HomeMy WebLinkAbout04-050 Richardson Setback CUPAGENDA STATEMENT
PLANNING COMMISSION MEETING DATE: February 8, 2005
SUBJECT: PUBLIC HEARING - PA 04-050, Richardson Utility/Garden
Shed Conditional Use Permit for an Accessory Structure with an
Exception from Side Yard Setback Requirements
Report prepared by: Pierce Macdonald, Associate Planner .~'"
ATTACHMENTS: 1. Resolution to Deny a Conditional Use Permit for an
Accessory Structure with an Exception from Side Yard
Setback Requirements (with Project Plans attached as
Exhibit A)
2. Written Statement
3. Dublin Residential Accessory Structures Pamphlet
4. Vicinity Map
5. Zoning Ordinance Section 8.40.020(F)(2)
6. Site Photographs
RECOMMENDATION: 1. Open the Public Hearing and hear Staff presentation;
2. Receive presentation from the Applicants;
3. Receive comments from the Public;
4. Close the Public Hearing and deliberate; and
5. Adopt Resolution (Attachment 1 with Project Plans attached
as Exhibit A) to deny the Conditional Use Permit for an
Accessory Structure with an Exception from Side Yard
Setback Requirements.
PROJECT DESCRIPTION:
The Applicants, Mr. and Mrs. Richardson, are requesting a Conditional Use Permit to allow a utility shed
accessory structure with a modified side yard setback, pursuant to Section 8.40.020(F)(2) of the Zoning
Ordinance. In 2004, the utility shed's non-conforming setback was identified during a plan check review
of an addition to the Richardson residence on the site. The shed was constructed on the lot with a side
yard setback of two (2) feet and two (2) inches where five (5) feet is required pursuant to Zoning
Ordinance requirements in Section 8.40.020(F)(2)(h). (Project Plans are attached as Exhibit A to
Attachment 1.)
According to the Applicant's Written Statement included as Attachment 2, Mr. Richardson believed that
when he began the project in 2002, the shed met all City requirements because of the information in a
pamphlet he obtained from the Building and Safety Division. The pamphlet on residential accessory
structures that he refers to (Attachment 3) references only Building Division requirements for construction
and permitting of accessory structures, and recommends that Applicants contact the Planning Division for
zoning regulations. The Applicants are requesting the Planning Commission's approval of a Conditional
Use Permit to allow them to retain the shed with the current nonconforming side yard setback.
COPIES TO: Applicants
PA File
Project Manager ~
ITEM NO.
The site is located at 7230 Dover Court near Dover Lane (see Attachment 3, Vicinity Map). The site is
zoned Single-Family Residential Zoning District (R-1). The subject lot is rectangular in shape and 6,501
square feet in size. The utility shed is considered an accessory structure under Section 8.40 of the Zoning
Ordinance.
The utility shed structure is 8 feet wide by 12 feet deep for a total of 96 square feet of enclosed floor area.
The southern face of the shed is 2 feet and 2 inches from the side property line and 22 feet from the front
property line, behind a 6-foot fence. The utility shed has a simple gable roof, and the structure measures
approximately 10 feet in height. There is one door on the west elevation facing the Richardson's
residence, an attic vent on the sides, and no other openings on the building (see Exhibit A of Attachment
1). The shed is 7 feet and 9 inches from the room addition built with valid building permits and 2 feet and
6 inches from the original portion of the residence. The utility shed will be used for storage and for
gardening purposes, as well as for other maintenance projects. There is currently no electricity or
plumbing to the building.
ANALYSIS:
The Applicants are requesting an exception from standards (required setback 5 foot) for the south side
yard adjacent to the structure to 2 feet and 2 inches. Pursuant to Zoning Ordinance Section 8.40.020(F)(2)
(see Attachment 4), a Conditional Use Permit may be granted by the Zoning Administrator to allow a
modification or exception from setback requirements if the findings for a Conditional Use Permit can be
made. The Zoning Administrator may choose to refer any application to the Planning Commission
pursuant to Section 8.96.020(C)(2) of the Zoning Ordinance. Based on conversations with the Applicants
during the Code Enforcement process, the Zoning Administrator determined that it was in the best
interests of the City to transfer authority to the Planning Commission under this Section.
In reviewing the project application, Staff has reviewed issues of design and health and safety relative to
the location of the shed on the property as required by Section 8.100.060 of the Zoning Ordinance. These
issues are analyzed in the following sections.
