HomeMy WebLinkAboutReso 031-86 PD Rez R&N AlamoCr RESOLUTION NO. 31-86
A RESOLUTION OF THE CITY COUNCIL
OF THE CITY OF DUBLIN
APPROVING AND ESTABLISHING FINDINGS
AND GENERALPROVISIONS FOR A PLANNED DEVELOPMENT (PD) REZONING
CONCERNING PA 85-041.1 VILLAGES AT ALAMO CREEK -
RAFANELLI AND NAHAS REAL ESTATE DEVELOPMENT
WHEREAS, Rafanelli and Nahas Real Estate Development is requesting
the City rezone approximately 135 acres lying in the northeast corner of the
City, to a Planned Development (PD) District for a planned residential/
commercial development of 1,165 dwelling units (including 1,019 multiple
family residential units and 146 lots for future development of single family
residential detached units), a five-plus acre neighborhood park site, a 9,000_+
square foot commercial site for future development as a convenience store, and
common open space parcels; and
WHEREAS, the Planning Commission did review the project at a
series of public hearings beginning with a noticed public hearing on February
18, 1986, and concluding with a public hearing on March 17, 1986, at which
time the Planning Commission adopted Resolution No. 86-014 recommending
approval of the Planned Development (PD) Rezoning request, PA 85-041.1; and
WHEREAS, proper notice of this request was given in all respects
as required by law for the Planning Commission hearings and the March 24,
1986, City Council public hearing; and
WHEREAS, the Staff Report was submitted recommending that the
application be approved subject to conditions prepared by Staff and reflected
in Planning Commission Resolution No. 86-014; and
WHEREAS, the City Council did hear and consider all said reports,
recommendations and testimony as herein set forth; and
WHEREAS, the City Council reversed with the Planning Commission's
recommendations regarding the proposed residential product type and density of
Village VII, determining that retention of the proposed Multiple Family
Residential, 12.75~ dwelling units per Gross Residential Acre Development
Standard for Village VII, when considered in conjunction with the proposed
146-1ot Single Family Residential development proposed in Village VI, was not
in conflict with the City's General Plan Policy Guidelines that call for the
avoidance of economic segregation by City sector, and specifically call for
some of the units approved in the subject property to be single family
residential-detached units; and
WHEREAS, pursuant to State and City environmental regulations, a
Mitigated Negative Declaration of Environmental Significance has been
previously adopted for the Rezoning and Tentative Map requests (City Council
Resolution No. 30-86); and
WHEREAS, the City Council finds that the proposed rezoning, as
modified, is consistent with the City General Plan and Policies; and
WHEREAS, the City Council finds that the proposed rezoning will
not have a significant environmental impact; and
WHEREAS, the rezoning, as modified, is appropriate for the subject
property in terms of being compatible to existing land uses in the area, and
will not overburden public services; and
WHEREAS, the rezoning will not have substantial adverse effects on
health or safety, or be substantially detrimental to the public welfare, or be
injurious to property or public improvements; and
WHEREAS, there is little or no probability that the rezoning, as
modified, will be a detriment to, or interfere with, the City's General Plan;
NOW, THEREFORE, BE IT RESOLVED THAT THE City Council hereby
approves the Planned Development (PD) Rezoning request PA 85-041.1 subject to
the following Conditions of Approval.
CONDITIONS OF APPROVAL PA 85-041.1
GENERAL PROVISIONS
e
This approval is for a mixed use planned residential-commercial
development of single family and multiple family dwelling units and as a
small convenience store. Development shall be generally consistent with
the following submittals, modified to conform with Conditions of
Approval outlined below. Unit Counts in the respectiVe Villages may
vary from the numbers initially proposed by a maximum of 5%, as long as
the unit total does not exceed the aggregate total indicated by the
referenced plan submittals.
Revised Illustrative Development Plan - CompoSite Plan - Proposed
by Anthony M. Guzzardo and Associates, Inc., dated received
February 3, 1986.
Be
The Villages at Alamo Creek Tentative Map - Prepared by Tetrad
Engineering, Inc., dated received July 31,1985.
The Villages at Alamo Creek - Villages 1-5 - Preliminary Floor
Plans and Building Elevations, consisting of 12 sheets, prepared
by Backen, Arrigoni and Ross, Inc., dated received July 31, 1985.
Alamo Creek: Village VI - Dublin, CA - Preliminary Site Plan and
Building Elevations, consisting of four sheets, prepared by Aram,
Bassenian and Associates, Inc., dated received January 27, 1986.
ge
The Villages at Alamo Creek - Landscape Plan - Typical Unit
Cluster and Recreation Center, Schematic Park Plans and Site
Sections - Consisting of five sheets, prepared by Anthony M.
Guzzardo and Associates, Inc., dated June 14, 1985.
Proposed Alamo Creek Improvements, Amador Valley Boulevard to
Contra Costa County Line - Consisting of six sheets, prepared by
Bissell and Karn, Inc., dated received May 23, 1985.
Alamo Creek - Village I Convenience Store Study Schematic Site
Plan and Building Elevations, Dublin CA - Prepared by Backen,
Arrigani and Ross, Inc., dated received August 2, 1985, as
modified by the submittal entitled, The Villages at Alamo Creek -
Village I - Revised Site Plan dated received February 25, 1986.
Village VII - Flood Control Maintenance Road Emergency Fire AcceSs
- Consisting of a single sheet, prepared by Anthony M. Guzzardo
and Associates, Inc., dated received December 11, 1985,
Cross Sections at Alamo Creek - Consisting of a single sheet,
dated received February 6, 1986.
Je
Preliminary Parking Assignment Plan - Village I - ConSisting of a
single sheet, dated received December 11, 1985.
Site Development Review approval for each phase of this project shall be
secured prior to the recordation of the respective Final Maps or the
issuance of building permits.
Except as may be specifically provided for within these conditions of
approval, the development shall comply with City of Dublin Site
Development Review Standard Conditions (see Attachment A).
Except as may be specifically provided for within these Conditions of
Approval, development shall comply with City of Dublin Police Services
Standard Residential Building Security Requirements (see Attachment B).
Be
6e
Approval of this Planned Development is for two years as is specified in
Section 8-31.2(b) of the Zoning Ordinance, or as detailed on an approved
project phasing schedule. The phasing plan outlined in the applicant's
letter dated February 27, 1986, is acceptable in terms of the timeline
cited for commencement of construction of the respective residential
Villages. The formal project phasing schedule shall elaborate on this
letter and detail timing of construction of all major project
improvements.
If the subject project is not subdivided, as proposed under Subdivision
5511, the project shall remain subject to the Conditions of Approval
established for that Subdivision, as determined applicable by the City
Engineer and the Planning Director.
AIR QUALITY
7. Roadway Improvements
The site Plan shall be altered to make provision of bus turnouts for
future transit Plans servicing Dougherty Road and Amador Valley
Boulevard. Such turnouts shall be located along the internal loop roads
in Villages II, III, IV, and V, or as required by the City Engineer and
the local transit authority.
