HNDR.H/CHD.HORIZ.H.S.B.HT.H.W.HDR.IN.I.D.INSUL.JT.JST.L.LAB.LIN.MAX.M.B.MECH.MTL.MEZZ.MFR.MIN.N.N/AN.I.C.NOM.N.T.S.O.C.O.H.OPP.P.D.P.D.F.PERM.P.C.PLP.L.PLYD.PN.P.S.F.P.S.IPRES.TRT.(R)R.RAD.REINF.REQ'DREFR.R.O.R.S.RDWD.RO.R.W.LADM.A.B.ACOUS.ALUM.ALT.APPROX.ARCH.ALS.BLDG.BLK.BLKG.BM.B.N.BOT.BRD.BTR.BTWN.CAT.C.J.CLR.CNTR.COL.CONC.CONN.CONTR.CORR.CORR.DIA.DBL.DF.DIAG.DIM.DN.DR.DW.D.S.E.EA.E.F.E.J.EL.ELEC.E.N.EQ.EQPT.E.S.E.W.EX.EXP.JT.F.B.FDN.F.G.FIN.FL.F.J.FLNG.FL.FLUOR.F.N.F.O.C.F.O.F.F.O.H.C.F.O.M.F.O.S.F.P.FT.FTG.FURN.LPLATE PROPERTY LINE#POUND OR NUMBERCENTERLINECWINDOW SYMBOL@ATANGLE&.3233,578 / 11,073 = .3233,5781 PLANS SHALL BE REVIEWED BY A INDEPENDANT CERTIFIED ACCESS SPECIALIST PRIOR TO BUILDING PERMIT SUBMITTAL209583BUILDINGTRASH ENCLOSUREWALKWAY/SIDEWALKENTRY PAVEMENT4,305PARKING LOT1,710PERVIOUS SURFACE1,71011,073IMPERVIOUS SURFACE4,305583646LANDSCAPE64620910/21/19LOT SIZEAREA (SF) FLOOR AREA RATIO (FAR)4,4056,668SQUARE FOOTAGEOWNER:SITE INFORMATION:SCOPE OF WORK1. CONSTRUCT NEW 3,578 SF RETAIL BUILDING2. INSTALL NEW PARKING LOT 3. NEW TRASH ENCLOSURECHETAN & RIA RANDERI34194 DONAHUE TERRACEFREMONT CA 94551(408)398-11465.1.bPacket Pg. 39Attachment: 2. Exhibit A to Attachment 1: Project Plans (Randeri SDR)
PAVERSPAVERSF.D.NOTE:THIS BUILDING IS LOCATED IN A FEMA DESIGNATED AO FLOOD PLAIN AND SHALL UTILIZE CONTRUCTION MATERIAL AND METHODS TO ADHERE TO FEMA FLOOD PLAIN CONSTRUCTION REQUIREMENTS. PAVERSA M A D O R V A L L E Y B L V D.PARKING LOT16'PARKING LOTSITE PLAN PROJECT DATATRASH ENCLOSURE (COVERED)E A S E M E N T F R O M V I L L A G E P A R K W A YREVISIONSSHEET NO.DATEDRAWN BYNEW RETAIL BUILDINGFax: 510/652-5111A17400 AMADOR VALLEY BOULEVARDDUBLIN CALIFORNIA 945684050 Harlan Street, Emeryville California 94608Beaumont + AssociatesTel: 510/652-4433NEW RETAIL BUILDINGRAMP DN.1:12 SLOPE2RAMP DN.1:12 SLOPE36" HIGH METAL RAILING1'2-STEPS DN.12"MIN. /6"MAX.RUN / RIS2812675' SIDEWALKPROPERTY LINE: 164.77'PROPERTY LINE: 66.00'6' HIGH CMU WALLW/ STUCCO FINISH10' APRONMIN.PROPOSED SITE PLANSCALE: 1/8"=1'-0"16" WIDE X 6' HIGH METAL GATE55' WIDE PLANTER(E) 5' LANDSCAPEDAREA36" WIDELANDSCAPED STRIP3101136" WIDELANDSCAPED STRIPPROPERTY LINE: 69.00'5' SIDEWALKPROPERTY LINE: 176.48'12 NO PARKING36" WIDELANDSCAPED STRIPLINE OF RECESSEDSTOREFRONT (TYP)(E) S.S.9POST DETAILNOTEEV STATION SHALL BE CONTRUCTED WITH THEINFRASTRUCTURE ONLYWALL LATTICE AND METAL TRELLIS TYP.334ACCESSIBILITY RAMP1'-0"3" +/-1"ABOVE RAMP22'-0"19'-2"15'-0"5'-0"5'-0"5'-0" 5'-0"45'-0"3'-0"71'-3" (PROPOSED