Design:
Staff reviewed the form and massing of the utility shed structure in relation to the neighborhood to
determine its impact on the adjacent properties. The shed would be approximately 22 feet from the front
property line. No windows facing adjacent properties are proposed that could impact privacy. However,
the gable roof and the back wall of the structure are above the six-foot fence at 10 feet, and can be viewed
from the street. No other similar structures are located in the neighborhood. (See Site Photographs in
Attachment 5.)
Health and Sa ety:
The Building and Safety Division reviewed the application and determined that a Building Permit is not
required for construction of the shed as it is under 120 square feet in size; however, the southern wall does
not meet fire code requirements of the Uniform Building Code as it is not a 1-hour fire-rated wall and is
located too close to the adjacent property for fire safety purposes.
Conditional Use Permit Findings:
Pursuant to the purposes and intent of the Single-Family Residential District, Chapter 8.20, and the
2
requirements of Conditional Use Permits, Chapter 8.100, the finding that an exception from the standard
side yard setback requirements for the accessory structure is not compatible with the residential uses in the
vicinity should be made. Staff recommends that the proposed use be denied based on the following
determinations:
1. The size of the utility shed is not typically associated with Single-Family Residential
neighborhoods because it is four (4) feet taller than the property's fence and it is highly visible
from the Dover Court public right-of--way; and
2. The design of the utility shed will impact the safety of adjacent neighbors because the southern
wall of the shed is not 1-hour fire-rated pursuant to Uniform Building Code requirements related
to fire hazards.
ENVIRONMENTAL REVIEW:
The California Environmental Quality Act (CEQA), together with the State guidelines and City
environmental regulations require that certain projects be reviewed for environmental impact and that
environmental documents be prepared. The project has been found to be Categorically Exempt from the
California Environmental Quality Act (CEQA), according to Section 15301(1) because the project consists
of minor modifications to an existing developed lot; it is consistent with all General Plan and Zoning
regulations of the City; and, it is currently served by all required utilities and public services.
CONCLUSION:
The Applicants, Mr. and Mrs. Richardson, are requesting a Conditional Use Permit to legalize the existing
utility shed and to allow the modification of a setback requirement under Chapter 8.40, Accessory
Structures and Uses Regulations, of the Zoning Ordinance. The findings for denial of the Conditional Use
Permit, contained in the Resolution (Attachment 1), can be made as the utility shed is highly visible from
the Dover Court public right-of--way; and the shed does not meet minimum fire safety requirements of the
Uniform Building Code.
RECOMMENDATION:
Staff recommends the Planning Commission: 1) open the Public Hearing and hear Staff presentation; 2)
receive presentation from the Applicants; 3) receive comments from the Public; 4) close the Public
Hearing and deliberate; and, 5) adopt the Resolution (Attachment 1 with Project Plans attached as Exhibit
A) to deny the Conditional Use Permit for an accessory structure with an exception from side yard setback
requirements.
G:\PA#12004\04-0501PC Staff Report 2-8-OS.doc
3
GENERAL INFORMATION:
PROJECT:
PA 04-050 Richardson Utility Shed Conditional Use Permit for
Accessory Structure with a Modified Setback
PROJECT DESCRIPTION: The Applicants are requesting a Conditional Use Permit to legalize
an accessory structure with an exception from side yard setback
requirements, pursuant to Section 8.40.020(F)(2) of the Zoning
Ordinance.
ENVIRONMENTAL REVIEW: The project has been found to be Categorically Exempt from the
California Environmental Quality Act (CEQA), according to Section
15301(1) because the project consists of minor modifications to an
existing developed lot.