8. Particulate Control
Ae
Significant landscaping shall be provided along project streets,
including Dougherty Road frontage and Amador Valley Road, to
partially filter particulate matter emanating from those roads.
Be
Dust control measures, as approved by the City Engineer, in
conjunction with the project's improvement plans, shall be
followed at all times during grading and construction operations.
Construction areas shall be sprinkled during periods when work is
proceeding and during other periods, as required, to minimize the
generation of dust.
Ce
Construction areas shall be revegetated and hydromulched upon
completion of grading operations? Where feasible, hydromulch
shall be installed in stages.
De
To the extent feasible, phased project construction shall balance
cut and fill to avoid off-hauling, or importation of material
along roadways.
BIOLOGICAL RESOURCES
9. Loss of Major Trees
Trees identified in the Horticultural Report, prepared by Hort
Science, Inc., September 20, 1985, and the tree preservation
identification list (Appendix A of these Conditions) shall be
preserved and protected. The project shall implement the Tree
Preservation Design, Construction, and Maintenance Guidelines
contained in the Horticultural Report~ Within the creek channel,
the applicant shall have the responsibility for implementing these
guidelines for a minimum period of one year from the completion of
construction, or until the Alameda County Flood Control District
or other public entity accepts the channel, whichever is later.
Be
A hOrticulturalist shall develop a specific preservation plan for
preservation of trees identified as "preserved" and "high
probability to preserve" following development of final grading
plans. During site preparation and construction, a
horticulturalist shall monitor and implement the specific
preservation plan, and shall supervise construction activities,
especially grading and pruning, as needed to implement the plan.
10.
De
ge
Fe
Ge
He
ge
Me
A revegetation plan for the creek shall be prepared and
implemented which includes the replanting of native species. The
revegetation plan shall include provisions to aid new trees during
early years through irrigation, fertilization, deer protection and
disease prevention.
New trees and shrubs shall be planted on both sides of the creek
as well as on new embankments to be constructed along the creek.
Trees shall be located above the maintenance road per Alameda
County Flood Control District Zone 7 specifications.
Two new trees of at least 15 gallon size shall be provided within
the creek tree planting plan area to mitigate the loss of each
existing tree over 8 inches in diameter. To the extent feasible,
new trees shall be of the same species as the trees lost. Ail
plans for additional tree planting shall be subject to review and
approval by Alameda County Flood Control District Zone 7.
Whenever possible, construction activities shall be restricted
from within the drip line. At the maximum, no more than 40
percent of the area within the drip line for trees planted to be
preserved shall be altered.
During project construction, damaged roots shall be cut cleanly
with a saw. Trenches shall be back-filled as soon as possible to
avoid exposure of roots from dessication. Irrigation during and
following construction shall be provided where necessary.
Supplemental irrigation for trees subject to stress shall be
provided.
Positive drainage away from tree trunks shall be established and
water shall not be allowed to stand at the base of the trees.
Open areas around trees to be preserved shall not be grubbed where
grading activities are not required.
Organic mulch shall be applied and maintained under the trees
within the development areas.
Horticultural care, monitoring of pest population and the
incidence of disease and control treatments when necessary, shall
be provided. This measure shall apply to all trees with health
classified by the Horticultural Report as A, B, or C and as
identified by the tree preservation identification list (Appendix
A of these Conditions) as "preserved" or as having a high or
medium probability of being preserved.
Temporary fences shall be constructed around the trees to be
preserved to exclude all equipment from within the drip line.
Ail wounds to trees to be preserved shall be repaired promptly,
with such repair and pruning to be performed by a qualified
arborist.
Riparian Habitat Loss
Ae
Temporary fencing shall be provided during the construction for
those areas of riparian habitat not intended to be included within
the construction zone.
Be
An erosion and siltation control plan shall be incorporated within
the grading plan for the project.
Ce
A revegetation effort shall be implemented on all reconstructed
channel banks as soon as possible after construction is completed
to enhance riparian habitat consistent with proper channel
maintenance for flood control. Such revegetation plans shall
include the following:
-4-
11.
12.
1)
2)
Use of trees, shrubs and vine species native to the region.
Use of shrubs with high wildlife value on the lower channel
slopes.
B)
Use of indigenous tree species, such as valley oak, live oak
and buckeye, on the upper channel slopes above the
maintenance road, together with shrubs and vines to
approximate a natural riparian community°
4)
Planting of trees on the upslope side of the channel
maintenance road.
5)
Trees, shrubs and vines may be established from seeds, liner
stock or small container stock (one gallon) or hydromulch
where feasible.
6)
Undertaking of an irrigation program to aid survival of
woody plants during the first few summers. Where feasible,
fixed irrigation shall be installed.
7)
S)
Inclusion within the revegetation'plan of portions of the
existing riparian corridor which are intended to be left in
their present condition, including provisions for native
trees, shrubs and vines, where they do not now exist.
Obtaining the approval of Alameda CoUnty Flood Control
District for the revegetation plan, which shall be
consistent with Flood Control maintenance requirements.
9)
Provision of revegetation along the riparian corridor and
the successful establishment of plantings, Subsequent
maintenance and management of vegetation in the stream
channel will be the applicant's responsibility for one year
following completion of construction.
Drop structures shall not exceed a maximum height of two feet and
shall be constructed in a manner the Department of Fish and Game
approves.
Construction Phase Impacts
Ae
Earth moving shall be undertaken and carried out during the dry
season,
Prior to winter rains, all bare ground shall be hydroseeded. If
grading is undertaken during winter time conditions, a plan shall
be submitted for stabilization and control of erosion. Such plan
may include mechanical soil stabilization, sediment barriers, and
settling ponds.
Ce
Conditions of the California Department of Fish and Game Stream
Alteration Permit shall be followed to minimize erosion during
construction in the creek channel.
Sediment control measures shall be used within construction areas
to reduce movement of silt and other sediment from the site.
In order to protect both the riparian corridor and isolated trees
from construction equipment, vehicular activity, and dumping of
trash and debris, areas not intended to be graded shall be
protected with temporary fencing.
Long Term Impacts
Human use of the riparian corridor and stream channel shall be
restricted and, where feasible, fencing erected for this purpose.
-5-
ENERGY
13.
Ail units shall contain standard and currently available energy saving
devices, and shall be insulated in accordance with Title 24, State of
California Administrative Code. Ail buildings shall be designed to
comply with Title 24 Energy Regulations.
14.
Ail multi-family units shall be provided with separately metered gas for
hot water. All meters shall be screened from view within an enclosure
that is compatible in design, location and materials to that of the
building to which it is to be installed,
15.
Exterior lighting fixtures in multi-family areas shall be energy
efficient, fluorescent or metal vapor lighting.
16.
Landscape design shall incorporate use of solar shading for south- and
west-facing walls in multi-family housing areas.
17.
Recreation area pools in the multi-family project shall incorporate
solar heaters. The developer shall submit documentation that the
number, size, location and design at the solar collector panels will
suffice to provide adequate pool heating for a reasonable length of time
in each calendar year. Heating of the pools may be supplemented by gas
heaters.