BUILDING)12'-0"3'-0"3'-0"4'-0"9'-0" TYP.3'-0"75'-0"11'-0"4" DIABOLLARD9'-0" TYP.5'-0"16'-3"100'-4"89'-3" (REAR SETBACK)5'-0"58'-5" (PROPOSED BUILDING)TRASH ENCLOS.DRIVEWAY19'-0"17'-0"12'-0"34"-38" HIGH1 1/2" DIA . STEELRAILING21'-0"DRAINAGE RETENTION AREA3/16" X 2" STEEL WHEEL GUARD EPOXY GROUT3'-0"9'-0" TYP.LANDING72" MIN.5'-0"338.00337.00337.00LANDING28'-10"17'-6"17'-6"6 - 9' X 17'-6' PARKING STALLS1 - 9'X18' ACCESSIBLE STALL4'-0"337.00COMMISSIONED PUBLIC ARWORK.POETRY ENGRAVEMENTIN PAVERS5 - 9'X 17'-6" PARKING STALLSMB12"MIN.12"MIN.34"-38"1 1/2" DIA STEEL POST6"3'-0"55'-0"(PROPOSED BUILDING)24'-0"9'-0" TYP.WHEEL GUARD CENTERED 3" +/-1" ABOVE RAMP11212'-0"72" MIN.ACCESSIBILITY RAMPSEE DETAIL 2/A1MAX CROSS SLOPE: 2%MAX. SLOPE: 5 %DESIGNATED PARKING FOR CLEAN AIR VEHICLESPER CGCSC-DIV 5.106.5 2MAX CROSS SLOPE: 2%MAX. SLOPE:5%EXISTING ADJACENT TRASH ENCLOSUREPLANS SHALL BE REVIEWED BY A INDEPENDANT CERTIFIED ACCESS SPECIALISTPRIOR TO BUILDING PERMIT SUBMITTALCLEAN AIR /VAN POOL /EVELECTRIC VEHICLECHARGING STALLPER CGCSC DIV.5.106.51 LONG TERMBICYCLE PARKINGLOCKER2 SHORT TERMBICYCLE PARKING2 SHORT TERMBICYCLE PARKINGBICYCLE PARKINGPER CGBSC DIV, 5.106.5W/ OVERHANG AT PLANTER W/LOW LYING PLANTS (TYP)W/ OVERHANG AT PLANTER W/LOW LYING PLANTS (TYP)209 SFAWNINGAWNINGAWNINGMAX CROSS SLOPE: 2%MAX. SLOPE:5%ACCESSIBLEPATH OF TRAVEL6'-0"S.B.ACCESSIBILITYPARKING SIGNAGEACCESSIBILITYPARKING SIGNAGEMAX CROSS SLOPE: 2%MAX. SLOPE:5%MAX CROSS SLOPE: 2%MAX. SLOPE:5%ACCESSIBLEPATH OF TRAVELWHEEL STOPTYP.BICYCLE PARKINGPER CGBSC DIV, 5.106.512" STEPCURB..WHEEL STOPTYP.12" STEPCURB..12" STEPCURB..21'-6'X10'CLR. DIM.EVCHARGINGSTATION3'-0"SETBACK10/21/19337.22'337.74'TC337.43FL337.92'TC337.65FL338.14'TC CONC. PAVERS(PERVIOUS SURFACE)TRUNCATEDDOMES337.81'AC FL336.96'AC FL337.345'TC3,578 SF3,578 SF ( F.A.R.)48" WIDE WALKWAYW/ PERVIOUS PAVERS48" WIDE WALKWAYW/ PERVIOUS PAVERS48" WIDE WALKWAYW/ PERVIOUS PAVERS(E ) 10" TALLRETAINING WALL(E) SEWERMANHOLEEL' 337.17'(E ) 6' TALL CONC.CMU WALL(E ) 6' TALL CONC.CMU WALL(E PLANTER STRIP(E PLANTER STRIP(E) DRIVEWAY APRON TO BE REMOVEDPARKING CURB AT ADJACENT PROPERTYEL. 337.75' EL. 339.15' T.O.S.5.1.bPacket Pg. 40Attachment: 2. Exhibit A to Attachment 1: Project Plans (Randeri SDR)
NEW RETAIL BUILDINGTel: 510/652-4433Fax: 510/652-51117400 AMADOR VALLEY BOULEVARDDUBLIN CALIFORNIA 94568NOTE:
THIS BUILDING IS LOCATED IN A FEMA DESIGNATED AO FLOOD PLAIN AND
SHALL UTILIZE CONTRUCTION MATERIAL AND METHODS TO ADHERE TO
FEMA FLOOD PLAIN CONSTRUCTION REQUIREMENTS. 4050 Harlan Street, Emeryville California 94608Beaumont + AssociatesREVISIONS
SHEET NO.