APPLICANTS AND Darren and Monique Richardson
PROPERTY OWNERS:
LOCATION: 7230 Dover Court, Dublin 94568
APN: APN 941-0197-056
GENERAL PLAN Single-Family Residential
DESIGNATION:
EXISTING ZONING Single-Family Residential, R-1
AND LAND USE:
4
RESOLUTION NO. 05 -
A RESOLUTION OF THE PLANNING COMMISSION
OF THE CITY OF DUBLIN
TO DENY A CONDITIONAL USE PERMIT FOR AN ACCESSORY STRUCTURE
WITH AN EXCEPTION FROM SIDE YARD SETBACK REQUIREMENTS
LOCATED AT 7230 DOVER COURT, APN 941-0197-056 (PA 04-050)
WHEREAS, the Applicants, Mr. and Mrs. Richardson, have requested a Conditional Use Permit
to legalize an accessory structure consisting of a shed (96 square feet and 10 feet high) with an exception
from the required 5-foot side yard setback to a setback of 2 feet and 2 inches at 7230 Dover Court (APN
941-0197-056), pursuant to Zoning Ordinance Section 8.40.020(F)(2); and
WHEREAS, the California Environmental Quality Act (CEQA), together with the State
guidelines and City environmental regulations require that certain projects be reviewed for environmental
impact and that environmental documents be prepared, and the project has been found to be Categorically
Exempt from CEQA, according to Section 15301(1) because the project application request consists of
minor modifications to an existing developed lot; and
WHEREAS, the Planning Commission held a public hearing on said application on February 8,
2005; and
WHEREAS, proper notice of said public hearing was given in all respects as required by law; and
WHEREAS, a staff report was submitted to the Planning Commission recommending the
Planning Commission deny the Conditional Use Permit; and
WHEREAS, the Planning Commission did hear and consider all said reports, recommendations
and testimony herein above set forth and used its independent judgment to make a decision; and
WHEREAS, the Planning Commission has found that the proposed accessory structure is not
appropriate for the subject site as located within the required side yard setback.
NOW, THEREFORE, BE IT RESOLVED THAT the Dublin Planning Commission does find
that pursuant to the purposes and intent of the Single-Family Residential District, Chapter 8.20, and the
provisions and requirements of Conditional Use Permits, Chapter 8.100, and Accessory Structures &
Uses, Chapter 8.40, the proposed accessory structure is not compatible with other land uses, transportation
and service facilities in the vicinity; and the site is not physically suitable for the type, density, and
intensity of the use and related structures because of the following facts:
1. The size of the utility shed is not typically associated with Single-Family Residential
neighborhoods, because it is four (4) feet taller than the property's fence and it is highly visible
from the Dover Court public right-of--way; and
2. The design of the utility shed will impact the safety of adjacent neighbors because the southern
wall of the shed is not 1-hour fire-rated pursuant to Uniform Building Code requirements related
to fire hazards.
ATTACHMENT 1
BE IT FURTHER RESOLVED THAT THE Dublin Planning Commission does hereby deny
PA 04-050, Conditional Use Permit for a utility shed accessory structure with an exception from a
required side yard setback, located at 7230 Dover Court, APN 941-0197-056, as depicted on project plans
attached as Exhibit A to this Resolution.
PASSED, APPROVED and ADOPTED this 8`h day of February, 2005.
AYES:
NOES:
ABSTAIN:
ABSENT:
Planning Commission Chairperson
ATTEST:
Planning Manager
G:\PA#12004\04-050 Richardson Shed CUP\CUP reso.doc
2
~J
~..
T p i p O `- fi n„
~ ^
~ c °5 - a
l ° _ 0 0 0 ~c ~ r~ ~c
_ w ~ ~
? " ~. ~., ^ N ~ C
,°~ w ~ c
y° '~ z ~'
'. Y .o
o l
~ A ~ ~ <
~
~%
N `
.
_
.
~~ ~ ~ C N
W
~ O ~ .~T l4
~ d O
~ ~ f:
o 'd 5' 2
~ ~ `\
\
a $
d
a w , ~
n
ti
~
~
~ oar ~~~~~ o~.
k ~ \\\\ ~ n
ti ~ ~ ~ ~ O
\\\\ ', ~ O
~ ~
~ ~ ~ • ~.
~
~
~ ~
~ ~
moo ~ O
'~ = a oa
~ ~ ~~
~
~
~~
~.
~
w~
~
M ~~
~ ~w
~
`
o ~~
~o
~~
~~
0
a~
4
~X~I~1T
bCy
c~
~7
ti
~_
O
c~
co
B
'`
\\
~ t~
w
~.
- ~
co
~o
c~
ti
~
o
O 00 ~
0 ~
. ~
c~
._
~~
~_
~-~
K
-~
Z
b
~ o'
o ~'
N
N
~ o
~ ~
~ ~
n ~
y ~ ~\
t(Yrl " 1
A-!
V
~j
c
~~
.~
-~
ti
~ b
~ ~
sZ, _
d
~' . ~
~ ~
~ ~ ~ o
.
ti co ~ co ~.
~`,,~
ti ~
~~ k
~ ~,
~
o ~ ~ ~ ti.