HYDROLOGY AND WATER QUALITY
18. Increased Flows
The capacity of the Alamo Creek channel shall be increased
sufficiently to meet the future flows both of this project and
future buildout of the Alamo Creek drainage (as established by the
Hydraulic Analysis of Alamo Creek, Alameda and Contra Costa
County, prepared by Bissel and Karn, Inc., 1984).
Drop structures shall be installed as needed to reduce the
velocity in Alamo Creek to the 5-7 f.p.s, range and to reduce
erosion caused by the existing creek. The drop structures shall
conform to the Department of Fish and Game requirements, as
follows: Drop structures shall be of a height no greater than two
feet, and the area .immediately downstream of the drop structure
shall be left in a natural state. If a ponded or pooled area of a
minimum dimension of two feet deep and six feet out from the drop
structures is formed which allows fish to congregate and migrate
upstream at peak flows, then a concrete base below the new drop
structures may be used. If concrete is not used, then a two foot
headwall deeper than the drop structures shall be installed to
prevent undercutting.
Alamo Creek shall be realigned to reduce erosion and severe bends
within the channel and to stabilize the existing unstable slides.
De
The applicant shall be responsible for the project's proportionate
share of the cost of flood control improvements, which are
anticipated to be specifically two box culverts, of a size
sufficient to accommodate lO0-year flood flows, to be installed in
the Alamo Creek channel under Amador Valley Boulevard. The
project's share of the improvement cost will be calculated based
on the project's overall contribution to the incremental increase
in the lO0-year flood flows to that of the projected upstream
increased from future development.
ge
Six-foot black clad chain link fencing shall be installed by the
applicant along both sides of the creek. For that portion of the
creek within the proposed neighborhood park, the applicant shall
be responsible either to construct the fence along the creek
right-of-way, or to contribute an amount in cash equal to the
applicant's cost to provide materials and installation, if an
alternate design or location-for said fencing isiestablished by~
khe City.
19.
Increased Erosion and Sedimentation
Ao
Grading within Alamo Creek shall be limited to the period from
April 15 through October 1 of each year.
Be
An erosion control plan shall be prepared by the developer's
Engineer and submitted with the grading plan. The plan shall be
in use until permanent storm sewers have been installed and
streets paved, and then these erosion control plans shall be
modified to the new Conditions.. Erosion control plans shall
include, as required, hydromulching cut-and-fill slopes, sediment
barriers, and sedimentation basis and ponds. Grading shall be
condUcted in such a manner that standing water is not retained in
the vicinity of trees to be preserved.
Ce
A permanent revegetation plan shall be. prepared for revegetation
of the channel, consistent with the requirements of Alameda County
Flood Control District Zone 7.
De
Culverts discharging into the stream channel shall be constructed
in such a manner as to avoid erosion by providing impervious
spillways on the side slopes into the bottom of the channel
Final improvement plans prepared for the channel shall maintain
the maximum amount of existing channel vegetation feasible and
shall, preserve existing tree stands identified in the
Horticultural Report, The Villages of Alamo Creek, September 20,
1985, prepared by Hort Science, Inc., and subsequent tree
preservation and protection analysis contained in Appendix A of
these Conditions.
MUNICIPAL SERVICES AND FACILITIES
20.
Water Supply
A. The project shall extend water service from its current location
at Stagecoach Road and Amador Valley Boulevard to the project.
Be
The project shall incorporate all reasonable water conservation
measures including water conservation applicances and separate
metering of gas for hot water heaters,. The project Architect, or
Civil Engineer, shall provide a letter to the Planning Director or
Building Inspector stating the water conservant toilets, shower
heads, and automatic dishwashers with low flow cycles will be
installed in the units in this project.
21. Fire Protection
me
Ail dwelling units within the project shall incorporate smoke
detectors and spark arrestors on fireplaces.
Ongoing provision of fire breaks shall be included in the plans
for maintenance of the open space abutting Villages VI and VII.
Ce
Emergency access routes to Villages VI and VII and to the west
side of the creek shall be provided from Amador Valley Boulevard
via the maintenance road along the west side of Alamo Creek.
Emergency access to the site at the north end of Village VI shall
be provided at the time of development of the adjacent project to
the north in Contra Costa County. Emergency access routes are
subject to the approval of the District's fire protection service.
De
Fire hyrdants at the locations approved by the DSRSD-Fire
Department shall be installed and operable, to the satisfaction of
the DSRSD-Fire Department, prior to combustible construction.
Provision of raised blue reflectorized pavement markers shall be
made in the center of the private vehicle accessways at each fire
hydrant.
-7-
22.
23.
NOISE
24.
ge
Each building and residence unit shall include a lighted, clearly
visible address. A lighted, clearly visible project directory
shall be provided at all major project access ways within the
multi-family Villages.
Police Protection
Be
Emergency access along the Alamo Creek channel maintenance road to
the lands lying west of the creek shall be developed.
Fencing of a design and location acceptable to.the Dublin Police
Services shall be provided along the Alamo Creek corridor.
Provision for a future emergency connection at the north end of
Village VI to the adjacent project on the north side of the County
line in Contra Costa County shall be made through modification of
the lot layout in Village VI and the recordation and pursuit of
appropriate complimentary easements between the affected
properties.
Recreation
Parkland shall be dedicated or in-lieu fees shall be paid., or a
combination of both shall be provided prior to issuance of Building
Permits or prior to recordation of the Final Map, whichever occurs
first, in accordance with the Subdivision Ordinance. The parkland
dedication required is approximately 10,485 acres (0~009 acres/dwelling
units x number of dwelling units). The subdivider/developer shall
receive 5.0 acres of credit for the parkland dedication. The
subdivider/developer shall provide certain improvements to the dedicated
parkland. The dedicated parkland and associated improvements shall
satisfy the developer's total park dedication requirement. The
improvements shall be installed to the City's satisfaction within 30
months of the recordation of the Final Map or issuance of Building
Permits. The items to be provided shall be as specified in the
Compromise Park Proposal portion of the Memorandum from the City Manager
to the City Council regarding Villages Development Park Dedication
Proposal dated March 20, 1986, as revised and adopted by the City
Council.
Camp Parks
Ae
Noise measurements at the Alamo Creek Villages site determined
that relatively simple plywood noise barriers constructed behind
the shooting ranges would effectively reduce noise reaching the
Alamo Creek Villages site. If, after people move into the subject
residential projects, complaints from residents are received by
the City of Dublin and/or the United States Army, all reasonable
steps by the developer shall be undertaken to assure this
mitigation measure is implemented. This mitigation measure is
consistent with mitigation measures in the preliminary draft
revised EIS which states: "on-site and off-site monitoring will be
conducted to define the extent and magnitude of noise levels
generated by.Parks RFTA activities" and that "the U.S. Army will
continue to coordinate with City and County officials regarding
land use compatibility in the areas planned for residential
development."
Be
Prospective purchasers or residents of the proposed project shall
be supplied with a written document indicating that sound levels
of up to 70 dBA may be generated by gunshots at the regional
training facility, and explaining when these activities are
generally expected to occur.