DATE
DRAWN BY
KNOX BOX
PROVIDE SUITE ADDRESS NUMBER
IN CONTRASTING COLORS AT AWNING ABOVE
1. ALL EXIT SIGNS SHALL BE INTERNALLY ILLUMINATED
2. INTERNALLY ILLUMINATED SIGNS SHALL BE LISTED AND LABELED AND SHALL BE
INSTALLED IN ACCORDANCE WITH THE MANUFACURES INSTRUCTIONS AND SECTION 2702.
3. EXIXT SIGN SIGNS SHALL BE ILLUMINATED AT ALL TIMES
4. EXIT SIGN SHALL BE CONNECTED TO AN EMERGENCY POWER SYSTEM THAT WILL PROVIDE
AN ILLUMINATION OF NOT LESS THAN 90 MINUTES IN CASE OF PRIMARY LOSS (1011.6.3).
5. EGRESS DORR SHALL BE READILT OPERABLE FROM THE EGRESS SIDE WITHOUT THE USE
OF A KEY, SPECIAL KNOWLEDGE OF EFFORT. SEE SECTION 411/.1.9 FOR EXCEPTIONS.
6. DOOR HANDLES, LOCKS AND OTHER OPERATING DEVICES SHALL BE INSTALLED AT 34" AND
A MAXIMUM 48" ABOVE THE FINISHED FLOOR.
7. PROVIDE DOOR ABOVE MAIN ENTRY DOOR TO READ: " THIS DOOR TO REMAIN UNLOCKED
WHEN BUILDING IS OCCUPIED".
8. ALL EGRESS DOOR OPERATION SHALL ALSO COMPLY WITH SECTION 1008.1.9 - 1008.1.9.12
A2FLOOR PLANPROVIDE SIGNAGE W/
MAX. OCC. LOAD
SIGNAGE ABOVE DOOR TO READ:
"THIS DOOR TO REMAIN UNLOCKED
WHEN BUILDING IS OCCUPIED"
RM. 107
A5
RM. 103RM. 102
RM. 104 RM. 105
RM. 106
SCALE: 1/4"=1'-0"
FLOOR PLAN
8'-0"
8'-0"
2'-0"10'-0"10'-4"10'-0"42'-3"
6'-6 "6'-4"6'-0"6'-0"8'-3"8'-0"8'-0"6'-0"
8'-0"3'- 0"3'-0"7'-0"13'-6 1/2"MB
B
A
C
2 3 4
D
1
19'-4"19'-4"2'-0"8'-3"19'-4"6'-0"
56'-5"
71'-3"8'-0"8'-0"
2'-0"55'-0"LINE OF CANVASAWNING ABOVELINE OF CANVASAWNING ABOVELINE OF CANVASAWNING ABOVE3578 SF
A
ALL GENDER UTILITY
SERVICE
SINK
ELECT./ TEL.
ALL GENDER ALL GENDER
ALL GENDERALL GENDER
NOTE:
RESTROOM FIXTURE COUNT
AND LAYOUT SHALL BE DETERMINED
PRIOR TO BUILDING PERMIT SUBMITTAL
10/21/19
RETAIL TENANT SPACE
3,582 SF
RETAIL TENANT SPACE
RETAIL TENANT SPACE
KNOX BOX SHALL BE INSTALLE D 5'-6" A.F.F. AND
SHALL BE SIZED TO HOLD THE MASTER KEY TO THE FACILITY AS
WELL AS ROOMS NOT ACCESSIBLE BY THE MASTER KEY.
SPECIALTY KEYS SUCH AS FOR FIRE ALARM CONTROL BOX SHALL
ALSO BE INSTALLED IN THE BOX.