'
N ~ ~
co
~
~ ~
~ ~
'~
~.
~ o
~ ~ ~
o s
~
~ ~
c o
~
~ o
~' ~ `°
j _
~ ~ ~
~
co •
~ \\\
l~G
~, ~ ~~
O ~V
~ ~
~
~ `
,
iU
V 0
'
O
~
~ ~
~
~ ~
-~
c~ x
~ ~
~
~c
o~ ~
_~
_~
O
~
~.
~ ~
'
m
~
~~
z
l1 l
®~~ I n
%'
__ co < 'b
~ ' ! ~ ~
~ "" ~
'b
~
~.
l ~ ~
~ ~ o
~
~` ~•
~
O
(
~
Ai lv ~•
ti_
n
ti
~
•
J ~~
( ~
~~
O
O
T
`V
~
~
/ k ~ ~
~ ~ k
'
/ ~ ~ ~
~ ~
~ ~ ti
~ ~'
~ = °'a
~~
~ ~
~
~~ N
o `~°
~
" ~ ~
•
~ ~ co
~.
~ ~ ~
o
o
o
~ ~.
00 -V , U5 rlrUb Ur'rl7 rrVrl rrnlr lV rrnlr
s
u
6
s
te
a,
c ~
i
~a
N ~'
O
a
O
L
'
'
7
-0
, approx. ~ on existing
fence between adj cent property
in
N ~
N
Y
6
3 :; •
:;
a
N
0
u
...:..::.:. .........
c
4 :0 7'-9'
c
0 ~
~ ~ 4 - ~~~~
i
r`
L
j 3
N
6
6'-0
i d
I E
p
N
~ d
~O
i N
N
i
0~
2'_2• fU
Tool Shed
Requested changes for resubmittal. _ _
Showing accessory structure along south property line.
Structure is a 96 sq. ft. tool shed.
There are no electrical, plumbing or mechanical
installations to this structure.
RECEIVED
SFPl~ 2004
t?UBLIN PLANNING
~iECE1VED
10/ 13/2004 L~ C r i 4 2oa~
City of Dublin
Conditional Use Permit Request for Existing Shed
DUBLIN PLANNING
I, Darren Richardson, along with my wife Monique Richardson, homeowners and occupants of 7230
Dover Court in the City of Dublin, would like to request that the City of Dublin grant us a Conditional
Use Permit for our existing shed structure. This structure lies on the southern side of our property along
the property line of our neighbors at 7224 Dover Court.
This shed is used for storing gardening and construction tools or materials for such tasks. We built the
shed to compliment our house and provide a quality structure for storing our tools and materials.
The reasons we feel this application should be approved are the following.
Before we built the shed, I had been to the City of Dublin regarding an add-on that we were progressing
on at the time. I was discussing the plans with a plan checker when she directed me to a rotating
pamphlet/handout rack behind me near the Planning Desk. She had pointed this out to me to reference a
pamphlet concerning bathroom specifications and code with respect to the add-on plans at the time.
While looking at the bathroom pamphlet I noticed a handout on residential accessory structures. This
included requirements for building a shed. This was nearly two years ago and had not changed up to the
date of receiving a building permit for the add-on that we are currently working on. I was considering
removing the existing and dilapidated aluminum shed and building a replacement shed so I picked it up.
This handout indicates that we need no permit for constructing a shed as long as it is less than 120 sq. ft.
The resulting shed is only 9b sq. ft. 1 built this shed on a concrete slab with standard wall framing and
4/12 roof construction. This handout also never indicates that there are height-to-property-line
requirements, which are on a separate pamphlet that was unknown to us at the time. The separate
pamphlet references the handout that I have, but my handout never references the other pamphlet.
Because of the lack of reference I never knew to consider the height requirements. We had no knowledge
of the other pamphlet until after we submitted our add-on plans to the City of Dublin.
Our shed only breaks the height requirements due to its pitched roof All four corners are at the required
eight feet max for our less then five feet proximity to our property line. This error was discovered and
brought to our attention during the planning checks for our current add-on project.
We feel that we built this shed in good faith based on the documentation provided by the City of Dublin
for Residential Accessory Structures. We do not deny that this was certainly an honest mistake by the
City of Dublin and that the City of Dublin did not intentionally mislead us. However, we feel that we
made every effort to be in compliance and certainly thought that we were. It is our hope that the City of
Dublin will consider our plea and accompanying letters of support from our neighbors and grant us a
Conditional Use Permit for our shed, as it exists. Our neighbors have expressed admiration at the
construction of our shed and we have had nothing but compliments about its aesthetics. We have had no
complaints about our shed from any neighbor. This would prevent us from having to bear the expense
and labor of tearing down and rebuilding much of our shed for what was simply an honest mistake.