Ce
The developer shall construct a minimum 8-foot high berm on the
east side of Dougherty Road (subject to approval by the Army) from
Amador Valley Road north, a point approximately halfway to the
-8-
25.
County Line where this berm will terminate into a natural hill.
This earthen berm shall have side slopes flat enough to mow with a
riding mower. This berm shall also be hydroseeded with wild
flowers and native, low growing plant materials (subject to Army
approval). It is understood that this berm is to be constructed
from strippings and other excess material from the grading of the
subject property.
Traffic
Ae
An 8-foot-high sound barrier wall along the project frontage with
Dougherty Road shall be developed in conjunction with this
project.
Be
Landscaping along Dougherty Road and Amador Valley Boulevard shall
be of a type and planting layout to provide a mature growth
pattern which w~ll grow to create a barrier in excess of eight
feet high.
Ce
Sound-rated windows (Sound Transmission Class 27) shall be
provided for all multi-family dwelling units to reduce traffic
noise impacts and to meet Title 24 multi-family housing
requirements.
De
Prior to issuance of building permits, the developer shall submit
the appropriate documentation to demonstrate that all proposed
development shall meet or exceed applicable State noise
attenuation requirements.
SITE DEVELOPMENT REVIEW SUBMITTAL
26. Open Space
Common open space areas for the multiple family residential
villages shall be increased to meet a minimum standard of 35
percent for each respective village. Density shall be reduced if
necessary in order to increase useable open space within the
villages to meet this standard.
Be
Deck dimensions for multiple family units on second or third floor
elevations shall be increased a mim~num requirement of seven feet,
excluding fencing or railing.
Ce
Private useable open space (patios) for multiple family
residential ground level units shall be a minimum of 140 square
feet in area.
De
Through the Site Development Review process, the developer shall
investigate the feasibility of leaving portions of the creek
accessible as useable open space in conjunction with a joint use
program between the City and Zone 7.
The recreational facility requirements for Villages VI and VII
shall be detailed in the Site Development Review submittal for
that Village and shall be addressed with the overall project
parkland dedication agreement.
Pool length shall be increased to 50 feet minimum length in at
least two of the six proposed recreation areas.
The initial Site Development Review shall include submittal of a
proposed master trail system which provides for a connection of
the pedestrian system and the community park with the regional
open space in Dougherty Hills. A linkage of the bikeway to the
west part of the park and Villages VI and VII shall also be
provided for by this plan.
-9-
27.
28.
29.
30.
31.
32.
He
The Site Development Review submittals for the multiple family
residential Villages shall define pedestrian ways from assigned
parking spaces to respective individual multiple family dwelling
units, and from dwelling units to recreation centers.
Fences on the upper tier of lots (westerly perimeter) in the
single family residential area shall be established at the lower
toe of the slope, unless otherwise approved through the Site
Development Review process for Village VI.
Landscape Design
The Site Development Review submittals shall detail a separator
landscape strip between the bikeway and the access road along the creek.
Architectural Design
Site Development Review submittals shall include plans at an appropriate
design scale which detail that:
Ae
Ail dwelling units are oriented properly and at a sufficient
distance from each other, from parking and vehicular areas, and
group use areas.
Parking and vehicular areas shall be screened with patio fences or
appropriate landscaping from view of ground floor dwelling units.
Ce
To the extent feasible, west-facing units have sun-shading devices
or landscape screening to prevent over-heating of units.
Architectural design is compatible in color and finish with its
surroundings.
ge
Roofing materials shall be premium-weight asphalt shingles (275-
300 pounds per square), in order to produce additional texture and
shadow pattern.
The developer shall confer with local postal authorities to determine
the type of centralized mail receptacles necessary and provide a letter
stating their satisfaction at the time the Site Development Review
submittal is made. Specific locations for such units shall be to the
satisfaction of the Postal Service and the Dublin Planning Department.
If centralized mail units are not required, the developer shall provide
written documenta'tion from the Postmaster stating the exemption.
At-grade patios for the multiple family residential units shall be
individually fenced and shall be supplied with soil preparation to
accommodate future planting. Individual hose-bibs for each ground level
unit patio area shall be provided by the developer. The hose-bibs may
be maintained left in a "roughed-out" stage until such time as the units
are put up for individual sale~ The layout of the enclosed patio areas
(as regards size and placement of concrete patio pads and the design of
the enclosing fencing and retaining walls) shall be subject to review
and approval as part of the respective Site Develpment Review submittal.
The developer's Engineer shall develop the expected truck length and
turning radius criteria to use the private streets (fire equipment,
delivery, garbage or moving trucks, etc.) and design the curb radii
accordingly and submit this data and design criteria with the Site
Development Review application.
Wheel stops within the project shall be at the curb at the end of the
parking stalls. Parking stalls shall be a minimum depth of seventeen
feet for standard-sized stalls and fifteen feet for compact-sized stalls
(assuming two-foot overhang for both types of spaces).
-10-
33.
34.
35.
36.
37.
38.
39.
40.
41.
42.
Special private storage areas of at least 120 cu. ft. per multiple
family residential unit shall be provided within or adjacent to each
unit. Details of the location and design of these areas shall be
subject to review and approval as part of Site Development Review
submittals.
Information detailing the design, location and materials of all fencing,
and of retaining walls over two feet in height, shall be subject to
review and approval as part of the Site Development Review submittals,
Slopes for areas adjoining both public and private roadways shall be
designed to maximize the level areas available for landscape treatment
and for general safety consideration and shall be subject to review and
approval through the Site Development Review process.
Light standards (freestanding, pedestrian and/or wall mounted) utilized
in this project shall be of a design which shields the light sources
from view from off-site while providing for adequate security and safety
illumination. Light standards shall be subject to review and approval
as part of the Site Development Review submittal as regards design,
location, number and illumination intensity.
Handicapped ramps and access as required by Title 24, State of
California, shall be provided (parking and walkways serving on-site
recreational facilities). Handicapped parking stalls, appropriately
signed, shall be provided evenly throughout the project with their
location and design as part of the Site Development Review submittal.
The use of entrance gates at any portion of this development are
specifically disallowed unless architectural treatment, traffic and
emergency access impacts are addressed and approved through the Site
Development Review process.
A pedestrian circulation plan shall be submitted as part of the Site
Development Review materials. The plan shall include section details of
the pathway system and a detailed pedestrian walkway lighting plan.
To facilitate the development of an interconnection between the proposed
creekside pedestrian pathway system and the 90± acre open space area to
the west, the cul-de-sac bulb at the terminus of the roadway separating
Villages VI and VII shall be moved down sloPe 50-75 feet to function as
a "knuckle" and to allow for an easier slope transition for pedestrian
trail access up the slope to the adjoining 90± acre open space area.
Pedestrian access through this area will necessarily traverse the seven
+ acre remnant open space area that will lie above the day-light zone of
the proposed grading for the single family residential development in
Village VI. A schematic grading plan for the route of the pathway
system connection from the realigned "knuckle" to the adjoining 90-acre
open space area shall be sUbmitted as part of the Site Development
Review submittals for either Village VI or VII, whichever is the first
to be submitted to the City for processing.