5.1.b
Packet Pg. 41 Attachment: 2. Exhibit A to Attachment 1: Project Plans (Randeri SDR)
CANVAS AWNING (TYP)AEXTERIOR ELEVATIONSNEW RETAIL BUILDINGDALUM. STOREFRONTWINDOW (TYP)SHEILDEDEXT .LIGHT FIXTURESHEILDEDEXT .LIGHT FIXTUREDECO BIKE LOCKERDIM: 76"X33"X48"HNOTE:THIS BUILDING IS LOCATED IN A FEMA DESIGNATED AO FLOOD PLAIN AND SHALL UTILIZE CONTRUCTION MATERIAL AND METHODS TO ADHERE TO FEMA FLOOD PLAIN CONSTRUCTION REQUIREMENTS. CBA7400 DRAWN BYBeaumont + AssociatesREVISIONSSHEET NO.DATETel: 510/652-4433 Fax: 510/652-51117400 AMADOR VALLEY BOULEVARDDUBLIN CALIFORNIA 945684050 Harlan Street, Emeryville California 94608A3SQUARE TUBE BIKE RACKDIM. 36" WIDE, 32" HIGHA5DCBACCESSIBILITY RAMPSCALE: 1/4"=1'-0"RIGHT SIDE ELEVATIONMB10/21/19PROPERTY LINEPROPERTY LINEPARAPETROOF4'-6"25'-0"T.O.S.CANVAS AWNINGT.O.P.28'-0"12'-6"CEM . PLASTER(STUCCO) TYP.REGLET (TYP)STUCCO MOLDINGSTONE BASE (TYP)GALV.MTL. FLASHINGSTUCCO MOLDINGALUM. STOREFRONTDOOR (TYP)METAL TRELLISPROVIDE FLOOD VENTS PER DMC CHAPTER 7.24TYP.AFRONT ELEVATIONSTONE MOLDINGGALV.MTL. FLASHINGSTUCCO MOULDINGSTUCCO MOULDINGA12" MAX.4-0' COVERED ENTRY TYP.4ELECT.METER28'-0"12'-6"25'-0"4'-6"1CEM . PLASTER(STUCCO) TYP.STONE BASE (TYP)23STONE BASE (TYP)REGLET (TYP)STUCCO MOLDINGSCALE: 1/4"=1'-0"CEM . PLASTER(STUCCO) TYP.A5ALUM. STOREFRONTWINDOW (TYP)STUCCO MOLDING(TYP)GALV.MTL. FLASHINGSTUCCO MOLDING5.1.bPacket Pg. 42Attachment: 2. Exhibit A to Attachment 1: Project Plans (Randeri SDR)
A B C
Beaumont + AssociatesREVISIONS
SHEILDED
EXT .LIGHT
FIXTURE
A4EXTERIOR ELEVATIONSSHEILDED
EXT .LIGHT
FIXTURE
SHEET NO.
DATE Tel: 510/652-4433Fax: 510/652-51117400 AMADOR VALLEY BOULEVARDDUBLIN CALIFORNIA 945684050 Harlan Street, Emeryville California 94608D
SHEILDED
EXT .LIGHT
FIXTURE
SHEILDED
EXT .LIGHT
FIXTURE
NEW RETAIL BUILDINGDRAWN BYNOTE:
THIS BUILDING IS LOCATED IN A FEMA DESIGNATED AO FLOOD PLAIN AND
SHALL UTILIZE CONTRUCTION MATERIAL AND METHODS TO ADHERE TO
FEMA FLOOD PLAIN CONSTRUCTION REQUIREMENTS.
SCALE: 1/4"=1'-0"
LEFT SIDE ELEVATION
SCALE: 1/4"=1'-0"
A5A5
REAR ELEVATION
CEM . PLASTER
(STUCCO) TYP.
ALUM. STOREFRONT
DOOR (TYP)
REGLET (TYP)
CEM . PLASTER
(STUCCO) TYP.
GALV.MTL. FLASHING
STUCCO MOLDING
STONE BASE (TYP)
CANVAS AWNING
CEM . PLASTER
(STUCCO) TYP.
STUCCO MOLDING
CEM . PLASTER
(STUCCO) TYP.
GALV.MTL. FLASHING
STUCCO MOLDING
STUCCO MOLDING
WOOD
LATTICE
METAL TRELLIS
WOOD
LATTICE
METAL TRELLIS
STONE BASE (TYP)
METAL
TRELLIS
METAL TRELLIS 28'-0"4 123
ROOF
MB
T.O.P.
PARAPET
25'-0"4'-6"4'-6"25'-0"T.O.S.28'-0"12'-6"9'-1"1
12
4-0' COVERED
ENTRY TYP.
ACCESSIBILITY
RAMP
AA
PROVIDE FLOOD VENTS
PER DMC CHAPTER 7.24
TYP.
12" MAX.
10/21/19
5.1.b
Packet Pg. 43 Attachment: 2. Exhibit A to Attachment 1: Project Plans (Randeri SDR)
RTU
A B C D
NEW RETAIL BUILDINGRETAIL TENANT SPACE
RTU RTU
DATE Tel: 510/652-4433Fax: 510/652-51117400 AMADOR VALLEY BOULEVARDDUBLIN CALIFORNIA 945684050 Harlan Street, Emeryville California 94608A5BUILDING SECTIONSHEET NO.
DRAWN BYBeaumont + AssociatesREVISIONS
BITUMINOUS MEMBRANE
ROOFING O/ 3/4" PLYWOOD
S.S.D.
BUILDING SECTION A-A
SCALE: 1/4"=1'-0"
GALV.MTL. FLASHING
STUCCO MOULDING
STUCCO MOULDING
STEEL COLUMN
PER PLAN STEEL COLUMN
PER PLAN
7/8 CEM . PLASTER
(STUCCO) TYP. 3-COAT APP.