Darren & Monique Richardson
ATTACHMENT .2
J ~~~
~~'
~~V
CITY OF DUBLIN • BUILDING 8s SAFETY DIVISION
100 Civic Plaza, Dublin, California 94568
RESIDENTIAL ACCESSORY STRUCTURES
(PATIO COVERS • SHEDS • ARBORS • 'TRELLISES)
Construction Plan Submittal Requirements
Website: http:/lwww.ci.dublin.ca.us
Phone: (925) 833-6620
Fax: (925) 833-6628
Pursuant to Section 7.28.280 of the Dublin Municipal Code, a permit is required for any alteration or repair work
to any building or structure. Therefore, a building permit is required for the installation of any attached
residential accessory structure such as a covered patio, gazebo, shade structure and unenclosed structure. It is
also required for the installation of any detached tool/storage shed, playhouse or similar use greater than 120
sq. ft. in floor area*; for the installation of any detached lath house, trellis or arbor with a roof that does not shed
water, and is less than 1,000 sq. ft. in area*.
A plan approval must therefore be obtained from the Planning Division and Building ~ Safety Division before
commencing any work for the construction of an accessory structure, including any electrical, plumbing and
mechanical installations in such buildings. The following procedure must be obtained in order to process and
approve plans for construction:
1. Three (3) complete sets of plans must be submitted, a building application form completed, a "Patio Cover
and/or Enclosure Declaration" (if applicable} signed by property owner, and the required plan check fee
paid.
2. Upon submittal of plans, they will be distributed to the different divisions and reviewed according to the
zoning and building regulations. The Planning Division will review plans for conformance to zoning
regulations such as location to main building, setback to property lines and other structures, size, height,
and allowable building coverage of the lot. The Building & Safety Division will review plans for conformance
to the building code such as structural attachments, framing details, building height, light and ventilation
requirements, electrical connections, grounding, listed materials, etc.
Note: It is highly recommended for the applicant to verify That all zoning regulations are in
compliance prior to filing for a building permit application. Please contact the Planning Division for
specific information regarding your lot size and maximum height and setback dimensions.
3. Once the plans have been reviewed and approved by all the divisions, a building permit will be issued to the
applicant (licensed contractor, property owner or owner's agent only) at the Building counter. Permit fee
information may be requested in advance by calling the Building & Safety Division staff at (925) 833-6620,
Monday through Friday, between 7:00 A.M. to 5:00 P.M.
4. One set of approved plans will be returned to the applicant to be maintained at the construction site until the
final inspection has been made. The Building & Safety Division will keep a second set cn file until
construction has been completed. The third set will be forwarded to the Assessor's Office.
*Dublin 'Municipal Code: 7.28.290 -Exceptions: \o permit shall be required for the following; however, permits shall
be required fer electrical, plumbing and mechanical installations in any building or structure listed as follows:
• One-story detached accessory buildings used as tool and storage sheds, playhouses and similar uses.. pro~~ided the floor
area does not e~cceed 120 sq. ft.
^ Lath houses and similar sun shade structures with roofs which do not shed water. which are more than ten (10) feet in
height and 1,000 sq. ft. in area. [Structures must be detached from the main house.
Scope of work only involves a concrete slab only.
G:'.Handouts`.Residential Accessory Structures.duc
Page 1 of'_
Last Revised 1? ~ i ?OG'
ATTACHMENT 3
Minimum Requirements for Construction Plans
A. All plans shall be drawn on no smaller than 17 x 22 inch paper, to scale (i.e., site plan: 118" = 1'-
0", floor plan: '/4" = 1'-0") in a concise, detailed and professional manner. Single line floor plans
are not acceptable; inadequate plans will be rejected. Included on the plans shall be the following
information:
1. Cover sheet -job address; name, address and phone number of owner, contractor and
contact person; description of work including new building and/or structure square footage.
2. Plot plan -proposed building and existing condition of main structure location indicating all
setback distances to main house and to rear and side property lines; north arrow; location of
easements and other utilities.