Signs established at entrances to the respective Villages for project
identification purposes shall be subject to review and approval as part
of the Site Development Review submittal as regards location, copy and
design.
The potential design changes called for in Village I (concerning the
pursuit of a secondary access point, the adjustment to internal
circulation patterns and parking counts, and the impacts to the area
resulting from an enlargement and reconfiguration of the adjoining
commercial area) shall be reviewed through the Site Development Review
application for that Village. The applicant shall pursue a second
vehicular connection to serve the units in Village I to improve internal
circulation and to allow a diminishment of the distance between the more
remote unitsand their respective assigned parking.. The developer shall
diligently pursue the necessary approvals to develop access from the
south of Village I, through the existing Arroyo Vista Housing Authority
project. Failure to secure this preferred secondary access shall not
-11-
release the applicant from pursuing provision of a secondary access to
Village I. In lieu of this access from the south, the applicant shall
investigate the feasibility of providing a second access along the
Amador Valley Boulevard frontage. Revisions to the site plan layout for
Village I shall be made to reduce the distances between available
parking and the more remote dwelling units. The amount of parking
provided shall be adjusted to match the standard being observed
elsewhere across the project (129-space suggested standard for 60-units)
or a more restrictive standard to acknowledge that development of 3-
bedroom units may result in a greater need for parking than the other
multiple family residential villages.
SOILS, GEOLOGY AND SEISMICITY
43. Seismic Activity
Recommendations contained in the Geotechnical Investigation Report,
Alamo Creek, April 11, 1985, prepared by J. H. Kleinfelder & Associates,
shall be implemented.
44. Soils and Slope Stability
Ail foundation design, grading operations and site construction
work shall be consistent with the recommendations of the
Geotechnical Investigation Report, prepared by J.H. Kleinfelder &
Associates, dated April 11, 1985, and of the August 5, 1985,
letter from J.H. Kleinfelder & Associates to Ronald Nahas
regarding response to review comments on the Alamo Creek project.
Be
No cuts or fill slopes shall exceed a slope of 2:1. Where
possible, cuts or fills should be designed at 2.5:1 or flatter.
Ail fills of sufficient height shall be keyed into the existing
soils as recommended by the soils report prepared for this site.
Ail cut slopes of sufficient height should have bench gutters to
prevent drainage over the face of the slopes.
Prior to any grading of the site, a detailed plan covering grading
(including phasing), drainage, water quality, erosion and sedimen-
tation control for construction and the post-construction period
shall be prepared by the project Civil Engineer and/or Engineering
Geologist, and shall be approved by the City Engineer. Said plans
shall include detailed design, location, and maintenance criteria
of all erosion and sediment control measures. The plans shall
attempt to assure that no increase in sediment or pollutants from
the site will occur. The plan shall provide for long-term
maintenance of all permanent erosion and sediment control
measures.
Alamo Creek shall be realigned to prevent further undercutting of
existing slides on the east side of the Dougherty Hills. Slope
protection shall be provided within the creek where necessary to
improve slope and bank stability.
Ge
Emergency access shall be provided to Villages VI and VII along
the west side of Alamo Creek along the proposed maintenance road
to serve as an emergency route in the event of damage to the
principle entrance across the creek due to seismic activity or
other natural disaster.
A report addressing the liquefaction danger to buildings adjacent
to Alamo Creek shall be prepared.
Ail structures shall be set back a minimum of 15 feet from the top
and toe of the slopes, pursuant to recommendations in the
Geotechnical Investigation Report, Alamo Creek, dated April 11,
1985 (J.H. Kleinfelder & Associates).
-12-
45.
Je
Sub-drains shall be installed in all existing natural drainages
which are to receive material. Installation shall be per the
requirements of the Soils Engineers,
Catch-basins shall be installed during the primary grading
operation where waters are concentrated in the proposed single
family lot areas.
ge
Revegetation with hydromulch with native vegetation shall occur
after each grading season. On Dougherty Hills grading areas,
revegetation shall simulate original conditions to the greatest
extent feasible.
Me
Full-time soils inspection by the Soils Engineer representative
during mass grading operations shall be provided by the developer.
Ne
De
Ail lots shall be graded to slope toward the streets to avoid rear
yard drainage channels and protect slopes from erosion.
The design of all multi-family residences shall be reviewed by a
licensed structural engineer for seismic requirements prior t° the
issuance of building permits.
Pe
Where import depth of non-expansive soils is less than 2.5 feet
thick, post tension slabs should be used to avoid potential damage
from expansive soils.
We
Ail import soil brought onto the site shall be of a non-expansive
nature.
Re
Where soil or geotechnical conditions encountered in grading
operations are different from that anticipated in the soil and
geological investigation reports, or where such conditions warrant
changes to the recommendations contained in a site-specific/
project-specific soils and geotechnical report which shall be
submitted for review and approval by the City and shall be
accompanied by an engineering and geological opinion as to the
safety of the site from hazards of erosion, settlement and seismic
activity.
Mass Grading
A. Cuts and fills shall be designed to balance whenever possible to
avoid the need of offsite hauling~
Be
Cut-and-fill slopes shall be contour-rounded to conform as closely
as possible with the natural slopes, to avoid a man-made
appearance, and to form a gradual transition to natural terrain.
Variable sloPes shall be used to mitigate environmental and visual
impacts of grading.
TRAFFIC AND CIRCULATION'PROJECT'RELATED IMPACTS
46. Dougherty Road/Amador Valley Boulevard Intersection
The developer shall widen Dougherty Road both north and south of
Amador Valley Boulevard with a minimum of 24 feet of asphalt
paving to provide four lanes south of Amador Valley Boulevard and
50 feet of asphalt paving width north of Amador Valley Boulevard~
Widening will take place from the existing four lanes on the south
side of the S.P.R.R. right-of-way to the northern project
boundary. Dougherty Road north of Amador Valley Boulevard may be
widened to four lanes in phases to correspond with the connection
of project access roads to Dougherty Road, or may be constructed
along the total frontage along with the first unit developed.
(Subject to City Engineer review and approval, alternative
improvements may be acceptable.) DoUgherty Road widening shall be
-13-
47.
48.
49.
completed from Amador Valley Boulevard to the northerly line of
Village III prior to occupancy of Village II or III. Those street
improvements on Amador Valley Boulevard shall be complete prior to
occupancy of the first Village developed.
Be
The developer shall construct a free right-hand turn interim lane
on Dougherty at Amador Valley Boulevard. Upon construction of the
ultimate right-of-way of six lanes and a divided median on
Dougherty Road, this right hand lane shall be modified to function
as a joint right-hand turn lane and through southbound travel
lane.
The developer shall install a signal at Amador Valley Boulevard
and Dougherty Road. The signal is to be installed and operational
prior to occupancy of more than 300 units.