O/2-LAYERD GRADE D PAPER O/
1/2" CDX PLYWOOD O
2X6 FRAMING @ 16" O.C.
W/ R-21 BATT INSULATION
5" CONC. SLAB W/
#4 BAR @ 18" O.C., E.W. O/
MOISTOP O/ 6" SAND18'-9"5'-8"ROOF
T.O.S.25'-0"MB
T.O.PARAPET
A
10/21/19
5.1.b
Packet Pg. 44 Attachment: 2. Exhibit A to Attachment 1: Project Plans (Randeri SDR)
PROVIDE SLOPED FLOOR TO DRAINTYP.A6TRASH ENCLOSURETel: 510/652-4433SLOPETYP.SLOPEREVISIONSSHEET NO.DATEDRAWN BYNEW RETAIL BUILDINGFax: 510/652-51117400 AMADOR VALLEY BOULEVARDDUBLIN CALIFORNIA 945684050 Harlan Street, Emeryville California 94608Beaumont + AssociatesMBNOTE :PROVIDE HOT AND COLD WATER AND DRAIN PER PW DEPARTMENT REQUIREMENTS4X4 12 GA. GALV . MTL COLUMNMETAL GATEMETAL GATEINSTALL INTERCEPTOR PER DSRSD SPECIFICATIONSCORRIGATED METAL ROOFRECYCLING GARBAGE2-#4 BARS HORZ.#4 BARS VERT@ 32" O.C.CONTAINER LAYOUTLEDLIGHTLEDLIGHTGUTTER W/DOWNSPOUT1% SLOPE1% SLOPESCALE: 1/2" =1'-0"SCALE: 1/2" =1'-0"SCALE: 1/2" =1'-0"CEM. PLASTER(STUCCO) O/ 6" CMUFINISH TO MATCH MAIN BUILDING 4X4 12 GA. GALV . MTL COLUMNREAR ELEVATIONSECTION1% SLOPE1% SLOPE1% SLOPEORGANICSFRONT ELEVATIONSCALE: 1/2" =1'-0"6" CMU W/STUCCO FINISH TO MACH MAIN BUILDINGTRASH ENCLOSURE - PLANSCALE: 1 : 10SCALE: 1/2" =1'-0"RIGHT SIDE ELEVATIONLEFT SIDE ELEVATIONCORRIGATED METAL ROOFGUTTER W/DOWNSPOUT6" CMU W/STUCCO FINISH TO MACH MAIN BUILDINGCORRIGATED METAL ROOFCORRIGATED METAL ROOFSCALE: 1/2" =1'-0"DRAIN W/ 4" DIA PIPE TO SANITARY SEWER LINEGUTTER W/DOWNSPOUT8" 12 GA. CHANNEL 6" CMU4" CONC SLAB W/#4 BARS @ 18" O.C. E.W.O / 4" SAND CEM. PLASTER(STUCCO) O/ 6" CMUFINISH TO MATCH MAIN BUILDING CEM. PLASTER(STUCCO) O/ 6" CMUFINISH TO MATCH MAIN BUILDING 1-1.5% SLOPE1-1.5% SLOPE1 % SLOPE1 % SLOPE1-1.5% SLOPE3.0 YDS81"w x 47.5"d x 60h2 YDS81"w x41"d x52"h3.0 YDS81"w x 47.5"d x 60h4X4 12 GA. GALV . MTL COLUMNCORRIGATED METAL ROOFGUTTER W/DOWNSPOUT4X4 12 GA. GALV . MTL COLUMN8" 12 GA. CHANNEL 4" CONC SLAB47 1/2"3" DIA. STEEL BOLLARD(HOSE BIBB PROTECTION )8'-9"7'-0" 81"3'-0"18"7'-0" 7'-0" 21'-0" ( 18'-0" MIN. ) CLR. REQ.22'-6"12"81"41"10' -0" CONC. APRON9'-0" MIN CLR. HEIGHT6"9'-0" MIN CLR. HEIGHT11'-0"9'-0" MIN CLR. HEIGHT10'-0"11'-0"9'-0"9'-0"10'-0" CLEAR3'-3"9'-0"12" MIN.19'-0"16'-0" MIN. CLEAR OPENING1'-6"1'-6"16'-0" MIN. CLEAR OPENING8'-9"8'-9"4" DIA. STEEL BOLLARD1'-6"7'-0" 12" MIN11'-0"1'-6"4" DIA. STEEL BOLLARD18"12"8'-9"7'-0" 81"21'-6"10'-0"12"H.B.(C)H.B.(H)INSTALL LIGHTING -1.0 FOOT CANDLE MINILLUMINATION W/ MOTION SENSOR CONTROLBA6A6BB05/27/196"X6" CURB6"X6" CURB6"X6" CURB1-1.5 % MAX1-1.5 % MAX1-1.5 % MAX1-1.5 % MAX5.1.bPacket Pg. 45Attachment: 2. Exhibit A to Attachment 1: Project Plans (Randeri SDR)
DATE
DRAWN BYNEW RETAIL BUILDINGFax: 510/652-51117400 AMADOR VALLEY BOULEVARDDUBLIN CALIFORNIA 945684050 Harlan Street, Emeryville California 94608REVISIONS
ROOF PLANA78'Beaumont + AssociatesTel: 510/652-4433SHEET NO.