3. Floor plan - (when applicable) dimensioned floor plan identifying proposed room use(s);
door/window keynotes and schedule; exterior landing dimensions; electrical schematic
diagram locating any proposed receptacle outlets, interior and exterior lighting fixtures,
switches.
4. Elevations -minimum of two exterior elevations identifying construction materials, colors, wall
and roof covering specifications, maximum building height from ground level.
5. Cross-Section drawing -complete building cross-section depicting wall framing, positive
connections of wall to foundation, wall to roof and framing connection at roof ridge.
6. Foundation plan -dimensioned plan identifying type of foundation system with footing/slab
detail references and reinforcement details.
7. Floor and Roof Framing plans - (when applicable) complete floor and roof framing plans
identifying type of framing members, span, spacing and referenced construction details with
framing attachments.
8. All the provisions for patio covers shall be in conformance with Appendix Chapter 31, Division
III which include the following minimum requirements (refer to the 1997 UBC, Vol. I, for
complete listing):
• One-story structures only
• Maximum 12' in height
• Open area of longest wall of enclosure wall shall be at least 65% of the area, below 6'-8"
min.
• Openings may be enclosed with insect screening or plastic that is readily removable
translucent or transparent plastic, 0.125" in thickness - no glass windows allowed
• Structure shall be used only for recreational, outdoor living purposes and not as carports,
garages, storage rooms or habitable rocros
• Bedroom windows with emergency egress windows shall not exit into patio enclosures;
these shall be relocated to open directly to the street, public alley, or yard
• Structure shall be designed and constru~;ted per Chapter 16, Volume II of the 1997 UBC
• Structure may be supported on a minimum 3-1/2" thick concrete slab on grade without
footings, provided that the columns do rot support live and dead loads in excess of 750-Ib
per column
• "Patio Cover and/or Enclosure Declaration" form shall be submitted and signed by property
owner prior to permit issuance.
B. If the proposed patio cover is constructed based on an approved industry "listing number" such as
an I.C.B.O. Evaluation Report number (or other approved listing), conformance to the above listed
items has already been reviewedlapproved; however, zoning regulations still need to be met. Only
two (2) complete sets of the listing report or specification sheets need to be submitted.
G:\Handouts\Residential .Accessory Structures.doc
Last Revised 1''/311200=
Page ? of 2
`-t
k 4..
wp ~*. 7~ ~ ~ ~~ `r~f,~ _#, ~.
:~ ~ ' t4
.. ~ ? ' *~
~ . ~ ~.`. w
'~ ?~ ~
~il1l. ~ ~~ ~ ~ .~
~ £~ ~~.
~, ~ ., ~ ~
~~ ~~ ,i
"~ 'o ~~ ` ~
~ ,~:.~
C 1~ Ts ~ cs
" ""' 1 ~-~
~?, ~ ~
t
~'~_
~~ ~~~ ,~
~ ~
;{ t ~,
;~"~
.5 ~ $ ~ ~ 15
i r ~
w ~~~ ii
~~ ~.~ r.~
~ ~ s~
`' ' ~, ~~ ti ~{{~,},- ~ `~~
~. ~ i4~ ~sA '.. ~ A"~~95
VICINITY MAP
7230 Dover Court
't
s 7
ATTACHMENT 4
ACCESSORY STRUCTURES AND USES REGULATIONS
Chapter 8.40
CHAPTER 8.40 ACCESSORY STRUCTURES AND USES
REGULATIONS
8.40.010 Purpose. The purpose of these provisions is to establish the regulations that apply to
accessory structures, and to specify the uses that are permitted as accessory to the
principal uses in the zoning districts.
Intent. The intent of these provisions is to ensure the compatibility of accessory
structures and uses with permitted structures and uses.
8.40.020 Accessory Structures
A. Accessory Structures Included With Permitted Uses. In addition to the principal
structures associated with permitted Use Types, each Use Type shall be deemed to include
such accessory structures which are specifically identified by these Accessory Structures and
Uses Regulations, and to include such other accessory structures which are necessarily and
customarily associated with, and are appropriate, incidental, and subordinate to, such
principal structures. It shall be the responsibility of the Director of Community Development
to determine if a proposed accessory structure is necessarily and customarily associated with,
and is appropriate, incidental, and subordinate to the principal structure, based on the Director
of Community Development's evaluation of whether the proposed accessory structure is
necessarily or customarily associated with the Use Type for which the development was
constructed. Determinations by the Director of Community Development shall be subject to
appeal pursuant to Chapter 8.136, Appeals, and a record of all such determinations shall be
maintained by the Director of Community Development.