De
The developer shall increase the number of parking spaces by 32
spaces to meet minimum requirements for dwelling units and to
provide 15 percent guest parking. Parking spaces shall be
designed to meetminimum dimensional requirements. The ratio of
compact spaces to full size spaces shall not exceed 50 percent of
the uncoVered parking,
Dougherty Road/Dublin Boulevard Intersection
The project developer shall pay for construction of a right-hand turn
lane, including curb, gutter and signal improvements, together with
restriping as necessary, to accommodate a free right-hand turn lane off
Dougherty Road and Dublin Boulevard. Improvements shall be complete or,
in the event that right-of-way acquisition has not been completed by the
City, funds shall be deposited with the City to cover the required
improvements prior to occupancy of more than 360 project units.
Village Parkway/Amador Valley Boulevard Intersection
The developer shall reconstruct and improve Amador Valley Boulevard by
narrowing the portion of the median fronting the property line to
Dougherty Road, providing lighting and landscaping, repairing and
overlaying the existing street section, providing four lanes from the
entrance of Villages I and II to Dougherty Road,,and providing a
separated eight-foot width off street bicycle system from Dougherty Road
to the west side of the entrance to Villages I and II. From that point,
the bicycle and pedestrian systems shall be separate, as detailed in PD
Condition #65-C.
Emergency Access Routes to Villages VI and VII
The developer shall provide an emergency access route to Villages VI and
VII. The proposed maintenance road on the west side of the creek may
serve as the emergency access road, providing that design and
engineering studies prove this access feasible. Emergency access roads
must be 20 feet minimum width, and may not be routed through the
community park.
50.
51.
The lotting layout of Village VI shall be modified to allow the right-
of-way that is to be offered for dedication at the north end of the
cul-de-sac adjoining proposed Lots #113 and #114 to include all lands up
to the County Line. This adjustment shall be made to reserve for the
City of Dublin the flexibility to pursue a future emergency access
linkage with the land to the north upon the submittal to the City of San
Ramon of a development plan for the property.
The right-of-way along the north side of the northernmost proposed
public loop road for Village V shall be widened to include all lands up
to the County line, This adjustment shall be made to reserve for the
City of Dublin the flexibility to consider possible road connections
serving future development to the north, in the City of San Ramon, which
-14-
may subsequently be determined desirable to minimize the number of
intersections along Dougherty Road and/or to mitigate possible alignment
conflicts of intersections proposed to be located along Dougherty Road.
TRAFFIC AND CIRCULATION - CUMULATIVE IMPACTS
52.
The developer shall increase the size of Dougherty Road from the
existing two lane configuration north of Amador Valley Boulevard wh%ch
would accommodate project traffic to a completely new, full four-lane
configuration with a 3-foot painted median (or alternate improvements as
approved by the City Engineer). Street lights shall be placed along the
west side of the road,
53.
54.
The developer shall construct an additional two lanes along Dougherty
Road where the existing curb and gutter have been installed for the
Arroyo Vista development across the Southern Pacific Railroad tracks.
This section of road shall be complete prior to occupancy of 650 units.
The developer shall widen Amador Valley Boulevard to four lanes from the
entrance from Villages I and II to Dougherty Road~ This project shall
be completed prior to occupancy of any of the units in the development.
In addition, the median fronting this project shall be landscaped and
double headed street lights shall be placed in this median.
55.
The applicant will install conduit for future signals at the main
project entrances to Villages IV through VII and at the Amador Valley
Boulevard entrance to Villages I and II for possible future traffic
signals.
56.
The developer shall provide for the development of complete plans for
the final improvement of Dougherty Road for the entire project frontage
to its ultimate design configuration.
57.
The developer shall modify the site plan layout to provide bus turnouts
along the internal street system, Dougherty Road, and Amador Valley
Boulevard, the locations and design of which shall be subject to review
'and approval by the City Engineer and the local transit authority.
58.
The following changes in the circulation system shall be made in Village
VI: 1) the north-south streets serving Lots 1 through 27 shall be
terminated in cul-de-sacs at the north ends of the streets; 2) the cul-
de-sac at the west end of the street between Village VI and Village VII
shall be modified to a knuckle and lowered down the slope; and 3) the
emergency access to be provided at the north end of the site shall be
designed for emergency access only, not for through traffic.
59.
60.
The internal major collector loop streets shall be dedicated to the
City. These streets include those which connect the Villages and are
the main entrances to the project, and also include all streets in
Village VI.
Developer shall furnish and install signs stating "Private Street" and
"Fire Access - Park in Designated Locations Only" along all private
streets. Guest parking spaces shall be designated by sign paint or
equal.
61.
Access from the Reserve Training Center just south of Amador Valley
Boulevard shall be relocated to be directly opposite Amador Valley
Boulevard, and signal heads and phases shall be provided for this
movement (subject to Army approval).
VISUAL RESOURCES
62.
To the extent feasible, development shall provide for the incorporation
of part of the creek corridor into the park area, to provide views
uninterrupted by cyclone fencing (as determined appropriate and feasible
by the City and the Alameda County Flood Control District).
-15-
63.
64.
65.
66.
A landscaped buffer area 15 feet wide shall be incorporated into the
north side of the east-west street that divides Villages VI and VII.
This buffer shall extend from the entrance to the single-family Village
and continue west to the end of this street. The buffer shall be
designed to screen off the single-family area from offsite views through
the park, and to provide a transition between the single-family and
multi-family areas.
Detailed planting plans developed for the park area within the 500 foot
corridor east of Dougherty Road shall accommodate long-distance views to
the Dougherty Hills.
The following design criteria shall be reflected in the Site Development
Review submittals for Villages I through V for the Dougherty Road
frontage strip adjoining the proposed sound-architectural wall:
a)
Total minimum width of the strip, as measured from face-of-curb to
face-of-wall, shall be 19 feet, and shall be widened to 23 feet
wherever feasible. Where grade differentials between the project
area and the Dougherty Road frontage strip dictate, the sound-
architectural wail may be located approximately at grade with the
frontage strip (i.e., not located atop a berm). The width of the
frontage strip may be reduced to less than 19 feet where bus
turnouts will be required. ~'
b)
Four-foot minimum landscape strips on both sides of the sidewalk
shall be utilized (as measured from the face-of-curb to the front
edge of the sidewalk and between the rear edge of sidewalk and the
face of the sound-architectural wall).
c)
The sidewalk shall be a minimum of six feet in width and shall
meander both horizontally and vertically through the center ll-
foot strip (minimum width) that remains between the two minimum
landscape strips established above.
d)
Wall design shall provide detailed architectural design on both
sides of the wall and shall utilize "pop-outs" of a minimum depth
of three feet, being regularly spaced along the wall's entire
frontage.