ROOF PLAN
LINE OF RECESSED
STOREFRONT (TYP)
SCALE: 1/4"=1'-0"MB
4" ROOF
DRAIN
ROOF
DRAIN
10/21/19
ROOF
DRAINROOF
DRAIN
ROOF
DRAIN
ROOF
DRAIN
HP-3
HP-2
PARAPET
WALL
PARAPET
WALL
PARAPET
WALL
PARAPET
WALL
PARAPET
WALL
ROOF
DRAIN
HEAT PUMP
UNIT (TYP)
HP-1
BITUMINOUS MEMBRANE
ROOFING
5.1.b
Packet Pg. 46 Attachment: 2. Exhibit A to Attachment 1: Project Plans (Randeri SDR)
4050 Harlan Street, Emeryville California 94608SHEET NO.Tel: 510/652-4433DRAWN BY
TRASH ENCLOSURE
(COVERED)
DATE 7400 AMADOR VALLEY BOULEVARDDUBLIN CALIFORNIA 94568L1
NEW RETAIL BUILDING
RAMP DN.1:12 SLOPEREVISIONS
E A S E M E N T F R O M V I L L A G E P A R K W A YNEW RETAIL BUILDINGFax: 510/652-5111Beaumont + AssociatesA M A D O R V A L L E Y B L V D.PARKING LOT
STEP DN.
STEP DN.
STEP DN.
STEP DN.
STEP DN.RAMP DN.1:12 SLOPEPROPERTY LINE: 66.00'WPLED26
WELL LIGHT DABMAR LV311
RAB
FIXTURE DESCRIPTION MAUFACTURER MODEL COMMENTS
LIGHT POLE
L1 WALL PAK RAB
NOTE
ALL EXTERIOR LIGHTING SHALL BE CONTROLLED BY PHOTO CELLS.
LIGHT FROM FIXTURES SHALL BE SHIELDED.
36" WIDE
LANDSCAPED STRIP
ZONE-1
(243 SF)
ZONE-2
(223 SF)
ZONE-3
(185 SF)
ZONE-7
(82.5 SF)
ZONE-6
(132 SF)
ZONE-5
(223 SF)ZONE-8
(204 SF)
ZONE-10
(8 SF)
ZONE-10
(8 SF)
ZONE-10
(8 SF)
ZONE-10
(8 SF)
ALED26
L2
L3
L4
L5
L6
LANDSCAPE PLANT LIST
LANDSCAPE PLAN
ZONE-4
(344 SF)
EXTERIOR LIGHTING SCHEDULE
36" WIDE
LANDSCAPED STRIP
PROPERTY LINE: 69.00'5' SIDEWALKPROPERTY LINE: 176.48'
NO
PARKING
5' WIDE
PLANTER
5' SIDEWALKPROPERTY LINE: 164.77'
(E) 5' LANDSCAPED
AREA
SCALE: 1/8"=1'-0"
6 8 9 10 11 127
1 2 5 LANDSCAPE PLAN(E) 5' LANDSCAPED
AREA
3 4
LIGHTING POLE W/ PHOTO CELL , SHIELDING, CUT-OFF
L6
LIGHT POLE
WALL LATTICE AND
METAL TRELLIS TYP.