B. Accessory Structures Subject to Regulations. Accessory structures shall be regulated in the
same manner as the principal structures within each zoning district, except as otherwise
expressly provided in these regulations.
C. General Requirements
1. Attached Structures. If an accessory structure is attached to a principal structure, it
shall be made structurally a part of the principal structure and shall comply with all the
requirements of this Title to the principal structure.
2. Breezeways. A breezeway or other extension of the principal structure or accessory
structure roof may connect the accessory structure to the principal structure, but it
shall not be considered part of the principal structure. The breezeway and accessory
building must meet principal building setbacks.
City of Dublin Zoning Ordinance 40-1 September, 1997
Amended January 20, 2004
ATTACHMENT 5
ACCESSORY STRUCTURES AND USES REGULATIONS
Chapter 8.40
3. Height. Detached accessory structures, unless specified otherwise in this Chapter,
shall have a maximum height of 15 feet. Detached accessory structures in the
Agriculture zoning district shall have a maximum height of 15 feet except for barns
which may be 2 stories high if the upper story is designated only for storage of hay
and agricultural supplies.
4. Inhabitable space. Accessory structures, with the exception of Guesthouses and
Second Units shall not be constructed so as to provide year-round inhabitable space.
Rev. Ord. 16-02 (November 2002)
5. Location of Accessory Structure. Accessory structures shall be located on the same
lot as principal use.
6. Maximum enclosure of gazebo or patio cover. A gazebo, patio cover, or other
similar enclosure constructed of lattice, or equivalent material through which air and
light can pass, shall be constructed so that 80% of each side, which is not attached to a
principal structure, is open and not inhabitable on a year-round basis.
7. Public Works Setbacks. No accessory structure shall be located between the Street
right-of--way line and a Future Right-of--Way Line.
S. Separation of detached accessory structure from other structures on the same lot.
The distance of a detached accessory structure from any other structure on the same
lot shall be as determined by the Uniform Building Code." Rev. Ord. 16-02
(November 2002)
9. One Side Yard shall not be obstructed to less than 36 inches. Notwithstanding that
certain accessory structures may be located in a Side Yard, such accessory structures
shall be located so that at least one Side Yard, which shall be gated, shall provide at
least a 36 inch width of direct and unobstructed passage to the Rear Yard.
10. Timing of Construction. Accessory structures, temporary structures, and swimming
pools shall be constructed or otherwise established at the same time as, or after, the
principal structure or use.
D. Requirements for Specific Accessory Structures that Apply City-wide.
1. Antennae. Antennae are subject to the provisions of Chapter 8.92, Wireless
Communications Facility Regulations.
2. Flag poles. Maximum height of 35 feet with a minimum 5 foot setback from any
property line. Additional height may be authorized through Conditional Use Permit
approval by the Zoning Administrator.
City of Dublin Zoning Ordinance 40-2 September, 1997
Amended January 20, 2004
ACCESSORY STRUCTURES AND USES REGULATIONS
Chapter 8.40
E. Agricultural Accessory Structures permitted by means of Site Development Review. All
agricultural accessory structures, including, but not limited to, stable, barns, pens, corrals,
greenhouses, or coops are permitted by means of a Site Development Review in the
Agricultural zoning district.
F. Permitted Residential Accessory Structures.
1. General requirements.
a. Enclosed Accessory Structures in Multi-Family districts. No enclosed
accessory structure shall be erected in aMulti-Family zoning district unless
pursuant to a Site Development Review.
b. In Front of a Residence. No accessory structure, with the exception of an
entry feature, shall be located in the Front Yard, the area between the Front
Yard and the residence, or within the portion of a Side Yard or a Street Side
Yard that projects in front of the residence.
c. Key lots. On a corner lot in an R-1 or R-2 zoning district adjacent to a Key
Lot no accessory structure shall be closer to the Street Side Lot Line than 10
feet.
d. Maximum square footage of detached accessory structures (excluding
swimming pools) on a lot. For lots less than 5,000 square feet in size, one
accessory structure in the Rear Yard with a maximum of 120 square feet shall
be exempt from the Coverage Requirements.