The following design criteria shall be reflected in the Site Development
Review submittals for Villages I and II for the Amador Valley Boulevard
frontage strips adjoining the proposed perimeter fences or walls:
a)
Total minimum width of the strips, as measured from face-of-curb
to the fences or wall, shall be 16 feet, and shall be widened to
19 feet wherever feasible.
b)
Three-foot minimum landscape strips on both sides of the sidewalk
shall be utilized (as measured from the face-of-curb to the front
edge of the sidewalk and between the rear edge of sidewalk and the
face of the perimeter fence or wall).
c)
The pedestrian/bikeway path shall be a minimum width of eight feet
and shall meander both horizontally and vertically through the
fontage strips that remain between the two minimum landscape
strips established above. The pedestrian/bikeway path shall
extend from Dougherty Road to the west side of the entrance to
Villages I and II. From that point, the sidewalk shall be five
feet in width on the north side of Amador Valley Boulevard and
bicycle lanes shall be striped in the street. On the south side
of Amador Valley Boulevard, the sidewalk shall be constructed to
conform with the planned sidewalk for the undeveloped phase of the
Heritage Commons project.
d)
The fence or wall shall extend along the Village II frontage up to
the outside of the flood control channel.
-16-
67.
68.
69.
70.
71.
72.
73.
74.
75.
The sound-architectural wall along the Village II frontage shall extend
westerly along the Amador Valley Boulevard frontage for the minimum
distance necessary to provide the required sound attenuation for
proposed Building Group 26. The sound-architectural wall along the
perimeter of Village I shall extend from the Dougherty Road frontage
around the south and west side of the proposed convenience store parcel,
terminating at a point giving adequate separation from the Amador Valley
Boulevard right-of-way to provide visibility along the street and into
the parking area for the proposed convenience store site.
The undeveloped area on the west side of the site shall be offered for
dedication to the City or an appropriate public recreational district.
Areas across the site which are not accepted for dedication shall be
either included as part of a private lot or become part of the public
street right-of-way, be included as part of the creek channel, be
maintained as part of the proposed landscaping and lighting district, or
be placed in a private homeowners' association. How these areas are to
be distributed shall be subject to review and approval by the City
Engineer.
Single family homes in Village VI at higher elevations shall be subject
to architectural design guidelines requiring exterior colors and
materials compatible with the scenic corridor, established and
enforceable through project CC & Rs.
Engineered slopes shall be contoured to blend into the natural
topography and shall not, to the extent feasible, exceed 2.5:1 slopes.
Cleared open space areas shall be revegetated. Natural areas shall be
enhanced by planting of oak, naturalized grasses, or other native
vegetation.
In Village VI, uniform, durable fencing compatible in design and
materials with the natural appearance of the hills shall be installed
along the boundaries of all lots which are located on or adjacent to
graded slope areas.
Uniform tree plantings shall be installed and maintained on all graded
slope areas adjacent to single-family lots in Village VI. Approximately
one tree at 350 square feet of slope area shall be planted, or an
alternate standard approved through the respective Site Development
Review submittals. Tree species shall be compatible with native
vegetation.
Ail open space and landscaped areas now owned by individual single-
family lot owners or within Villages shall be placed within a lighting
and landscape special assessment district, or maintained by a master
homeowners association.
The Dougherty Road frontage width of the proposed commercial site
(proposed Lot #153) shall be increased to provide for an approximate
doubling of the on-site parking to be developed. This change shall be
generally consistent with the revised site plan received for the
commercial site and Village I, dated received February 25, 1986 (see
Background Attachment #16). To accommodate the increase in the size of
the commercial parcel, changes shall be made to the layout of building
groups in the adjoining sections of Village I.. The driveway to the
commercial site along Amador Valley Boulevard shall be moved westerly to
provide a wider separation between said driveway and the intersection of
Dougherty Road and Amador Valley Boulevard. Additional design
considerations involving the pedestrian walkway system, the gasoline
pump island layout, the method of tying into the adjoining sound-
architectural wall, etc., shall be addressed in conjunction with the
Site Development Review for this site. Part of the submittal
requirements for that subsequent submittal shall include information
documenting the anticipated parking requirements for the proposed
convenience store. The findings of the Study shall be utilized in the
-17-
determination of the required minimum size of the commercial site.
overhead utilities fronting the project on Dougherty Road shall be
undergrounded.
Ail
MISCELLANEOUS
76.
The project shall be constructed as approved. Minor modifications in
the design, but not the use, may be approved by Staff. Any other change
will require Planning Commission approval through the Conditonal Use
Permit review process or, depending on the magnitude of the
modification, submittal of a new Planned Development Rezoning submittal.
Changes to the proposed finished floor elevations and site grading for
single family residential lots proposed in Village VI shall generally
not exceed a maximum deviation of five feet from the pad elevations
indicated on the Revised Tentative Map and Development Plan, dated
received December 12, 1985.
77.
If occupancy within an individual Village is to occur in phases, all
physical improvements shall be required to be in place prior to
occupancy except for items specifically excluded in a Village'
Construction-Phased Occupancy Plan approved by the Planning Department.
No individual unit shall be occupied until the adjoining area is
finished, safe, accessible, provided with all reasonable expected
services and amenities, and completely separated from remaining
additional construction activity. Any approved VillageConstruction-
Phased Occupancy Plan shall have sufficient cash deposits or other
assurances to guarantee that the project and all associated improvements
shall be installed in a timely and satisfactory manner. At the request
of the Planning Director, written acknowledgements of continuing
construction activity shall be secured from the property owners and any
and all occupants or tenants for the portions of the Village to be
occupied, and shall be filed with the Planning Department. Said
acknowledgements for a subdivision shall be part of the settlement
documents between the developer and buyer.
78. Prior to final inspection and occupancy of any units:
Ae
Storm drainage facilities shall have been installed as approved by
the City Engineer.
Fire protection devices shall have been installed, be operable,
and conform to the specifications of and inspections by the Dublin
San Ramon Services District Fire Department.
C. Cable TV hook-up shall be provided to each unit:.
As-built drawings showing the locations of all underground
utilities (water, storm and sanitary sewer, gas, electric,
telephone and cabte TV) shall be provided to the City,
gJ
Street name signs, bearing such names as are approved by the
Planning DireCtor,. shall have been installed.i
79.
Prior to occupancy of any unit, each phase of development (landscaping,
irrigation, fencing and landscape lighting in accordance with approved
landscape and erosion control plans) shall have been installed, or a
bond or letter of credit for the landscaping, lighting, appurtenant
structures, and irrigation system shall be provided to the City. A
statement from the project Landscape Architect shall certify that the
landscaping has been installed in accordance with the plans and shall be
submitted to the Building Official and Planning Director.
80. Should the project be phased:
Ae
The undeveloped area shall be maintained as acceptable to the
DSRSD - Fire Department and shall be kept free of trash and
debris.
-18-
81o ·
82.
83.
84.
Be
A road system of a design determined acceptable to the City
Engineer and the Planning Department shall be installed.
Ce
Each phase shall be landscaped and developed such that should
construction of subsequent phases be delayed, the constructed
phase(s) will appear as a completed project.
Should the units be initially occupied as apartment units, the following
reports shall be filed with, and approved by, the City Engineer at the
time the units are put up for individual sale,
A report by a licensed roofing contractor certifying that the
roofs of all the structures are in good condition and notlikely
to be in need of replacement for at least 10 years. A reserve
deposit may be established to cover the estimated prorated costs
of roof replacement where replacement will be required prior to 10
years.