SYMBOL IMAGE
TOTAL 521 SF
PARKING AREA
ZONE-2 = 223 SF
ZONE-3 = 185 SF
ZONE-4 = 344 SF
ZONE-5 = 223 SF
ZONE-6 = 132 SF
ZONE-7 = 82 SF
TOTAL 1,189 SF 1,710 SF
69%30.4%
ZONE 9
(7 SF)
ZONE 9
(14 SF)
ZONE 9
(7 SF)
ZONE 9
(14 SF)
LANDSCAPED AREA TABULATION
BUILDING AREA
ZONE-1 = 243 SF
ZONE-8 = 204 SF
ZONE-9 = 42 SF
ZONE-10 = 32 SF
PLAN NAME WATER USE PLANTING SIZE SYMBOL IMAGE PLAN NAME WATER USE PLANTING SIZE
L6 L6 L6
L6
L6
L6
ATG ELCTRONICS BDW4-15-40-7
WELL LIGHT HINKLEY 1598MZ-RG
FACADE UPLIGHTING TBD
ART
ART
ART
ART
ART
ART
BICYCLE
PARKING
BOLLARD
TREE 2
TREE 2
PERENIAL 1
5 GALLON
VINE 1
GRASS 2
5'-0"
PERENIAL 1 3'-0"GROUND
COVER 1
1 GALLON
24" BOX
GRASS 1
PERENIAL 2
SHRUB 1SHRUB 1
EVERGREEN PEAR
PERENIAL 1
36" BOX
GROUND
COVER 1
PERENIAL 1
PERENIAL 2
DOUGLAS IRIS
IRIS DOUGLASIANA
BOUGAINVILLEA /CALIFORNIA GOLD
SHRUB 1
VINE 1
SHRUB 1
LOW
LOW
SHRUB 2SHRUB 1 SHRUB 1
5 GALLON
PERENIAL 2
PERENIAL 1
PERENIAL 1
GROUND
COVER 1
DRAINAGE RETENTION
AREA
LOW
LOW
LOW
BOUGAINVILLEA
PERENIAL 2
PERENIAL 2
GRASS 1
PERENIAL 1
1 GALLON
RAYWOOD ASH
SHRUB 2
LANSCAPE AND IRRIGATION NOTES:
1.ALL LANDSCAPED AREAS SHALL BE DRIP IRRIGATED
2.WATER USED FROM LANSCAPING SAHLL BE RECYCLED WATER.
3.ALL PLANTS SHALL BE DROUGHT RESISTANT PER THE DOWNTOWN DUBLIN SPECIFIC PLAN.
PERENIAL 1
TREE 1
TREE 2
PERENIAL 1
SHRUB 1
PERENIAL 2
BACK FLOW
PREVENTER
GRASS 1
PERENIAL 1
GROUND
COVER 1
MB
TREE 1
TREE 1
TREE 1
SHRUB 1SHRUB 1
TREE 2
TREE 2
VINE 1
15" MIN.
GRASS 1
MYRSINE AFRICANA
ELYMUS CONDENSATUS
CANYON PRINCE/ WILD RYE
BLUE FESCUE
FESTUCA GLAUCA
15" MIN.
VINE 1
RHAMNUS CALIFORNICA
AFRICAN BOXWOOD
1 GALLON
1 GALLON
FRAXINUSANGUST ANGUSTFOLIA
GRASS 2
SHRUB 1
SISYRINCHIUM ANGUSTIFOLIUM
BLUE EYED GRASS
PERUVIANA VERBENA
VERBENA PERUVIANA
TREE 1
LOW
LOW
LOW
GRASS 1
GRASS 2
PYRUS KAWAKAMII
5'-0"
337.00GROUND
COVER 1
LOW
CALIFORNIA COFEEBERRY
GROUND
COVER 1
GROUND
COVER 1
SHRUB 1
SHRUB 2
MODERATE
TREE 2
ACCESSIBILITY
PARKING SIGNAGE
WHEEL
CURB TYP.
AWNING
MAX CROSS SLOPE: 2%
MAX. SLOPE:5%6 "CURB
WHEEL
CURB TYP.
MAX CROSS SLOPE: 2%
MAX. SLOPE:5%
EXISTING ADJACENT
TRASH ENCLOSURE
ACCESSIBLE
PATH OF TRAVEL
12" STEP
CURB..
12" STEP
CURB..
EV
CHARGING
STATION
ACCESSIBLE
PATH OF TRAVEL
MAX CROSS SLOPE: 2%
MAX. SLOPE:5%
MAX CROSS SLOPE: 2%
MAX. SLOPE: 5 %
MAX CROSS SLOPE: 2%
MAX. SLOPE: 5 %
MATERIAL LEGEND
LANDSCAPED AREAS
48" METAL
BENCH
10/21/19
BUILDING AREA
CONC. PAVERS
(PERVIOUS SURFACE)
L1
L2
L2
L2
L2
L2 L2
L2L2
L4
L1
L1
L3
L3
L3
3'X3' CONC. PAVERS
PERVIOUS
CONCRETE
L5L5L5
L5
L4
CONC. PAVERS
(PERMIEABLE SURFACE)
CONC. PAVERS
(PERMIEABLE SURFACE)
PERVIOUS
ASPHALT
48" WIDE WALKWAY
W/ PERVIOUS PAVERS
3,578 SF ( F.A.R.)