For lots 5,000 square feet in size or larger, the combined maximum square
footage of all accessory structures on a lot such as a detached accessory
garage, workshop, studio, or office shall not exceed 1,000 square feet unless a
larger size is approved by the Zoning Administrator by means of a Conditional
Use Permit. Rev Ord. 16-02 (November 2002)
e. Rear Yard Coverage. The maximum coverage of the required Rear Yard by
all accessory structures (with the exception of swimming pools) is 30%.
f. On the street side of a fence, hedge or wall. No accessory structure in an R-
1 or R-2 zoning district may be located on the street side of a fence, hedge or
wall.
City of Dublin Zoning Ordinance 40-3 September, 1997
Amended January 20, 2004
ACCESSORY STRUCTURES AND USES REGULATIONS
Chapter 8.40
2. Structures.
a. Exceptions to Accessory Structure Requirements. An exception to the
requirements of this section may be approved by the Zoning Administrator by
means of a Conditional Use Permit.
b. Decks. Uncovered decks under 30 inches in height are permitted anywhere on
a parcel, without respect to required setbacks.
c. Entry features. Entry features (such as arbors, arches, and trellises) may be
located within the required front Yard Setback provided they do not have a
width of more than 15 feet, and do not have a height more than 10 feet.
d. Greenhouse. A Greenhouse accessory structure with a maximum size of 500
square feet with transparent or translucent roof and/or wall panels.
e. Guesthouses. A detached Guesthouse accessory structure may be established
on the lot of asingle-family residence, as follows:
1. Not located in setback area. A guesthouse shall not be located within
any required setback area.
2. Permitted and prohibited spaces. A guesthouse may contain a
sleeping space, bathroom and other living space, but may not contain
kitchen facilities.
3. Floor area limitation. The maximum floor area allowed for a
guesthouse is 50% of the habitable floor area of the main residence, up
to a maximum of 840 square feet.
f. Recreation facilities. Including recreation activity courts and facilities,
swimming pools, spas and hot tubs, provided those facilities are to be used
solely by occupants of the dwelling(s) on the same lot and their guests.
g. Security gates. Security gates and gate houses at project entrances are
permitted through Site Development Review.
h. Heights and Setbacks. Heights and setbacks for detached shade structures,
gazebos, covered patios and enclosed structures are as follows:
Rev. Ord. 16-02 (November 2002)
For lots less than 5,000 square feet in size.
City of Dublin Zoning Ordinance 40-4 September, 1997
Amended January 20, 2004
ACCESSORY STRUCTURES AND USES REGULATIONS
Chapter 8.40
Shade Structures, Enclosed Enclosed Swimming
Gazebos, Structure greater Structure less pools, spas, hot
Covered Patios than 8 feet in than or equal to tubs and
and Unenclosed height 8 feet in height associated
Structures a ui ment
Hei ht max 10 feet 10 feet 8 feet 8 feet
Front Yard Not allowed Not allowed Not allowed Not allowed
Setback except for Entry
features
permitted by
Section
8.40.20. F.2. c
Side Yard 3 feet 3 feet 0 feet 0 feet
Setback
Street Side Yard 3 feet 3 feet 3 feet 0 feet
Setback
Rear Yard 3 feet 3 feet 0 feet 0 feet
Setback
For lots 5,000 square feet in size or larger: Rev Ord. 16-02 (November 2002)
Shade Structures Enclosed Enclosed Swimming
Gazebos Structure greater Structure less pools, spas, hot
Covered Patios than 8 feet in than or equal to tubs and
and unenclosed height 8 feet in height associated
structures a ui ment
Hei ht max 15 feet 15 feet 8 feet 8 feet
Front Yard Not allowed Not allowed Not allowed Not allowed
Setback except for entry
features
permitted by
Section
8.40.20.F.2.c
Side Yard 5 feet 5 feet 0 feet 3 feet*
Setback
Street Side Yard 5 feet 5 feet 5 feet 3 feet*
Setback
Rear Yard 5 feet 5 feet 0 feet 3 feet*
Setback
* Measured at waterline
i. Signs. Signs are regulated by Chapter 8.84, Sign Regulations.
City of Dublin Zoning Ordinance 40-5 September, 1997
Amended January 20, 2004
...
S
d
0
~ ~
~ ~
~ '~
~ o
~ ~t
~ ~
N ~'
W v'
O
d
O
C
^~
n
rf'~
ATTACHMENT 6
F
~ l~r
~ ~~~
~~ _.._
~y ~ 7 si
i/
~~v,
,, .
•<.,~:.,
'
~
~
~
` r
t ~` ~,~.~;
`,~
.;