A report by a professional Engineer attesting, to the extent
reasonably feasible, that the structure of all buildings,
pavements, storm draininage facilities, and the interior and
exterior plumbing, electrical systems, and utility and mechanical
equipment to be owned in common, or as part of the individual
condominiums, are in good and serviceable condition.
Ce
A report by a licensed painting contractor that paint throughout
the project is in good condition and that the building exteriors
should not require repainting for at least five years. A reserve
deposit may be established to cover the estimated prorated costs
for the repainting of the units where repainting will be required
prior to a 5-year period.
A report by a licensed termite and pest control specialist
certifying that the structures are free of infestation and
structural damage caused by pests.
Should the units be initially occupied as apartment units, all
applicances shall either be replaced with new units or the initial
buyers provided with a one-year's parts and warranty guarantee on all
applicances.
The developer shall provide guarantees that a minimum of 10% of the
multi-family units in the project shall be maintained as rental units
for a period of five years. The document providing said agreement shall
be subject to review and approval by the City Attorney. Such 10% shall
be calculated, utilizing the number of units in Villages I, II, III, IV,
V and VII as a base (1019 proposed units for a commitment of 102 units
to the rental pool). Commencing with the date of issuance of an
occupancy permit on the 102nd multi-family unit within Villages I
through V, the developer shall guarantee that a minimum of 102 units
shall be available for rent at all times within the above Villages until
the Condition has been satisifed. This Condition may be met
individually within any one Village, or collectively over all the
affected Villages. Developer agrees that until the Condition has been
satisfied, there shall be no conversion of codominium units for sale
within Village V.
Minimal dimensional criteria for dwelling units established on the
single family residential lots in Village VI shall include the
following:
Front yards - 20-foot minimum; subject to review and approval by
the Planning Director, may be varied from 18 to 22
feet to provide variety while generally maintaining
the 20-foot average.
-19-
85.
86.
B. Side Yards -
1. One story units
- 5-foot minimum flat and useable each side
- 12-foot minimum street side Sideyard
2. Two story units
-5-foot minimum flat and useable each side
-15-foot minimum street side sideyard
C. Rear Yards - 20-foot minimum, to be generally flat and useable.
D. Pad Areas -
45' x 95' minimum, with the 45' width measured from
front setback line through to the rear of the lot.
In addition to the above, the design of single family residential units
developed shall provide for the maximum unit privacy through use of
building layouts which maximize useable side and rear yard areas with
offsets of windows and similar inter-building design Considerations.
The majority of the two-story units shall observe an additional front
yard setback requirement whereby the building face of the second story
shall observe a setback of an additional five feet ± from the building
face of the garage. Two'Story units shall generally avoid use of shed-
type roof designs, but rather shall generally utilize roof designs which
serve to mitigate possible visual impacts resulting from the height and
proximity of two-story units.
During the Site Development Review process, the developer may request
and be granted modifications from the above minimum rear yard
dimensional criteria in individual situations where such modifications
would add diversity to the project or privacy to individual units which,
in the discretion of the Planning Director, improves the overall design.
The builder shall maintain a minimum of 1,000 square feet of flat and
useable area within 80% of the rear yards and a minimum of 900 square
feet of flat and useable area within the remainder of the rear yards
through the selection of appropriate houses to fit individual lots.
Additionally, the developer shall investigate the feasibility of
steepening cut and fill slopes to increase the useable pad area without
impacting the stability of the slope design. The purpose of this
Condition is to encourage the proper matching of housing types to
individual lots and adjusting grades to increase useable area, but is
not intended to require a reduction in the number of lots during the
Site Development Review process.
Except as specifically modified by the above listed design criteria, or
as established elsewhere in the Conditions of Approval for this project,
the single family residential lots developed within Villages VI and VII
shall be subject to the guidelines of the R-1 Single Family Residential
District as regards both land use restrictions and minimum/maximum
development criteria.
To assure that adequate diversity of building architecture across the
project as a whole will be provided, individual Villages, or groupings
of contiguous Villages (i.e., Villages II and III as a grouping, and
Villages IV and V as a grouping) shall be designed in a manner to allow
them to stand alone with village-specific architectural features (such
as alternate types of roofing or siding materials, alternate use of open
or enclosed stairwells, etc.). Detailed design review of project
architecture shall be made at the time of submittal of the respective
Site Development Review applications for each proposed Village,
The minimum distances between buildings and building appurtenances in
the multi-family Villages shall comply with the following criteria:
The term "building wall" shall refer to the exterior side of building
walls containing heated space (with the exception of the enclosed entry
in the "E" type building).
20 feet between all building walls, with deviation from the
minimum separation subject to review and approval by the Planning
Director through the Site Development Review process, to consider
case-by-case reductions to 15 feet when:
-20-
The living room windows are separated by a minimum distance
of 40 feet measured perpendicularly from the sliding glass
door.
e
Living room to bedrooms are separated by 30 feet (measured
perpendicularly from the sliding glass door).
Be
Building/roadway separations, 15 feet minimum, except building
setbacks from Dougherty Road, Amador Valley Boulevard, and the
first 100 feet of each leg of the loop roads from the intersection
with Dougherty Road or Amador Valley Boulevard where a 20-foot
minimum setback (measured from the rear face of the sound
architectural wall or perimeter fence along Dougherty Road or
Amador Valley Boulevard ) shall be observed. The 20-foot minimum
setback along the loop roads shall be from the face of curb or
back of sidewalk, whichever is applicable.
C. Patio/deck and deck/building wall separations - 15-foot minimum.
Do
Building walls and parking area separations -10-foot minimum with
a minimum of five feet of the width landscaped f~or screening or
parking.
ge
Building appurtenances to building appurtenance separations
(including patios) - 10-foot minimum separation. Stairway
landings may be closer than 10 feet where privacy is not
compromised as approved by the Planning Director through the Site
Development Review process.
87.
The two easterly cross streets in Village VI shall be terminated in
cul-de-sacs. The applicant's engineer shall investigate the feasibility
of incorporating two additional cul-de-sacs, with emergency breakthrough
vehicular access inter-connection between the two cul-de-sacs, along the
most westerly proposed through street in Village VI (and subject to
Staff review of the Site DeveloPment Review for Village VI).
88.
The minimum width of the creek-side pedestrian walkway strip shall be 14
feet (measured from face-of-curb to the flood control maintenance fence)
for a minimum of 50% of the strip's frontage along Villages II through
V. Subject to review and approval by the Planning Director, this width
may be reduced to a minimum width of 10 feet for the remainder of the
referenced frontage. The pedestrian walkway strip shall include a 6-
foot minimumwidth concrete walkway which., wherever feasible, shall
meander within the creek-side walkway strip. The walkway shall also
maintain a four-foot landscaped setback from the curb and the flood
control fence where the width of the strip so allows.
PASSED, APPROVED AND ADOPTED this 24th day of March, 1986.
AYES:
Councilmembers Hegarty, Jeffery, Moffatt,
Vonheeder and Mayor Snyder
NOES: None
ABSENT: None
City Cler~ ~