48" WIDE WALKWAY
W/ PERVIOUS PAVERS
3,578 SF
(E PLANTER
STRIP
(E PLANTER
STRIP
(E PLANTER
STRIP
(E PLANTER
STRIP
5.1.b
Packet Pg. 47 Attachment: 2. Exhibit A to Attachment 1: Project Plans (Randeri SDR)
5.1.b
Packet Pg. 48 Attachment: 2. Exhibit A to Attachment 1: Project Plans (Randeri SDR)
5.1.b
Packet Pg. 49 Attachment: 2. Exhibit A to Attachment 1: Project Plans (Randeri SDR)
5.1.b
Packet Pg. 50 Attachment: 2. Exhibit A to Attachment 1: Project Plans (Randeri SDR)
5.1.b
Packet Pg. 51 Attachment: 2. Exhibit A to Attachment 1: Project Plans (Randeri SDR)
C5
5.1.b
Packet Pg. 52 Attachment: 2. Exhibit A to Attachment 1: Project Plans (Randeri SDR)
SHEET NO.
DATE
3/4" GAS3/4" GAS
4" SS 4" SS
TRASH ENCLOSURE
(COVERED)
PARKING LOT
PAVERS
PAVERS
NEW RETAIL BUILDING
Beaumont + AssociatesE A S E M E N T F R O M V I L L A G E P A R K W A YWMWM
RAMP DN.1:12 SLOPE4050 Harlan Street, Emeryville California 94608LOT AREA =11,073 SF
REVISIONS
4" SS 4" SS Tel: 510/652-4433RAMP DN.1:12 SLOPE36" HIGH METAL
RAILING
1" W
1A M A D O R V A L L E Y B L V D.PARKING LOT
DRAWN BYNEW RETAIL BUILDINGFax: 510/652-51114" SS
ELECT.
METER
BUBBLE UP
PRELIMINARY UTILITY PLAN3/4" GAS
U1
C.O.7400 AMADOR VALLEY BOULEVARDDUBLIN CALIFORNIA 94568L6
L6
PRELIMINARY UTILITY PLAN
LINE OF RECESSED
STOREFRONT (TYP)
4
PROPERTY LINE: 176.48'
12 NO
PARKING 75' SIDEWALK1" WATER LINETO VILLAGE PARKWAYWPLED26
WELL LIGHT DABMAR LV311
RAB
FIXTURE DESCRIPTION MAUFACTURER MODEL COMMENTS
L1 WALL PAK
2
RAB
NOTE
ALL EXTERIOR LIGHTING SHALL BE CONTROLLED BY PHOTO CELLS.
LIGHT FROM FIXTURES SHALL BE SHIELDED.
ALED26
L2
L3
L4
L5
L6
EXTERIOR LIGHTING SCHEDULE
LIGHTING POLE W/ PHOTO CELL , SHIELDING, CUT-OFF
1
10 11
PROPERTY LINE: 164.77'PROPERTY LINE: 66.00'6
SCALE: 1/8"=1'-0"5' SIDEWALK(E) S.S.9
3
PLANTER
(E) 5' LANDSCAPED
AREA
PLANTER
5' WIDE
PLANTER
8
5
L6
BICYCLE
PARKING PROPERTY LINE: 69.00'ATG ELCTRONICS BDW4-15-40-7
WELL LIGHT HINKLEY 1598MZ-RG
FACADE UPLIGHTING TBD
BOLLARD
L6 L6
5'-0"
16'-3"3'-0"5-4" DIA ELECT.
SERVICE CONDUITS
BACK FLOW
PREVENTER
5'-0"
331.16'
INV 6IN.
DRAINAGE RETENTION
AREA
GAS METER
58'-5" (PROPOSED BUILDING)
TEL.
100'-4"
89'-3" (REAR SETBACK)71'-3" (PROPOSED BUILDING)
337.00
400 AMP
TRANSFORM.
MB
EXISTING ADJACENT
TRASH ENCLOSURE
WHEEL STOP
TYP.
MAX CROSS SLOPE: 2%
MAX. SLOPE:5%
AWNING
AWNING
6'-0"
S.B.
1'-0"
SETBACK
6 "CURB
L2
L3
L3
L2
TRUNCATED
DOMES
10/21/19
L3
L2
L1
L2L2
L2
L2
L4
L4
L1
L1
L5 L5337.93'L5337.43FL 337.65FL 338.14'TC
337.92'TC
L2 L5L5L5
L3 336.96'AC FL
48" CONC. WALKWAY
3,613 SF
FF = 338.50'
PAD = 337.59'.
(E ) 6' TALL CONC.
CMU WALL
(E) DRIVEWAY
APRON
PARKING CURB AT
ADJACENT PROPERTY
(E PLANTER
STRIP
(E PLANTER
STRIP
(E) DRIVEWAY
APRON
TO BE REMOVED
EL. 335.5'
(E ) 6' TALL CONC.
CMU WALL
(E) SEWER
MANHOLE
EL' 337.17'
EL. 335.5'
5.1.b
Packet Pg. 53 Attachment: 2. Exhibit A to Attachment 1: Project Plans (Randeri SDR)